1.
A novel DNAzyme-functionalized Pt nanoparticles/carbon nanotubes (DNAzyme/Pt NPs/CNTs) bioconjugate was fabricated as trace tag for ultrasensitive sandwich DNA detection. The Pt NPs/CNTs were prepared via layer-by-layer (LBL) assembly of the Pt NPs and polyelectrolyte on the carboxylated CNTs, followed by the functionalization with the DNAzyme and reporter probe DNA through the platinum-sulfur bonding. The subsequent sandwich-type DNA specific reaction would confine numerous DNAzyme/Pt NPs/CNTs bioconjugate onto the gold electrode surface for amplifying the signal. In the presence of 3,3',5,5' tetramethylbenzidine (TMB) which could be oxidized by the DNAzyme, electrochemical signals could be generated by chronoamperometry via the interrogation of reduction electrochemical signal of oxidized TMB. The constructed DNA sensor exhibited a wide linear response to target DNA ranging from 1.0fM to 10pM with the detection limit down to 0.6fM and exhibited excellent selectivity against even a single base mismatch. In addition, this novel DNA sensor showed fairly good reproducibility, stability, and reusability.  相似文献   

2.
A hybridisation-based genosensor was designed on a 100 nm sputtered gold film. This material worked as an immobilisation and transduction surface. A 30-mer sequence that encodes a short lysine-rich region, unique to SARS (severe acute respiratory syndrome) virus, was chosen as target. A complementary strand (probe), labelled with a thiol group at the 3'-end, was immobilised on the film. After blocking the surface, hybridisation with the biotin-conjugated SARS strand (at the 3'-end) took place. Interaction with alkaline phosphatase-labelled streptavidin permits amplified indirect electrochemical detection. The analytical signal is constituted by an electrochemical process of indigo carmine, the soluble product of the enzymatic hydrolysis of 3-indoxyl phosphate. The use of a sensitive electrochemical technique such as square wave voltammetry allowed a detection limit of 6 pM to be obtained for this DNA sequence, lower than any other found in the bibliography. The parameters affecting the methodology were studied, with special attention being placed on selectivity. Specificity was clearly enhanced when interaction time and stringency (in the form of formamide percentage) were increased. With 1h of strand interaction and employing 50% of formamide in the hybridisation buffer, a 3-base mismatch strand was perfectly distinguished from the complementary.  相似文献   

3.
We herein report an electrochemical biosensor for the sequence-specific detection of DNA with high discrimination ability for single-nucleotide polymorphisms (SNPs). This DNA sensor was constructed by a pair of flanking probes that "sandwiched" the target. A 16-electrode electrochemical sensor array was employed, each having one individual DNA capture probe immobilized at gold electrodes via gold-thiol chemistry. By coupling with a biotin-tagged detection probe, we were able to detect multiple DNA targets with a single array. In order to realize SNP detection, a ligase-based approach was employed. In this method, both the capture probe and the detection probe were in tandem upon being hybridized with the target. Importantly, we employed a ligase that specifically could ligate tandem sequences only in the absence of mismatches. As a result, when both probes were complementary to the target, they were ligated in the presence of the ligase, thus being retained at the surface during the subsequent stringent washing steps. In contrast, if there existed 1-base mismatch, which could be efficiently recognized by the ligase, the detection probe was not ligated and subsequently washed away. A conjugate of avidin-horseradish peroxidase was then attached to the biotin label at the end of the detection probe via the biotin-avidin bridge. We then electrochemically interrogated the electrical current for the peroxidase-catalyzed reduction of hydrogen peroxide. We demonstrated that the electrochemical signal for the wild-type DNA was significantly larger than that for the sequence harboring the SNP.  相似文献   

