首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Under fast dynamic loading conditions (e.g. high-energy impact), the load rate dependency of the intervertebral disc (IVD) material properties may play a crucial role in the biomechanics of spinal trauma. However, most finite element models (FEM) of dynamic spinal trauma uses material properties derived from quasi-static experiments, thus neglecting this load rate dependency. The aim of this study was to identify hyperelastic material properties that ensure a more biofidelic simulation of the IVD under a fast dynamic compressive load. A hyperelastic material law based on a first-order Mooney-Rivlin formulation was implemented in a detailed FEM of a L2-L3 functional spinal unit (FSU) to represent the mechanical behavior of the IVD. Bony structures were modeled using an elasto-plastic Johnson-Cook material law that simulates bone fracture while ligaments were governed by a viscoelastic material law. To mimic experimental studies performed in fast dynamic compression, a compressive loading velocity of 1 m/s was applied to the superior half of L2, while the inferior half of L3 was fixed. An exploratory technique was used to simulate dynamic compression of the FSU using 34 sets of hyperelastic material constants randomly selected using an optimal Latin hypercube algorithm and a set of material constants derived from quasi-static experiments. Selection or rejection of the sets of material constants was based on compressive stiffness and failure parameters criteria measured experimentally. The two simulations performed with calibrated hyperelastic constants resulted in nonlinear load-displacement curves with compressive stiffness (7335 and 7079 N/mm), load (12,488 and 12,473 N), displacement (1.95 and 2.09 mm) and energy at failure (13.5 and 14.7 J) in agreement with experimental results (6551 ± 2017 N/mm, 12,411 ± 829 N, 2.1 ± 0.2 mm and 13.0 ± 1.5 J respectively). The fracture pattern and location also agreed with experimental results. The simulation performed with constants derived from quasi-static experiments showed a failure energy (13.2 J) and a fracture pattern and location in agreement with experimental results, but a compressive stiffness (1580 N/mm), a failure load (5976 N) and a displacement to failure (4.8 mm) outside the experimental corridors. The proposed method offers an innovative way to calibrate the hyperelastic material properties of the IVD and to offer a more realistic simulation of the FSU in fast dynamic compression.  相似文献   

2.
A comprehensive study on the spherical indentation of hyperelastic soft materials is carried out through combined theoretical, computational, and experimental efforts. Four widely used hyperelastic constitutive models are studied, including neo-Hookean, Mooney–Rivlin, Fung, and Arruda–Boyce models. Through dimensional analysis and finite element simulations, we establish the explicit relations between the indentation loads at given indentation depths and the constitutive parameters of materials. Based on the obtained results, the applicability of Hertzian solution to the measurement of the initial shear modulus of hyperelastic materials is examined. Furthermore, from the viewpoint of inverse problems, the possibility to measure some other properties of a hyperelastic material using spherical indentation tests, e.g., locking stretch, is addressed by considering the existence, uniqueness, and stability of the solution. Experiments have been performed on polydimethylsiloxane to validate the conclusions drawn from our theoretical analysis. The results reported in this study should help identify the extent to which the mechanical properties of hyperelastic materials could be measured from spherical indentation tests.  相似文献   

