共查询到20条相似文献,搜索用时 15 毫秒
1.
The Fc glycosylation of therapeutic antibodies is crucial for their effector functions and their behavior in pharmacokinetics and pharmacodynamics. To monitor the Fc glycosylation in bioprocess development and characterization, high-throughput techniques for glycosylation analysis are needed. Here, we describe the development of a largely automated high-throughput glycosylation profiling method with multiplexing capillary-gel-electrophoresis (CGE) with laser induced fluorescence (LIF) detection using a DNA analyzer. After PNGaseF digestion, the released glycans were labeled with 9-aminopyrene-1,3,6-trisulfonic acid (APTS) in 96-well plates, which was followed by the simultaneous analysis of up to 48 samples. The peak assignment was conducted by HILIC-UPLC-MS/MS of the APTS-labeled glycans combined with peak fractionation and subsequent CGE-LIF analysis of the MS-characterized fractions. Quantitative data evaluation of the various IgG glycans was performed automatically using an in-house developed software solution. The excellent method accuracy and repeatability of the test system was verified by comparison with two UPLC-based methods for glycan analysis. Finally, the practical value of the developed method was demonstrated by analyzing the antibody glycosylation profiles from fermentation broths after small scale protein A purification. 相似文献
2.
Immunoglobulin G (IgG) crystallizable fragment (Fc) glycosylation is crucial for antibody effector functions, such as antibody-dependent cell-mediated cytotoxicity, and for their pharmacokinetic and pharmacodynamics behavior. To monitor the Fc-glycosylation in bioprocess development, as well as product characterization and release analytics, reliable techniques for glycosylation analysis are needed. A wide range of analytical methods has found its way into these applications. In this study, a comprehensive comparison was performed of separation-based methods for Fc-glycosylation profiling of an IgG biopharmaceutical. A therapeutic antibody reference material was analyzed 6-fold on 2 different days, and the methods were compared for precision, accuracy, throughput and other features; special emphasis was placed on the detection of sialic acid-containing glycans. Seven, non-mass spectrometric methods were compared; the methods utilized liquid chromatography-based separation of fluorescent-labeled glycans, capillary electrophoresis-based separation of fluorescent-labeled glycans, or high-performance anion exchange chromatography with pulsed amperometric detection. Hydrophilic interaction liquid chromatography-ultra high performance liquid chromatography of 2-aminobenzamide (2-AB)-labeled glycans was used as a reference method. All of the methods showed excellent precision and accuracy; some differences were observed, particularly with regard to the detection and quantitation of minor glycan species, such as sialylated glycans. 相似文献
3.
Immunoglobulin G (IgG) crystallizable fragment (Fc) glycosylation is crucial for antibody effector functions, such as antibody-dependent cell-mediated cytotoxicity, and for their pharmacokinetic and pharmacodynamics behavior. To monitor the Fc-glycosylation in bioprocess development, as well as product characterization and release analytics, reliable techniques for glycosylation analysis are needed. A wide range of analytical methods has found its way into these applications. In this study, a comprehensive comparison was performed of separation-based methods for Fc-glycosylation profiling of an IgG biopharmaceutical. A therapeutic antibody reference material was analyzed 6-fold on 2 different days, and the methods were compared for precision, accuracy, throughput and other features; special emphasis was placed on the detection of sialic acid-containing glycans. Seven, non-mass spectrometric methods were compared; the methods utilized liquid chromatography-based separation of fluorescent-labeled glycans, capillary electrophoresis-based separation of fluorescent-labeled glycans, or high-performance anion exchange chromatography with pulsed amperometric detection. Hydrophilic interaction liquid chromatography-ultra high performance liquid chromatography of 2-aminobenzamide (2-AB)-labeled glycans was used as a reference method. All of the methods showed excellent precision and accuracy; some differences were observed, particularly with regard to the detection and quantitation of minor glycan species, such as sialylated glycans. 相似文献
4.
