首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report here an extension of homogeneous assays based on fluorescence intensity and lifetime measuring on DNA hybridization. A novel decay probe that allows simple one-step nucleic acid detection with subnanomolar sensitivity, and is suitable for closed-tube applications, is introduced. The decay probe uses fluorescence resonance energy transfer (FRET) between a europium chelate donor and an organic fluorophore acceptor. The substantial change in the acceptor emission decay time on hybridization with the target sequence allows the direct separation of the hybridized and unhybridized probe populations in a time-resolved measurement. No additional sample manipulation or self-hybridization of the probes is required. The wavelength and decay time of a decay probe can be adjusted according to the selection of probe length and acceptor fluorophore, thereby making the probes applicable to multiplexed assays. Here we demonstrate the decay probe principle and decay probe-based, one-step, dual DNA assay using celiac disease-related target oligonucleotides (single-nucleotide polymorphisms [SNPs]) as model analytes. Decay probes showed specific response for their complementary DNA target and allowed good signal deconvolution based on simultaneous optical and temporal filtering. This technique potentially could be used to further increase the number of simultaneously detected DNA targets in a simple one-step homogeneous assay.  相似文献   

2.
A fluorescent resonance energy transfer (FRET)-based hybridization assay for detecting multiplex ligation-dependent probe amplification (MLPA) products has been developed, extending the diagnostic power of the technique and demonstrating the possibility of combining MLPA with microarrays for the detection of multiple mutations. FRET is one of the most commonly used detection techniques for hybridization assays. To investigate the applicability of FRET based detection of MLPA products, a sandwich assay was designed to detect gene copy number by exploiting an immobilized probe labeled with an acceptor dye, Alexa Fluor 555, which hybridises to specific PCR amplicons, followed by hybridization of a second probe labeled with the donor dye, Alexa Fluor 488. Following excitation of the Alexa Fluor 488, a FRET signal was produced only if a DNA sequence specific to the BRCA1 exon 13 was present in the test sample. We have verified this assay on a DNA sample of a patient carrying a heterozygous BRCA1 exon 13 deletion using male genomic DNA as control. Here we demonstrate that the DNA sample containing the heterozygous deletion generated a considerably reduced FRET signal as compared to the control male human DNA. Our results show that the FRET design presented in this study can differentiate between reduced copy numbers any genomic DNA sequence after MLPA analysis, and the reported format is applicable to multiplex detection of MLPA products, using microarrays, or optical biosensor arrays, and future work will focus on the demonstration of this.  相似文献   

3.
4.
5.
A new displacement hybridisation method is reported using a single strand DNA probe, labelled with an acceptor fluorophore (oregon green 488). Detection of double stranded sample target is shown, with discrimination between the probe, duplexed during the assay, and free single stranded probe DNA achieved through the FRET from a donor grove fluorophore (Hoechst 33258). A model for the kinetics of the displacement assay is presented and the course of the assay predicted according to probe/target ratios and sequence. The modelled predictions are consistent with the experimental data showing single base pair mismatch discrimination. The pattern of response according to the mismatch/perfect complement ratio in a mixed sample is also considered with an allele-discrimination ratio lying between the homozygous gene and total mismatch case, according to ratio. The assay is shown to be tolerant of different probe concentrations and ratios and through the dual wavelength recorded signals from donor and FRET acceptor, internal baseline correction is achieved with excellent noise reduction through ratiometric measurement.  相似文献   

6.
A new method for DNA diagnostics based on template-directed primer extension and detection by fluorescence resonance energy transfer is described. In this method, amplified genomic DNA fragments containing polymorphic sites are incubated with a 5'-fluorescein-labeled primer (designed to hybridize to the DNA template adjacent to the polymorphic site) in the presence of allelic dye-labeled dideoxyribonucleoside triphosphates and a modified Taq DNA polymerase (Klentaq1-FY). The dye-labeled primer is extended one base by the dye-terminator specific for the allele present on the template. At the end of the genotyping reaction, the fluorescence intensities of the two dyes in the reaction mixture are analyzed directly without separation or purification. This homogeneous DNA diagnostic method, which we call the template-directed dye-terminator incorporation assay, is shown to be highly sensitive and specific and is suitable for automated genotyping of large numbers of samples.  相似文献   

7.
Fluorescence resonance energy transfer (FRET) in association with a time-resolved fluorescence mode of detection was used to design a new homogeneous technology suitable to monitor biomolecular interactions. A lanthanide cryptate characterised by a long lived fluorescence emission was used as donor and a cross-linked allophycocyanine was used as acceptor. This new donor/acceptor pair displayed an exceptionally large Forster radius of 9 nm. This allowed to build up a set of labelling strategies to probe the interactions between biomolecules with an emphasis on fully indirect cassette formats particularly suitable for high throughput screening applications. Herein we describe the basics of the technology, review the latest applications to the study of molecular interactions involved in cells and new oligonucleotides based assays.  相似文献   

