首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
Mass spectrometers equipped with matrix‐assisted laser desorption/ionization (MALDI‐MS) require frequent multipoint calibration to obtain good mass accuracy over a wide mass range and across large numbers of samples. In this study, we introduce a new synthetic peptide mass calibration standard termed PAS‐cal tailored for MALDI‐MS based bottom‐up proteomics. This standard consists of 30 peptides between 8 and 37 amino acids long and each constructed to contain repetitive sequences of Pro, Ala and Ser as well as one C‐terminal arginine residue. MALDI spectra thus cover a mass range between 750 and 3200 m/z in MS mode and between 100 and 3200 m/z in MS/MS mode. Our results show that multipoint calibration of MS spectra using PAS‐cal peptides compares well to current commercial reagents for protein identification by PMF. Calibration of tandem mass spectra from LC‐MALDI experiments using the longest peptide, PAS‐cal37, resulted in smaller fragment ion mass errors, more matching fragment ions and more protein and peptide identifications compared to commercial standards, making the PAS‐cal standard generically useful for bottom‐up proteomics.  相似文献   

2.
MALDI MS profiling, using easily available body fluids such as blood serum, has attracted considerable interest for its potential in clinical applications. Despite the numerous reports on MALDI MS profiling of human serum, there is only scarce information on the identity of the species making up these profiles, particularly in the mass range of larger peptides. Here, we provide a list of more than 90 entries of MALDI MS profile peak identities up to 10 kDa obtained from human blood serum. Various modifications such as phosphorylation were detected among the peptide identifications. The overlap with the few other MALDI MS peak lists published so far was found to be limited and hence our list significantly extends the number of identified peaks commonly found in MALDI MS profiling of human blood serum.  相似文献   

3.
A novel strategy based on carboxy group derivatization is presented for specific characterization of phosphopeptides. By tagging the carboxy group with 1‐(2‐pyrimidyl) piperazine (PP), the ion charge states of phosphopeptides can be largely enhanced, showing great advantages for sequencing phosphorylated peptides with electron‐transfer dissociation MS. Besides, after PP‐derivatization, most non‐specific bindings can be avoided by eliminating the interaction between the carboxy group and TiO2, greatly improving the specificity of TiO2‐based phosphopeptide enrichment strategy. Moreover, being tagged with a hydrophobic group, the retention time of phosphopeptides in RPLC can be prolonged, overcoming the difficulty of separating phosphopeptides in RPLC‐based approach. Together with several other advantages, such as ease of handling, rapid reaction time, broad applicability and good reproducibility, this PP‐derivatization method is promising for high‐throughput phosphoproteome research.  相似文献   

4.
Mark L. Stolowitz 《Proteomics》2012,12(23-24):3438-3450
Over the course of the last decade, a number of investigators have come to appreciate that the surface of a MALDI target, after suitable modification, can be used for selective enrichment of peptides and proteins. More recently, surface‐modified nanoparticles (NPs) that readily co‐crystallize in MALDI matrix, are not ionized by laser desorption/ionization, and do not interfere with MS have attracted interest as alternatives to surface‐modified targets for selective enrichment of peptides and proteins. Surface‐modified targets and NPs facilitate parallel processing of samples, and when used in conjunction with MALDI mass spectrometers with kHz lasers enable development of high‐throughput proteomics platforms. Targets and NPs for reversed phase and ion exchange retention, selective enrichment of glycopeptides, selective enrichment of phosphopeptides, and immunoaffinity MS are described in conjunction with details regarding their preparation and utility. Commercial availability of the reagents and substrates required to prepare surface‐modified targets and NPs is also discussed.  相似文献   

