首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
The first HPLC-fluorescence method for the determination of atomoxetine in human plasma was developed and validated. Atomoxetine was derivatized with 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride (DIB-Cl) under mild conditions, and separated isocratically on a C18 column using a HPLC system with fluorescence detection (lambdaex: 318 nm, lambdaem: 448 nm). A linear calibration curve was obtained over the concentration range 1-1000 ng/mL (r=0.999). The limit of detection (S/N=3) was 0.3 ng/mL. The relative standard deviations of intra-day and inter-day variations were < or =8.30% and 7.47%, respectively. This method is rapid, sensitive, and suitable for both basic and clinical studies of atomoxetine.  相似文献   

3.
An HPLC- fluorescence method to quantitate total 7-ethyl-10-hydroxy-camptothecin (SN-38) in beagle dog plasma spiked with liposome based formulation of SN-38 (LE-SN38) and using camptothecin (CPT) as the internal standard (I.S.) was developed and validated to support pharmacokinetics/toxicokinetics studies. Sample preparation was done by protein precipitation using acetonitrile with 0.5% acetic acid. The supernatant was evaporated, and reconstituted in acetonitrile-20 mM ammonium acetate, pH 3.5 (20:80, v/v). When injected onto a Zorbax SB-C(18) HPLC column SN-38 as well as I.S. were detected by fluorescence using an excitation at 368 nm and emission at 515 nm. The SN-38 concentrations in samples were calculated from a standard curve of peak area ratios of SN-38 to the I.S. using weighted linear regression. The sensitivity limit for SN-38 was 1.00 ng/ml in beagle dog plasma with a precision (expressed as relative standard deviation) of 12.4% and an accuracy (expressed as analytical recovery) of 104%. The assay was linear within the standard curve range of 1-750 ng/ml. Acceptable precision and accuracy were also obtained for concentrations over the balance of the standard curve range from between-run and within-run calculations.  相似文献   

4.
A sensitive method has been developed and validated for the determination of artesunate and its active metabolite dihydroartemisinin (DHA) in human plasma using artemisinin as an internal standard. Solid phase extraction (SPE) using Oasis HLB extraction cartridges was used for sample preparation and analysis was performed on a Shimadzu LCMS-2010 in single ion monitoring positive mode using atmospheric pressure chemical ionization (APCI) as an interface. Positive ions were measured using extracted ion chromatogram mode. The extracted ion for artesunate, alpha- and beta-DHA was m/z 221 and for artemisinin was m/z 283. Chromatography was carried out using a Synergi Max-RP, 4 mu, 75 mm x 4.6 mm column using glacial acetic acid 0.1%, acetonitrile and methanol mixture (38:46.5:15.5) as a mobile phase delivered at a flow rate of 0.5 mL/min. The retention times of artesunate, alpha- and beta-DHA and artemisinin were 17.4, 11.8, 18.7 and 13.4 min, respectively, with a total run time of 21 min. The assay was linear over the range 1-3000 ng/mL for artesunate and DHA. The analysis of quality control samples for artesunate 50, 300, 1300 and 2600 ng/mL demonstrated excellent precision with relative standard deviation of 14.3, 11.3, 7.5 and 12.1%, respectively (n=5). Recoveries at concentration of 50, 300, 1300 and 2600 ng/mL were 75, 94.5, 74.3 and 75.5%, respectively; similar results were obtained for precision and recovery of DHA. This liquid chromatography-mass spectroscopy (LC-MS) method for the determination of artesunate and DHA in human plasma has superior specification for sensitivity, sample throughput and robustness than previous methods and can reliably quantitate concentrations of both (artesunate and DHA) compounds as low as 1 ng/mL.  相似文献   

5.
A number of analytical methods have been established to quantify methylphenidate (MPH). However, to date no HPLC methods are applicable to human pharmacokinetic studies without the use of mass spectrometry (MS) detection. We developed a sensitive and reliable HPLC-fluorescence method for the determination of MPH in human plasma using 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride (DIB-Cl) as the derivatizing agent. An established GC-MS method was adopted in this study as a comparator assay. MPH was derivatized using DIB-Cl, and separated isocratically on a C18 column using a HPLC system with fluorescence detection (lambda(ex)=330 nm, lambda(em)=460 nm). The lower limit of quantification was found to be 1 ng/mL. A linear calibration curve was obtained over the concentrations ranging from 1 ng/mL to 80 ng/mL (r=0.998). The relative standard deviations of intra-day and inter-day variations were 相似文献   