4.
In this study, a novel DNA electrochemical probe (locked nucleic acid, LNA) was designed and involved in constructing an electrochemical DNA biosensor for detection of promyelocytic leukemia/retinoic acid receptor alpha (PML/RARα) fusion gene in acute promyelocytic leukemia for the first time. This biosensor was based on a 'sandwich' sensing mode, which involved a pair of LNA probes (capture probe immobilized at electrode surface and biotinyl reporter probe as an affinity tag for streptavidin-horseradish peroxidase (streptavidin-HRP). Since biotin can be connected with streptavidin-HRP, this biosensor offered an enzymatically amplified electrochemical current signal for the detection of target DNA. In the simple hybridization system, DNA fragment with its complementary DNA fragment was evidenced by amperometric detection, with a detection limit of 74 fM and a linear response range of 0.1-10 pM for synthetic PML/RARα fusion gene in acute promyelocytic leukemia (APL). Otherwise, the biosensor showed an excellent specificity to distinguish the complementary sequence and different mismatch sequences. The new pattern also exhibited high sensitivity and selectivity in mixed hybridization system.  相似文献   

5.
We previously prepared the oligonucleotides (ODNs) conjugated to an anthraquinone (AQ) group via one carbon linker at the 2'-sugar position. When these modified ODNs bind to cDNA sequences, the AQ moiety can be intercalated into the predetermined base-pair pocket of a duplex DNA. In this paper, 2'-AQ-modified ODNs are shown to be an excellent electrochemical probe to clarify the effect of a mismatch base on the charge transfer (CT) though DNA. Two types of DNA-modified electrodes were constructed by assembly of disulfide-terminated 2'-AQ-ODN duplexes onto gold electrodes. One type of electrodes (system I) contains fully matched base pairs or a single-base mismatch in duplex DNA between the redox center and the electrode. The other (system II) consists of the mismatch but at the outside of the redox center. The modified electrodes were analyzed by cyclic voltammetry to estimate the CT rate through duplex DNA. In system I, the CT rate was found to be approximately 50 s (-1) for the fully matched AQ-ODN duplexes, while the CT rates of the mismatched DNA were considerably slower than that of the fully matched DNA. In system II, the AQ-ODN duplexes showed almost similar CT rates ( approximately 50 s (-1)) for the fully matched DNA and for the mismatched DNAs. The detection of a single-base mismatch was then performed by chronocoulometry (CC). All the DNA duplexes containing a mismatch base in system I gave the reduced electrochemical responses when compared to the fully matched DNA. In particular, the mismatched DNAs including G--A mismatch can be differentiated from fully matched DNA without using any electrochemical catalyst. We further tested the usefulness of single-stranded (ss) AQ-ODN immobilized on a gold electrode in the electrochemical detection of a single-base mismatch through hybridization assay. The ss-AQ-ODN electrodes were immersed in target-containing buffer at room temperature, and the CC measurements were carried out to see the changes in the integrated charge. Within 60 min, the mismatched DNA was clearly distinguishable by the CC differences from the fully matched target. Thus, the electrochemical hybridization assay provides an easy and convenient detection for DNA mutation that does not require any extra reagents, catalyst, target labeling, and washing steps.  相似文献   

6.
A fluorescent in situ hybridization assay has been developed for the detection of the human-pathogenic microsporidian, Encephalitozoon hellem in water samples using epifluorescence microscopy. The assay employs a 19-nucleotide species-specific 6-carboxyfluorescein-labeled oligonucleotide probe, HEL878F, designed to be complementary to the nucleic acid sequence 878-896, a highly variable segment of the 16S ribosomal RNA of E. hellem spores. The specificity of this probe for its ribosomal RNA target site was confirmed using RNA degradation, ribosomal RNA target site competition, and nucleotide base mismatch control probe assays. Furthermore, the specificity of the HEL878F oligonucleotide probe for E. hellem spores was established when it was evaluated on spores from all three species of the genus Encephalitozoon that had been seeded in reagent water and environmental water concentrates. The specificity of the HEL878F oligonucleotide probe was further corroborated when tested on algae, bacteria, and protozoa commonly found in environmental water. The study demonstrates the applicability of a fluorescent in situ hybridization assay using a species-specific fluorescent-labeled oligonucleotide probe for the detection of E. hellem spores in water samples.  相似文献   

7.
An electrochemical DNA sensing technique was developed by using ferrocenyl naphthalene diimide coupled with a probe DNA-immobilized electrode. This technique enabled detection of target DNA quickly and with high sensitivity. Applicability of this technique for single nucleotide polymorphisms (SNPs) analysis was demonstrated by successful analysis of a DNA mismatch on the cancer repression gene p53 with high precision.  相似文献   

