首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Separation of metformin and glibenclamide was achieved within a single chromatographic run on a Zorbax CN column, under isocratic conditions, using acetonitrile and aqueous component (0.01 moles/L ammonium acetate adjusted at pH 3.5 with acetic acid) in volumetric ratio 1/1. Plasma sample preparation is based on protein precipitation by means of organic solvent addition. 1,3,5-Triazine-2,4,6-triamine (IS1) was used as internal standard for metformin, while gliquidone (IS2) played the same role for glibenclamide. Detection was performed with an ion trap mass analyzer, using atmospheric pressure chemical ionization (APCI). A single MS stage was used for detection of metformin and IS1, by extracting ion chromatograms corresponding to molecular ions. MS/MS detection in the SRM mode was used for glibenclamide (m/z transition from 494 to 369 Da) and IS2 (m/z transition from 528 to 403 Da). The method produces linear responses up to 2000 ng/mL for metformin and 400 ng/mL for glibenclamide, respectively. Low limits of quantification were found in the 40 ng/mL range for metformin and at the 4 ng/mL level for glibenclamide. Precision was characterized by relative standard deviations (RSD%) below 9%. The analytical method was successfully applied to a single dose, open-label, randomized, two-period, two-sequence, crossover bioequivalence study of two commercially available anti-diabetic combinations containing 400 mg metformin and 2.5 mg of glibenclamide per coated tablet.  相似文献   

2.
A selective and sensitive high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (ESI-MS/MS) method for simultaneous determination of metformin and rosiglitazone in human plasma using phenformin as internal standard (IS) has been first developed and validated. Plasma samples were precipitated by acetonitrile and the analytes were separated on a prepacked Phenomenex Luna 5u CN 100A (150 mm x 2.0 mm I.D.) column using a mobile phase comprised of methanol:30 mM ammonium acetate pH 5.0 (80:20, v/v) delivered at 0.2 ml/min. Detection was performed on a Finnigan TSQ triple-quadrupole tandem mass spectrometer in positive ion selected reaction monitoring (SRM) mode using electrospray ionization. The ion transitions monitored were m/z 130.27-->71.11 for metformin, m/z 358.14-->135.07 for rosiglitazone and m/z 206.20-->105.19 for the IS. The standard curves were linear (r(2)>0.99) over the concentration range of 5-3000 ng/ml for metformin and 1.5-500 ng/ml for rosiglitazone with acceptable accuracy and precision, respectively. The within- and between-batch precisions were less than 15% of the relative standard deviation. The limit of detection (LOD) of both metformin and rosiglitazone was 1 ng/ml. The method described is precise and sensitive and has been successfully applied to the study of pharmacokinetics of compound metformin and rosiglitazone capsules in 12 healthy Chinese volunteers.  相似文献   

3.
A rapid, sensitive, and highly selective liquid chromatography-tandem mass spectrometry method was developed and validated for simultaneous determination of enalapril and its major active metabolite enalaprilat in human plasma. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Zorbax Extend-C(18) column, and detected by tandem mass spectrometry with a Turbo IonSpray ionization interface. The method has a lower limit of quantification (LLOQ) of 0.1 ng/ml for both enalapril and enalaprilat. The chromatographic run time was approximately 3.5 min. The standard calibration curves for both enalapril and enalaprilat were linear in the concentration ranges of 0.10-100.0 ng/ml in human plasma. The intra- and inter-run precisions, expressed as the relative standard deviation (R.S.D.), were less than 7.7 and 7.8%, determined from QC samples for enalapril and enalaprilat, and accuracy was within +/-3.9 and +/-2.7% in terms of relative error, respectively. The method was successfully applied for the evaluation of the pharmacokinetics of enalapril and enalaprilat in 20 volunteers after an oral dose of 10 mg enalapril maleate.  相似文献   

4.
A rapid and sensitive method to determine colchicine in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed. Colchicine and the internal standard (I.S.), tegafur, were extracted from the matrix with n-hexane:dichloromethane:isopropanol (300:150:15, v/v/v) and separated by reversed-phase high-performance liquid chromatography (HPLC) using formic acid:10 mM ammonium acetate:methanol (1:49:75, v/v/v) as the mobile phase in a run time of 2.5 min. Detection was carried out by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring (MRM) mode. The assay was linear in the concentration range 0.050-10 ng/ml with intra- and inter-day precision (as relative standard deviation (R.S.D.)) of <2 and <7%, respectively. The method was applied to a pharmacokinetic study of colchicine in healthy volunteers given an oral dose of 2.0 mg.  相似文献   