6.
BACKGROUND: CD14, the major lipopolysaccharide (LPS)-binding protein of myeloid cells, is found as a soluble molecule in human serum. Recent data describe the presence of elevated soluble CD14 (sCD14) concentration in various disorders, confirming disease activity. A novel, easy, and rapid flow cytometric assay was developed to measure sCD14 levels in serum. METHODS: The assay is based on the competition between membrane-expressed CD14 of isolated monocytes from healthy volunteers and sCD14 in the sample sera for binding to anti-CD14 monoclonal antibodies (mAb; 26ic or 60bca). The amount of cell-associated mAb is determined with a fluorescein isothiocyanate (FITC)-labeled anti-mouse conjugate and flow cytometry. The fluorescence signal is inversely proportional with the amount of serum sCD14. Using dilutions of a standard serum, the concentration of sCD14 in the samples is calculated and compared with results obtained by a commercial sCD14 enzyme-linked immunosorbent assay (ELISA). RESULTS: After optimization, the assay showed log-log linearity of 122.1-984.7 ng/ml sCD14 using mAb 26ic and 29.5-246.2 ng/ml sCD14 using mAb 60bca. It revealed similar results as the ELISA (mAb 26ic: r = 0.88, mAb 60bca: r = 0.92) and provided significantly elevated sCD14 levels in systemic lupus erythematosus patients compared with controls (26ic: 2,213 versus 1,676 ng/ml, P < 0.002; 60bca: 2,625 versus 1,907 ng/ml, P < 0.0002). Receiver operating characteristic curve analysis suggested a reasonable diagnostic efficacy of sCD14 quantification in this autoimmune disease. CONCLUSIONS: The method is easy, rapid, sensitive, and can be used in the follow-up of patients suffering from sepsis or chronic inflammatory disorders.  相似文献   

7.
A reliable method has been developed for the determination of pyronaridine in human urine using amodiaquine as an internal standard. Liquid-liquid extraction was used for sample preparation. Analysis was performed on a Shimadzu LCMS-2010 in single ion monitoring positive mode using atmospheric pressure chemical ionization (APCI) as an interface. The extracted ion for pyronaridine was m/z 518.20 and for amodiaquine was m/z 356.10. Chromatography was carried out using a Gemini 5 microm C18 3.0 mmx150 mm column using 2 mM perflurooctanoic acid and acetonitrile mixture as a mobile phase delivered at a flow rate of 0.5 mL/min. The mobile phase was delivered in gradient mode. The retention times of pyronaridine and amodiaquine were 9.1 and 8.1 min respectively, with a total run time of 14 min. The assay was linear over a range of 14.3-1425 ng/mL for pyronaridine (R2>or=0.992, weighted 1/Concentration). The analysis of quality control samples for pyronaridine at 28.5, 285, 684 and 1140 ng/mL demonstrated excellent precision with relative standard deviation of 5.1, 2.3, 3.9 and 9.2%, respectively (n=5). Recoveries at concentrations of 28.5, 285, 684 and 1140 ng/mL were all greater than 85%.This LC-MS method for the determination of pyronaridine in human urine has excellent specifications for sensitivity, reproducibility and accuracy and can reliably quantitate concentrations of pyronaridine in urine as low as 14.3 ng/mL. The method will be used to quantify pyronaridine in human urine for pharmacokinetic and drug safety studies.  相似文献   

8.
A gas chromatography-mass spectrometry (GC-MS) assay for the determination of tramadol in human plasma is presented. The synthesis of an N-ethyl analogue of the drug is described and its use as an internal standard for the quantitative measurement of tramadol in human plasma is described. The method involves extraction at plasma pH and analysis of the underivatized drug by gas chromatography-electron ionization mass spectrometry using m/z 58 and 73 for detection of tramadol and internal standard, respectively. The calibration curve was linear in the range of 5-640 ng/ml plasma (r=0.9999). The method was validated in the abovementioned calibration range. Data on solution stability, long- and short-term stability of tramadol in plasma samples, freeze-thaw-stability, as well as inter- and intra-day precision and accuracy have been evaluated and are presented. The application of the method to the pharmacokinetic profiling of the drug is demonstrated.  相似文献   

