首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A wide variety of sulfur metabolites play important roles in plant functions. We have developed a precise and sensitive method for the simultaneous measurement of several sulfur metabolites based on liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) and 34S metabolic labeling of sulfur-containing metabolites in Arabidopsis thaliana seedlings. However, some sulfur metabolites were unstable during the extraction procedure. Our proposed method does not allow for the detection of the important sulfur metabolite homocysteine because of its instability during sample extraction. Stable isotope-labeled sulfur metabolites of A. thaliana shoot were extracted and utilized as internal standards for quantification of sulfur metabolites with LC–MS/MS using S-adenosylmethionine (SAM), S-adenosylhomocysteine (SAH), methionine (Met), glutathione (GSH), and glutathione disulfide (GSSG) as example metabolites. These metabolites were detected using electrospray ionization in positive mode. Standard curves were linear (r2 > 0.99) over a range of concentrations (SAM 0.01–2.0 μM, SAH 0.002–0.10 μM, Met 0.05–4.0 μM, GSH 0.17–20.0 μM, GSSG 0.07–20.0 μM), with limits of detection for SAM, SAH, Met, GSH, and GSSG of 0.83, 0.67, 10, 0.56, and 1.1 nM, respectively; and the within-run and between-run coefficients of variation based on quality control samples were less than 8%.  相似文献   

2.
Amphetamines are a group of sympathomimetic drugs that exhibit strong central nervous system stimulant effects. d-Amphetamine ((+)-alpha-methylphenetylamine) is the parent drug in this class to which all others are structurally related. In drug discovery, d-amphetamine is extensively used either for the exploration of novel mechanisms involving the catecholaminergic system, or for the validation of new behavioural animal models. Due to this extensive use of d-amphetamine in drug research and its interest in toxicologic–forensic investigation, a specific and high-throughput method, with minimal sample preparation, is necessary for routine analysis of d-amphetamine in biological samples. We propose here a sensitive, specific and high-throughput bioanalytical method for the quantitative determination of d-amphetamine in rat blood using MS3 scan mode on a hybrid triple quadrupole-linear ion trap mass spectrometer (LC–MS/MS/MS). Blood samples, following dilution with water, were prepared by fully automated protein precipitation with acetonitrile containing an internal standard. The chromatographic separation was achieved on a Waters XTerra C18 column (2.1 mm × 30 mm, 3.5 μm) using gradient elution at a flow rate of 1.0 mL/min over a 2 min run time. An Applied Biosystems API4000 QTRAP™ mass spectrometer equipped with turbo ion-spray ionization source was operated simultaneously in MS3 scan mode for the d-amphetamine and in multiple reaction monitoring (MRM) for the internal standard. The MS/MS/MS ion transition monitored was m/z 136.1 → 119.1 → 91.1 for the quantitation of d-amphetamine and for the internal standard (rolipram) the MS/MS ion transition monitored was m/z 276.1 → 208.2. The linear dynamic range was established over the concentration range 0.5–1000 ng/mL (r2 = 0.9991). The method was rugged and sensitive with a lower limit of quantification (LLOQ) of 0.5 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. This method was successfully applied to evaluate the pharmacokinetics of d-amphetamine in rat. On a more general extent, this work demonstrated that the selectivity of the fragmentation pathway (MS3) can be used as alternative approach to significantly improve detection capability in complex situation (e.g., small molecules in complex matrices) rather than increasing time for sample preparation and chromatographic separation.  相似文献   