5.
A packed-column supercritical fluid chromatography/atmospheric pressure chemical-ionisation mass spectrometry (pSFC-APCI/MS) method has been developed for the determination of atropine from Atropa belladonna L extracts. The technique does not require any kind of derivatisation prior to the analysis. The optimum conditions were studied by using the pure substance in methanol (MeOH). All samples were simply dissolved in MeOH and injected into the mobile phase. Detection was achieved by using mass spectrometry (MS) with atmospheric pressure chemical ionisation (APCI). Terbutaline was used as an internal standard for the determination of the analytical reproducibility. The supercritical carbon dioxide (scCO(2)) mobile phase was modified by 15% MeOH containing 0.5% trifluoroacetic acid (TFAA) and 0.5% diethylamine (DEA) additives. Concentrations of atropine were determined with a relative standard deviation of less than 1% by the pSFC-APCI/MS procedure for a sample containing atropine and terbutaline. The correlation coefficient was 0.997 and detection limit 700 pg. The absolute retention time was 9.87 min with a standard deviation of 5.2x10(-3) min and a relative standard deviation of 0.61% with respect to terbutaline.  相似文献   

6.
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed to determine meloxicam of low concentration in human plasma. After a simple sample preparation procedure by one-step protein precipitation with methanol, meloxicam and the internal standard piroxicam were chromatographed on a Zorbax SB C(18) column. The mobile phase consisted of acetonitrile-water-formic acid (80:20:0.2, v/v/v). Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via electrospray ionization (ESI) source. The method had a lower limit of quantification of 0.10 ng/ml. The calibration curve was demonstrated to be linear over the concentration range of 0.10-50.0 ng/ml. The assay was specific, accurate (percentage deviations from nominal concentrations were within +/-2.5%), precise (intra- and inter-day relative standard deviation (R.S.D.) <7%). The validated method was successfully applied to the determination of meloxicam in human plasma collected up to 180 h after a transdermal administration of 30 mg meloxicam for evaluation of the pharmacokinetics.  相似文献   

7.
A simple and selective analytical method for the quantitative determination of cyanuric acid, the degradation product of sodium dichloroisocyanurate (NaDCC), in human urine is reported herein. The sample preparation involved the use of diatomaceous earth extraction columns. Quantification was achieved by liquid chromatography mass spectrometry using negative ion electrospray with a cyano (CN) column. Between day relative standard deviation less than 10% (n=6) was obtained at the 5 mg L(-1) level. The assay was linear over the investigated range 0-20 mg L(-1) and the limit of detection (LOD) was confirmed to be 0.1 mg L(-1). The method was applied to monitoring levels of cyanuric acid in healthcare workers using disinfectants products containing NaDCC.  相似文献   

8.
Quantitative analysis of peptides in biological matrices remains a challenging task. This is due to the low dosage and the complexity of both the matrix and the analytical characteristics of peptides. SS-20 is a tetrapeptide compound developed for the treatment of Parkinson's disease. To investigate the pharmacokinetics of SS-20, a sensitive and rapid liquid chromatography coupled with mass spectrometry method was developed and validated. An aliquot of 50 μL plasma sample was extracted via solid phase extraction. The extracts were separated using a hydrophilic interaction liquid chromatography column, and were then detected with a triple quadrupole mass spectrometer using electrospray ionization in positive-ion mode and selected reaction monitoring. The use of a deuterium-labeled internal standard provided acceptable accuracy, precision, and matrix effect. The lower limit of quantification was 0.30 ng/mL. The linear range of the method was from 0.30 to 1000 ng/mL. The intraday and interday precisions were lower than 10.2% in terms of relative standard deviation, and the accuracy was within ±2.1% in terms of relative error. The validated LC-MS/MS method was successfully applied to a pharmacokinetic study of SS-20 following an intravenous or subcutaneous injection administration of 1.0mg/kg to Sprague-Dawley rats.  相似文献   

