首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Adaptive responses are induced by stress such as X radiation and result in a lower than expected biological response. Two-dose adaptive response experiments typically involve a low priming dose followed by a subsequent high radiation dose. Here, we used a sensitive in vivo chromosomal inversion assay to demonstrate for the first time an adaptive response when a low dose (0.01-1 mGy) was given several hours after a high 1000-mGy radiation dose. The adaptive responses in this study were of similar magnitude to the two-dose adaptive responses previously observed in this test system when the low dose was given first. A chromosomal inversion adaptive response was also induced by two 1000-mGy doses and when a 1-mGy dose was preceded or followed by a dose of 0.01 mGy, but not by two 4000-mGy doses. This is also the first example of an adaptive response when both doses are low. Our data agree with previous reports of an on-off mechanism of adaptive response. The induction of an adaptive response by a low dose after a high damaging dose provides evidence that the mechanisms underlying radiation adaptive responses are not due to prevention of damage induced by the high dose but to modulation of the cellular response to this damage.  相似文献   

2.
Since furazolidone is an antimicrobial drug, any possibility of its evoking an adaptive response appears to be very important. This response was studied in Vibrio cholerae cells as a model system. In order to determine this response, a dose-response relation of these cells to furazolidone and the kinetics of inactivation of the drug were studied. The study of the adaptive response of these cells to furazolidone reveals that cells treated with a low concentration of furazolidone for a particular period were 100% more resistant to the lethal effects of a subsequent challenging dose than control cultures. Variation of the challenging dose level showed better survival of adapted cells than control cells. A time-dependent response study reveals a maximum response at 15-30 min, and a gradual fall thereafter.  相似文献   

3.
The aim of the study was to investigate the effect of low doses of irradiation on the induction of an apoptotic adaptive response in the murine system using C3H/HeJ mice bearing 8 mm syngeneic tumors, HCa-I and OCa-I. In OCa-I, the 0.05 Gy priming dose significantly reduced the 25 Gy-induced apoptosis by 30%, whereas this reduction was not seen in HCa-I. The analysis of apoptosis-regulating molecules showed that the application of a priming dose increased the radiation- induced p53 level in both tumors. No other regulators changed in OCa-I. However, in HCa-I, the application of a priming dose increased radiation-induced Bcl-XL and Bcl-XS, but not Bcl-2 or Bax. An apoptotic adaptive response induced by low-dose radiation was shown in one murine tumor, OCa-I and Bcl-XL and Bcl-XS appeared to be implicated. Received: 4 April 2001 / Accepted: 20 September 2001  相似文献   

4.
Glyoxalase system, particularly glyoxalase I (Gly I) plays an important role in regulation of cell division and is considered to be a metabolic indicator of cell proliferation. The glyoxalase system is likely to have a close link with cellular radiosensitivity. Therefore, we have examined the effect of adaptive and split-dose of -rays on the activity of Gly I in the liver and spleen of mice. For the adaptive response studies, mice pre-treated with a conditioning dose of 0.5 Gy were given a challenging dose of 4 Gy at varying time intervals. In the split-dose studies, a dose of 4 Gy was delivered into two equal fractions and spaced at different time intervals. The results show that pre-exposure to a conditioning dose or the fractionation of total dose decreased the specific activity of Gly I in the liver and spleen of mice. The decreased activity of Gly I was suggestive of protective action induced by the conditioning dose and fractionation of dose. The similar pattern of radiation response of Gly I probably supported the possibility of involvement of a common pathway in the radiation-induced adaptive and split-dose effect. From these observations a close link between the Gly I and the adaptive-response as well as the split-dose effect is speculated. Since, the glyoxalase system is vital for a variety of biological functions including cell division and repair, the present findings may have relevance in understanding the dose-fractionation as well as the biological defence induced by low doses of radiations.  相似文献   