3.
Bacterial cell wall biosynthesis is the target of several antibiotics and is of interest as a target for new inhibitor development. The cytoplasmic steps of this pathway involve a series of uridine diphosphate (UDP)-linked peptidoglycan intermediates. Quantification of these intermediates is essential for studies of current agents targeting this pathway and for the development of new agents targeting this pathway. In this study, a liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed for quantification of these intermediates in Staphylococcus aureus. To address the problem of poor retention of UDP-linked intermediates on reverse phase media, an ion-pairing (IP) approach using N,N-dimethylhexylamine was developed. MS/MS detection in negative mode was optimized for UDP-GlcNAc, UDP-MurNAc, UDP-MurNAc-l-Ala, UDP-MurNAc-l-Ala-d-Glu, UDP-MurNAc-l-Ala-d-Glu-l-Lys, and UDP-MurNAc-l-Ala-d-Glu-l-Lys-d-Ala-d-Ala. The lower limits of quantification (LLOQs) for these analytes were 1.8, 1.0, 0.8, 2.2, 0.6, and 0.5 pmol, respectively, which correspond to LLOQs of 6, 3, 3, 7, 2, and 2 nmol/g bacteria, respectively. This method was demonstrated for quantification of in vivo levels of these intermediates from S. aureus (0.3 mg dry weight analyzed) treated with fosfomycin, d-boroAla, d-cycloserine, and vancomycin. Metabolite accumulation is consistent with the known targets of these antibiotics and indicates potential regulatory loops within this pathway.  相似文献   

4.
The discrepancy of results for the quantification of androstenedione in human serum between a radioimmunoassay (RIA) method and high performance liquid chromatography tandem-mass spectrometry (LC–MS/MS) was investigated. RIA overestimated concentrations compared to LC–MS/MS on 59 clinical samples (RIA = 1.79 × LC–MS/MS + 0.94). RIA kit and LC–MS/MS calibrants were also determined by both methods. The RIA performed with improved accuracy on the calibrants (RIA = 1.35 × LC–MS/MS − 0.28). Lipid, protein, electrolyte content, and pH of the two sets of calibrants were further investigated. The RIA calibrants contained little lipid material, while the LC–MS/MS calibrant material contained the same levels expected in normal serum/plasma. The pH and sex hormone binding globulin (SHBG) values were different between the RIA calibrants and the LC–MS/MS calibrant material (SHBG, 31 ± 2 and 38 ± 2 nmol/l; pH, 8.27 ± 0.18 and 8.66 ± 0.03, respectively). No correlation was observed between androstenedione RIA and LC–MS/MS discrepancy and lipid or protein. LC–MS/MS sample preparation was tested for the removal of protein-bound material and recovery determined (99–108%). The corresponding RIA results overestimated androstenedione by 52–174% compared to LC–MS/MS. The results here demonstrate that LC–MS/MS is the more accurate method.  相似文献   

5.
Adducts to N-terminal valines in Hb have been shown useful as biomarkers of exposure to electrophilic compounds. Adducts from many compounds have earlier been measured with a modified Edman degradation method using a GC–MS/MS method. A recently developed method, the adduct FIRE procedure™, adopted for analysis by LC–MS/MS, has been applied in this study. With this method a fluorescein isothiocyanate (FITC) reagent is used to measure adducts (R) from electrophiles with a modified Edman procedure. By using LC–MS/MS in product ion scan mode, a new peak was identified and the obtained MS data indicated that this adduct could originate from methyl vinyl ketone (MVK). Incubation of human-, sheep- and bovine blood with MVK increased the signal of the identified peak. By comparing the LC–MS/MS data from the unknown background peak with data obtained from synthesized fluorescein thiohydantoin (FTH) standards of the MVK adduct to valine and d8-valine, the identity of this adduct was confirmed. The MVK adduct was shown present in human blood (∼35 pmol/g globin, n = 3) and only just above LOD in bovine blood, n = 1 (LOD = 2 pmol/g globin). MVK reacts, in similarity with acrylamide, via Michael addition. MVK is known to occur in the environment and has earlier been observed in biological samples, which means that there are possible natural and anthropogenic exposure sources. Analysis of an Hb adduct from MVK in humans has to our knowledge not been described before.  相似文献   