8.
An electrochemical DNA sensing technique was developed by using ferrocenyl naphthalene diimide coupled with a probe DNA-immobilized electrode. This technique enabled detection of target DNA quickly and with high sensitivity. Applicability of this technique for single nucleotide polymorphisms (SNPs) analysis was demonstrated by successful analysis of a DNA mismatch on the cancer repression gene p53 with high precision.  相似文献   

9.
For the detection of DNA hybridization, a new electrochemical biosensor was developed on the basis of the interaction of hematoxylin with 20-mer deoxyoligonucleotides (from human papilloma virus, HPV). The study was performed based on the interaction of hematoxylin with an alkanethiol DNA probe self-assembled gold electrode (ss-DNA/AuE) and its hybridization form (ds-DNA/AuE). The optimum conditions were found for the immobilization of HPV probe on the gold electrode (AuE) surface and its hybridization with the target DNA. Electrochemical detection of the self-assembled DNA and the hybridization process were performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) over the potential range where the accumulated hematoxylin at the modified electrode was electroactive. Observing a remarkable difference between the voltammetric signals of the hematoxylin obtained from different hybridization samples (non-complementary, mismatch and complementary DNAs), we confirmed the potential of the developed biosensor in detecting and discriminating the target complementary DNA from non-complementary and mismatch oligonucleotides. Under optimum conditions, the electrochemical signal had a linear relationship with the concentration of the target DNA ranging from 12.5 nM to 350.0 nM, and the detection limit was 3.8 nM.  相似文献   

10.
A new approach to electronic detection of a single base mismatch is described. The assay involves the electrochemical measurements of DNA strand exchange reactions (SERs) between electrode-bound redox-modified DNA duplex and target DNA, where the sequence of redox-modified DNA is exchangeable to that of the target DNA. The presence of a single base mismatch can be determined from the slower SER rates compared with fully matched DNA.  相似文献   

11.
DNA methylation is a key diagnostic maker for genetic disease, cancer progression and pharmcogenomics. So far various techniques have been developed for DNA methylation assay, but most of them are laborious and time-consuming. Here we develop a simple and highly sensitive DNA methylation assay based on single base extension reaction and surface enhanced Raman spectroscopy (SERS). In the presence of methylated DNA, gold nanoparticle-modified capture probe can couple with a cyanine 5-deoxyribonucleoside triphosphate (cy5-dGTP) through single base extension reaction, and generates a high SERS signal after further addition of gold nanoparticles to increase the local electromagnetic field. While in the presence of unmethylated DNA, gold nanoparticle-modified capture probe cannot couple with cy5-dGTP due to the presence of a mismatch base, and no SERS signal is observed. This single base extension reaction-based SERS can determine methylated DNA with a detection limit of 3 pM, and can even distinguish as low as 1% methylation level in tumor suppressor gene CDKN2/p16/MTS1 (p16) from the mixtures. Notably, the sensitivity of this assay has improved by 5 orders of magnitude as compared to reported gold nanoparticle-based colorimetric assay, and by 2 orders of magnitude as compared to microarray-based methylation-sensitive single nucleotide primer extension assay (Ms-SNuPE). This method might be further applied to detect the methylation status in tumor-linked genes for cancer diagnosis.  相似文献   

12.
An electrochemical DNA sensor based on the hybridization recognition of a single-stranded DNA (ssDNA) probe immobilized onto a gold electrode to its complementary ssDNA is presented. The DNA probe is bound on gold surface electrode by using self-assembled monolayer (SAM) technology. An optimized mixed SAM with a blocking molecule preventing the nonspecific adsorption on the electrode surface has been prepared. In this paper, a DNA biosensor is designed by means of the immobilization of a single stranded DNA probe on an electrochemical transducer surface to recognize specifically Escherichia coli (E. coli) 0157:H7 complementary target DNA sequence via cyclic voltammetry experiments. The 21 mer DNA probe including a C6 alkanethiol group at the 5' phosphate end has been synthesized to form the SAM onto the gold surface through the gold sulfur bond. The goal of this paper has been to design, characterise and optimise an electrochemical DNA sensor. In order to investigate the oligonucleotide probe immobilization and the hybridization detection, experiments with different concentration of DNA and mismatch sequences have been performed. This microdevice has demonstrated the suitability of oligonucleotide Self-assembled monolayers (SAMs) on gold as immobilization method. The DNA probes deposited on gold surface have been functional and able to detect changes in bases sequence in a 21-mer oligonucleotide.  相似文献   