Introduction: Glycosylation of immunoglobulin G (IgG) is important for its effector functions and was shown to be related to age, sex and disease status of an individual. Adding glycomic information to genome-wide association studies (GWAS) and large clinical trials is enabling insight into the functional relevance of changes in glycosylation, as well as molecular mechanisms behind these changes. Large-scale studies require sensitive, robust and affordable high-throughput methodologies for glycosylation analysis, which are currently available in only a limited number of laboratories. Areas covered: This review focuses on currently used high-throughput approaches for N-glycosylation analysis of IgG, as well as some recent advances in the areas of deglycosylation, trypsin digestion, labeling, purification, derivatization and automation of current workflows. Relevant literature was searched using the PubMed database. Expert commentary: Development, optimization and validation of robust, affordable and simple high-throughput glycosylation analysis methods is essential for discovery and validation of diagnostic and prognostic glycan biomarkers. Although significant advances in glycosylation analysis have been made in recent years, currently used protocols will have to be further optimized to enable subsequent analysis of glycosylation on all levels with the limited initial sample and in the minimal amount of time, which is still a challenging task. 相似文献
5.
To monitor the Fc glycosylation of therapeutic immunoglobulin G in bioprocess development, product characterization and release analytics, reliable techniques for glycosylation analysis are needed. Several analytical methods are suitable for this application. We recently presented results comparing detection methods for glycan analysis that are separation-based, but did not include mass spectrometry (MS). In the study reported here, we comprehensively compared MS-based methods for Fc glycosylation profiling of an IgG biopharmaceutical. A therapeutic antibody reference material was analyzed 6-fold on 2 different days, and the methods investigated were compared with respect to precision, accuracy, throughput and analysis time. Emphasis was put on the detection and quantitation of sialic acid-containing glycans. Eleven MS methods were compared to hydrophilic interaction liquid chromatography of 2-aminobenzamide labeled glycans with fluorescence detection, which served as a reference method and was also used in the first part of the study. The methods compared include electrospray MS of the heavy chain and Fc part after limited digestion, liquid chromatography MS of a tryptic digest, porous graphitized carbon chromatography MS of released glycans, electrospray MS of glycopeptides, as well as matrix assisted laser desorption ionization MS of glycans and glycopeptides. Most methods showed excellent precision and accuracy. Some differences were observed with regard to the detection and quantitation of low abundant glycan species like the sialylated glycans and the amount of artefacts due to in-source decay. 相似文献
6.
毛细管电泳已DNA片段分离分析的重要手段。本简述了毛细管电泳中采用无胶筛分介质分离DNA片段的机理研究,介绍了筛分介质近年的研究发展状况,依据分离介质的化学组成,分单聚物、共聚物和混聚物等3个部分进行了评述,并对其发展前景进行了展望。 相似文献
7.
Capillary electrophoresis (CE) is a convenient, fast and non-radioactive method with possibilities for automatization. To analyse single-stranded DNA molecules in a more automated way, we developed a heating device to melt double-stranded DNA fragments in the capillary during electrophoresis. In this study we used this device to obtain single-stranded DNA, necessary for the detection of point mutations in DNA using the single-strand conformation polymorphism technique. Results show that double-stranded DNA molecules can be melted on-line into single-stranded DNA molecules, although not for 100%. In an attempt to find universal electrophoretic conditions for the analysis of single-stranded DNA, we investigated the influence of several parameters on the yield of single-stranded DNA molecules and on the resolution of the single-stranded DNA peaks. We demonstrate that this heating device is a technical adjustment of CE which contributes to more automated analyses of DNA fragments. 相似文献
8.
N-linked oligosaccharides were released from human and bovine polyclonal immunoglobulin G (IgG) obtained from commercial sources and also from a monoclonal IgG(1) secreted by murine B-lymphocyte hybridoma cells (CC9C10) grown under different serum-free conditions. These conditions differed according to their steady-state dissolved oxygen concentrations. This work is based on a previous quantitative study where released glycans were characterized by fluorophore-assisted carbohydrate electrophoresis (FACE) and high-pH anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) (J. P. Kunkel, D. C. H. Jan, J. C. Jamieson, and M. Butler, 1998, J. Biotechnol. 62, 55-71). In the present article, peptide-N-glycosidase F-released glycans from different species of polyclonal IgG and murine monoclonal IgG were characterized qualitatively by high-performance liquid chromatography (HPLC) coupled to electrospray ionization mass spectrometry (ESI-MS). The glycans were also analyzed by matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). The MALDI mass spectrometer used allowed acquisition of MS and tandem MS data, which were useful in structural investigations at a more detailed level than allowed by FACE and HPAEC-PAD. Predominant N-linked structures, as determined by all techniques, were core-fucosyl asialyl biantennary chains with varying galactosylation. Minor amounts of afucosyl, bisected, and monosialyl oligosaccharides were also detected. In contrast to FACE and HPAEC-PAD, MALDI-double quadrupole/time-of-flight MS and HPLC/ESI-MS also detected low-abundance high-mannose and hybrid structures in some of the species under investigation. 相似文献
9.