9.
目的建立快速、敏感、特异的猴免疫缺陷病毒(SIV)TaqMan探针实时荧光定量PCR检测方法,对SIV病毒核酸进行定量检测。方法RT—PCR扩增SIVmac251保守gag基因序列796bp片段,进行TA克隆,构建标准品质粒pMD—SIVgag。通过对SIV定量外标准品的定量分析,优化反应体系,检测TaqMan探针实时荧光定量PCR方法的灵敏度、特异性和重复性。结果所建立的SIVQPCR检测方法,质粒DNA模板在10’~10。拷贝之间表现较好线性和相关性,标准曲线所得斜率为-3.26,相关系数为0.999。检测灵敏度达到200拷贝,方法重复性测试,检测25份临床样品CV%均小于1%。结论建立的SIVQPCR检测方法特异性、敏感性高,稳定性好,可用于定量测定猴免疫缺陷病毒(SIV)核酸拷贝量。  相似文献   

10.
Betamethasone is a synthetic corticosteroid designed to exert a marked glucocorticoid activity. As the free alcohol, betamethasone finds widespread clinical applications related to its anti-inflammatory and immunosuppressant activity. In the present study, a fast, sensitive, robust method was developed for the determination and quantification of betamethasone in human plasma by liquid chromatography coupled with tandem mass spectrometry, using photospray ionization in negative mode. Betamethasone was extracted from 0.5 ml human plasma by liquid-liquid extraction (LLE) using chloramphenicol as internal standard. The method has a chromatographic run of 2.5 min using a C(18) analytical column (100 mm x 2.1 mm i.d.) and the linear calibration curve over the range was linear from 0.05 to 50 ng ml(-1) (r(2)>0.993). The between-run precision, based on the relative standard deviation replicate quality controls was 94.1% (0.15 ng ml(-1)), 90.7% (4.0 ng ml(-1)) and 97.2% (40 ng ml(-1)). The between-run accuracy for the above-mentioned concentrations was 11.9, 9.0 and 9.8%, respectively. The method herein described was employed in a bioequivalence study of two formulations of dexchlorpheniramine/betamethasone 2 mg/0.25 mg tablets.  相似文献   

11.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry with delayed ion extraction (DE MALDI-TOF MS) was applied for the first time for the quantitation of sulfatide content in serum at the picomole level. The total lipids extracted by n-hexane:isopropanol (3:2, v/v) from 100 microliter of serum were saponified to convert sulfatide to its lyso form, and then the lysosulfatide was directly determined using DE MALDI-TOF MS in the presence of other degraded lipids. Hydrogenated N-acetyl lysosulfatide was used as an internal standard. The relative peak height of sulfatide was calculated and plotted versus its contents. This plot showed linearity between 2 pmol and 1 nmol of sulfatide (regression coefficient r > 0.95). Sulfatide contents of normal human sera and rabbit serum were quantitated by this method. The results corresponded well to the reported data determined by gas-liquid chromatography. This new approach was found to be sensitive, convenient, and reliable. It is expected to be applied to quantitate sulfatide from other small amounts of body fluids or tissues and to clinical examination. It is also expected to be applicable to quantitate other glycosphingolipids.  相似文献   

12.
A stable isotope dilution gas chromatography-mass spectrometry (GC-MS) assay for the trace level determination of estriol in human plasma is described. Negative ion chemical ionization (NICI) MS is used for highly specific detection. The method involves derivatization of the phenolic hydroxyl to the pentafluorobenzyl ether derivative and subsequent reaction of the remaining hydroxyls with heptafluorobutyric anhydride. This derivative allows detection of the strikingly abundant phenolate ion under NICI conditions. [2,4,17beta]-2H(3)-labeled estriol was used as an internal standard. For high-level measurements (>313 ng/l) plasma was directly derivatized by extractive alkylation followed by heptafluorobutylation prior to analysis. A rapid and simple sample work up procedure was elaborated for trace level determinations (>5 ng/l plasma) using solid-phase extraction on C(18) with an absolute recovery of 92.9%. For low-level measurements, the calibration curve was linear in the range of 5 to 625 ng/l (r=0.99993). Inter-assay analytical precisions (RSDs) were 1.29, 2.30 and 2.89% at 39, 156 and 650 ng/l plasma, respectively. For high-level measurements, calibration curve linearity was observed in the range of 0.313 to 20 microg/l (r=0.99998). Inter-assay analytical precisions (RSDs) were 5.17, 1.92, 2.57 and 2.74% at 0.313, 0.625, 2.5 and 10 microg/l plasma, respectively. Postmenopausal plasma was used for spiked plasma samples. Sensitivity and specificity of the presented method allows adequate determination of estriol in human plasma samples.  相似文献   