6.
A rapid and sensitive liquid chromatography–electrospray ionization tandem mass spectrometry method (LC–ESI-MS/MS) was developed and validated for the determination of goserelin in rabbit plasma. Various parameters affecting plasma sample preparation, LC separation, and MS/MS detection were investigated, and optimized conditions were identified. Acidified plasma samples were applied to Oasis® HLB solid-phase extraction (SPE) cartridges. Extracted samples were evaporated under a stream of nitrogen and then reconstituted with 100 μL mobile phase A. The separation was achieved on a Capcell-Pak C18 (2.0 mm × 150 mm, 5 μm, AQ type) column with a gradient elution of solvent A (0.05% acetic acid in deionized water/acetonitrile = 85/15; v/v) and solvent B (acetonitrile) at a flow rate of 250 μL/min. The LC–MS/MS system was equipped with an electrospray ion source operating in positive ion mode. Multiple-reaction monitoring (MRM) of the precursor–product ion transitions consisted of m/z 635.7 → m/z 607.5 for goserelin and m/z 424.0 → m/z 292.1 for cephapirin (internal standard). The proposed method was validated by assessing specificity, linearity, limit of quantification (LOQ), intra- and inter-day precision and accuracy, recovery, and stability. Linear calibration curves were obtained in the concentration range of 0.1–20 ng/mL (the correlation coefficients were above 0.99). The LOQ of the method was 0.1 ng/mL. Results obtained from the validation study of goserelin showed good accuracy and precision at concentrations of 0.1, 1, 5, 10, and 20 ng/mL. The validated method was successfully applied to a pharmacokinetic study of goserelin after a single subcutaneous injection of 3.6 mg of goserelin in healthy white rabbits.  相似文献   

7.
A specific polyclonal antibody targeting diethyl phthalate (DEP) with the higher antibody titer at 1:120,000 has been obtained, and an ultrasensitive and high-throughput direct competitive gold nanoparticles improved real-time immuno-PCR (GNP–rt–IPCR) technique has been developed for detecting DEP in foodstuff samples. Under optimal conditions, a rather low linearity is achieved within a range of 4 pg L−1 to 40 ng L−1, and the limit of detection (LOD) is 1.06 pg L−1. Otherwise, the GNP–rt–IPCR technique is highly selective, with low cross-reactivity values for DEP analogs (<5%). Finally, the concentrations of DEP in foodstuff samples by the GNP–rt–IPCR method range from 0.48 to 41.88 μg kg−1. Satisfactory recoveries (88.39–112.79%) and coefficient of variation values (8.38–12.77%) are obtained. The consistency between the results obtained from GNP–rt–IPCR and gas chromatography–mass spectrometry (GC–MS) is 98.3%, which further proves that GNP–rt–IPCR is an accurate, reliable, rapid, ultrasensitive, and high-throughput method for batch determination of trace amounts of DEP in foodstuff samples.  相似文献   

8.
A new method, based on hollow fiber liquid-phase microextraction (HF-LPME) and gas chromatography–tandem mass spectrometry (GC–MSMS), was developed for determination of Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in samples of human hair. Since hair is a solid matrix, the samples were subjected to alkaline digestion using NaOH. The aqueous solutions obtained were extracted using a 6 cm polypropylene fiber (600 μm i.d., 200 μm wall thickness, 0.2 μm pore size) for each extraction. A 25−1 fractional factorial design for screening, and a central composite design for optimization of significant variables, was applied during development of the extraction method. The variables evaluated were the type of extraction solvent, pH, stirring speed, extraction time, and acceptor phase volume. The optimized conditions for the proposed extraction procedure were 10 mg of hair sample; 20 μL of butyl acetate; aqueous (pH 14) donor phase containing 6.8% NaCl; 600 rpm stirring speed; 20 min extraction time. A linear response was obtained in the ranges 1–500 pg mg−1 (CBD and CBN) and 20–500 pg mg−1 (THC), with regression coefficients >0.99. Precision, determined as the relative standard deviation, was 3.3–8.9% (intra-day) and 4.4–13.7% (inter-day). Absolute recoveries varied in the ranges 4.4–4.8% (CBD), 7.6–8.9% (THC) and 7.7–8.2% (CBN). Limits of detection (LOD, S/N = 3) and quantification (LOQ, S/N = 10) were 0.5–15 pg mg−1 and 1–20 pg mg−1, respectively. The method was successfully used to determine CBD, THC and CBN in hair samples from patients in a drug dependency rehabilitation center. Concentrations varied in the ranges 1–18 pg mg−1 (CBD), 20–232 pg mg−1 (THC) and 9–107 pg mg−1 (CBN), confirming the suitability of the method for monitoring studies.  相似文献   