Automation is essential for rapid genetic-based mutation analysis in clinical laboratory to screen a large number of DNA samples.
We propose in this report an automatic process using Beckman Coulter P/ACE™ capillary electrophoresis (CE) with laser-induced
fluorescence (LIF) system to detect a single-point mutation in the codon 12 of human K- ras gene. Polymerase chain reaction (PCR) using a fluorescently labeled reverse primer and a plain forward primer to specifically
amplify a selected 50 bp DNA fragment in human K- ras gene. The amplified DNA is placed on the sample tray of the CE system with a pre-programmed step for single-strand conformation
polymorphism (SSCP) analysis. Sample injection and denaturation processes are performed online along with separation and real-time
data analysis. The concept of automation for rapid DNA mutation analysis using CE-LIF system for SSCP is presented. 相似文献
10.
Capillary electrophoresis has advanced enormously over the last 10 yr as a tool for DNA sequencing, driven by the human and
other major genome projects and by the need for rapid electrophoresis-based DNA diagnostic tests. The common need of these
analyses is a platform providing very high throughput, high-quality data, and low process costs. These demands have led to
capillary electrophoresis machines with multiple capillaries providing highly parallel analyses, to new electrophoresis matrices,
to highly sensitive spectrofluorometers, and to brighter, spectrally distinct fluorescent dyes with which to label DNA. Capillary
devices have also been engineered onto microchip formats, on which both the amount of sample required for analysis and the
speed of analysis are increased by an order of magnitude. This review examines the advances made in capillary and chip-based
microdevices and in the different DNA-based assays developed for mutation detection and genotype analysis using capillary
electrophoresis. The automation of attendant processes such as for DNA sample preparation, PCR, and analyte purification are
also reviewed. Together, these technological developments provide the throughput demanded by the large genome-sequencing projects. 相似文献
11.
为探讨甘蔗属内不同种之间的遗传多样性,利用SSR标记与毛细管电泳技术,对来自甘蔗属3个不同种的12个材料19对引物进行检测,共检测到229个DNA多态性条带,19对引物扩增的DNA条带范围集中在100~260bp之间。12个甘蔗材料的Jaccard遗传相似度,最小0.09,最大0.65,平均为0.26。通过遗传相似性系数分析,UPGMA聚类图内12个甘蔗材料可分为两个群,三个割手密种材料分为一个亚群,甘蔗栽培品种与甘蔗热带种合为一个亚群。结果表明:热带种比割手密种具有和甘蔗栽培品种更亲近的遗传关系;SSR分子标记与毛细管技术结合,相比别的分子标记技术或电泳技术,具有更准确、简便、自动化等优点。 相似文献
12.
ABSTRACTAlthough peroxide and leachable metal-induced chemical modifications are among the most important quality attributes in bioprocess development, there is no mainstream characterization method covering all common modifications theoretically possible on therapeutic proteins that also gives consistent results quickly. Here, we describe a method for rapid and consistent global characterization of leachable metals- or peroxide-stressed immunoglobulin (Ig) G1 monoclonal antibodies (mAbs). Using two independent protease digestions, data-independent acquisition and data-dependent acquisition liquid chromatography high-resolution mass spectrometry, we monitored 55 potential chemical modifications on trastuzumab, a humanized IgG1 mAb. Processing templates including all observed peptides were developed on Skyline to consistently monitor all modifications throughout the stress conditions for both enzymatic digestions. The Global Characterization Data Processing Site, a universal automated data processing application, was created to batch process data, plot modification trends for peptides, generate sortable and downloadable modification tables, and produce Jmol code for three-dimensional structural models of the analyzed protein. In total, 53 sites on the mAb were found to be modified. Oxidation rates generally increased with the peroxide concentration, while leachable metals alone resulted in lower rates of modifications but more oxidative degradants. Multiple chemical modifications were found on IgG1 surfaces known to interact with Fc?RIII, complement protein C1q, and FcRn, potentially affecting activity. The combination of Skyline templates and the Global Characterization Data Processing Site results in a universally applicable assay allowing users to batch process numerous modifications. Applying this new method to stability studies will promote a broader and deeper understanding of stress modifications on therapeutic proteins. 相似文献
13.
