首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A simple and sensitive column-switching high-performance liquid chromatographic method was developed for the simultaneous determination of omeprazole and its two main metabolites, 5-hydroxyomeprazole and omeprazole sulfone, in human plasma. Omeprazole, its two metabolites and lansoprazol as an internal standard were extracted from 1 ml of alkalinized plasma sample using diethyl ether-dichloromethane (45:55, v/v). The extract was injected into a column I (TSK-PW precolumn, 10 microm, 35 mm x 4.6 mm i.d.) for clean-up and column II (Inertsil ODS-80A column, 5 microm, 150 mm x 4.6mm i.d.) for separation. The mobile phase consisted of phosphate buffer-acetonitrile (92:8 v/v, pH 7.0) for clean-up and phosphate buffer-acetonitrile-methanol (65:30:5 v/v/v, pH 6.5) for separation, respectively. The peak was detected with an ultraviolet detector set at a wavelength of 302 nm, and total time for chromatographic separation was approximately 25 min. The validated concentration ranges of this method were 3-2000 ng/ml for omeprazole, 3-50 ng/ml for 5-hydroxyomeprazole and 3-1000 ng/ml for omeprazole sulfone. Mean recoveries were 84.3% for omeprazole, 64.3% for 5-hydroxyomeprazole and 86.1% for omeprazole sulfone. Intra- and inter-day coefficient variations were less than 5.1 and 6.6% for omeprazole, 4.6 and 5.0% for 5-hydroxyomeprazole and 4.6 and 4.9% for omeprazole sulfone at the different concentrations. The limits of quantification were 3 ng/ml for omeprazole and its metabolites. This method was suitable for use in pharmacokinetic studies in human volunteers, and provides a useful tool for measuring CYP2C19 activity.  相似文献   

3.
A high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI/MS) method for simultaneous stereoselective analysis of venlafaxine (VEN) and its major metabolite O-desmethylvenlafaxine (ODV) enantiomers in human plasma has been developed and validated. Chiral chromatography is performed on the CHRIOBIOTIC V (5 microm, 250 mm x 4.6 mm) column with mobile phase constituted of 30 mmol/l ammonium acetate-methanol (15:85, pH 6.0) at a flow rate of 1.0 ml/min and a postcolumn splitting ratio of 3:1. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and detected using the selected ion recording (SIR) mode. Calibration curves obtained from spiked plasma were linear in the range of 5.0-400 ng/ml for S-(+)-VEN and R-(-)-VEN, 4.0-280 ng/ml for S-(+)-ODV and R-(-)-ODV, respectively, with linear correlation coefficient all above 0.999. The average extraction recoveries for all the four analytes were above 76%. The methodology recoveries were higher than 92%. The limit of detection were 1.0 ng/ml for S-(+)-VEN and R-(-)-VEN, 1.5 ng/ml for S-(+)-ODV and R-(-)-ODV, respectively. The intra- and inter-day variation coefficients were less than 9%.  相似文献   

4.
A sensitive stereoselective bioanalytical liquid chromatographic assay with mass spectrometric detection (LC-MS) was developed and validated for the on-line extraction and quantification of R- and S-methadone and the primary metabolite R- and S-2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) from human plasma. Deproteinized plasma was injected directly onto a small C8 column, washed and then back-flushed using a column switching valve and a second pump onto an alpha1-acid glycoprotein analytical column, and enantioselective separation achieved using a mobile phase gradient of methanol and ammonium formate. Analytes were validated over a range of 0.1-25 ng/ml R- and S-EDDP and 0.1-100ng/ml R- and S-methadone, respectively. Unweighted standard curves were linear over this concentration range (regression coefficients > 0.999). Quality control samples were evaluated at 1, 5, 12.5 ng/ml R- and S-EDDP and 1, 10, 50 ng/ml R- and S-methadone. Intra- and inter-day accuracy was >95%, and intra- and inter-day coefficients of variation were less than 10% for all analytes and concentrations. This assay represents the only method currently available which combines on-line extraction and achieves chiral separation of both methadone and EDDP from plasma, and offers improvements in sensitivity over existing methods.  相似文献   