9.
Tetramethylene disulfotetramine (tetramine) is a rodenticide associated with numerous poisonings was extracted and quantified in human urine using both gas chromatography/mass spectrometry (GC/MS) and GC/tandem mass spectrometry (MS/MS). 1200 μL samples were prepared using a 13C4-labeled internal standard, a 96-well format, and a polydivinyl-benzene solid phase extraction sorbent bed. Relative extraction recovery was greater than 80% at 100 ng/mL. Following extraction, samples were preconcentrated by evaporation at 60 °C, and reconstituted in 50 μL acetonitrile. One-microliter was injected in a splitless mode on both instruments similarly equipped with 30 m × 0.25 mm × 25 μm, 5% phenyl-methylpolysiloxane gas chromatography columns. A quantification ion and a confirmation ion (GC/MS) or analogous selected reaction monitoring transitions (GC/MS/MS) were integrated for all reported results. The method was characterized for precision (5.92–13.4%) and accuracy (96.4–111%) using tetramine-enriched human urine pools between 5 and 250 ng/mL. The method limit of detection was calculated to be 2.34 and 3.87 ng/mL for GC/MS and GC/MS/MS, respectively. A reference range of 100 unexposed human urine samples was analyzed for potential endogenous interferences on both instruments—none were detected. Based on previous literature values for tetramine poisonings, this urinary method should be suitable for measuring low, moderate, and severe tetramine exposures.  相似文献   

10.
Prostate cancer (PCa) is a malignant disease influencing numerous men worldwide every year. However, the exact pathogenesis and the genes, environment, and other factors involved have not been explained clearly. Some studies have proposed that cell signaling pathways might play a key role in the development and progression of PCa. According to our previous study, the RTK/ERK pathway containing nearly 40 genes was associated with PCa risk. On the basis of these genes, we conducted a meta-analysis with our own Chinese Consortium for Prostate Cancer Genetics (ChinaPCa) study and available studies in the databases to describe the association between the pathway and PCa on the SNP level. The results suggested that rs4764695/IGF1 (recessive model: pooled OR = 0.92, 95%CI = 0.852–0.994, P = 0.034; I2 = 0%, P = 0.042; allele analysis: pooled OR = 0.915, 95%CI = 0.874–0.958, P = 0; I2 = 0%, P = 0.424; codominant model: OR = 0.835, 95%CI = 0.762–0.916, P = 0; I2 = 0%, P = 0.684) and rs1570360/VEGF (recessive model: OR = 0.596, 95%CI = 0.421–0.843, P = 0.003; I2 = 23.9%, P = 0.269; codominant model: OR = 0.576, 95%CI = 0.404–0.820, P = 0.002; I2 = 49.1%, P = 0.140) were significantly associated with PCa. In subgroup analysis, the relationship was also found in Caucasians for IGF1 (dominant model: OR = 0.834, 95%CI = 0.769–0.904, P = 0; allele analysis: OR = 0.908, 95%CI = 0.863–0.955, P = 0; AA vs CC: OR = 0.829, 95%CI = 0.750–0.916, P = 0; AC vs CC: OR = 0.837, 95%CI = 0.768–0.912, P = 0). In addition, in Asians (allele analysis: OR = 0.21, 95%CI = 0.168–0.262, P = 0) and Caucasians (recessive model: OR = 0.453, 95%CI: 0.240–0.855, P = 0.015; codominant model: OR = 0.464, 95%CI = 0.240–0.898, P = 0.023) for VEGF, the association was significant. The results indicated that rs4764695/IGF1 and rs1570360/VEGF might play a key role in the development and progression of PCa. On the SNP level, we suggest that the study gives us a new view of gene-pathway analysis and targeted therapy for PCa.  相似文献   