8.
DNA polymerases discriminate between correct and incorrect nucleotide substrates during a "nonchemical" step that precedes phosphodiester bond formation in the enzymatic cycle of nucleotide incorporation. Despite the importance of this process in polymerase fidelity, the precise nature of the molecular events involved remains unknown. Here we report a fluorescence resonance energy transfer (FRET) system that monitors conformational changes of a polymerase-DNA complex during selection and binding of nucleotide substrates. This system utilizes the fluorescent base analogue 1,3-diaza-2-oxophenothiazine (tC) as the FRET donor and Alexa-555 (A555) as the acceptor. The tC donor was incorporated within a model DNA primer/template in place of a normal base, adjacent to the primer 3' terminus, while the A555 acceptor was attached to an engineered cysteine residue (C751) located in the fingers subdomain of the Klenow fragment (KF) polymerase. The FRET efficiency increased significantly following binding of a correct nucleotide substrate to the KF-DNA complex, showing that the fingers had closed over the active site. Fluorescence anisotropy titrations utilizing tC as a reporter indicated that the DNA was more tightly bound by the polymerase under these conditions, consistent with the formation of a closed ternary complex. The rate of the nucleotide-induced conformational transition, measured in stopped-flow FRET experiments, closely matched the rate of correct nucleotide incorporation, measured in rapid quench-flow experiments, indicating that the conformational change was the rate-limiting step in the overall cycle of nucleotide incorporation for the labeled KF-DNA system. Taken together, these results indicate that the FRET system can be used to probe enzyme conformational changes that are linked to the biochemical function of DNA polymerase.  相似文献   

9.
A new method for specific detection of proteins based on fluorescence resonance energy transfer (FRET) using affinity proteins (affibodies) derived from combinatorial engineering of Staphylococcal protein A has been developed. Antiidiotypic affibody pairs were used in a homogeneous competitive binding assay, where the idiotypic, target-specific affibody was labeled with fluorescein and the antiidiotypic affibody was labeled with tetramethylrhodamine. Intermolecular FRET between the two fluorescent probes was observed in the antiidiotypic affibody complex, but upon addition of target protein the antiidiotypic affibody was displaced, which was monitored by a shift in the relative emission of the donor and acceptor fluorophores. The feasibility of the system was demonstrated by the detection of IgA and Taq DNA polymerase with high specificity, using two different antiidiotypic affibody pairs. Detection of Taq DNA polymerase in 25% human plasma was successfully carried out, demonstrating that the method can be used for analysis of proteins in samples of complex composition.  相似文献   

10.
A homogeneous high-throughput screening method based on time-resolved fluorescence resonance energy transfer (TR-FRET) for the measurement of calcium-dependent multimerization of an EF-hand protein, sorcin, is described. The assay is based on a specific sorcin binding peptide conjugated either with an intrinsically highly fluorescent europium chelate (donor) or an Alexa Fluor 700 fluorophore (acceptor). Addition of calcium results in multimerization of sorcin, allowing several peptides to bind simultaneously to the epitopes of the multimeric protein complex, and the proximity of peptides labeled either with donor or acceptor label results in fluorescence resonance energy transfer between the 2 labels. When no calcium is present, the protein remains in a monomer form, and thus no FRET can take place. In the optimized assay construct, the assay was performed in 45 min, and a more than 20-fold signal-to-background ratio was achieved. The reversibility of sorcin multimerization was shown by chelating free calcium with ethylenediamine tetraacetic acid (EDTA). The developed homogeneous assay can be used in screening molecules that either inhibit or enhance multimerization of sorcin, and the assay format is applicable to various noncompetitive high-throughput screening assays detecting protein multimerization reactions.  相似文献   

11.
In Förster resonance energy transfer (FRET) experiments, extracting accurate structural information about macromolecules depends on knowing the positions and orientations of donor and acceptor fluorophores. Several approaches have been employed to reduce uncertainties in quantitative FRET distance measurements. Fluorophore-position distributions can be estimated by surface accessibility (SA) calculations, which compute the region of space explored by the fluorophore within a static macromolecular structure. However, SA models generally do not take fluorophore shape, dye transition-moment orientation, or dye-specific chemical interactions into account. We present a detailed molecular-dynamics (MD) treatment of fluorophore dynamics for an ATTO donor/acceptor dye pair and specifically consider as case studies dye-labeled protein-DNA intermediates in Cre site-specific recombination. We carried out MD simulations in both an aqueous solution and glycerol/water mixtures to assess the effects of experimental solvent systems on dye dynamics. Our results unequivocally show that MD simulations capture solvent effects and dye-dye interactions that can dramatically affect energy transfer efficiency. We also show that results from SA models and MD simulations strongly diverge in cases where donor and acceptor fluorophores are in close proximity. Although atomistic simulations are computationally more expensive than SA models, explicit MD studies are likely to give more realistic results in both homogeneous and mixed solvents. Our study underscores the model-dependent nature of FRET analyses, but also provides a starting point to develop more realistic in silico approaches for obtaining experimental ensemble and single-molecule FRET data.  相似文献   