3.
Supraspinatus tendon tears are common and often propagate into larger tears that include the infraspinatus tendon, resulting in loss of function and increased pain. Previously, we showed that the supraspinatus and infraspinatus tendons mechanically interact through a range of rotation angles, potentially shielding the torn supraspinatus tendon from further injury while subjecting the infraspinatus tendon to increased risk of injury. Surgical repair of torn supraspinatus tendons is common, yet the effect of the repair on the infraspinatus tendon is unknown. Since we have established a relationship between strain in the supraspinatus and infraspinatus tendons the success of a supraspinatus tendon repair depends on its effect on the loading environment in the infraspinatus tendon. More specifically, the effect of transosseous supraspinatus tendon repair in comparison to one that utilizes suture anchors, as is commonly done with arthroscopic repairs, on this interaction through these joint positions will be evaluated. We hypothesize that at all joint positions evaluated, both repairs will restore the interaction between the two tendons. For both repairs, (1) increasing supraspinatus tendon load will increase infraspinatus tendon strain and (2) altering the rotation angle from internal to external will increase strain in the infraspinatus tendon. Strains were measured in the infraspinatus tendon insertion through a range of joint rotation angles and supraspinatus tendon loads, for the intact, transosseous, and suture anchor repaired supraspinatus tendons. Images corresponding to specific supraspinatus tendon loads were isolated for the infraspinatus tendon insertion for analysis. The effect of supraspinatus tendon repair on infraspinatus tendon strain differed with joint position. Altering the joint rotation did not change strain in the infraspinatus tendon for any supraspinatus tendon condition. Finally, increasing supraspinatus tendon load resulted in an increase in average maximum and decrease in average minimum principal strain in the infraspinatus tendon. There is a significant difference in infraspinatus tendon strain between the intact and arthroscopically (but not transosseous) repaired supraspinatus tendons that increases with greater loads. Results suggest that at low loads neither supraspinatus tendon repair technique subjects the infraspinatus tendon to potentially detrimental loads; however, at high loads, transosseous repairs may be more advantageous over arthroscopic repairs for the health of the infraspinatus tendon. Results emphasize the importance of limiting loading of the repaired supraspinatus tendon and that at low loads, both repair techniques restore the interaction to the intact supraspinatus tendon case.  相似文献   

4.
Carpal tunnel syndrome is a frequently encountered peripheral nerve disorder caused by mechanical insult to the median nerve, which may in part be a result of impingement by the adjacent digital flexor tendons. Realistic finite element (FE) analysis to determine contact stresses between the flexor tendons and median nerve depends upon the use of physiologically accurate material properties. To assess the transverse compressive properties of the digital flexor tendons and median nerve, these tissues from ten cadaveric forearm specimens were compressed transversely while under axial load. The experimental compression data were used in conjunction with an FE-based optimization routine to determine apparent hyperelastic coefficients (μ and α) for a first-order Ogden material property definition. The mean coefficient pairs were μ=35.3 kPa, α=8.5 for the superficial tendons, μ=39.4 kPa, α=9.2 for the deep tendons, μ=24.9 kPa, α=10.9 for the flexor pollicis longus (FPL) tendon, and μ=12.9 kPa, α=6.5 for the median nerve. These mean Ogden coefficients indicate that the FPL tendon was more compliant at low strains than either the deep or superficial flexor tendons, and that there was no significant difference between superficial and deep flexor tendon compressive behavior. The median nerve was significantly more compliant than any of the flexor tendons. The material properties determined in this study can be used to better understand the functional mechanics of the carpal tunnel soft tissues and possible mechanisms of median nerve compressive insult, which may lead to the onset of carpal tunnel syndrome.  相似文献   

5.
The heterogeneous composition and mechanical properties of the supraspinatus tendon offer an opportunity for studying the structure-function relationships of fibrous musculoskeletal connective tissues. Previous uniaxial testing has demonstrated a correlation between the collagen fiber angle distribution and tendon mechanics in response to tensile loading both parallel and transverse to the tendon longitudinal axis. However, the planar mechanics of the supraspinatus tendon may be more appropriately characterized through biaxial tensile testing, which avoids the limitation of nonphysiologic traction-free boundary conditions present during uniaxial testing. Combined with a structural constitutive model, biaxial testing can help identify the specific structural mechanisms underlying the tendon's two-dimensional mechanical behavior. Therefore, the objective of this study was to evaluate the contribution of collagen fiber organization to the planar tensile mechanics of the human supraspinatus tendon by fitting biaxial tensile data with a structural constitutive model that incorporates a sample-specific angular distribution of nonlinear fibers. Regional samples were tested under several biaxial boundary conditions while simultaneously measuring the collagen fiber orientations via polarized light imaging. The histograms of fiber angles were fit with a von Mises probability distribution and input into a hyperelastic constitutive model incorporating the contributions of the uncrimped fibers. Samples with a wide fiber angle distribution produced greater transverse stresses than more highly aligned samples. The structural model fit the longitudinal stresses well (median R(2) ≥ 0.96) and was validated by successfully predicting the stress response to a mechanical protocol not used for parameter estimation. The transverse stresses were fit less well with greater errors observed for less aligned samples. Sensitivity analyses and relatively affine fiber kinematics suggest that these errors are not due to inaccuracies in measuring the collagen fiber organization. More likely, additional strain energy terms representing fiber-fiber interactions are necessary to provide a closer approximation of the transverse stresses. Nevertheless, this approach demonstrated that the longitudinal tensile mechanics of the supraspinatus tendon are primarily dependent on the moduli, crimp, and angular distribution of its collagen fibers. These results add to the existing knowledge of structure-function relationships in fibrous musculoskeletal tissue, which is valuable for understanding the etiology of degenerative disease, developing effective tissue engineering design strategies, and predicting outcomes of tissue repair.  相似文献   

