首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Microdialysis sampling is a diffusion-based separation method that allows analytes to freely diffuse across a hollow fiber semi-permeable dialysis membrane. This sampling technique has been widely used for in vivo chemical collection. The inclusion of affinity-based trapping agents into the microdialysis perfusion fluid serves to improve the relative recovery via the binding reaction of low molecular weight hydrophobic analytes and larger analytes such as peptides and proteins. Here, we briefly review our past studies using different compounds (native cyclodextrins and antibodies) to improve microdialysis sampling recovery. A brief compilation of our studies using antibody-immobilized beads as a means to improve cytokine collection during microdialysis sampling is also described. We present new work focused on the use of antibody-immobilized bead microdialysis sampling enhancement for various endocrine hormones (amylin, GLP-1, glucagon, insulin, and leptin). The antibody-bead enhancement approach allowed for recovery enhancements that ranged between 3 and 20-fold for these peptides. Using the enhanced recovery approach, endocrine peptides at pM concentrations can be quantified. Finally, our initial work focused on developing non-antibody based enhancement agents using bovine serum albumin-heparin conjugates covalently bound to polystyrene microspheres is presented for the cytokine, tumor necrosis factor-alpha (TNF-alpha). Unlike antibodies, heparin provides the advantage of being reusable as an enhancement agent and served to improve the relative recovery of TNF-alpha by three-fold.  相似文献   

2.
The objective of this review is to emphasize the application of separation science in evaluating the blood-brain barrier (BBB) permeability to drugs and bioactive agents. Several techniques have been utilized to quantitate the BBB permeability. These methods can be classified into two major categories: in vitro or in vivo. The in vivo methods used include brain homogenization, cerebrospinal fluid (CSF) sampling, voltametry, autoradiography, nuclear magnetic resonance (NMR) spectroscopy, positron emission tomography (PET), intracerebral microdialysis, and brain uptake index (BUI) determination. The in vitro methods include tissue culture and immobilized artificial membrane (IAM) technology. Separation methods have always played an important role as adjunct methods to the methods outlined above for the quantitation of BBB permeability and have been utilized the most with brain homogenization, in situ brain perfusion, CSF sampling, intracerebral microdialysis, in vitro tissue culture and IAM chromatography. However, the literature published to date indicates that the separation method has been used the most in conjunction with intracerebral microdialysis and CSF sampling methods. The major advantages of microdialysis sampling in BBB permeability studies is the possibility of online separation and quantitation as well as the need for only a small sample volume for such an analysis. Separation methods are preferred over non-separation methods in BBB permeability evaluation for two main reasons. First, when the selectivity of a determination method is insufficient, interfering substances must be separated from the analyte of interest prior to determination. Secondly, when large number of analytes is to be detected and quantitated by a single analytical procedure, the mixture must be separated to each individual component prior to determination. Chiral separation in particular can be essential to evaluate the stereo-selective permeation and distribution of agents into the brain. In conclusion, the usefulness of separation methods during BBB permeability evaluation is immense and more application of these methods is foreseen in the future.  相似文献   

3.
微透析校正的相关问题和方法   总被引:9,自引:0,他引:9  
微透析技术是研究生物动态变化的一种新型的活体生物采样技术,近年来由于实验方法的不断改进,微透析技术已广泛应用于在体的定量研究。在进行生物细胞外液的定量研究中,微透析探针的校正是十分必要的。本从微透析的回收率、影响因素及校正方法等方面简要介绍了微透析校正的相关问题。  相似文献   