5.
It has been demonstrated that the formation of the hydrophilic metabolites of dexamethasone, 6 alpha- and 6 beta-hydroxydexamethasone, correlated with cytochrome P450 (CYP) 3A4 enzyme levels. So, the 6 beta-hydroxydexamethasone/dexamethasone urinary ratio could be a specific marker for human CYP3A4 activity. We have developed a sensitive and specific high-performance liquid chromatographic method for the simultaneous quantification of urinary free dexamethasone and 6 beta-hydroxydexamethasone using 6 alpha-methylprednisolone as internal standard. This method involved a solid phase extraction of the three compounds from urine using Oasis HLB Waters cartridges with an elution solvent of ethyl acetate (2 ml) followed by diethyl ether (1 ml). Separation of the three analytes was achieved within 24 min using a reversed-phase Nova-Pak C(18) analytical column (4 microm, 300 mm x 3.9 mm i.d.). An ultraviolet detector operated at 245 nm was used with a linear response observed from 10 to 100 ng/ml for dexamethasone and from 25 to 1000 ng/ml for 6 beta-hydroxydexamethasone. Obtained from the method validation, inter-assay precision was below 15% and accuracy ranged from 95.7 to 110%. The extraction efficiency of the assay was approximately of 99% and was constant across the calibration range. The lower limit of quantitation was 10 ng/ml for dexamethasone and 25 ng/ml for 6 beta-hydroxydexamethasone; at these levels, precision was below 16% and accuracy was 99-109%. This method was applied to in vivo measure of the CYP3A4 activity.  相似文献   

6.
An analytical method has been developed for the simultaneous determination of a novel orally active angiotensin-converting enzyme inhibitor (CGS 16617) and a stable isotope-labeled analog. Both compounds are isolated from human plasma using an ion-exchange column, derivatized with pentafluoropropionic anhydride and pentafluoropropanol, and analyzed by gas chromatography/mass spectrometry. After splitless injection on a methyl-silicon column, the compound is detected using negative ion chemical ionization with nitrous oxide as a reagent gas. CGS 16617 labeled with four deuteriums and two 13C is used as an internal standard. The accuracy and precision of the method, expressed as the overall mean +/- SD recovery obtained from two sets of 36 quality-control samples used during a clinical study (concentration range 0.2-100 ng ml-1 plasma), was 96.1 +/- 16.2% for unlabeled drug and 97.6 +/- 14.4% for the D4-labeled drug (concentration range 0.2-100 ng ml-1 plasma). The limit of quantification using 1 ml plasma is 0.2 ng ml-1 for both labeled and unlabeled drug.  相似文献   

7.
A simple high-performance liquid chromatography (HPLC)-tandem mass spectrometric method has been developed for determination of propiverine hydrochloride and its metabolite, propiverine N-oxide (M-1) in human plasma using stable isotopes, propiverine hydrochloride-d10 and M-1-d10, as internal standards. The analytes were extracted with dichloromethane from 0.2 ml of plasma in neutral condition (pH 7.0) and separated by HPLC on a C18 reversed-phase column using methanol-1% acetic acid (50:50) as a mobile phase, and detected using positive electrospray ionization in selected reaction monitoring (SRM) mode. The method was validated over a concentration range of 2-500 ng/ml for propiverine hydrochloride and 4-1000 ng/ml for M-1 using 0.2 ml of human plasma per assay. The method developed was successfully applied to analysis of propiverine hydrochloride and M-1 in clinical studies.  相似文献   

8.
A high-performance liquid chromatography method with diode array detection (HPLC-DAD) was developed for quantification of aripiprazole and dehydro-aripiprazole, in human plasma. After a simple liquid-liquid extraction, chromatographic separation was carried out on a C18 reversed-phase column, using an ammonium buffer-acetonitrile mobile phase (40:60, v/v). The total run time was only 7 min at a flow-rate of 1.0 ml/min. The precision values were less than 12% and the accuracy values were ranging from 98 to 113% and the lower limit of quantification was 2 ng/ml for both compounds. Calibration curves were linear over a range of 2-1000 ng/ml. The mean trough plasma concentrations in patients treated with aripiprazole were 157 and 29 ng/ml for aripiprazole and dehydro-aripiprazole, respectively.  相似文献   

9.
An enantioselective assay for S-(-)- and R-(+)-propranolol in transgenic Chinese hamster CHL cell lines, expressing human cytochrome P450 (CYP), was developed. The method involves extraction of propranolol from the S(9) incubates, using S-(+)-propafenone as internal standard, chiral derivatization with 2,3,4,6-tetra-O-beta-D-glucopranosyl isothiocyanate and quantitation by reversed phase high-performance liquid chromatography system with UV detection (lambda=220 nm). A baseline separation of propranolol enantiomers was achieved on a 5-microm reverse-phase ODS column, with a mixture of methanol/water/glacial acetic acid (67:33:0.05, v/v) as mobile phase. The assay is linear from 5 to 500 microM for each enantiomer. The analytical method affords average recoveries of 99.2% and 98.8% for S-(-)- and R-(+)-propranolol, respectively. The limit of quantitation for the method is 5 microM for both S-(-)- and R-(+)-propranolol. The reproducibility of the assay is satisfactory (RSD < 10%). The method allowed study of the depletion of S-(-)- and R-(+)-propranolol in transgenic Chinese hamster CHL cell lines expressing CYP3A4, CYP2C18 and CYP2C9.  相似文献   