6.
Partial-thickness tears of the supraspinatus tendon frequently occur at its insertion on the greater tubercule of the humerus, causing pain and reduced strength and range of motion. The goal of this work was to quantify the loss of loading capacity due to tendon tears at the insertion area. A finite element model of the supraspinatus tendon was developed using in vivo magnetic resonance images data. The tendon was represented by an anisotropic hyperelastic constitutive law identified with experimental measurements. A failure criterion was proposed and calibrated with experimental data. A partial-thickness tear was gradually increased, starting from the deep articular-sided fibres. For different values of tendon tear thickness, the tendon was mechanically loaded up to failure. The numerical model predicted a loss in loading capacity of the tendon as the tear thickness progressed. Tendon failure was more likely when the tendon tear exceeded 20%. The predictions of the model were consistent with experimental studies. Partial-thickness tears below 40% tear are sufficiently stable to persist physiotherapeutic exercises. Above 60% tear surgery should be considered to restore shoulder strength.  相似文献   

7.
Although we sometimes use the intrasynovial tendon allograft as a donor, the gliding ability of allograft prepared by lyophilization is significantly decreased. The gliding ability of the grafted tendon after tendon reconstruction is very important because the high gliding resistance causes more adhesion and leads to poor clinical results. We recently revealed that tendon surface treatment with a carbodiimide derivatized HA (cd-HA)-gelatin mixture for intrasynovial tendon allograft significantly improved its gliding ability. The purpose of this study was to investigate whether this cd-HA-gelatin treatment affects the tendon mechanical property or not. A total of 40 flexor digitorum profundus (FDP) tendons from canines were evaluated for compressive property by using indentation test. Indentation stiffness was measured for normal tendon, rehydrated tendon after lyophilization, rehydrated tendon after lyophilization that was implanted 6 weeks in vivo, and cd-HA treated rehydrated tendon after lyophilization that was implanted 6 weeks in vivo. The results for all groups showed no significant difference in the tendon compressive properties. The findings of these results demonstrate that cd-HA treatment for intrasynovial tendon allograft is an excellent method to improve the tendon gliding ability after lyophilization without changing the compressive property of donor tendon.  相似文献   

8.
The objective of this study was to investigate the effects of doxycycline, a broad-spectrum MMP inhibitor, on cage activity and exercised supraspinatus tendon and muscle using a Sprague-Dawley rat model of non-injurious exercise. Because exercise may alter muscle and tendon MMP activity and matrix turnover, we hypothesized that doxycycline would abolish the beneficial adaptations found with exercise but have no effect on cage activity muscle and tendon properties. Rats were divided into acute or chronic exercise (EX) or cage activity (CA) groups, and half of the rats received doxycycline orally. Animals in acute EX groups were euthanized 24 h after a single bout of exercise (10 m/min, 1 h) on a flat treadmill. Animals in chronic EX groups walked on a flat treadmill and were euthanized at 2 or 8 week time points. Assays included supraspinatus tendon mechanics and histology and muscle fiber morphologic and type analysis. Doxycycline improved tendon mechanical properties and collagen organization in chronic cage activity groups, which was not consistently evident in exercised groups. Combined with exercise, doxycycline decreased average muscle fiber cross-sectional area. Results of this study suggest that administration of doxycycline at pharmaceutical doses induces beneficial supraspinatus tendon adaptations without negatively affecting the muscle in cage activity animals, supporting the use of doxycycline to combat degenerative processes associated with underuse; however, when combined with exercise, doxycycline does not consistently produce the same beneficial adaptations in rat supraspinatus tendons and reduces muscle fiber cross-sectional area, suggesting that doxycycline is not advantageous when combined with activity.  相似文献   