4.
Cytokines are proteins that mediate communication between cells of the immune system as well as certain other non-immune host cells. These proteins are produced by many cell types and they mediate immune and inflammatory responses. However, the direct site analysis of these critical proteins is hampered by the lack of site-specific tools available for such direct measurements. In this study, both in vitro and in vivo microdialysis sampling of different cytokines (tumor necrosis factor-alpha [TNF-alpha], interferon-gamma [IFN-gamma], interleukin-6 [IL-6], IL-12p70, and macrophage chemoattractant protein-1 [MCP-1]) was performed. A mouse model of bacterial lipopolysaccharide (LPS) administration and response pattern was used for in vivo studies. Three cytokines, TNF-alpha, IL-6, and MCP-1 were quantified in the serum from mice given LPS. In vivo studies demonstrated the ability to monitor increasing levels of these cytokines (TNF-alpha, IL-6, and MCP-1) via microdialysis probes placed in the peritoneal cavity of mice given LPS. All three cytokines were quantified simultaneously in 15 muL of dialysate using a multiplexed bead-based immunoassay for flow cytometry. The detected dialysate cytokine concentrations varied between 200 pg/mL and 1500 pg/mL for TNF-alpha, between 600 pg/mL and 3000 pg/mL for MCP-1, and between 2700 pg/mL and more than 5000 pg/mL for IL-6. The detected serum cytokine concentrations ranged from 5700 pg/mL to 35,000 pg/mL for TNF-alpha, from 40,000 pg/mL to 65,000 pg/mL for MCP-1, and greater than than 100,000 pg/mL for IL-6. This work demonstrates that microdialysis sampling can be used in vivo to collect temporal profiles of cytokine production.  相似文献   

5.
The present study compared two different in vivo microdialysis methods which estimate the extracellular concentration of analytes at a steady state where there is no effect of probe sampling efficiency. Each method was used to estimate the basal extracellular concentration of dopamine (DA) in the nucleus accumbens of the rat. In the first method, DA is added to the perfusate at concentrations above and below the expected extracellular concentration (0, 2.5, 5, and 10 nM) and DA is measured in the dialysate from the brain to generate a series of points which are interpolated to determine the concentration of no net flux. Using this method, basal DA was estimated to be 4.2 +/- 0.2 nM (mean +/- SEM, n = 5). The slope of the regression gives the in vivo recovery of DA, which was 65 +/- 5%. This method was also used to estimate a basal extracellular 3,4-dihydroxyphenylacetic acid (DOPAC) concentration in the nucleus accumbens of 5.7 +/- 0.6 microM, with an in vivo recovery of 52 +/- 11% (n = 5). A further experiment which extended the perfusate concentration range showed that the in vivo recovery of DA is significantly higher than the in vivo recovery of DOPAC (p less than 0.001), whereas the in vitro recoveries of DA and DOPAA are not significantly different from each other. The in vivo difference is thought to be caused by active processes associated with the DA nerve terminal, principally release and uptake of DA, which may alter the concentration gradient in the tissue surrounding the probe.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
Leegsma-Vogt G  Janle E  Ash SR  Venema K  Korf J 《Life sciences》2003,73(16):2005-2018
Ultrafiltration (UF) is a filtrate selection method with a wide range of biomedical and clinical applications, including detoxification of blood in hemodialysis and peritoneal dialysis. New is, however, the use of UF as a convenient in vivo sampling method that, for example, has been used in diabetics. Ultrafiltration avoids complicated and time-consuming recovery calculations that are necessary when using in vivo microdialysis, as recoveries of low molecular weight molecules are near 100%. The subcutaneously or intravenously placed UF probes have been studied for off-line sample analysis and for continuous on-line monitoring, in a wide variety of species, including dogs, rats, pigs and humans. This review discusses the potential of in vivo UF as a continuous tissue sampling technique in clinical research areas, and in several major biomedical applications including glucose and lactate monitoring and drug kinetic studies.  相似文献   