9.
Betamethasone is a synthetic corticosteroid designed to exert a marked glucocorticoid activity. As the free alcohol, betamethasone finds widespread clinical applications related to its anti-inflammatory and immunosuppressant activity. In the present study, a fast, sensitive, robust method was developed for the determination and quantification of betamethasone in human plasma by liquid chromatography coupled with tandem mass spectrometry, using photospray ionization in negative mode. Betamethasone was extracted from 0.5 ml human plasma by liquid-liquid extraction (LLE) using chloramphenicol as internal standard. The method has a chromatographic run of 2.5 min using a C(18) analytical column (100 mm x 2.1 mm i.d.) and the linear calibration curve over the range was linear from 0.05 to 50 ng ml(-1) (r(2)>0.993). The between-run precision, based on the relative standard deviation replicate quality controls was 94.1% (0.15 ng ml(-1)), 90.7% (4.0 ng ml(-1)) and 97.2% (40 ng ml(-1)). The between-run accuracy for the above-mentioned concentrations was 11.9, 9.0 and 9.8%, respectively. The method herein described was employed in a bioequivalence study of two formulations of dexchlorpheniramine/betamethasone 2 mg/0.25 mg tablets.  相似文献   

10.
We reported a new methodology for the stereoselective determination of metalaxyl enantiomers in tobacco and soil. The QuEChERS (quick, easy, cheap, effective, rugged, and safe) method was used for the extraction and clean-up of the tobacco and soil samples. Separation of the metalaxyl enantiomers was performed on an ACQUITY UPC2 Trefoil CEL1 chiral column coupled with supercritical fluid chromatography with tandem mass spectrometry (SFC-MS/MS), and the run time was only 5 minutes. Under the optimized conditions, the recoveries for the enantiomers were between 78.2% and 93.3% with intraday relative standard deviations (RSDs) ranging from 1.1% to 5.4%. The limit of detection (LOD) for the enantiomers in tobacco and soil varied from 0.005 to 0.007 mg/kg, and the limit of quantitation (LOQ) ranged from 0.017 to 0.020 mg/kg. In this method, only a small amount of methanol was consumed to obtain a rapid stereoselective separation. This proposed method showed good accuracy and precision and might be suitable for fast enantioselective determination of metalaxyl in food and environmental samples. The developed method was further validated by application to the analysis of authentic samples.  相似文献   

11.
Administration of growth hormone (GH) increases muscle mass in F344 x BN rats, but not in Sprague-Dawley (S-D) rats. S-D rats are insulin-resistant and insulin responsiveness is required for the anabolic actions of GH. We hypothesized that correction of insulin resistance with metformin might also restore anabolic effects of GH. Treatment with GH (0.25 or 1.0 mg/kg twice daily for 9 days) had limited anabolic effects, reducing weight gain by 14%, increasing muscle glycogen content by 40% and increasing exercise capacity by 24%, but failing to increase muscle mass or to reduce fat mass. GH also impaired insulin responsiveness and increased visceral fat TNF content of visceral fat by 77%. Metformin enhanced insulin responsiveness in skeletal muscle, but failed to enhance anabolic effects of GH. Rats aged 14 weeks were treated for 21 days with metformin (320 mg/kg/day) and for the last 9 days, with GH (0.25 mg/kg, twice daily). Metformin caused a 2.3-fold increase in insulin-stimulated muscle glucose transport and a 20% reduction in muscle fatty acid oxidation, indicating increased glucose utilization. However, metformin did not augment GH-induced weight reduction. Metformin decreased visceral fat by 22% and subcutaneous fat by 20%, but no decreases were observed in the GH/metformin group. GH increased muscle glycogen by 40%, but the effect was reversed by metformin. VO(2max) was increased 24% by GH and 17% by metformin, but was not elevated in the GH/metformin group. GH increased TNF in visceral fat and the effect was augmented by metformin (144% increase). We conclude that metformin enhances some aspects of insulin responsiveness, but does not enhance anabolic responses to GH. The latter may, in part, be explained by the failure of metformin to prevent GH-induced elevation of TNF in visceral fat.  相似文献   