5.
The adaptive response is an important phenomenon in radiobiology. A study of the conditions essential for the induction of an adaptive response is of critical importance to understanding the novel biological defense mechanisms against the hazardous effects of radiation. In our previous studies, the specific dose and timing of radiation for induction of an adaptive response were studied in ICR mouse fetuses. We found that exposure of the fetuses on embryonic day 11 to a priming dose of 0.3 Gy significantly suppressed prenatal death and malformation induced by a challenging dose of radiation on embryonic day 12. Since a significant dose-rate effect has been observed in a variety of radiobiological phenomena, the effect of dose rate on the effectiveness of induction of an adaptive response by a priming dose of 0.3 Gy administered to fetuses on embryonic day 11 was investigated over the range from 0.06 to 5.0 Gy/min. The occurrence of apoptosis in limb buds, incidences of prenatal death and digital defects, and postnatal mortality induced by a challenging dose of 3.5 Gy given at 1.8 Gy/min to the fetuses on embryonic day 12 were the biological end points examined. Unexpectedly, effective induction of an adaptive response was observed within two dose-rate ranges for the same dose of priming radiation, from 0.18 to 0.98 Gy/ min and from 3.5 to 4.6 Gy/min, for reduction of the detrimental effect induced by a challenging dose of 3.5 Gy. In contrast, when the priming irradiation was delivered at a dose rate outside these two ranges, no protective effect was observed, and at some dose rates elevation of detrimental effects was observed. In general, neither a normal nor a reverse dose- rate effect was found in the dose-rate range tested. These results clearly indicated that the dose rate at which the priming irradiation was delivered played a crucial role in the induction of an adaptive response. This paper provides the first evidence for the existence of two dose-rate ranges for the same dose of priming radiation to successfully induce an adaptive response in mouse fetuses.  相似文献   

6.
A R Sinaiko 《Life sciences》1983,33(23):2269-2275
The role of the beta-adrenergic nervous and prostaglandin systems in vasodilator-induced activation of the renin-angiotensin system was studied in conscious rats. The plasma renin activity (PRA) response to intravenous hydralazine (0.25, 0.5 and 1 mg/kg body wt.) was compared to the PRA response following administration of similar doses of hydralazine to rats pretreated with either indomethacin (3 mg/kg body wt. i.v.) or indomethacin and propranolol (1 mg/kg body wt. i.v.). PRA increased significantly above control levels after each of the hydralazine doses. In rats pretreated with indomethacin, PRA did not increase with the 0.25 mg/kg dose of hydralazine; increased significantly with the 0.5 mg/kg dose but remained significantly lower than the PRA response in the absence of indomethacin; and increased with the 1 mg/kg dose to a level not significantly different from PRA in rats receiving only hydralazine. When rats were pretreated with indomethacin and propranolol, PRA did not increase significantly in response to either the 0.25 or 0.5 mg/kg doses of hydralazine. Although a statistically significant increase in PRA was noted with the 1 mg/kg dose of hydralazine, the level of PRA achieved was very low and only 15% of that observed with the other two treatment regimens (i.e., hydralazine alone or indomethacin and hydralazine). These results demonstrate that vasodilator-induced renin release is only partially mediated via the prostaglandin system, that the degree of this control is related to the intensity of vasodilator stimulus and that renin release following administration of hydralazine can be attributed almost entirely to activation of the beta-adrenergic nervous and prostaglandin systems.  相似文献   

7.
Wistar rats were given phentolamine into the ventriculus lateralis. The D1 group of rats received a larger dose than the D2 group. The animals were decapitated within 2 hours after phentolamine injection. The FALCK fluorescence technique was applied to demonstrate the fluorescence of catecholaminergic structures. The results in rat brain areas selected according to KONIG and KLIPPEL are shown in figs 10-46. Whereas earlier biochemical experiments did not show any phentolamine-induced changes in the NA level of the whole brain, the present histochemical experiments carried out with the fluorescence technique revealed the influence of phentolamine on individual structures and areas of the NA system. In comparison with the control material in 5 out of 11 areas the fluorescence was much weaker, in 3 it was similar to the control group, and in 3 (1 with a larger dose and 2 with a smaller dose of phentolamine) it was slightly stronger. The simultaneous increase of fluorescence in 6 out of 7 areas of the DA system may indicate a compensatory interaction of these areas as a response to the neuromediator decrease in the NA system. The paper discusses the increase in the intensity of fluorescence induced by a small dose of phentolamine in some brain areas, or by a large dose in others, both these alternatives depending on the neuromediator turnover.  相似文献   

8.
The present study describes the effect of a single dose of dexamethasone administered to mares at time of breeding. In an initial experiment, the authors investigated safety of treatment. In a second experiment the effect of treatment on the uterine environment, fetal development and pregnancy outcome was examined. In the final part of the study, mares susceptible to persistent mating induced endometritis were identified, by means of a risk factor score system and the effect of treatment evaluated. Results indicated that dexamethasone administered at breeding time did not negatively impact on mares medical and reproductive traits. A reduced inflammatory response was observed post-mating in treated versus control mares and mares with multiple risk factors for susceptibility to persistent mating induced endometritis showed improved pregnancy rates following treatment. The authors concluded that a single dose of dexamethasone administered at the time of breeding is safe and can be used to modulate the uterine inflammatory response to breeding in susceptible mares.  相似文献   