13.
We developed a novel electrochemical sensor for Hg(2+) detection using two mercury-specific oligonucleotide probes and streptavidin-horseradish peroxidase (HRP) enzymatic signal amplification. The two mercury-specific oligonucleotide probes comprised a thiolated capture probe and a biotinated signal probe. The thiolated capture probe was immobilized on a gold electrode. In the presence of Hg(2+), the thymine-Hg(2+)-thymine (T-Hg(2+)-T) interaction between the mismatched T-T base pairs directed the biotinated signal probe hybridizing to the capture probe and yielded a biotin-functioned electrode surface. HRP was then immobilized on the biotin-modified substrate via biotin-streptavidin interaction. The immobilized HRP catalyzed the oxidation of hydroquinone (H(2)Q) to benzoquinone (BQ) by hydrogen peroxide (H(2)O(2)) and the generated BQ was further electrochemically reduced at the modified gold electrode, producing a readout signal for quantitative detection of Hg(2+). The results showed that the enzyme-amplified electrochemical sensor system was highly sensitive to Hg(2+) in the concentration of 0.5 nM to 1 μM with a detection limit of 0.3 nM, and it also demonstrated excellent selectivity against other interferential metal ions.  相似文献   

14.
In this work, a gold complex is used as electroactive label for monitoring hybridization assays on glassy carbon electrodes. Ionic gold is bound to a 30-mer sequence of the SARS (severe acute respiratory syndrome) virus, responsible for the atypical pneumonia, using sodium aurothiomalate. In order to label this single strand, a mixture of sodium aurothiomalate and the strand is prepared. Then, it is incubated for 24 h at 37 degrees C and, finally, free gold is separated from the labeled strand by a dialysis against a 0.15M NaCl solution (pH 7.5). The DNA hybridization sensor is designed immobilizing the complementary probe on the pre-treated electrode surface and, then, the hybridization reaction takes place with the gold labeled strand. The electrochemical determination is based on the catalytic effect of electrodeposited gold on the reduction of silver ions. In non-stringent experimental conditions, a limit of detection of 15 fmol (30 microL) is obtained, and discrimination between a complementary oligonucleotide and a three-based mismatch complementary oligonucleotide is achieved. For the discrimination of a single-base mismatch, is needed to use stringent conditions (50% of formamide in the hybridization buffer).  相似文献   

15.
In this paper, we constructed a new electrochemical biosensor for DNA detection based on a molecule recognition technique. In this sensing protocol, a novel dual-labeled DNA probe (DLP) in a stem–loop structure was employed, which was designed with dabcyl labeled at the 3′ end as a guest molecule, and with a Pb nanoparticle labeled at the 5′ end as electrochemical tag to indicate hybridization. One α-cyclodextrin-modified electrode (α-CD/MCNT/GCE) was used for capturing the DNA hybridization. Initially, the DLP was in the “closed” state in the absence of the target, which shielded dabcyl from the bulky α-CD/MCNT/GCE conjugate due to a steric effect. After hybridization, the loop sequence (16 bases) formed a rigid duplex with the target, breaking the relatively shorter stem duplex (6 bases). Consequently, dabcyl was forced away from the Pb nanoparticle and became accessible by the electrode. Therefore, the target hybridization event can be sensitively transduced via detecting the electrochemical reduction current signal of Pb. Using this method, as low as 7.1 × 10−10 M DNA target had been detected with excellent differentiation ability for even a single mismatch.  相似文献   