7.
1. Although microdialysis is a widely used approach for in vivo monitoring extracellular neurotransmitter concentrations, it has been previously limited in many cases by its poor temporal resolution. It is clear that when 10–30-min sampling is performed, short-lasting changes in extracellular neurotransmitter concentrations can be overlooked. Such a low sampling rate is necessary when combining microdialysis with the conventional analytical methods like high performance liquid chromatography.2. Since capillary electrophoresis coupled to laser-induced fluorescence detection (CE-LIFD) allows the detection of attomoles of neurotransmitters, the temporal resolution of microdialysis may be significantly improved: high sampling rates, in the range of 5 s to 1 min, have been already reported by our group and others using CE-LIFD for simultaneously analyzing catecholamines and amino acids in microdialysates.3. The power of combining microdialyis and CE-LIFD is shown, using examples of physiological and pharmacological studies dealing with the dynamics of in vivo efflux processes and/or interactions between neurotransmitters.  相似文献   

8.
Experimental and theoretical microdialysis studies of in situ metabolism   总被引:2,自引:0,他引:2  
Microdialysis sampling was performed to monitor localized metabolism in vivo and in vitro. A mathematical model that accounts for analyte mass transport during microdialysis sampling was used to predict metabolite concentrations in the microdialysis probe during localized metabolism experiments. The model predicts that metabolite concentrations obtained in the microdialysis probe are a function of different experimental parameters including membrane length, perfusion fluid flow rate, and sample diffusive and kinetic properties. Different microdialysis experimental parameters including membrane length and perfusion fluid flow rate were varied to affect substrate extraction efficiency (E(d)), or loss to the sample matrix, in vivo and in vitro. Local hepatic metabolism was studied in vivo in male Sprague-Dawley rats by infusing acetaminophen through the microdialysis probe. Acetaminophen sulfate concentrations increased linearly with respect to acetaminophen E(d) in contrast to modeling predictions. Xanthine oxidase was used as an in vitro model of localized metabolism. In vitro experimental results partially matched modeling predictions for 10-mm probes. These results suggest that monitoring local metabolism using microdialysis sampling is feasible. It is important to consider system parameters such as dialysis flow rate, membrane length, and sample properties because these factors will affect analyte concentrations obtained during local metabolism experiments.  相似文献   

9.
This study evaluated the suitability of some disinfection and sterilization methods for use with microdialysis probes. Disinfection or sterilization should minimize the tissue inflammatory reaction and improve the long-term health of rats on study and ensure the quality of data obtained by microdialysis sampling. Furthermore, the treatment should not negatively impact probe integrity or sampling performance. The techniques chosen for evaluation included two disinfection methods (70% ethanol and a commercial contact lens solution) and two sterilization methods (hydrogen peroxide plasma, and e-beam radiation). Linear microdialysis probes treated by these processes were compared to untreated probes removed from the manufacturer's packaging as if sterile (the control group). The probes were aseptically implanted in the livers of rats and monitored for 72 hours. The parameters chosen to evaluate probe performance were relative sample mass recovery and the relative in vivo extraction efficiency of the probe for caffeine. Post mortem bacterial counts and histopathology examination of liver tissue were also conducted. The probes remained intact and functional for the entire study period. The methods tested did not acutely alter the probes although hydrogen peroxide plasma and contact lens solution groups showed reduced extraction efficiencies. Minimal tissue damage was observed surrounding the probes and acute inflammatory reaction was mild to moderate. Low numbers of bacterial colonies from the implantation sites indicates that the health of animals in this study was not impaired. This was also true for the control group (untreated probe).  相似文献   

10.
In vivo sampling of interstitial fluid by using microdialysis fibers has become a standard and accepted procedure. This sampling method is generally coupled to offline analysis of consecutive dialysate samples by high-performance liquid chromatography or capillary electrophoresis, but this combination is not the best approach for some applications, especially those which require high temporal resolution and rapid data collection. The purpose of this review is to provide information on enzyme-based online assays, i.e., continuous analysis of the dialysate as it emerges from the outlet of the sampling device. We have focused on methods developed specifically for the analysis of solutions perfused at a very slow flow rate, i.e., a feature of microdialysis and ultrafiltration techniques. These methods include flow enzyme-fluorescence assays, flow enzyme-amperometric assays, and sequential enzyme-amperometric detection. Each type of assay is discussed in terms of principle, applications, advantages, and limitations. We also comment on implantable biosensors, an obvious next step forward for in vivo monitoring of molecules in neuroscience.  相似文献   