9.
ObjectiveDifferent dose response functions of EBT3 model GafChromic™ film dosimetry system have been compared in terms of sensitivity as well as uncertainty vs. error analysis. We also made an assessment of the necessity of scanning film pieces before and after irradiation.MethodsPieces of EBT3 film model were irradiated to different dose values in Solid Water (SW) phantom. Based on images scanned in both reflection and transmission mode before and after irradiation, twelve different response functions were calculated. For every response function, a reference radiochromic film dosimetry system was established by generating calibration curve and by performing the error vs. uncertainty analysis.ResultsResponse functions using pixel values from the green channel demonstrated the highest sensitivity in both transmission and reflection mode. All functions were successfully fitted with rational functional form, and provided an overall one-sigma uncertainty of better than 2% for doses above 2 Gy. Use of pre-scanned images to calculate response functions resulted in negligible improvement in dose measurement accuracy.ConclusionAlthough reflection scanning mode provides higher sensitivity and could lead to a more widespread use of radiochromic film dosimetry, it has fairly limited dose range and slightly increased uncertainty when compared to transmission scan based response functions. Double-scanning technique, either in transmission or reflection mode, shows negligible improvement in dose accuracy as well as a negligible increase in dose uncertainty. Normalized pixel value of the images scanned in transmission mode shows linear response in a dose range of up to 11 Gy.  相似文献   

10.
Complexities of lethal challenge animal models have prompted the investigation of immunogenicity assays as potency tests of anthrax vaccines. An ELISA was used to measure the antibody response to protective antigen (PA) in mice immunized once with a commercially available (AVA) or a recombinant PA vaccine (rPAV) formulated in-house with aluminum hydroxide. Results from the anti-PA ELISA were used to select a single dose appropriate for the development of a potency test. Immunization with 0.2 mL of AVA induced a measurable response in the majority of animals. This dose was located in the linear range of the vaccine dose–antibody response curve. In the case of rPAV, practical limitations prevented the finding of the best single dose for the potency testing of purified vaccines. In additional immunogenicity experiments neither the magnitude of the response to a single dose of vaccine, nor the estimation of the dose necessary to induce a measurable response were able to consistently detect brief exposure of vaccines to potentially damaging temperatures. However, differences detected for rPAV in the proportion of mice responding to the same dose of treated and untreated vaccine suggested that further assay development to increase the sensitivity of the latter design may be warranted.  相似文献   

11.
Antimutagenic effect of an antioxidant in mammals   总被引:2,自引:0,他引:2  
H W Renner 《Mutation research》1984,135(2):125-129
To test a possible antimutagenic activity of ethoxyquin (EQ) in bone-marrow cells, 3 cytogenetic tests with distinct genetic end-points were applied. Cyclophosphamide (CPA), serving as test mutagen, and the antioxidant EQ were administered immediately following each other to Chinese hamsters by stomach tube. Whereas the CPA dose was the same in each test, the EQ doses were increased up to a ratio of CPA/EQ = 1:25, in some cases up to 1:50. The formation of SCEs induced by CPA was not influenced by EQ--even at the highest dose. In the micronucleus test, however, EQ drastically reduced the micronucleus rate even at the lowest dose applied (20 mg/kg) and abolished the CPA effects at a dose of 100 mg/kg. This action of EQ against CPA was also found in the rat and mouse in the micronucleus test system. Two inbred strains of mouse showed similar reactions, but the induced micronucleus rate was higher and its decrease in response to increasing doses of EQ was more delayed. In the chromosome aberration test, EQ also showed a distinct anticlastogenic response. At higher EQ doses, all CPA-induced chromosomal damage was reduced down to the level of spontaneous rates. The anticlastogenic effect of EQ was quantitatively similar in the micronucleus and chromosome aberration tests. Only minor qualitative differences were recognizable.  相似文献   