16.
DNA hybridization and enzymatic digestion for the detection of mutation was investigated on the gold nanoparticles-calf thymus DNA (AuNPs-ctDNA) modified glassy carbon electrode (GCE). The thiol modified probe oligonucleotides (SH-ssDNA) were assembled on the surface of AuNPs-ctDNA modified GCE. The electrochemical response of the electrode was measured by differential pulse voltammetry and cyclic voltammetry. Methylene blue (MB) was used as the electroactive indicator. AuNPs were then dispersed effectively on the GCE surface in the presence of ct-DNA. When hybridization occurred, a decrease in the signal of MB current was observed. The modified electrode was used for the detection of mutations during the enzymatic digestion reaction in DNA. During this reaction, an increase in the signal of MB current was observed. So, the modified SH-ssDNA had a higher electrochemical response on the AuNPs-ctDNA/GCE because of the strong affinity of MB for guanine residues in it. The electrochemical detection of restriction enzyme digestion can provide a simple and practical method for observing single-base mismatches that can help in distinguishing mismatch sequences of DNA from the complementary ones.  相似文献   

17.
18.
A label-free electrochemical method for the detection of DNA-PNA hybridization using a water-soluble, ferrocene-functionalized polythiophene transducer and single-stranded PNA probes on the nanogold modified electrode is investigated. Nanogold modified electrodes can largely increase the immobilization amount of ss-PNA capture probe and lead to an increase of the electrical signal. The ferrocene-containing cationic polythiophene do not interact electrostatically with the PNA probes due to the absence of the anionic phosphate groups on the PNA probes. But after DNA-PNA hybridization, cationic polythiophene is adsorbed on the DNA backbone, giving a clear hybridization detection signal in differential pulse voltammetry (DPV). Very good discrimination against non-complementary DNA and four-base mismatch DNA is observed. These studies show that the proposed method can provide an alternative for expanding the range of detection methods available for DNA hybridization.  相似文献   

19.
We demonstrate a novel protocol for sensitive in situ label-free electrochemical detection of DNA hybridization based on copper complex ([Cu(phen)2]2+, where phen = 1,10-phenanthroline) and graphene (GR) modified glassy carbon electrode. Here, [Cu(phen)2]2+ acted advantageously as both the electrochemical indicator and the anchor for probe DNA immobilization via intercalative interactions between the partial double helix structure of probe DNA and the vertical aromatic groups of phen. GR provided large density of docking site for probe DNA immobilization and increased the electrical conductivity ability of the electrode. The modification procedure was monitored by electrochemical impedance spectroscopy (EIS). Square-wave voltammetry (SWV) was used to explore the hybridization events. Under the optimal conditions, the designed electrochemical DNA biosensor could effectively distinguish different mismatch degrees of complementary DNA from one-base mismatch to noncomplementary, indicating that the biosensor had high selectivity. It also exhibited a reasonable linear relationship. The oxidation peak currents of [Cu(phen)2]2+ were linear with the logarithm of the concentrations of complementary target DNA ranging from 1 × 10−12 to 1 × 10−6 M with a detection limit of 1.99 × 10−13 M (signal/noise = 3). Moreover, the stability of the electrochemical DNA biosensor was also studied.  相似文献   

20.
A sensitive and selective genomagnetic assay for the electrochemical detection of food pathogens based on in situ DNA amplification with magnetic primers has been designed. The performance of the genomagnetic assay was firstly demonstrated for a DNA synthetic target by its double-hybridization with both a digoxigenin probe and a biotinylated capture probe, and further binding to streptavidin-modified magnetic beads. The DNA sandwiched target bound on the magnetic beads is then separated by using a magneto electrode based on graphite-epoxy composite. The electrochemical detection is finally achieved by an enzyme marker, anti-digoxigenin horseradish peroxidase (HRP). The novel strategy was used for the rapid and sensitive detection of polymerase chain reaction (PCR) amplified samples. Promising resultants were also achieved for the DNA amplification directly performed on magnetic beads by using a novel magnetic primer, i.e., the up PCR primer bound to magnetic beads. Moreover, the magneto DNA biosensing assay was able to detect changes at single nucleotide polymorphism (SNP) level, when stringent hybridization conditions were used. The reliability of the assay was tested for Salmonella spp., the most important pathogen affecting food safety.  相似文献   