9.
A non-anatomical reinsertion of the supraspinatus medially to the original footprint to avoid over-tensioning of the tendon in large and retracted tears is one surgical option in rotator cuff (RC) repair. The purpose of the study was to determine the biomechanical effects on the glenohumeral joint with regard to this surgical technique. A modified musculoskeletal computational shoulder model was used to evaluate the change in moment arms and muscle forces of the RC and the co-contracting muscles and the alteration of the joint reaction forces (compressive and shear forces) after reinsertion of the supraspinatus 5?mm, 10?mm, 15?mm and 20?mm medially to the original footprint. A medialization of the supraspinatus reduces its moment arm in glenohumeral abduction. In case of a medialization of the attachment of 15?mm and 20?mm, the supraspinatus restricts glenohumeral abduction at 54° and 68°. In glenohumeral forward flexion and in lower degrees of internal rotation the moment arm of the supraspinatus increases for a medialized tendon attachment and decreases in external rotation in relation to the anatomical condition. A medialization of the supraspinatus insertion point yields in an increase in muscle force for abduction, internal and external rotation. In the present model a medially non-anatomic reinsertion reduces significantly the compressive glenohumeral joint reaction and the glenohumeral stability. Moreover, the results show that a medialization of the supraspinatus leads to a reduction of the supraspinatus moment arm especially in abduction. This leads to an increase of a compensatory supraspinatus load for stabilization the humerus in space, which may potentially cause a postoperative overload of the tendon-bone-complex.  相似文献   

10.
We hypothesize that both compression and elongation stress–strain data should be considered for modeling and simulation of soft tissue indentation. Uniaxial stress–strain data were obtained from in vitro loading experiments of porcine liver tissue. An axisymmetric finite element model was used to simulate liver tissue indentation with tissue material represented by hyperelastic models. The material parameters were derived from uniaxial stress–strain data of compressions, elongations, and combined compression and elongation of porcine liver samples. in vitro indentation tests were used to validate the finite element simulation. Stress–strain data from the simulation with material parameters derived from the combined compression and elongation data match the experimental data best. This is due to its better ability in modeling 3D deformation since the behavior of biological soft tissue under indentation is affected by both its compressive and tensile characteristics. The combined logarithmic and polynomial model is somewhat better than the 5-constant Mooney–Rivlin model as the constitutive model for this indentation simulation.  相似文献   

11.
Characterizing compressive transient large deformation properties of biological tissue is becoming increasingly important in impact biomechanics and rehabilitation engineering, which includes devices interfacing with the human body and virtual surgical guidance simulation. Individual mechanical in vivo behaviour, specifically of human gluteal adipose and passive skeletal muscle tissue compressed with finite strain, has, however, been sparsely characterised. Employing a combined experimental and numerical approach, a method is presented to investigate the time-dependent properties of in vivo gluteal adipose and passive skeletal muscle tissue. Specifically, displacement-controlled ramp-and-hold indentation relaxation tests were performed and documented with magnetic resonance imaging. A time domain quasi-linear viscoelasticity (QLV) formulation with Prony series valid for finite strains was used in conjunction with a hyperelastic model formulation for soft tissue constitutive model parameter identification and calibration of the relaxation test data. A finite element model of the indentation region was employed. Strong non-linear elastic but linear viscoelastic tissue material behaviour at finite strains was apparent for both adipose and passive skeletal muscle mechanical properties with orthogonal skin and transversal muscle fibre loading. Using a force-equilibrium assumption, the employed material model was well suited to fit the experimental data and derive viscoelastic model parameters by inverse finite element parameter estimation. An individual characterisation of in vivo gluteal adipose and muscle tissue could thus be established. Initial shear moduli were calculated from the long-term parameters for human gluteal skin/fat: G(∞,S/F)=1850 Pa and for cross-fibre gluteal muscle tissue: G(∞,M)=881 Pa. Instantaneous shear moduli were found at the employed ramp speed: G(0,S/F)=1920 Pa and G(0,M)=1032 Pa.  相似文献   