12.
In Förster resonance energy transfer (FRET) experiments, extracting accurate structural information about macromolecules depends on knowing the positions and orientations of donor and acceptor fluorophores. Several approaches have been employed to reduce uncertainties in quantitative FRET distance measurements. Fluorophore-position distributions can be estimated by surface accessibility (SA) calculations, which compute the region of space explored by the fluorophore within a static macromolecular structure. However, SA models generally do not take fluorophore shape, dye transition-moment orientation, or dye-specific chemical interactions into account. We present a detailed molecular-dynamics (MD) treatment of fluorophore dynamics for an ATTO donor/acceptor dye pair and specifically consider as case studies dye-labeled protein-DNA intermediates in Cre site-specific recombination. We carried out MD simulations in both an aqueous solution and glycerol/water mixtures to assess the effects of experimental solvent systems on dye dynamics. Our results unequivocally show that MD simulations capture solvent effects and dye-dye interactions that can dramatically affect energy transfer efficiency. We also show that results from SA models and MD simulations strongly diverge in cases where donor and acceptor fluorophores are in close proximity. Although atomistic simulations are computationally more expensive than SA models, explicit MD studies are likely to give more realistic results in both homogeneous and mixed solvents. Our study underscores the model-dependent nature of FRET analyses, but also provides a starting point to develop more realistic in silico approaches for obtaining experimental ensemble and single-molecule FRET data.  相似文献   

13.
@Chromatin nanoscale architecture in live cells can be studied by Förster resonance energy transfer (FRET) between fluorescently labeled chromatin components, such as histones. A higher degree of nanoscale compaction is detected as a higher FRET level, since this corresponds to a higher degree of proximity between donor and acceptor molecules. However, in such a system, the stoichiometry of the donors and acceptors engaged in the FRET process is not well defined and, in principle, FRET variations could be caused by variations in the acceptor‐to‐donor ratio rather than distance. Here, to get a FRET level independent of the acceptor‐to‐donor ratio, we combine fluorescence lifetime imaging detection of FRET with a normalization of the FRET level to a pixel‐wise estimation of the acceptor‐to‐donor ratio. We use this method to study FRET between two DNA binding dyes staining the nuclei of live cells. We show that this acceptor‐to‐donor ratio corrected FRET imaging reveals variations of nanoscale compaction in different chromatin environments. As an application, we monitor the rearrangement of chromatin in response to laser‐induced microirradiation and reveal that DNA is rapidly decompacted, at the nanoscale, in response to DNA damage induction.   相似文献   

14.
Double-stranded oligonucleotides containing the sequence 5'-GGCC-3' can be intrinsically bent, according to X-ray crystallography and gel electrophoresis mobility studies. We have performed fluorescence resonance energy transfer (FRET) experiments with dye-labeled oligonucleotides to further investigate the solution structure of this sequence. We find that 5'-GGCC-3'-containing oligonucleotides bring 5'-attached donor and acceptor dyes much closer together than a comparable "straight" sequence that contains 5'-GCGC-3'. The bend angle for the 5'-GGCC-3' sequence is estimated to be approximately 70 degrees, much larger than the crystallographically observed 23 degrees kink but in agreement with other FRET work. In contrast to gel electrophoresis studies, divalent metal ions do not promote increased kinking in 5'-GGCC-3' above background as judged by FRET. Thus, sequence-dependent structural effects in DNA may be a complicating feature of FRET experiments.  相似文献   

15.
Molecular beacons for detecting DNA binding proteins   总被引:9,自引:0,他引:9  
We report here a simple, rapid, homogeneous fluorescence assay, the molecular beacon assay, for the detection and quantification of sequence-specific DNA-binding proteins. The central feature of the assay is the protein-dependent association of two DNA fragments each containing about half of a DNA sequence defining a protein-binding site. Protein-dependent association of DNA fragments can be detected by any proximity-based spectroscopic signal, such as fluorescence resonance energy transfer (FRET) between fluorochromes introduced into these DNA molecules. The assay is fully homogeneous and requires no manipulations aside from mixing of the sample and the test solution. It offers flexibility with respect to the mode of signal detection and the fluorescence probe, and is compatible with multicolor simultaneous detection of several proteins. The assay can be used in research and medical diagnosis and for high-throughput screening of drugs targeted to DNA-binding proteins.  相似文献   