11.
Microdialysis is a widely used experimental technique, which offers the opportunity to measure drug and metabolite concentrations in the interstitial space fluid in animals and humans. However, microdialysis probes need to be calibrated in vivo to obtain a recovery factor, which describes the relative drug transfer across the membrane. Recently, novel time-saving calibration techniques, based on the use of reference compounds, have been developed. In particular, the use of endogenous urea levels has been advocated. In the present study we set out to validate the use of the urea reference technique for microdialysis probe calibration in healthy volunteers, employing glucose and paracetamol as model analytes. Urea calibration was compared with the results of two standard calibration techniques, i.e. the no net flux technique and the retrodialysis technique. For glucose, recovery values, calculated by the urea reference technique differed significantly from those values, which were assessed by the no net flux technique (p < 0.05), whereas for paracetamol recovery values did not differ significantly, albeit a high intramethod variability was observed (CV=66%). As a conclusion, we could not confirm the hypothesis that recovery values calculated by the urea reference technique provide equivalent results compared with standard calibration techniques.  相似文献   

12.
Abstract: Numerical modeling was used as a means to examine the relationship between the outcome of in vivo voltammetry and microdialysis experiments and dopamine concentrations in the extracellular fluid of rat striatum. In the case of microdialysis, quantitative interpretation of results demands knowledge of the in vivo values for the extraction and recovery ratios of the probes toward dopamine. Equality of the extraction and recovery ratios is a necessary condition for the direct application of the no-net-flux method as a quantitative technique. Recent results have suggested that the extraction and recovery ratios are not equal, and this interpretation is now supported by theory. A new relationship between extraction and recovery is proposed.  相似文献   

13.
Our newly developed method using a dialysis electrode has made it possible to perform real time monitoring of extracellular glutamate concentration ([Glu]e) utilizing the oxygen-independent reaction with glutamate oxidase and ferrocene. In this study, we therefore, investigated [Glu]e changes during brain ischemia using both the conventional microdialysis method and the dialysis electrode method. A comparison between our newly developed dialysis electrode and conventional microdialysis methods provided the following results. When the conventional microdialysis method was employed: (1) the elevation of [Glu]e during complete global ischemia was delayed; and (2) the elevation of concentration and reuptake of glutamate were delayed during 10-min transient ischemia, and the elevation of [Glu]e reached a maximum later using conventional microdialysis than using our dialysis electrode. (3) The biphasic [Glu]e elevation of glutamate concentration detected using the dialysis electrode method was not observed using the conventional microdialysis method. It was additionally investigated why the conventional microdialysis method provides inferior time resolution. In this study, we also demonstrated with the chromatographic SMART procedure coupled to UV detection that biogenic substances, i.e. low molecular weight proteins and peptides, are released during ischemic injury, and they may cause a delay in the time resolution in the microdialysis method.  相似文献   

14.
Microdialysis sampling has become an important method for the continuous monitoring from an in vivo environment. This technique has been used to monitor many endogenous molecules, such as neurotransmitters, as well as exogenous species such as drug substances. Microdialysis samples have traditionally been analyzed by liquid chromatographic (LC) methods to gain resolution and quantification of the molecules of interest. However, LC separations have a relatively large injection volume requirement which, as a consequence, increases microdialysis sampling times. Capillary electrophoresis (CE), with its very small sample volume requirements and high resolving power, has therefore gained popularity as an alternative to LC. Reviewed here are many of the technologies currently available for CE and examples of how this technique has been effectively applied to the analysis of microdialysis samples.  相似文献   