12.
To further define requirements for T cell help in the stimulation of an in vivo IgE response, we studied a system in which the injection of mice with a goat antibody to mouse IgD (GaMD) stimulates large polyclonal IgG1 and IgE responses. In this system, both responses are blocked by anti-CD4 antibody, but only the IgE response is blocked by (anti-IL-4) antibody. Anti-CD4 antibody, if injected 5 days after GaMD, was found to inhibit the GaMD-induced IgE response to a much greater extent than the IgG1 response, even though both responses occur simultaneously and are inhibited to an equal extent by optimal or suboptimal doses of anti-CD4 antibody administered 2 days after GaMD. Even a suboptimal, 50-micrograms dose of anti-CD4 antibody, when injected 5 days after GaMD, inhibited the IgE response to a much greater extent than did an optimal 10-mg dose of anti-IL-4 antibody injected at the same time, even though 10 mg of anti-IL-4 antibody more completely inhibited GaMD-induced IgE production than did 50 micrograms of anti-CD4 antibody when injected 2 days after GaMD. These observations provide evidence that a late acting form of T cell help other than IL-4 is important for the generation of an IgE response but not an IgG1 response in GaMD-immunized mice.  相似文献   

13.
It is shown that a signoid dose vs. response curve will occur in any biological system in which the stimulant compound must diffuse significant distances to reach responding cells, even when the cells themselves respond according to Michaelis-Menten kinetics. Isolated pancreatic islets releasing insulin in response to glucose stimulation have been used as a specific example. Since diffusion and/or other physical processes can produce global effects which could account for the sigmoidal nature of a dose vs. response curve, the existence of complex molecular mechanisms of hormone-receptor interaction can not be inferred solely from the character of a dose vs. response relation.  相似文献   

14.
Lithium borosilicate glass composite (SiO2–Li2CO3–H3BO3) doped with various concentrations of Sm2O3 (0–0.7 mole %) was prepared using the melt quenching method. The investigated thermoluminescence (TL) characteristics of the prepared system revealed that the highest TL response was obtained for this glass composite at 0.05 mol% Sm2O3. In this study, the 0.05 mol% Sm2O3‐doped lithium borosilicate glass composite was subjected to detailed dosimetric investigation in terms of its annealing condition, dose–response, and minimum detectable dose. The reproducibility of the response, thermal characteristics, and optical fading were also studied. The obtained results showed that the prepared glass composite had a linear dose–response over the wide gamma dose range 2Gy to 2 kGy, as well as reasonable thermal fading and excellent reproducibility. These attributes render the composite under investigation promising for utilization in radiation detection.  相似文献   

15.
A system for scoring dicentric chromosomes by image analysis comprised fully automatic location of mitotic cells, automatic retrieval, focus and digitization at high resolution, automatic rejection of nuclei and debris and detection and segmentation of chromosome clusters, automatic centromere location, and subsequent rapid interactive visual review of potential dicentric chromosomes to confirm positives and reject false positives. A calibration set of about 15,000 cells was used to establish the quadratic dose response for 60Co gamma-irradiation. The dose-response function parameters were established by a maximum likelihood technique, and confidence limits in the dose response and in the corresponding inverse curve, of estimated dose for observed dicentric frequency, were established by Monte Carlo techniques. The system was validated in a blind trial by analysing a test set comprising a total of about 8000 cells irradiated to 1 of 10 dose levels, and estimating the doses from the observed dicentric frequency. There was a close correspondence between the estimated and true doses. The overall sensitivity of the system in terms of the proportion of the total population of dicentrics present in the cells analysed that were detected by the system was measured to be about 40%. This implies that about 2.5 times more cells must be analysed by machine than by visual analysis. Taking this factor into account, the measured review time and false positive rates imply that analysis by the system of sufficient cells to provide the equivalent of a visual analysis of 500 cells would require about 1 h for operator review.  相似文献   

16.
Cell density, nutritional state, and serum factors modify the growth response of LNCaP human prostatic cancer cells to dihydrotestosterone. Evaluation of growth response to dihydrotestosterone requires logarithmic transformation of cell count or thymidine incorporation data. Under conditions of dose response, growth increases with cell density but no significant interaction of dihydrotestosterone with cell density was found under optimal culture conditions. The frequency of media change was a significant factor in modulating dose response. When cells from cultures maintained at different feeding periods were plated at different cell densities of (trypan blue) viable cells, significant effects of plating density on dihydrotestosterone response were found. Dihydrotestosterone protects cells under the adverse effects of media deprivation. Under the extreme adverse effects of serum deprivation, cells respond to dihydrotestosterone even under conditions of increasing cell loss. The effects of dihydrotestosterone on final cell density were significant. In the absence of serum, the elongated cells of LNCaP assume a round shape, but many remain adherent to the culture dish and can be restored to normal morphology by serum. A number of growth factors fail to restore normal morphology that was completely restored by a combination of fibronectin and dihydrotestosterone. We have not developed a practicable serum-free system for LNCaP.  相似文献   