13.
This paper describes a GC–MS method for the analysis of the carboxylic acid metabolite (SR26334, II) of methyl (+)-(S)--(o-chlorophenyl)-6,7-dihydrothieno[3,2-c]pyridine-5(4H)-acetate hydrogensulfate (clopidogrel, SR 25990, I) in plasma and serum. The analytical procedure involves a robotic liquid–liquid extraction with diethyl ether followed by a solid–liquid extraction on C18 cartridges. The derivatization process was performed using n-ethyl diisopropylethylamine and -bromo-2,3,4,5,6-pentafluoro toluene. A structural analogue (III) of II, was used as internal standard. The 1/X2; weighted calibration curve obtained in the range 5–250 ng/ml was well described by a quadratic equation. The extraction efficiency was better than 48% over the range studied; for the internal standard it averaged 51% at 50 ng/ml. Precision ranged from 3.6 to 15.8%, and accuracy was between 92 and 114%. Dilution has no influence on the performance of the method which could then be used to quantitate plasma samples containing up to 25 000 ng/ml. The limit of quantification was 5 ng/ml. The method validation results indicate that the performance characteristics of the method fulfilled the requirements for assay methods for use in pharmacokinetic studies.  相似文献   

14.
N-Substituted 3alpha-[bis(4'-fluorophenyl)methoxy] tropanes represent a series of novel potential cocaine abuse therapeutics. AHN-1055, a member of this series, has been assessed to be the most suitable analog for pharmacokinetic studies. A sensitive and specific high-performance liquid chromatography method was developed to quantitate AHN-1055 in rat plasma and brain tissue. Reversed-phase chromatography with ultraviolet detection (lambda=220 nm) was utilized to quantitate the eluate. Plasma or brain tissue samples were prepared by liquid-liquid extraction using hexane, followed by evaporation, reconstitution in mobile phase, and injection onto an ABZ+plus column. AHN-1055 and oxprenolol (internal standard) eluted at approximately 9.9 and 5.01 min, respectively, without any interfering peaks. The calibration curves were found to be linear in the range of 25-10000 ng/ml for plasma and 50-5000 ng/g for brain (r2> or =0.999). The intra- and inter-day variabilities were < or =10% whereas the intra- and inter-day errors were < or =8.5%. Plasma and brain recoveries of AHN-1055 were 95 and 79%, respectively. Stability studies showed plasma quality control samples to be stable through at least three freeze-thaw cycles (error<3.5%), for at least 24 h when subjected to room temperature (error<3%) and for at least 30 h after loading the processed samples onto the autosampler (error<3%). AHN-1055 stock solution was found to be stable for at least 4 months when stored at 4 degrees C (error<6%). The validated method accurately quantified AHN-1055 in plasma and brain samples collected from a pharmacokinetic study consisting of an intravenous bolus in the tail vein of adult male Sprague-Dawley rats.  相似文献   

15.
A sensitive method was developed and validated for the measurement of 17-(allylamino)-17-demethoxygeldanamycin (17AAG) and its active metabolite 17-amino-17-demethoxygeldanamycin (17AG) in human plasma using 17-(dimethylaminoethylamino)-17-demethoxygeldanamycin (17DMAG) as an internal standard. After the addition of internal standard, 200 microL of plasma was extracted using ice cold acetonitrile followed by analysis on a Thermo Finnigan triple-quadruple mass spectrometer coupled to an Agilent 1100 HPLC system. Chromatography was carried out on a 50 mm x 2.1 mm Agilent Zorbax SB-phenyl 5 microm column coupled to a 3mm Varian metaguard diphenyl pre-column using glacial acetic acid 0.1% and a gradient of acetonitrile and water at a flow rate of 500 microL/min. Atmospheric pressure chemical ionization and detection of 17AAG, 17AG and 17DMAG were accomplished using selected reaction monitoring of m/z 584.3>541.3, 544.2>501.2, and 615.3>572.3, respectively in negative ion mode. Retention times for 17AAG, 17AG, and 17DMAG were 4.1, 3.5, and 2.9 min, respectively, with a total run time of 7 min. The assay was linear over the range 0.5-3000 ng/mL for 17AAG and 17AG. Replicate sample analysis indicated within- and between-run accuracy and precision within 15%. The recovery of 17AAG and 17AG from 200 microL of plasma containing 1, 25, 300, and 2500 ng/mL was 93% or greater. This high-performance liquid chromatographic tandem mass spectroscopy (HPLC/MS/MS) method is superior to previous methods. It is the first analytical method reported to date for the quantitation of both 17AAG and its metabolite 17AG and can reliably quantitate concentrations of both compounds as low as 0.5 ng/mL.  相似文献   