15.
Microdialysis is a relatively new in vivo sampling technique, which allows repeated collecting of interstitial fluid and infusion of effector molecules into the tissue without influencing whole body function. The possibility of using microdialysis catheter with a large-pore size dialysis membrane (100 kDa) to measure concentrations of the adipocyte-derived peptide hormone leptin in interstitial fluid of adipose tissue was explored. Krebs–Henseleit buffer with 40 g/l dextran-70 was used to prevent perfusion fluid loss across the dialysis membrane. The relative recovery of leptin in vitro was determined using CMA/65 microdialysis catheter (100 kDa cut-off, membrane length 30 mm; CMA, Stockholm, Sweden) and four perfusion rates were tested (0.5, 1.0, 2.0, 5.0 μl/min). Furthermore, the microdialysis catheter CMA/65 was inserted into subcutaneous abdominal adipose tissue of 11 healthy human subjects and leptin concentrations in the interstitial fluid of adipose tissue in vivo were measured. The present findings are the first documentation on the use of microdialysis to study local leptin concentrations in the interstitial fluid of adipose tissue.  相似文献   

16.
An enhanced microdialysis method for neuropeptides is described and some preliminary results of this novel approach are presented. The enhancement is achieved by adding a vehicle (solid support) to the perfusion fluid in order to increase the diffusion coefficient across the membrane and efficiently transport the analytes towards the detector. The microdialysis samples are desalted and then analyzed on an electrospray ionization orthogonal time-of-flight mass spectrometer. The preliminary results show major increase in signal when comparing this new approach of microdialysis with ordinary microdialysis.  相似文献   

17.
Pediatric diffuse intrinsic pontine gliomas are aggressive brainstem tumors that fail to respond to treatment. We hypothesize that the protective features of the pons may hinder chemotherapeutic agents from entering pontine tissue compared with cortical brain tissue. To test this hypothesis, we developed a unique nonhuman primate model using microdialysis, a continuous in vivo extracellular sampling technique, to compare drug exposure concurrently in pontine tissue, cortical tissue, CSF, and plasma after intravenous administration of chemotherapeutic agents. The surgical coordinates and approach for microdialysis cannula–probe placement were determined in 5 adult male rhesus monkeys (Macaca mulatta) by using MRI. Microdialysis cannulas–probes were implanted stereotactically in the brain, retrodialysis was performed to measure relative recovery, and a 1-h intravenous infusion of temozolomide was administered. Continuous microdialysis samples were collected from the pons and cortex over 4 h with concurrent serial plasma and CSF samples. Postsurgical verification of microdialysis cannula–probe placement was obtained via MRI in 3 macaques and by gross pathology in all 5 animals. The MRI-determined coordinates and surgical methodologies resulted in accurate microdialysis probe placement in the pons and cortex in 4 of the 5 macaques. Histologic examination from these 4 animals revealed negligible tissue damage to the pontine and cortical tissue from microdialysis. One macaque was maintained for 8 wk and had no deficits attributed to the procedure. This animal model allows for the determination of differences in CNS penetration of chemotherapeutic agents in the pons, cortex, and CSF after systemic drug administration.Abbreviations: DIPG, diffuse intrinsic pontine glioma; ECF, extracellular fluidPediatric diffuse intrinsic pontine gliomas (DIPG) are aggressive tumors that cannot be surgically resected due to their location, and are resistant to chemotherapeutic and radiation therapies. As a result, children with DIPG have a dismal prognosis with median survival less than one year from diagnosis. One hypothesis for the poor efficacy of treatment is that innate CNS protective features, such as the blood–brain barrier and the blood–CSF barrier, shield the brainstem to a higher degree given its critical functions, and isolate pontine gliomas from treatment. To test this hypothesis, we developed a nonhuman primate model in rhesus monkeys to evaluate pontine tissue pharmacokinetics by using microdialysis, a continuous in vivo extracellular sampling technique based on diffusion. Microdialysis is the ‘gold standard’ for in vivo sampling methodologies in the CNS, enabling the collection of extracellular tissue fluid via passive diffusion by using a semipermeable membrane probe.A nonhuman primate model demonstrating the feasibility of microdialysis sampling from cortical brain tissue with concurrent pharmacokinetic sampling during chemotherapeutic drug administration has previously been established,3-5,7 but there are no current animal models that measure drug penetration into the pons. The location of the pons deep within the brain, as well as the vital brainstem functions associated with the pons, present additional obstacles to accurate microdialysis probe placement and sample collection. The objectives of the current study were to develop imaging and surgical procedures for the accurate placement of a microdialysis probe within the pons of rhesus monkeys for sample collection, to establish a method to perform microdialysis simultaneously in multiple CNS regions, and to develop a mechanism to perform repeated microdialysis in the same areas with a single invasive surgical procedure. This model allows for the pharmacokinetic comparison of drug penetration into pontine tissue, in conjunction with cortical tissue, plasma, and CSF, after intravenous administration.  相似文献   