5.
Proteomics profiling of intact proteins based on MALDI‐TOF MS and derived platforms has been used in cancer biomarker discovery studies. This approach suffers from a number of limitations such as low resolution, low sensitivity, and that no knowledge is available on the identity of the respective proteins in the discovery mode. Nevertheless, it remains the most high‐throughput, untargeted mode of clinical proteomics studies to date. Here we compare key protein separation and MS techniques available for protein biomarker identification in this type of studies and define reasons of uncertainty in protein peak identity. As a result of critical data analysis, we consider 3D protein separation and identification workflows as optimal procedures. Subsequently, we present a new protocol based on 3D LC‐MS/MS with top‐down at high resolution that enabled the identification of HNRNP A2/B1 intact peptide as correlating with the estrogen receptor expression in breast cancer tissues. Additional development of this general concept toward next generation, top‐down based protein profiling at high resolution is discussed.  相似文献   

6.
MS‐based proteomics has become the most utilized tool to characterize histone PTMs. Since histones are highly enriched in lysine and arginine residues, lysine derivatization has been developed to prevent the generation of short peptides (<6 residues) during trypsin digestion. One of the most adopted protocols applies propionic anhydride for derivatization. However, the propionyl group is not sufficiently hydrophobic to fully retain the shortest histone peptides in RP LC, and such procedure also hampers the discovery of natural propionylation events. In this work we tested 12 commercially available anhydrides, selected based on their safety and hydrophobicity. Performance was evaluated in terms of yield of the reaction, MS/MS fragmentation efficiency, and drift in retention time using the following samples: (i) a synthetic unmodified histone H3 tail, (ii) synthetic modified histone peptides, and (iii) a histone extract from cell lysate. Results highlighted that seven of the selected anhydrides increased peptide retention time as compared to propionic, and several anhydrides such as benzoic and valeric led to high MS/MS spectra quality. However, propionic anhydride derivatization still resulted, in our opinion, as the best protocol to achieve high MS sensitivity and even ionization efficiency among the analyzed peptides.  相似文献   

7.
Flea identification is a significant issue because some species are considered as important vectors of several human pathogens that have emerged or re‐emerged recently, such as Bartonella henselae (Rhizobiales: Bartonellaceae) and Rickettsia felis (Rickettsiales: Rickettsiaceae). Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) has been evaluated in recent years for the identification of multicellular organisms, including arthropods. A preliminary study corroborated the usefulness of this technique for the rapid identification of fleas, creating a preliminary database containing the spectra of five species of flea. However, longterm flea preservation in ethanol did not appear to be an adequate method of storage in the context of specimen identification by MALDI‐TOF MS profiling. The goal of the present work was to assess the performance of MALDI‐TOF MS in the identification of seven flea species [Ctenocephalides felis (Siphonaptera: Pulicidae), Ctenocephalides canis, Pulex irritans (Siphonaptera: Pulicidae), Archaeopsylla erinacei (Siphonaptera: Pulicidae), Leptopsylla taschenbergi (Siphonaptera: Ceratophyllidae), Stenoponia tripectinata (Siphonaptera: Stenoponiidae) and Nosopsyllus fasciatus (Siphonaptera: Ceratophyllidae)] collected in the field and stored in ethanol for different periods of time. The results confirmed that MALDI‐TOF MS can be used for the identification of wild fleas stored in ethanol. Furthermore, this technique was able to discriminate not only different flea genera, but also the two congeneric species C. felis and C. canis.  相似文献   

8.
The discovery of novel biomarkers by means of advanced detection tools based on proteomic analysis technologies necessitates the development of improved diagnostic methods for application in clinical routine. On the basis of three different application examples, this review presents the limitations of conventional routine diagnostic assays and illustrates the advantages of immunoaffinity enrichment combined with MALDI‐TOF MS. Applying this approach increases the specificity of the analysis supporting a better diagnostic recognition, sensitivity, and differentiation of certain diseases. The use of MALDI‐TOF MS as detection method facilitates the identification of modified peptides and proteins providing additional information. Further, employing respective internal standard peptides allows for relative and absolute quantitation which is mandatory in the clinical context. Although MALDI‐TOF MS is not yet established for clinical routine diagnostics this technology has a high potential for improvement of clinical diagnostics and monitoring therapeutic efficacy.  相似文献   