11.
Although recent genome-wide association studies (GWAS) have identified a handful of variants with best significance for coronary artery disease (CAD), it remains a challenge to summarize the underlying biological information from the abundant genotyping data. Here, we propose an integrated network analysis that effectively combines GWAS genotyping dataset, protein–protein interaction (PPI) database, literature and pathway annotation information. This three-step approach was illustrated for a comprehensive network analysis of CAD as the following. First, a network was constructed from PPI database and CAD seed genes mined from the available literatures. Then, susceptibility network modules were captured from the results of gene-based association tests. Finally, susceptibility modules were annotated with potential mechanisms for CAD via the KEGG pathway database. Our network analysis identified four susceptibility modules for CAD including a complex module that consisted of 15 functional inter-connected sub-modules, AGPAT3–AGPAT4–PPAP2B module, ITGA11–ITGB1 module and EMCN–SELL module. MAPK10 and COL4A2 among the top-scored focal adhesion pathway related module were the most significant genes (MAPK10: OR = 32.5, P = 3.5 × 10− 11; COL4A2: OR = 2.7, P = 2.8 × 10− 10). The significance of the two genes were further validated by other two gene-based association tests (MAPK10: P = 0.009 and 0.007; COL4A2: P = 0.001 and 0.023) and another independent GWAS dataset (MAPK10: P = 0.001; COL4A2: P = 0.0004). Furthermore, 34 out of 44 previously reported CAD susceptibility genes were captured by our CAD PPI network and 17 of them were also significant genes. The susceptibility modules identified in our study might provide novel clues for the clarification of CAD pathogenesis in the future.  相似文献   

12.
A rapid, specific, and sensitive method utilizing reversed-phase ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) was developed and validated to determine finasteride levels in human plasma. The plasma samples were prepared by liquid–liquid extraction with ethyl acetate, evaporation, and reconstitution. MS/MS analyses were performed on a triple–quadrupole tandem mass spectrometer by monitoring protonated parent → daughter ion pairs at m/z 373 → 305 for finasteride and m/z 237 → 194 for carbamazepine (internal standard, IS). The method was validated with respect to linearity, recovery, specificity, accuracy, precision, and stability. The method exhibited a linear response from 0.1 to 30 ng/mL (r2 > 0.998). The limit of quantitation for finasteride in plasma was 0.1 ng/mL. The relative standard deviation (RSD) of intra- and inter-day measurements was less than 15% and the method was accurate within −6.0% to 2.31% at all quality-control levels. The mean extraction recovery was higher than 83% for finasteride and 84% for the IS. Plasma samples containing finasteride were stable under the three sets of conditions tested and the processed samples were stable up to 29 h in an autosampler at 5 °C. Detection and quantitation of both analytes within 3 min make this method suitable for high-throughput analyses. The method was successfully applied to a pharmacokinetic study of finasteride in healthy volunteers following oral administration.  相似文献   