10.
A sensitive method was developed for the simultaneous determination of omeprazole and its major metabolites 5-hydroxyomeprazole and omeprazole sulfone in human plasma by HPLC-electrospray mass spectrometry. Following liquid-liquid extraction HPLC separation was achieved on a ProntoSil AQ, C18 column using a gradient with 10 mM ammonium acetate in water (pH 7.25) and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH(+) ions, m/z 346 for omeprazole, m/z 362 for 5-hydroxy-omeprazole and omeprazol-sulfone and m/z 300 for the internal standard (2-{[(3,5-dimethylpyridine-2-yl)methyl]thio}-1H-benzimidazole-5-yl)methanol. The limit of quantification (LOQ) achieved with this method was 5 ng/ml for 5-hydroxyomeprazole and 10 ng/ml for omeprazole and omeprazole-sulfone using 0.25 ml of plasma. Intra- and inter-assay variability was below 11% over the whole concentration range from 5 to 250 ng/ml for 5-hydroxyomeprazol and from 10 to 750 ng/ml for omeprazole and omeprazole-sulfone. The method was successfully applied to the determination of pharmacokinetic parameters of esomeprazole and the two major metabolites after a single dose and under steady state conditions.  相似文献   

11.
The method presented here is a high-performance liquid chromatography (HPLC)-UV detection method for the determination of baclofen R-(-)- and S-(+)-enantiomers in human plasma using a chiral separation technique. Baclofen enantiomers were extracted from human plasma with a reversed-phase solid-phase extraction (SPE) cartridge. The extract was then injected onto a HPLC system with a UV detection system set at 220 nm. The separation was achieved by using a 150x4.6 mm, 5 microm Phenomenex chirex 3216 chiral column with a mobile phase consisting of 0.4 mM CuSO(4) in acetonitrile-20 mM sodium acetate (17:83). The calibration curves were linear for both R-(-)- and S-(+)-enantiomers of baclofen in the concentration range of 20-5000 ng/ml. The average regressions were 0.9980 and 0.9991 for R-(-)- and S-(+)-baclofen, respectively. Inter-day precision was 3.3-5.2% for R-(-)-baclofen and 3.5-3.9% for S-(+)-baclofen at a concentration range of 60-4000 ng/ml. Intra-day precisions were 0.6-4.4 and 0.5-3.5% for R-(-)-baclofen and S-(+)-baclofen, respectively. The average extraction recovery was 81.6% for R-(-)-baclofen, 83.0% for S-(+)-baclofen and 94.0% for the internal standard (p-aminobenzoic acid). The limit of quantitation for both R-(-)- and S-(+)-baclofen in human plasma was 20 ng/ml. The method is simple and easy to operate with accuracy and reproducibility and it is suitable for pharmacokinetic studies.  相似文献   

12.
A novel HPLC-UV method was developed for the simultaneous determination of timolol (TM), rosuvastatin (RST), and diclofenac sodium (DS) in pharmaceuticals, human plasma and aqueous humor using naproxen sodium as internal standard (IS). The target compounds were analyzed on Hypersil BDS C(18) column (250 mm × 4.6 mm, 5 μm), applying 0.2% triethylamine (TEA) and acetonitrile (ACN) (40:60, v/v), in isocratic mode as mobile phase, pH 2.75 adjusted with 85% phosphoric acid at a flow rate of 1 ml/min. The column oven temperature was kept at 45°C and the peak response was monitored at 284 nm after injecting a 50 μl sample into HPLC system. The direct liquid-liquid extraction procedure was applied to human plasma and bovine aqueous humor samples using mobile phase as an extraction solvent after deproteination with methanol. The different HPLC experimental parameters were optimized and the method was validated according to standard guidelines. The recoveries of the suggested method in human plasma were 98.72, 96.04, and 95.14%, for TM, RST, and DS, while in aqueous humor were 94.99, and 98.23%, for TM, and DS, respectively. The LOD values were found to be 0.800, 0.500, and 0.250 ng/ml, for TM, RST, and DS, respectively, while their respective LOQ values were 2.00, 1.50, and 1.00 ng/ml. The co-efficient of variation (CV) were in the range of 0.1492-1.1729% and 1.0516-4.0104%, for intra-day and inter-day studies, respectively. The method was found accurate in human plasma and bovine aqueous humor and will be applied for the quantification of these compounds in plasma, and aqueous humor samples using animal models and in pharmaceuticals.  相似文献   