9.
We describe a mass spectrometric method for distinguishing between free and modified forms of the C‐terminal carboxyl group of peptides and proteins, in combination with chemical approaches for the isolation of C‐terminal peptides and site‐specific derivatization of the C‐terminal carboxyl group. This method could most advantageously be exploited to discriminate between peptides having C‐terminal carboxyl groups in the free (COOH) and amide (CONH2) forms by increasing their mass difference from 1 to 14 Da by selectively converting the free carboxyl group into methylamide (CONHCH3). This method has been proven to be applicable to peptides containing aspartic and glutamic acids, because all the carboxyl groups except the C‐terminal one are inert to derivatization, according to oxazolone chemistry. The efficiency of the method is illustrated by a comparison of the peaks of processed peptides obtained from a mixture of adrenomedullin, calcitonin, and BSA. Among these components of the mixture, only the C‐terminal peptide of BSA exhibited the mass shift of 13 Da upon treatment, eventually unambiguously validating the C‐terminal amide structures of adrenomedullin and calcitonin. The possibility of extending this method for the analysis of C‐terminal PTMs is also discussed.  相似文献   

10.
In this work, for the first time, a novel C60‐functionalized magnetic silica microsphere (designated C60‐f‐MS) was synthesized by radical polymerization of C60 molecules on the surface of magnetic silica microspheres. The resulting C60‐f‐MS microsphere has magnetite core and thin C60 modified silica shell, which endow them with useful magnetic responsivity and surface affinity toward low‐concentration peptides and proteins. As a result of their excellent magnetic property, the synthesized C60‐f‐MS microspheres can be easily separated from sample solution without ultracentrifuge. The C60‐f‐MS microspheres were successfully applied to the enrichment of low‐concentration peptides in tryptic protein digest and human urine via a MALDI‐TOF MS analysis. Moreover, they were demonstrated to have enrichment efficiency for low‐concentration proteins. Due to the novel materials maintaining excellent magnetic properties and admirable adsorption, the process of enrichment and desalting is very fast (only 5 min), convenient and efficient. As it has been demonstrated in the study, newly developed fullerene‐derivatized magnetic silica materials are superior to those already available in the market. The facile and low‐cost synthesis as well as the convenient and efficient enrichment process of the novel C60‐f‐MS microspheres makes it a promising candidate for isolation of low‐concentration peptides and proteins even in complex biological samples such as serum, plasma, and urine or cell lysate.  相似文献   

11.
Label‐free quantitative MS based on the Normalized Spectral Abundance Factor (NSAF) has emerged as a straightforward and robust method to determine the relative abundance of individual proteins within complex mixtures. Here, we present Morpheus Spectral Counter (MSpC) as the first computational tool that directly calculates NSAF values from output obtained from Morpheus, a fast, open‐source, peptide‐MS/MS matching engine compatible with high‐resolution accurate‐mass instruments. NSAF has distinct advantages over other MS‐based quantification methods, including a greater dynamic range as compared to isobaric tags, no requirement to align and re‐extract MS1 peaks, and increased speed. MSpC features an easy‐to‐use graphic user interface that additionally calculates both distributed and unique NSAF values to permit analyses of both protein families and isoforms/proteoforms. MSpC determinations of protein concentration were linear over several orders of magnitude based on the analysis of several high‐mass accuracy datasets either obtained from PRIDE or generated with total cell extracts spiked with purified Arabidopsis 20S proteasomes. The MSpC software was developed in C# and is open sourced under a permissive license with the code made available at http://dcgemperline.github.io/Morpheus_SpC/ .  相似文献   