12.
Shoulder pain is a common clinical problem affecting most individuals in their lifetime. Despite the high prevalence of rotator cuff pathology in these individuals, the pathogenesis of rotator cuff disease remains unclear. Position and motion related mechanisms of rotator cuff disease are often proposed, but poorly understood. The purpose of this study was to determine the impact of systematically altering glenohumeral plane on subacromial proximities across arm elevation as measures of tendon compression risk. Three-dimensional models of the humerus, scapula, coracoacromial ligament, and supraspinatus were reconstructed from MRIs in 20 subjects. Glenohumeral elevation was imposed on the humeral and supraspinatus tendon models for three glenohumeral planes, which were chosen to represent flexion, scapular plane abduction, and abduction based on average values from a previous study of asymptomatic individuals. Subacromial proximity was quantified as the minimum distance between the supraspinatus tendon and coracoacromial arch (acromion and coracoacromial ligament), the surface area of the supraspinatus tendon within 2 mm proximity to the coracoacromial arch, and the volume of intersection between the supraspinatus tendon and coracoacromial arch. The lowest modeled subacromial supraspinatus compression measures occurred during flexion at lower angles of elevation. This finding was consistent across all three measures of subacromial proximity. Knowledge of this range of reduced risk may be useful to inform future studies related to patient education and ergonomic design to prevent the development of shoulder pain and dysfunction.  相似文献   

13.
Our aim was to correlate the activity of matrix metalloproteinases (MMPs) with denaturation and the turnover of collagen in normal and pathological human tendons. MMPs were extracted from ruptured supraspinatus tendons (n=10), macroscopically normal ("control") supraspinatus tendons (n=29) and normal short head of biceps brachii tendons (n=24). Enzyme activity was measured using fluorogenic substrates selective for MMP-1, MMP-3 and enzymes with gelatinolytic activity (MMP-2, MMP-9 and MMP-13). Collagen denaturation was determined by alpha-chymotrypsin digestion. Protein turnover was determined by measuring the percentage of D-aspartic acid (% D-Asp). Zymography was conducted to identity specific gelatinases. MMP-1 activity was higher in ruptured supraspinatus compared to control supraspinatus and normal biceps brachii tendons (70.9, 26.4 and 11.5 fmol/mg tendon, respectively; P<0.001). Gelatinolytic and MMP-3 activities were lower in normal biceps brachii and ruptured supraspinatus compared to control supraspinatus (gelatinase: 0.18, 0.23 and 0.82 RFU/s/mg tendon respectively; P<0.001; MMP-3: 9.0, 8.6 and 55 fmol/mg tendon, respectively; P<0.001). Most gelatinase activity was shown to be MMP-2 by zymography. Denatured collagen was increased in ruptured supraspinatus compared to control supraspinatus (20.4% and 9.9%, respectively; P<0.001). The % D-Asp content increased linearly with age in normal biceps brachii but not in control supraspinatus and was significantly lower in ruptured supraspinatus compared to age-matched control tendons (0.33 and 1.09% D-Asp, respectively; P<0.01). We conclude that the short head of biceps brachii tendons show little protein turnover, whereas control supraspinatus tendons show relatively high turnover mediated by the activity of MMP-2, MMP-3 and MMP-1. This activity is thought to represent a repair or maintenance function that may be associated with an underlying degenerative process caused by a history of repeated injury and/or mechanical strain. After tendon rupture, there was increased activity of MMP-1, reduced activity of MMP-2 and MMP-3, increased turnover and further deterioration in the quality of the collagen network. Tendon degeneration is shown to be an active, cell-mediated process that may result from a failure to regulate specific MMP activities in response to repeated injury or mechanical strain.  相似文献   

14.
This study combines non-invasive mechanical testing with finite element (FE) modelling to assess for the first time the reliability of shear wave (SW) elastography for the quantitative assessment of the in-vivo nonlinear mechanical behavior of heel-pad. The heel-pads of five volunteers were compressed using a custom-made ultrasound indentation device. Tissue deformation was assessed from B-mode ultrasound and force was measured using a load cell to calculate the force – deformation graph of the indentation test. These results were used to design subject specific FE models and to inverse engineer the tissue’s hyperelastic material coefficients and its stress – strain behavior. SW speed was measured for different levels of compression (from 0% to 50% compression). SW speed for 0% compression was used to assess the initial stiffness of heel-pad (i.e. initial shear modulus, initial Young’s modulus). Changes in SW speed with increasing compressive loading were used to quantify the tissue’s nonlinear mechanical behavior based on the theory of acoustoelasticity. Statistical analysis of results showed significant correlation between SW-based and FE-based estimations of initial stiffness, but SW underestimated initial shear modulus by 64%(±16). A linear relationship was found between the SW-based and FE-based estimations of nonlinear behavior. The results of this study indicate that SW elastography is capable of reliably assessing differences in stiffness, but the absolute values of stiffness should be used with caution. Measuring changes in SW speed for different magnitudes of compression enables the quantification of the tissue’s nonlinear behavior which can significantly enhance the diagnostic value of SW elastography.  相似文献   