13.
A high-performance liquid chromatographic method has been developed for the determination of pipotiazine in human plasma and urine. After selective extraction, pipotiazine and the internal standard (7-methoxypipotiazine) are chromatographed on a column packed with Spherosil XOA 600 (5 μm) using a 7:3 (v/v) mixture of diisopropyl ether—isooctane (1:1, v/v) + 0.2% triethylamine and diisopropyl ether—methanol (1:1, v/v) + 0.2% triethylamine + 2.6% water. The eluted compounds are measured by fluorescence detection. The sensitivity of the method was established at 0.25 ng/ml pipotiazine in plasma and 2 ng/ml pipotiazine in urine (C.V. < 5%). The method has been successfully applied to a pharmacokinetic study following a single oral administration of 10 mg of pipotiazine.  相似文献   

14.
The novel compound methyl-1-(3,4-dimethoxyphenyl)-3-(3-ethylvaleryl)-4-hydroxy-6,7,8-trimethoxy-2-naphthoate (S-8921) has hypocholesterolemic activity in animals and is expected to exhibit a similar activity in human. Reversed-phase high-performance liquid chromatography (HPLC) separation followed by radioimmunoassay (RIA) for human plasma samples (HPLC–RIA) and immunoaffinity extraction (IAE) followed by RIA for human urine samples (IAE–RIA) were developed for investigation of S-8921 behavior in clinical studies. For the RIA, antisera from rabbit and a radioiodine-labelled S-8921 were prepared by immunizing a conjugate of S-8921 with bovine serum albumin and by the Bolton and Hunter method, respectively. HPLC–RIA using a semi-micro column was very sensitive, that is a 0.05 ng/ml limit of quantitation in human plasma, and specific for unchanged form of S-8921. IAE–RIA using a centrifugal filtration tube completely eliminated the matrix effect of human urine, and was very feasible. The limit of quantitation was 0.10 ng/ml. RIA detection following HPLC or IAE proved to be very useful for the pharmaceutical analysis of extremely low drug concentrations in body fluids.  相似文献   

15.
Bombesin (BN) and its mammalian equivalent, gastrin-releasing peptide (GRP), stimulate cell proliferation and are involved in the pathogenesis of several types of human cancer. BN/GRP and their receptors were shown to be critical for the growth of various human malignancies, such as small-cell lung, prostate, ovary, stomach and breast cancers in the human tumor xenograft model. In the present study, a fast, sensitive, robust method was developed for the determination and quantification of a BN/GRP receptor antagonist RC-3095 (D-Tpi-Gln-Trp-Ala-Val-Gly-His-Leupsi(CH2NH)Leu-NH2), in human plasma by liquid chromatography coupled with tandem mass spectrometry. RC-3095 was extracted from 0.2 ml human plasma by protein precipitation using cold acetonitrile (0.4 ml). The method has a chromatographic run of 10 min using a C(8) analytical column (150 mm x 4.6 mm i.d.) and the linear calibration curve over the range was linear from 20 to 10000 ng ml(-1) (r(2)>0.994). The between-run precision, based on the relative standard deviation replicate quality controls, was 5.7% (60 ng ml(-1)), 7.1% (600 ng ml(-1)) and 6.8% (8000 ng ml(-1)). The between-run accuracy was +/-0.0, 2.1 and 3.1% for the above-mentioned concentrations, respectively. The developed procedure allows the quantitative determination of peptide RC-3095 for pharmacokinetics studies in human plasma.  相似文献   

16.
A practical and selective HPLC method for the separation and quantification of omeprazole enantiomers in human plasma is presented. C18 solid phase extraction (SPE) cartridges were used to extract the enantiomers from plasma samples and the chiral separation was carried out on a Chiralpak AD column protected with a CN guard column, using ethanol:hexane (70:30) as the mobile phase, at a flow rate of 0.5 ml/min. The detection was carried out at 302 nm. The method proved to be linear in the range of 10-1000 ng/ml for each enantiomer, with a quantification limit of 5 ng/ml. Precision and accuracy, demonstrated by within-day and between-day assays, were lower than 10%.  相似文献   