12.
Arthropod‐borne diseases are important causes of morbidity and mortality. The identification of vector species relies mainly on morphological features and/or molecular biology tools. The first method requires specific technical skills and may result in misidentifications, and the second method is time‐consuming and expensive. The aim of the present study is to assess the usefulness and accuracy of matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) as a supplementary tool with which to identify mosquito vector species and to invest in the creation of an international database. A total of 89 specimens belonging to 10 mosquito species were selected for the extraction of proteins from legs and for the establishment of a reference database. A blind test with 123 mosquitoes was performed to validate the MS method. Results showed that: (a) the spectra obtained in the study with a given species differed from the spectra of the same species collected in another country, which highlights the need for an international database; (b) MALDI‐TOF MS is an accurate method for the rapid identification of mosquito species that are referenced in a database; (c) MALDI‐TOF MS allows the separation of groups or complex species, and (d) laboratory specimens undergo a loss of proteins compared with those isolated in the field. In conclusion, MALDI‐TOF MS is a useful supplementary tool for mosquito identification and can help inform vector control.  相似文献   

13.
14.
During gas chromatography (GC) analysis of fatty acid (FA) composition of the dinoflagellate Gymnodinium kowalevskii, we found unex‐pectedly low and irreproducible content of all‐cis‐3,6,9,12,15‐octadecapentaenoic acid (18:5n‐3), which is an important chemotaxonomic marker of several classes of microalgae. We compared chromatographic behavior of 18:5n‐3 methyl ester and other GC derivatives obtained using different conventional methods of derivatization. The use of methods based on saponification or base‐catalyzed transesterification resulted in a mixture of double‐bond positional isomers of 18:5. On a SUPELCOWAX 10 column, the equivalent chain length (ECL) value for authentic 18:5n‐3 methyl ester was 20.22, whereas the main component after base‐catalyzed methylation had ECL 20.88. Attempts to prepare N‐acyl pyrrolidides or 4,4‐dimethyloxazoline (DMOX) derivatives of 18:5n‐3 also gave inadequate results. These derivatives also showed a main peak corresponding to isomerized 18:5. Mass spectra for both DMOX and pyrrolidide derivatives of this compound showed the base peak at m/z 139, probably corresponding to 2,6,9,12,15‐18:5 acid. Of all methods tested for methylation, only derivatization with 5% HCl or 1% sulphuric acid in methanol gave satisfactory results. Therefore, GC or GC‐mass spectrometry analyses of algal lipids containing 18:5n‐3 may be inaccurate when base‐catalyzed methods of FA derivatization are applied. The best and simplest way to avoid incorrect GC results is to use standard acid‐catalyzed methylation.  相似文献   

15.
We report the first use of functionalized cadmium selinide quantum dots (CdSe QDs) with 11‐mercaptoundecanoic acid (MUA) as the matrix for the selective ionization of proteins with high resolution and rapid analysis of amino acids and peptides by using quantum dots laser desorption/ionization mass spectrometry (QDLDI‐MS). The mercaptocarboxylic groups of CdSe QDs have been known to be an effective affinity probe to interact with the biomolecules at low abundance level. Using these QDs as the matrix, sensitivity of the method was greatly enhanced and the LOQ of peptides was found to be 100 pM with RSD <10%. The QDLDI‐MS is capable for the selective ionization of insulin, lysozyme and myoglobin with high resolution, which is not observed with sinapic acid (SA) as the matrix. The QDLDI‐MS technique offers many advantages for the analysis of amino acids, peptides and proteins with regard to simplicity, rapidity, sensitivity and the mass spectra were generated in the presence of signal suppressors such as urea and Trition X‐100. In addition, the CdSe QDs have been successfully applied as preconcentrating probes for the analysis of digested peptides in lysozyme from chicken egg white by microwave‐assisted enzymatic digestion. This indicates that the QDs are able to absorb radiation from microwave and their ability to trap peptides from microwave‐digested lysozyme. These results demonstrate that the CdSe QDs are promising candidates for the selective ionization of the analytes with an accurate platform to the rapid screening of biomolecules.  相似文献   