12.
A sensitive and highly selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed to determine nimodipine in human plasma. The analyte and internal standard nitrendipine were extracted from plasma samples by n-hexane-dichloromethane-isopropanol (300:150:4, v/v/v), and chromatographed on a C(18) column. The mobile phase consisted of methanol-water-formic acid (80:20:1, v/v/v). Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI) source. The method has a limit of quantification of 0.24 ng/ml. The linear calibration curves were obtained in the concentration range of 0.24-80 ng/ml. The intra- and inter-day precisions were lower than 4.4% in terms of relative standard deviation (R.S.D.), and the accuracy ranged from 0.0 to 5.8% in terms of relative error (RE). This validated method was successfully applied for the evaluation of pharmacokinetic profiles of nimodipine tablets administered to 18 healthy volunteers.  相似文献   

13.
A rapid and sensitive liquid chromatography-tandem mass spectrometric (LC-MS-MS) method for the determination of metformin in human plasma using phenformin as internal standard has been developed and validated. Sample preparation of plasma involved acidification with acetic acid, deproteination with acetonitrile and washing with dichloromethane. Samples were then analyzed by HPLC on a short Nucleosil C18 column (5 microm, 50 mm x 4.6 mm i.d.) using a mobile phase consisting of acetonitrile:methanol:10mM ammonium acetate pH 7.0 (20:20:60, v/v/v) delivered at 0.65 ml/min. Detection was performed using an Applied Biosystems Sciex API 4000 mass spectrometer set at unit resolution in the multiple reaction monitoring (MRM) mode. Atmospheric pressure chemical ionization (APCI) was used for ion production. The assay was linear over the range 1-2000 ng/ml with intra- and inter-day precision of <8.6% and accuracy in the range 91-110%. The limit of detection was 250 pg/ml in plasma. The method was successfully applied to a clinical pharmacokinetic study of an extended-release tablet of metformin hydrochloride (500 mg) administered as a single oral dose.  相似文献   

14.
A selective and sensitive method has been developed and validated for simultaneous quantification of methylephedrine and noscapine in human plasma. Analytes were extracted from human plasma samples by liquid-liquid extraction, separated on a Diamonsil C18 column and detected by tandem mass spectrometer with an atmospheric pressure chemical ionization (APCI) interface. Diphenhydramine was used as the internal standard (I.S.). The method was found to be precise and accurate within the linear range 0.1-100 ng/ml for each analyte. The intra- and inter-day relative standard deviations (R.S.D.s) were below 5.2% for methylephedrine and 6.7% for noscapine. The inter-day relative error (RE) as determined from quality control samples (QCs) was less than 3.0% for each analyte. The assay was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation containing 20 mg DL-methylephedrine hydrochloride, 16 mg noscapine, 300 mg paracetamol and 1mg of chlorpheniramine maleate.  相似文献   

15.
We have developed a gas chromatography–high resolution mass spectrometry method for measuring pyrethroid, organophosphorus, carbamate and fipronil pesticides and the synergist piperonyl butoxide in human plasma. Plasma samples were extracted using solid phase extraction and were then concentrated for injection and analysis using isotope dilution gas chromatography–high resolution mass spectrometry. The limits of detection ranged from 10 to 158 pg/mL with relative recoveries at concentrations near the LODs (e.g., 25 or 250 pg/mL) ranging from 87% to 156% (9 of the 16 compounds were within ±15% of 100%). The extraction recoveries ranged from 20% to 98% and the overall method relative standard deviations were typically less than 20% with some exceptions. Analytical characteristics were determined at 25, 250, and 1000 pg/mL.  相似文献   

16.
Dronedarone is a derivative of amiodarone--a popular antiarrhythmic drug. It was developed to overcome the limiting iodine-associated toxicities of amiodarone. Debutyldronedarone is a major circulating active metabolite of dronedarone in humans. To investigate the pharmacokinetics of dronedarone, a rapid, simple, and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to simultaneously determine dronedarone and debutyldronedarone in human plasma using amiodarone as internal standard (IS). Acetonitrile with IS was used to precipitate proteins from a 50-μL aliquot of plasma. Effective chromatographic separation was performed on a CAPCELL PAK C(18) MG (100 mm × 4.6 mm, 5 μm) column with gradient elution (5 mmol/L ammonium acetate-acetonitrile, with each phase containing 0.2% acetic acid) at a flow rate of 0.7 mL/min. Complete separation was achieved within 5.5 min. Detection was carried out on an tandem mass spectrometer in multiple reaction monitoring mode using a positive atmospheric pressure chemical ionization interface. A lower limit of quantification of 0.200 ng/mL was achieved for both dronedarone and debutyldronedarone, with acceptable precision and accuracy. The linear range of the method was from 0.200 to 200 ng/mL for each analyte. Intra- and inter-day precisions were lower than 7.2% in relation to relative standard deviation, while accuracy was within ±5.1% in terms of relative error for analytes. Our findings demonstrate the successful application of the validated LC-MS/MS method to a pharmacokinetic study after a single oral administration of 400mg dronedarone to six healthy volunteers.  相似文献   