15.
The interactions of small leucine-rich proteoglycans (SLRPs) with collagen fibrils, their association with water, and their role in fibrillogenesis suggests that SLRPs may play an important role in tendon mechanics. Some studies have assessed the role of SLRPs in the mechanical response of the tendon, but the relationships between sophisticated mechanics, assembly of collagen, and SLRPs have not been well characterized. Decorin content was varied in a dose dependent manner using decorin null, decorin heterozygote, and wild type mice. Quantitative measures of mechanical (tension and compression), compositional, and structural changes of the mouse patellar tendon were evaluated. Viscoelastic, tensile dynamic modulus was increased in the decorin heterozygous tendons compared to wild type. These tendons also had a significant decrease in total collagen and no structural changes compared to wild type. Decorin null tendons did not have any mechanical changes; however, a significant decrease in the average fibril diameter was found. No differences were seen between genotypes in elastic or compressive properties, and all tendons demonstrated viscoelastic mechanical dependence on strain rate and frequency. These results suggest that decorin, a member of the SLRP family, plays a role in tendon viscoelasticity that cannot be completely explained by its role in collagen fibrillogenesis. In addition, reductions in decorin do not cause large changes in indentation compressive properties, suggesting that other factors contribute to these properties. Understanding these relationships may ultimately help guide development of tissue engineered constructs or treatment modalities.  相似文献   

16.
Ultrastructural data from x-ray diffraction studies of the cornea were used to estimate the refractive indices of the collagen fibrils and extrafibrillar material of human, ox, trout, and rabbit corneas. X-ray diffraction measurements of the size and spacing of the collagen fibrils and the separation between the constituent molecules of the fibrils were taken from a previous species study. The tissue volume fractions occupied by the stromal components were estimated and their refractive indices were calculated using the Gladstone-Dale law of mixtures. For the fibrils and extrafibrillar material, the refractive indices in the human cornea were 1.411 and 1.365; for the ox 1.413 and 1.357; for the rabbit 1.416 and 1.357; and for the trout 1.418 and 1.364, respectively. An alternative estimate based on the physical properties and chemical composition of bovine cornea, accounting for interfibrillar type VI collagen and cellular water, produced similar estimates of 1.416 and 1.356 for the fibrils and extrafibrillar material, respectively.  相似文献   

17.
Extracellular matrix organization and the spatial relationship between collagen fibrils, vesicular structures, and the first deposits of mineral in the calcifying leg tendon from the domestic turkey, Meleagris gallopavo, have been investigated by high voltage electron microscopy and three-dimensional computer graphic imaging of serial thick tissue sections. The work demonstrates that the tendon extracellular matrix is a complex assembly of somewhat flexible, highly aligned collagen fibrils with different diameters and occasionally opposite directionality. Smaller collagen fibrils appear to branch from larger fibrils or to aggregate to form those of greater size. While the matrices are dominated by fibrils, space exists between adjacent packed fibrils. The three-dimensional perspective indicates that approximately 60% of the total tendon volume is extrafibrillar over the regions examined. The first observable mineral in this tissue is extrafibrillar and appears to derive from vesicles. This view of three-dimensional matrix-mineral spatial relations supports earlier two-dimensional results that mineral is initially associated with membrane-invested vesicles and is deposited between collagen fibrils, but it is distinct in showing the mineral at different depths in the matrix rather than at a single depth as deduced from two-dimensional conventional electron microscopy. These results are important in the onset and development of tendon calcification in that they suggest, first, that collagen fibrils appear to be aligned three-dimensionally such that their hole zones are in contiguous arrangement. This situation may create channels or grooves within the collagen volume to accommodate extensive mineral deposition in association with the fibrils. Second, the results indicate that there are widely dispersed sites of vesicle-mediated mineralization in the tendon matrix, that the bulk of mineralization in this tissue is collagen-mediated, and that, while vesicles may possibly exert some local influence temporally on mineralization of neighboring collagen, vesicle- and collagen-mediated mineralization arise at spatially and structurally distinct sites by independent nucleation phenomena. Such concepts are fundamental in considerations of possible mechanisms of mineralization of tendon and potentially of other normally calcifying vertebrate tissues in general.  相似文献   