17.
This paper describes sensitive and reliable determination of midazolam (MDZ) and its major metabolite 1'-hydroxymidazolam (1-OHMDZ) in human plasma by liquid chromatography-mass spectrometry (LC-MS) with a sonic spray ionization (SSI) interface. MDZ, 1-OHMDZ and diazepam as an internal standard were extracted from 1ml of alkalinized plasma using n-hexane-chloroform (70:30, v/v). The extract was injected into an analytical column (YMC-Pak Pro C(18), 50mmx2.0mmi.d.). The mobile phase for separation consisted of 10mM ammonium acetate and methanol (50:50, v/v) and was delivered at a flow-rate of 0.2ml/min. The drift voltage was 100V. The sampling aperture was heated at 120 degrees C and the shield temperature was 260 degrees C. The total time for chromatographic separation was less than 16min. The validated concentration ranges of this method were 0.25-50ng/ml for both MDZ and 1-OHMDZ. Mean recoveries were 93.6% for MDZ and 86.6% for 1-OHMDZ. Intra- and inter-day coefficient variations were less than 6.5 and 5.5% for MDZ, and 6.1 and 5.7% for 1-OHMDZ at 0.3, 4, 20 and 40ng/ml. The limits of quantification were 0.25ng/ml for both MDZ and 1-OHMDZ. This method was sensitive and reliable enough for pharmacokinetic studies on healthy volunteers, and was applied for the measurement of CYP3A activity in humans after an intravenous (1mg) and a single-oral administration (2mg) of subtherapeutic MDZ dose.  相似文献   

18.
A rapid and specific HPLC method has been developed and validated for simultaneous determination of clobazam, the anticonvulsant agent, and its major metabolite in human plasma. The sample preparation was a liquid-liquid extraction with tuloene yielding almost near 100% recoveries of two compounds. Chromatographic separation was achieved with a Chromolith Performance RP-18e 100 mm x 4.6mm column, using a mixture of a phosphate buffer (pH 3.5; 10mM)-acetonitrile (70:30, v/v), in isocratic mode at 2 ml/min at a detection wave-length of 228 nm. The calibration curves were linear (r(2)>0.998) in the concentration range of 5-450 ng ml(-1). The lower limit of quantification was 5 ng ml(-1) for two compounds studied. The within- and between-day precisions in the measurement of QC samples at four tested concentrations were in the range of 0.89-9.1% and 2.1-10.1% R.S.D., respectively. The developed procedure was applied to assess the pharmacokinetics of clobazam and its major metabolite following administration of a single 10mg oral dose of clobazam to healthy volunteers.  相似文献   

19.
We present a new simple and reliable HPLC method for measuring omeprazole and its two main metabolites in plasma. This can be used for studying CYP2C19 and CYP3A4 genetic polymorphisms using omeprazole as the probe drug. Omeprazole, hydroxyomeprazole and omeprazole sulfone were extracted from plasma samples with phosphate buffer and dichloromethane-ether (95:5). HPLC separation was achieved using an Ultrasphere ODS C(18) (Beckman) column. The mobile phase was acetonitrile-phosphate buffer (24:76, pH 8), containing nonylamine at 0.015%. Retention times were 9.5 min for omeprazole, 3.25 min for hydroxyomeprazole, 7.4 min for omeprazole sulfone and 6.27 min for internal standard (phenacetine). Detection (UV at 302 nm) of analytes was linear in the range from 96 to 864 ng/ml. This is useful for calculating metabolic index for CYP2C19 and CYP3A4 in adults and children. This method is stable, reproducible, improves resolution and has practical advantages such as low cost.  相似文献   

20.
Betamethasone is a synthetic corticosteroid designed to exert a marked glucocorticoid activity. As the free alcohol, betamethasone finds widespread clinical applications related to its anti-inflammatory and immunosuppressant activity. In the present study, a fast, sensitive, robust method was developed for the determination and quantification of betamethasone in human plasma by liquid chromatography coupled with tandem mass spectrometry, using photospray ionization in negative mode. Betamethasone was extracted from 0.5 ml human plasma by liquid-liquid extraction (LLE) using chloramphenicol as internal standard. The method has a chromatographic run of 2.5 min using a C(18) analytical column (100 mm x 2.1 mm i.d.) and the linear calibration curve over the range was linear from 0.05 to 50 ng ml(-1) (r(2)>0.993). The between-run precision, based on the relative standard deviation replicate quality controls was 94.1% (0.15 ng ml(-1)), 90.7% (4.0 ng ml(-1)) and 97.2% (40 ng ml(-1)). The between-run accuracy for the above-mentioned concentrations was 11.9, 9.0 and 9.8%, respectively. The method herein described was employed in a bioequivalence study of two formulations of dexchlorpheniramine/betamethasone 2 mg/0.25 mg tablets.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号