17.
The aim of this study is to dosimetrically characterize a new MRI based polymer gel system and to evaluate its usefulness in clinical practice just in terms of beam profile measurements.Normoxic N-vinylpyrrolidone based polymer gel (VIPET) phantoms were produced and used in order to perform three main sets of experiments: a) dose–response evaluation and reproducibility experiments, b) experiments for the evaluation of sensitivity of dose characteristics on ‘gel manufacture – irradiation’ time interval and c) experiments for the evaluation of sensitivity of dose characteristics on ‘irradiation – MRscanning’ time interval. It has been shown that this gel system can be used in a wide dose-range of 0–60 Gy. It exhibits a linear dose–response in the dose-range of 2–35 Gy. Following the proposed manufacturing method the dose–response characteristics are reproducible. Moreover, it seems that the optimum ‘gel manufacturing – irradiation’ time interval is 1 day. However, a ‘gel manufacturing – irradiation’ time interval up to ~1 week can be safely used. The optimum ‘irradiation – MRscanning’ time interval in terms of dose–response sensitivity and dose resolution can be reliably ranged from 1 day to 3 weeks. Finally, X-ray beam profile gel-measurements were performed and found to be in satisfying agreement with corresponding small sensitive volume ion chamber measurements. VIPET gel dosimeters preserved the spatial integrity of the dose distribution during a time period of 50 days post-irradiation. The studied gel system can be safely used in clinical practice within the practical limitations found and described in this work.  相似文献   

18.
Naltrexone-an opioid receptor antagonist, was administered intraperitoneally to sexually mature male and female common carp in the prespawning period, in order to investigate its effects on spontaneous or sGnRH-A-stimulated LH secretion. Naltrexone and sGnRH-A were injected at the same time. The possible involvement of a dopaminergic system in this process was studied in males pre-treated with pimozide (a dopamine receptor antagonist) 12 h before naltrexone and/or sGnRH-A administration. Blood samples for the analysis of carp LH concentrations were taken just before the injections and then after the injections, serial sampling during 24 h was performed. In male carp, naltrexone (500 or 5000 microg kg(-1)) decreased spontaneous LH release, but there were no effects of naltrexone on sGnRH-A-stimulated LH secretion. In males pre-treated with pimozide, a similar response to naltrexone injection (500 microg kg(-1)) as in pirnozide non-treated fish, was observed. The highest dose of naltrexone, 5000 microg kg(-1), significantly stimulated LH release, in response to sGnRH-A administration in pimozide pre-treated males. In female carp, contrary to males, naltrexone at a dose of 500 microg kg(-1), caused significant stimulation of spontaneous LH release. These data indicate that endogenous opioid peptides modify LH secretion in sexually mature carp. In males, they stimulate LH secretion, acting rather on the hypothalamic GnRH system and in females, opioids inhibit LH release by the influence on the dopaminergic system.  相似文献   

19.
It is shown that a sigmoid dose vs. response curve will occur in any biological system in which the stimulant compound must diffuse significant distances to reach responding cells, even when the cells themselves respond according to Michaelis-Menten kinetics. Isolated pancreatic islets releasing insulin in response to glucose stimulation have been used as a specific example. Since diffusion and/or other physical processes can produce global effects which could account for the sigmoidal nature of a dose vs. response curve, the existence of complex molecular mechanisms of hormone-receptor interaction can not be inferred solely from the character of a dose vs. response relation.  相似文献   

20.
Irradiation of whole blood and blood components before transfusion is currently the only accepted method to prevent Transfusion-Associated Graft-Versus-Host-Disease (TA-GVHD). However, choosing the appropriate technique to determine the dosimetric parameters associated with blood irradiation remains an issue. We propose a dosimetric system based on the standard Fricke Xylenol Gel (FXG) dosimeter and an appropriate phantom. The modified dosimeter was previously calibrated using a 60Co teletherapy unit and its validation was accomplished with a 137Cs blood irradiator. An ionization chamber, standard FXG, radiochromic film and thermoluminescent dosimeters (TLDs) were used as reference dosimeters to determine the dose response and dose rate of the 60Co unit. The dose distributions in a blood irradiator were determined with the modified FXG, the radiochromic film, and measurements by TLD dosimeters. A linear response for absorbed doses up to 54 Gy was obtained with our system. Additionally, the dose rate uncertainties carried out with gel dosimetry were lower than 5% and differences lower than 4% were noted when the absorbed dose responses were compared with ionization chamber, film and TLDs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号