16.
A rapid, sensitive, robust and specific method was developed for the determination and quantitation of felodipine, in human blood plasma by liquid chromatography coupled with tandem mass spectrometry using nimodipine as internal standard. Felodipine was extracted from 0.5 mL human plasma by use of a liquid/liquid procedure using diethyl ether/hexane (80/20, v/v) as eluent. The method included a chromatographic run of 5 min using a C(18) analytical column (100 mm x 4.6 mm i.d.) and the calibration curve was linear over the range from 0.02 to 10 ng mL(-1) (r(2) > 0.994). The between-run precision, determined as relative standard deviation of replicate quality controls, was 5.7% (0.06 ng mL(-1)), 7.1% (0.6 ng mL(-1)) and 6.8% (7.5 ng mL(-1)). The between-run accuracy was +/- 0.0, 2.1 and 3.1% for the above-mentioned concentrations, respectively.  相似文献   

17.
The microenvironment of the CNS has been considered to tonically inhibit glial activities. It has been shown that glia become activated where neuronal death occurs in the aging brain. We have previously demonstrated that neurons tonically inhibit glial activities including their responses to the bacterial endotoxin lipopolysaccharide (LPS). It is not clear whether activation of glia, especially microglia in the aging brain, is the consequence of disinhibition due to neuronal death. This study was designed to determine if glia regain their responsiveness to LPS once the neurons have died in aged cultures. When cultured alone, glia from postnatal day one rat mesencephalons stimulated with LPS (0.1-1000 ng/mL) produced both nitric oxide (NO) and tumor necrosis factor alpha (TNFalpha), yielding a sigmoid and a bell-shaped curve, respectively. When neuron-containing cultures were prepared from embryonic day 14/15 mesencephalons, the shape of the dose-response curve for NO was monotonic and the bell-shaped curve for TNFalpha production was shifted to the right. After 1 month of culture under conditions where neurons die, the production curves for NO and TNFalpha in LPS-stimulated glia shifted back to the left compared to mixed neuron-glia cultures. Immunostaining of rat microglia for the marker CR3 (the receptor for complement component C3) demonstrated that high concentrations of LPS (1 microg/mL) reduced the number of microglia in mixed-glial cultures. In contrast, reduction of CR3 immunostaining was not observed in LPS-stimulated mixed neuron-glia cultures. Taken together, the results demonstrate that disinhibition of the glial response to LPS occurs after neurons die in aged cultures. Once neurons have died, the responsiveness of glia to LPS is restored. Neurons prevented injury to microglia by reducing their responsiveness to LPS. This study broadens our understanding of the ways in which the CNS microenvironment affects cerebral inflammation.  相似文献   

18.
A highly sensitive high-performance liquid chromatographic-tandem mass spectrometric method (HPLC-MS-MS) has been developed to quantitate clemastine in human plasma for the purpose of pharmacokinetic studies. Sample preparation was carried out by liquid-liquid extraction using deuterated clemastine as an internal standard. Chromatographic separation used a C18 reversed phase polymer column giving an extremely fast total run time of 2 min. The method was validated and used for the bioequivalence study of clemastine tablets in healthy male volunteers (n=28). The lower limit of detection proved to be 0.01 ng/ml for clemastine.  相似文献   

19.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.  相似文献   

20.
A rapid and simple method for quantitation of metformin (MET) in human plasma by HPLC-MS/MS was developed and validated. The sample preparation consists of plasma deproteinization using acetonitrile. The mobile phase consisted of water-acetonitrile and formic acid (55/45/0.048, v/v/%) and the run time was 3 min. A pursuit C(18) (100 mm x 2.0 mm i.d., 3 microm) column connected to a guard column MS-pursuit (0.20 mm x 0.20 mm i.d., 5 microm) was used. The range of the calibration curve was from 20 to 5000 ng/mL, the limit of quantitation being 20 ng/mL. The detection was performed on a mass spectrometer (ESI+), using metoprolol as internal standard. The calibration curves have r(2) values of 0.995 (CV=0.24%, n=10). The accuracy and precision were between 90.74 and 106.7% and coefficients of variations (CV) of 1.10 and 4.35%, respectively. The method was applied to determine the pharmacokinetic parameters: C(max) (1667.25 ng/mL) and T(max) (3.89 h).  相似文献   