13.
Cathepsin S (CTSS) played an important role in the etiology of cardiovascular disease and metabolic syndrome. Few studies had been reported on the association between the polymorphisms of CTSS and metabolic disorders in Asian population. Therefore we explored the association between the polymorphisms of CTSS and metabolic disorders in a Chinese Han population. The subjects were a Chinese Han cohort with 1160 participants, and the genotyping was performed with PCR-RFLP. Polymorphism rs16827671 was associated with BMI and serum total cholesterol (P = 0.001; P = 0.02, respectively). Subjects with CT genotype of rs16827671 had a higher risk of hypercholesterolemia (OR = 1.64, 95% CI: 1.15–2.33, P = 0.006) compared with TT genotype. Subjects with AG genotype of rs11576175 had lower risks of hypertriglyceridemia and borderline hypercholesterolemia (OR = 0.52, 95% CI: 0.36–0.73, P = 0.0001; OR = 0.52, 95% CI: 0.35–0.77, P = 0.001, respectively) compared with GG genotype. Compared with the haplotype TG, haplotype TA had a lower risk of hypertriglyceridemia and a higher risk of borderline hypercholesterolemia (OR = 0.62, 95% CI: 0.44–0.88, P = 0.002; OR = 1.59, 95% CI: 1.10–2.31, P = 0.008, respectively), and haplotype CA had a lower risk of hypercholesterolemia (OR = 0.35, 95% CI: 0.18–0.68, P = 0.002). In conclusion, we found that the genetic polymorphisms of CTSS were associated with metabolic disorders in a Chinese Han population, which would enrich the knowledge on genetic mechanisms of the pathogenesis of metabolic disorders.  相似文献   

14.
We describe an ultra high performance liquid chromatography–tandem mass spectrometry (UHPLC MS/MS) method suitable for a routine laboratory to determine endogenous and exogenous glucocorticoids in plasma, plasma ultrafiltrate, urine and saliva in a single analytical run. After addition of a multi-analyte internal standard, a standardised sample preparation procedure with solid phase extraction followed, before injecting into a tandem mass spectrometer with positive mode electron spray ionisation and multiple reactant monitoring acquisition. The chromatography time was 3 min. The limit of quantitation for cortisol and cortisone in plasma was 3.75 nmol/L and linearity extended to 2000 nmol/L. The limit of quantitation for cortisol in plasma ultrafiltrate and saliva was 0.6 nmol/L. The limit of quantitation for 11-deoxycortisol and prednisolone was 5 nmol/L and for dexamethasone 1 nmol/L. The intra-assay CV was <5% and the inter-assay CV <10% for all analytes in all matrices. Comparison with an immuno-assay (IA) plasma cortisol method resulted in a regression equation of UHPLC = 0.79 × IA + 31.12 with R2 = 0.960 (p < 0.0001). Comparison with a high performance liquid chromatography (HPLC) cortisol method yielded a regression equation of UHPLC = 1.06 × HPLC + 9.82, R2 = 0.992 (p < 0.0001). The simultaneous measurement of endogenous and exogenous glucocorticoids contributed to patient care in cases with dexamethasone and metyrapone dynamic tests and unsuspected therapeutic glucocorticoid use.  相似文献   

15.

Background

Apolipoprotein A5 (APOA5) gene variants are associated with increased plasma triglycerides, a risk factor for metabolic syndrome (MS). The goal of the current study was the investigation of the distribution of T-1131C variant among obese adolescents with MS compared with healthy controls.

Subjects and methods

The study included 150 obese adolescents (75 males and 75 females) with MS and 204 age and sex matched normal healthy controls (100 males and 104 females). The mean age of the patients was 15.47 ± 2.54 years, ranged from 17 to 20 years. They were genotyped by polymerase chain reaction–restriction fragment length polymorphism for the mutation (T-1131C).

Results

The blood pressure, triglyceride and HOMA-R levels were significantly higher and HDL-C levels were significantly lower in carrier (TC + CC) compared to non-carrier (TT) MS patients. There was accumulation of − 1131C allele frequency in the MS group (31.33% vs. control group 11.76%), p < 0.001. The genotypes were in Hardy–Weinberg equilibrium both in the patients with metabolic syndrome and in the control subjects. Results of analysis of multiple regression models showed that the ApoA5 − 1131C carriers showed an increased incidence of MS (OR = 1.73, 95% CI: 1.41–2.11).