18.
Rotator cuff tears frequently occur and can lead to pain and decreased shoulder function. Repair of the torn tendon back to bone is often successful in relieving pain, but failure of the repair commonly occurs. Post-operative activity level is an important treatment component that has received minimal attention for the shoulder, but may have the potential to enhance tendon to bone healing. The objective of this study was to investigate the effect of short and long durations of various activity levels on the healing supraspinatus tendon to bone insertion site. Rotator cuff tears were surgically created in Sprague-Dawley rats by detaching the supraspinatus tendon from its insertion on the humerus and these tears were immediately repaired back to the insertion site. The post-operative activity level was controlled through shoulder immobilization (IM), cage activity (CA), or moderate exercise (EX) for durations of 4 or 16 weeks. The healing tissue was evaluated utilizing biomechanical testing and a quantitative polarized light microscopy method. We found that activity level had no effect on the elastic properties (stiffness, modulus) of the insertion site at four weeks post injury and repair, and a decreased activity level had a positive effect on these properties at 16 weeks (IM>CA=EX). Furthermore, a decreased activity level had the greatest positive effect on these properties over time (IM>CA=EX). The angular deviation of the collagen, a measure of disorganization, was decreased with a decrease in activity level at 4 weeks (IM相似文献   

19.
A numerical-experimental approach has been developed to characterize heel-pad deformation at the material level. Left and right heels of 20 diabetic subjects and 20 nondiabetic subjects matched for age, gender and body mass index were indented using force-controlled ultrasound. Initial tissue thickness and deformation were measured using M-mode ultrasound; indentation forces were recorded simultaneously. An inverse finite-element analysis of the indentation protocol using axisymmetric models adjusted to reflect individual heel thickness was used to extract nonlinear material properties describing the hyperelastic behavior of each heel. Student's t-tests revealed that heel pads of diabetic subjects were not significantly different in initial thickness nor were they stiffer than those from nondiabetic subjects. Another heel-pad model with anatomically realistic surface representations of the calcaneus and soft tissue was developed to estimate peak pressure prediction errors when average rather than individualized material properties were used. Root-mean-square errors of up to 7% were calculated, indicating the importance of subject-specific modeling of the nonlinear elastic behavior of the heel pad. Indentation systems combined with the presented numerical approach can provide this information for further analysis of patient-specific foot pathologies and therapeutic footwear designs.  相似文献   

20.
Rotator cuff tears (RCTs), the most common injury of the shoulder, are often accompanied by tears in the superior glenoid labrum. We evaluated whether superior humeral head (HH) motion secondary to RCTs and loading of the long head of the biceps tendon (LHBT) are implicated in the development of this associated superior labral pathology. Additionally, we determined the efficacy of a finite element model (FEM) for predicting the mechanics of the labrum. The HH was oriented at 30° of glenohumeral abduction and neutral rotation with 50 N compressive force. Loads of 0 N or 22 N were applied to the LHBT. The HH was translated superiorly by 5 mm to simulate superior instability caused by RCTs. Superior displacement of the labrum was affected by translation of the HH (P<0.0001), position along the labrum (P<0.0001), and interaction between the location on the labrum and LHBT tension (P<0.05). The displacements predicted by the FEM were compared with mechanical tests from 6 cadaveric specimens and all were within 1 SD of the mean. A hyperelastic constitutive law for the labrum was a better predictor of labral behavior than the elastic law and insensitive to ±1 SD variations in material properties. Peak strains were observed at the glenoid–labrum interface below the LHBT attachment consistent with the common location of labral pathology. These results suggest that pathomechanics of the shoulder secondary to RCTs (e.g., superior HH translation) and LHBT loading play significant roles in the pathologic changes seen in the superior labrum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号