17.
A simplified method to determine clarithromycin concentrations in human plasma using protein precipitation in a 96-well plate and liquid chromatography-tandem mass spectrometry was developed and validated. Plasma proteins were precipitated with acetonitrile and roxithromycin was used as the internal standard. After vortex mixing and centrifugation, the supernatants were directly injected onto a Phenomenex Luna Phenyl-Hexyl column (50 mm x 2.0 mm ID, 3 microm). The mobile phase consisted of water and methanol (30:70, v/v) containing 0.1% formic acid and 5mM ammonium acetate. The flow rate was 0.22 mL/min and the total run time (injection to injection) was less than 3 min. Detection of the analytes was achieved using positive ion electrospray tandem mass spectrometry in selected reaction monitoring (SRM) mode. The linear standard curve ranged from 100 to 5000 ng/mL and the precision and accuracy (inter- and intra-run) were within 7.9% and 4.9%, respectively. The method was successfully used to determine clarithromycin concentrations in human plasma samples obtained from healthy subjects who were given clarithromycin 500 mg for 3 days. The method is rapid, simple, precise and directly applicable to clarithromycin pharmacokinetic studies.  相似文献   

18.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of rivastigmine in human plasma. Rivastigmine was extracted from human plasma by using solid-phase extraction technique. Zolpidem was used as the internal standard. A Betabasic-8 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 251.20-->206.10, 86.20 for rivastigmine and m/z 308.10-->235.10 for zolpidem. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatographic conditions and mass spectrometric detection that enables detection at sub-nanogram levels. The proposed method has been validated for a linear range of 0.2-20.0 ng/ml with a correlation coefficient > or =0.9988. The intra-run and inter-run precision and accuracy were within 10.0%. The overall recoveries for rivastigmine and zolpidem were 86.28% and 87.57%, respectively. The total run time was 2.0 min. The developed method was applied for the determination of the pharmacokinetic parameters of rivastigmine following a single oral administration of a 3 mg rivastigmine capsule in 20 healthy male volunteers.  相似文献   

19.
A rapid and reliable electrospray tandem mass spectrometric method for soluble epoxide hydrolase (sEH) inhibitors in rat hepatic microsomes is described. Four synthesized sEH inhibitors were extracted from rat hepatic microsomes with ethyl acetate and were determined by HPLC using positive ion electrospray tandem mass spectrometry within 7 min. The relationship between signal intensity and concentration of sEH inhibitors was linear over the concentration range of 2.0 to 500 ng/mL per 5-microL injection with the use of a noncoeluting internal standard with a similar chemical structure. The intraassay precision was less than 12.4% relative standard deviation and accuracy ranged from -7.0 to 11.3% deviation from the theoretical values with five duplicate assays. The recovery of sEH inhibitors from rat hepatic microsomes, fortified at levels of 50, 100, and 250 ng/mL, averaged 74.2-107.7% with a RSD of 2.1-7.6%. This method was successfully applied to the quantification of residual sEH inhibitors in rat hepatic microsomes without interference.  相似文献   

20.
Meloxicam was quantified in human plasma after a single 15 mg oral dose of the drug was given to 26 healthy volunteers. An Applied Biosystems Sciex API 2000 triple quadrupole mass spectrometer in multiple reaction monitoring (MRM) mode, using TurboIonSpray (TIS) in the positive ion mode, was used. Protein precipitation with acetonitrile was followed by C(18) reverse phase liquid chromatography and tandem mass spectrometry. The mean recovery for meloxicam was 92% with a lower limit of quantification of 8.96 ng/ml. Piroxicam was used as the internal standard. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometry (MS-MS) detection to allow for a more rapid (extraction and chromatography) and selective method for the determination of meloxicam in human plasma than has previously been described.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号