Conclusions

The present study suggests that the 1131T>C polymorphism is a risk factor for the development of metabolic syndrome in obese adolescents.  相似文献   

16.
Determination of estrogens in plasma is important in evaluation of effects of some anticancer drugs, such as aromatase inhibitors. However, as reported previously, high performance liquid chromatography–radio immunoassay (HPLC–RIA) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) with chemical derivatization require complicated sample preparation. In this study, a highly sensitive and simple method for determination of estrone (E1), 17β-estradiol (E2) and estrone 3-sulfate (E1S) in human plasma has been developed. Following diethylether extraction from plasma, analytes were purified by immunosorbents and then determined by LC–MS/MS using electrospray ionization (ESI). Immunosorbents were prepared by immobilization of specific antibodies raised against each analyte onto solid support. Use of selective immunosorbents in sample preparation removed interference in plasma samples that would cause ionization suppression, and markedly improved the sensitivity of LC–MS/MS for these analytes, without derivatization. Calibration curves of each analyte showed good linearity and reproducibility over the range of 0.05–50 pg/injection for E1, 0.2–50 pg/injection for E2 and 0.05–300 pg/injection for E1S, respectively. The mean values of lower limits of quantification (LLOQ) in human plasma corrected by recovery of deuterated estrogens (internal standard, I.S.) were 0.1892 pg/mL for E1, 0.7064 pg/mL for E2 and 0.3333 pg/mL for E1S, respectively. These LLOQ values were comparable to those previous reported using HPLC–RIA and LC–MS/MS. Using this method, the normal levels of three estrogens in healthy female plasma (n = 5) were determined. The mean values of E1, E2 and E1S were 38.0 pg/mL (range 24.8–53.0), 34.3 pg/mL (22.6–46.6) and 786 pg/mL (163–2080), respectively. The immunoaffinity LC–MS/MS described here allows sensitive and accurate quantification of E1, E2 and E1S without laborious sample preparation.  相似文献   

17.
Epidemiological studies have evaluated the association between apolipoprotein E (ApoE) gene polymorphism and multiple sclerosis (MS) risk. However, the results remain conflicting. Therefore, in order to derive a more precise association of ApoE gene polymorphism with MS risk, we performed this meta-analysis. Systematic searches of electronic databases PubMed, Embase and Web of Science, as well as hand searching of the references of identified articles were performed. Twenty studies were identified, covering a total of 4080 MS cases and 2897 controls. The results showed evidence for significant association between ApoE ε2 mutation and MS risk (for ε2/ε4 versus ε3/ε3: OR = 1.74, 95% CI = 1.12–2.71, p = 0.01; for ε2 allele versus ε3 allele: OR = 1.16, 95% CI = 1.01–1.35, p = 0.04). In the subgroup analysis by ethnicity, the similar results were obtained among Europeans (for ε2/ε4 versus ε3/ε3: OR = 1.81, 95% CI = 1.14–2.87, p = 0.01; for ε2 allele versus ε3 allele: OR = 1.19, 95% CI = 1.02–1.38, p = 0.03). After excluding the outlier studies by observing Galbraith plot, marginal association was found between ApoE ε3/ε4 genotype and the protective factor for MS (for ε3/ε4 versus ε3/ε3: OR = 0.86, 95% CI = 0.75–0.99, p = 0.04). In summary, the present meta-analysis provides evidence that ApoE ε2 mutation is associated with MS risk. In addition, ApoE ε3/ε4 genotype appears to be a protective factor for MS.  相似文献   