16.
Quantitative proteomics based on MS is useful for pointing out the differences in some food proteomes relevant to human nutrition. Stable isotope label‐free (SIF) techniques are suitable for comparing an unlimited number of samples by the use of relatively simple experimental workflows. We have developed an internal standard label‐free method based on the intensities of peptide precursor ions from MS/MS spectra, collected in data dependent runs, for the simultaneous qualitative characterization and relative quantification of storage proteins of Lupinus albus seeds in protein extracts of four lupin cultivars (cv Adam, Arés, Lucky, Multitalia). The use of an innovative microfluidic system, the HPLC‐Chip, coupled with a classical IT mass spectrometer, has allowed a complete qualitative characterization of all proteins. In particular, the homology search mode has permitted to identify single amino acid substitutions in the sequences of vicilins (β‐conglutin precursor and vicilin‐like protein). The MS/MS sequencing of substituted peptides confirms the high heterogeneity of vicilins according to the peculiar characteristics of the vicilin‐encoding gene family. Two suitable bioinformatics parameters were optimized for the differential analyses of the main bioactive proteins: the “normalized protein average of common reproducible peptides” (N‐ACRP) for γ‐conglutin, which is a homogeneous protein, and the “normalized protein mean peptide spectral intensity” (N‐MEAN) for the highly heterogenous class of the vicilins.  相似文献   

17.
18.
19.
Phosphorylation is one of the most important PTMs and is estimated to occur on 30% of the mammalian proteome. Its perturbed regulation has been implicated in many pathologies. The rarity of phosphotyrosine compared with phosphoserine or phosphothreonine is prompting the development of more sensitive approaches because proteomic technologies that are currently used to assess tyrosine phosphorylation in proteins are inadequate, identifying only a fraction of the predicted tyrosine phosphoproteome. Here we describe the development of a reproducible, high‐sensitivity methodology for the detection and mapping of phosphotyrosine residues by MS. The anti‐phosphotyrosine antibody 4G10 was coupled covalently to super para‐magnetic beads or by affinity to super para‐magnetic beads with protein G covalently attached. Using this approach, we successfully enriched phosphotyrosine peptides mixed with non‐phosphorylated peptides at a ratio of up to 1:200, enabling detection at a level representing the highest sensitivity reported for tyrosine phosphorylation. The beads were subsequently used to enrich tyrosine phosphopeptides from a digest of the in vitro‐phosphorylated recombinant β‐intracellular region of the granulocyte‐macrophage colony‐stimulating factor receptor, which was subsequently analysed by MALDI‐TOF/TOF MS. Our results define this methodology as a sensitive approach for tyrosine phosphoproteome analysis.  相似文献   

20.
The cutin polymers of different fruit cuticles (tomato, apple, nectarine) were examined using matrix‐assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI) after in situ release of the lipid monomers by alkaline hydrolysis. The mass spectra were acquired from each coordinate with a lateral spatial resolution of approximately 100 μm. Specific monomers were released at their original location in the tissue, suggesting that post‐hydrolysis diffusion can be neglected. Relative quantification of the species was achieved by introducing an internal standard, and the collection of data was subjected to non‐supervised and supervised statistical treatments. The molecular images obtained showed a specific distribution of ions that could unambiguously be ascribed to cutinized and suberized regions observed at the surface of fruit cuticles, thus demonstrating that the method is able to probe some structural changes that affect hydrophobic cuticle polymers. Subsequent chemical assignment of the differentiating ions was performed, and all of these ions could be matched to cutin and suberin molecular markers. Therefore, this MALDI‐MSI procedure provides a powerful tool for probing the surface heterogeneity of plant lipid polymers. This method should facilitate rapid investigation of the relationships between cuticle phenotypes and the structure of cutin within a large population of mutants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号