16.
Enzymatic ligation methods are useful in diagnostic detection of DNA sequences. Here we describe the investigation of nonenzymatic phosphorothioate-iodide DNA autoligation chemistry as a method for detection and identification of both RNA and DNA sequences. Combining ligation specificity with the hybridization specificity of the ligated product is shown to yield discrimination of a point mutation as high as >10(4)-fold. Unlike enzymatic ligations, this reaction is found to be equally efficient on RNA or DNA templates. The reaction is also shown to exhibit a significant level of self-amplification, with the template acting in catalytic fashion to ligate multiple pairs of probes. A strategy for fluorescence labeling of three autoligating energy transfer (ALET) probes and directly competing them for autoligation on a target sequence is described. The method is tested in several formats, including solution phase, gel, and blot assays. The ALET probe design offers direct RNA detection, combining high sequence specificity with an easily detectable color change by fluorescence resonance energy transfer (FRET).  相似文献   

17.
Fluorescence resonance energy transfer (FRET) is a technique used for quantifying the distance between two molecules conjugated to different fluorophores. By combining optical microscopy with FRET it is possible to obtain quantitative temporal and spatial information about the binding and interaction of proteins, lipids, enzymes, DNA, and RNA in vivo. In conjunction with the recent development of a variety of mutant green fluorescent proteins (mtGFPs), FRET microscopy provides the potential to measure the interaction of intracellular molecular species in intact living cells where the donor and acceptor fluorophores are actually part of the molecules themselves. However, steady-state FRET microscopy measurements can suffer from several sources of distortion, which need to be corrected. These include direct excitation of the acceptor at the donor excitation wavelengths and the dependence of FRET on the concentration of acceptor. We present a simple method for the analysis of FRET data obtained with standard filter sets in a fluorescence microscope. This method is corrected for cross talk (any detection of donor fluorescence with the acceptor emission filter and any detection of acceptor fluorescence with the donor emission filter), and for the dependence of FRET on the concentrations of the donor and acceptor. Measurements of the interaction of the proteins Bcl-2 and Beclin (a recently identified Bcl-2 interacting protein located on chromosome 17q21), are shown to document the accuracy of this approach for correction of donor and acceptor concentrations, and cross talk between the different filter units.  相似文献   

18.
19.
FRET is a process whereby energy is non-radiatively transferred from an excited donor molecule to a ground-state acceptor molecule through long-range dipole-dipole interactions1. In the present sensing assay, we utilize an interesting property of PDA: blue-shift in the UV-Vis electronic absorption spectrum of PDA (Figure 1) after an analyte interacts with receptors attached to PDA2,3,4,7. This shift in the PDA absorption spectrum provides changes in the spectral overlap (J) between PDA (acceptor) and rhodamine (donor) that leads to changes in the FRET efficiency. Thus, the interactions between analyte (ligand) and receptors are detected through FRET between donor fluorophores and PDA. In particular, we show the sensing of a model protein molecule streptavidin. We also demonstrate the covalent-binding of bovine serum albumin (BSA) to the liposome surface with FRET mechanism. These interactions between the bilayer liposomes and protein molecules can be sensed in real-time. The proposed method is a general method for sensing small chemical and large biochemical molecules. Since fluorescence is intrinsically more sensitive than colorimetry, the detection limit of the assay can be in sub-nanomolar range or lower8. Further, PDA can act as a universal acceptor in FRET, which means that multiple sensors can be developed with PDA (acceptor) functionalized with donors and different receptors attached on the surface of PDA liposomes.  相似文献   

20.
The ubiquitous calcium regulating protein calmodulin (CaM) has been utilized as a model drug target in the design of a competitive binding fluorescence resonance energy transfer assay for pharmacological screening. The protein was labeled by covalently attaching the thiol-reactive fluorophore, N-[2-(1-maleimidyl)ethyl]-7-(diethylamino)coumarin-3-carboxamide (MDCC) to an engineered C-terminal cysteine residue. Binding of the environmentally sensitive hydrophobic probe 2,6-anilinonaphthalene sulfonate (2,6-ANS) to CaM could be monitored by an increase in the fluorescence emission intensity of the 2,6-ANS. Evidence of fluorescence resonance energy transfer (FRET) from 2,6-ANS (acting as a donor) to MDCC (the acceptor in this system) was also observed; fluorescence emission representative of MDCC could be seen after samples were excited at a wavelength specific for 2,6-ANS. The FRET signal was monitored as a function of the concentration of calmodulin antagonists in solution. Calibration curves for both a selection of small molecules and a series of peptides based upon known CaM-binding domains were obtained using this system. The assay demonstrated dose-dependent antagonism by analytes known to hinder the biological activity of CaM. These data indicate that the presence of molecules known to bind CaM interfere with the ability of FRET to occur, thus leading to a concentration-dependent decrease of the ratio of acceptor:donor fluorescence emission. This assay can serve as a general model for the development of other protein binding assays intended to screen for molecules with preferred binding activity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号