18.
Analysis of catecholamines (epinephrine, norepinephrine and dopamine) in plasma and urine is used for diagnosis and treatment of catecholamine-producing tumors. Current analytical techniques for catecholamine quantification are laborious, time-consuming and technically demanding. Our aim was to develop an automated on-line solid phase extraction method coupled to high performance liquid chromatography–tandem mass spectrometry (XLC–MS/MS) for the quantification of free catecholamines in urine. Five microlitre urine equivalent was pre-purified by automated on-line solid phase extraction, using phenylboronic acid complexation. Reversed phase (pentafluorophenylpropyl column) chromatography was applied. Mass spectrometric detection was operated in multiple reaction monitoring mode using a quadrupole tandem mass spectrometer with positive electrospray ionization. Urinary reference intervals were set in 24-h urine collections of 120 healthy subjects. XLC–MS/MS was compared with liquid chromatography with electrochemical detection (HPLC–ECD). Total run-time was 14 min. Intra- and inter-assay analytical variations were <10%. Linearity was excellent (R2 > 0.99). Quantification limits were 1.47 nmol/L, 15.8 nmol/L and 11.7 nmol/L for epinephrine, norepinephrine and dopamine, respectively. XLC–MS/MS correlated well with HPLC–ECD (correlation coefficient >0.98). Reference intervals were 1–10 μmol/mol, 10–50 μmol/mol and 60–225 μmol/mol creatinine for epinephrine, norepinephrine and dopamine, respectively. Advantages of the XLC–MS/MS catecholamine method include its high analytical performance by selective PBA affinity and high specificity and sensitivity by unique MS/MS fragmentation.  相似文献   

19.
6-Aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) is an amino acid-specific derivatizing reagent that has been used for sensitive amino acid quantification by liquid chromatography–tandem quadrupole mass spectrometry (LC–MS/MS). In this study, we aimed to evaluate the ability of this method to measure the isotopic enrichment of amino acids and to determine the positional 15N enrichment of urea cycle amino acids (i.e., arginine, ornithine, and citrulline) and glutamine. The distribution of the M and M + 1 isotopomers of each natural AQC–amino acid was nearly identical to the theoretical distribution. The standard deviation of the (M + 1)/M ratio for each amino acid in repeated measurements was approximately 0.1%, and the ratios were stable regardless of the injected amounts. Linearity in the measurements of 15N enrichment was confirmed by measuring a series of 15N-labeled arginine standards. The positional 15N enrichment of urea cycle amino acids and glutamine was estimated from the isotopic distribution of unique fragment ions generated at different collision energies. This method was able to identify their positional 15N enrichment in the plasma of rats fed 15N-labeled glutamine. These results suggest the utility of LC–MS/MS detection of AQC–amino acids for the measurement of isotopic enrichment in 15N-labeled amino acids and indicate that this method is useful for the study of nitrogen metabolism in living organisms.  相似文献   

20.
A high-throughput immunosorbent solid-phase extraction (HTS-IS-SPE) procedure coupled to enzyme-linked immunosorbent assay (ELISA) has been established for the analysis of stanozolol (St) and its main metabolite in cattle, 16β-hydroxy-stanozolol (16βOH-St), in cow urine samples. The chemical structure of the immunizing hapten 2′H-androst-2-eno[3,2-c]-pyrazol-17-hemiglutarate 5 (hapten A) has been designed to accomplish simultaneous detection of St and 16βOH-St. The antibodies obtained have been used to establish a microplate ELISA method able to detect these metabolites with IC50 values of 0.57 μg L−1 and 1.46 μg L−1, respectively in PBST. Immunosorbents prepared by covalently attaching the antibodies to Sepharose, efficiently removed the matrix interferences caused by the cattle urine samples. Moreover, St and 16βOH-St were efficiently extracted from urine samples as demonstrated by LC–MS/MS analysis. The immunosorbents are filled on small mini-columns arranges on a 96-SPE-setup compatible with the microplate based ELISA methods. Samples and standards can be run in parallel which increment considerably the speed of the screening method. The recovery values of the whole HTS-IS-SPE-ELISA procedure has found to be 112 ± 10% and St can be detected in hydrolyzed urine samples with LOD of 1.26 ± 0.46 μg L−1 using just 1 mL of sample. As proof-of-concept the urinary excretion profile of St treated animals has been investigated by analyzing individual sampling points. Results from pooled urine samples have also been compared with the results obtained by GC–MS analysis demonstrating the StIR equiv. measured with the HTS-IS-SPE-ELISA protocol are in accordance with the St and 16βOH-St levels found with the chromatographic method. The analytical procedure is rapid, effective and the detectability achieved is below the MPRL (minimum performance required levels) recommended by CRL (Community Reference Laboratory) to the European Community.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号