18.
The purpose of this study was to examine and validate the use of microdialysis for sampling and pharmacologically manipulating extracellular amino acids in the brain. Repeated use of microdialysis probes in acute intracerebral experiments did not significantly alter the relative recovery in vitro for the amino acids quantitated (GABA, aspartate, glutamate, glycine, taurine, and alanine). Regional differences in basal levels of some of the amino acids were detected in dialysates collected from the dorsomedial hypothalamus, striatum, and frontal cortex. The percent in vitro recoveries for the amino acids from the probes used in the three regions were not significantly different suggesting that the regional differences in basal levels of amino acids were functionally derived and not a consequence of variations in probe recovery. Perfusion with nipecotic acid, an inhibitor of GABA uptake, resulted in selective elevations in extracellular GABA in the three regions studied. Conversely, perfusion with high-potassium, a depolarizing agent, resulted in significant elevations in not only extracellular GABA but also aspartate, glutamate, and taurine. Thus, microdialysis is a method which can be employed to assess and to pharmacologically manipulate extracellular amino acids in the rat brain.  相似文献   

19.
The application of in vivo microdialysis to the study of acetylcholine (ACh) release has contributed greatly to our understanding of cholinergic brain systems. This article reviews standard experimental procedures for dialysis probe selection and implantation, perfusion parameters, neurochemical detection, and data analysis as they relate to microdialysis assessments of cholinergic function. Particular attention is focused on the unique methodological considerations that arise when in vivo microdialysis is dedicated expressly to the recovery and measurement of ACh as opposed to other neurotransmitters. Limitations of the microdialysis technique are discussed, as well as methodological adaptations that may prove useful in overcoming these limitations. This is followed by an overview of recent studies in which the application of in vivo microdialysis has been used to characterize the basic pharmacology and physiology of cholinergic neurons. Finally, the usefulness of the microdialysis approach for testing hypotheses regarding the cholinergic systems' involvement in cognitive processes is examined. It can be concluded that, in addition to being a versatile and practical method for studying the neurochemistry of cholinergic brain systems, in vivo microdialysis represents a valuable tool in our efforts to better comprehend ACh's underlying role in a variety of behavioral processes.  相似文献   

20.
The relatively new technique of microdialysis provides new possibilities for investigating in vivo the functioning of the sympathetic nervous system. The small sample volumes obtained, however, are a great challenge for analytical chemists. We report here a HPLC method for measuring in one run both natural and synthetic catecholamines [dopamine, (nor)epinephrine, -methylnorepinephrine, isoproterenol and epinine] and the intraneuronal metabolite 3,4-dihydroxyphenylglycol in small microdialysis samples after derivatization with the fluorogenic agent 1,2-diphenylethylenediamine. No prior clean-up step is necessary. N-Ethylmaleimide is necessary for preventing an inhibitory action on derivatization occurring in in vivo microdialysis samples. The method can handle large numbers of samples, is sensitive (on-column detection limits 30 to 200 fg) and reproducible (RSD 1 to 7%). Recovery characteristics of the commercial microdialysis probe used (CMA/20) were extensively investigated both in vitro and in vivo at various perfusion rates; for practical purposes a rate of 2 μl/min and sampling at 10-min intervals was found to be workable and to give good and reproducible recoveries (50 to 70%).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号