We investigated a virus-neutralizing conformational epitope of the rabies virus glycoprotein (G) that is recognized by an anti-G monoclonal antibody (mAb; #1-46-12) and shared by most of the laboratory strains of the virus. To investigate the epitope structure, we isolated escape mutants from the HEP-Flury virus (wild-type; wt) after repeated passages in culture in the presence of the mAb. Immunofluorescence studies indicated that the mutants could be classified into two groups; the Group I lacked the epitope, while Group II preserved the epitope. The latter was dominant under the passage conditions, since Group I disappeared during the continuous passages. G proteins showed different electrophoretic mobilities; G protein of Group I migrated at the same rate as wt G protein, while that of Group II migrated at a slower rate, which was shown to be due to acquisition of an additional oligosaccharide side chain. Nucleotide sequencing of the G gene strongly suggested that amino acid substitutions at Thr-36 by Pro and Ser-39 by Thr of the G protein are responsible for the escape mutations of Groups I and II, respectively. The latter is a unique mutation of the rabies virus that allows the G protein to be glycosylated additionally at Asn-37, a potential glycosylation site that is not glycosylated in the parent virus, in preserving the epitope-positive conformation. These results suggest that to keep the 1-46-12 epitope structure is of greater survival advantage for the virus to escape the neutralization than to destroy it, which could be achieved by acquiring an additional oligosaccharide chain at Asn-37. 相似文献
14.
We present a novel approach of single-nucleotide polymorphism (SNP) analysis in which allele-specific oligonucleotide hybridization is followed by non-gel capillary electrophoresis (ASOH-NGCE) in conjunction with laser-induced fluorescence (LIF). This allows rapid multiplex allelotyping and allele frequency estimation. This method, based on site separation of the hybridization duplexes, retains the simplicity and specificity of ASOH and the homogeneous feature of NGCE with poly( N,N-dimethylacrylamide) (PDMA) as a sieving medium. ASOH-NGCE can be applied to multiplex SNP loci genotyping with excellent separation of hybridization mixtures. Average relative standard deviations (RSDs) were low for within-day (1.10%) and between-day (2.41%) reproducibility. Moreover, the allele frequencies in pooled DNAs were accurately determined from peak areas and equilibrium dissociation constants. Our method was highly sensitive in detecting alleles with frequency as low as 1% and in distinguishing allele frequencies differing by 1% between pools. The average value of differences between real and estimated frequencies (accuracy) was only 0.004. 相似文献
15.
DNA amplification technology has been applied to clinical diagnosis of infectious disease, genetic disorder, and cancer. After
in vitro amplification of a particular DNA region, the methods of analysis for these amplified samples play a pivotal role
in clinical diagnosis. Conventional gel electrophoresis has been routinely used in the lab for checking DNA. The whole procedure
is time consuming and requires more than 1 ng of DNA for detection. To achieve greater performance in DNA diagnosis, we demonstrated
capillary electrophoresis with laser induced fluorescence detection for analysis of amplified DNA. The analysis of DNA could
be completed within 3 min and the data is directly entered into the computer. Considering the automatic and rapid process,
we believe that this method could be routinely utilized for the clinical diagnosis of amplified DNA products. 相似文献
16.
采用毛细管电泳荧光检测技术, 对北京油鸡肌肉组织基因组进行甲基化敏感扩增片段多态性(Methylation sensitive amplified polymorphism, MSAP)检测。通过对基因组DNA用量、预扩产物稀释倍数、选择性引物浓度、Mg2+浓度、dNTPs浓度和电泳内标量等6个主要参数进行分析和优化, 建立了适合北京油鸡基因组DNA甲基化分析的MSAP毛细管电泳荧光检测技术。重复实验表明, 建立的毛细管电泳荧光标记的MSAP检测技术能够自动地、高通量地分析北京油鸡基因组的DNA甲基化状态, 也适用于其他动植物基因组的DNA甲基化研究。 相似文献
17.
For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give
relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations,
measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured
value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based
microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in
a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental
procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two
inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations
through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic
force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip
performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained
from the electropherograms showed the expected linearity. 相似文献
18.
Caspases play important roles in cell apoptosis. Measurement of the dynamics of caspase activation in tumor cells not only facilitates understanding of the molecular mechanisms of apoptosis but also contributes to the development, screening, and evaluation of anticancer drugs that target apoptotic pathways. The fluorescence resonance energy transfer (FRET) technique provides a valuable approach for defining the dynamics of apoptosis with high spatio-temporal resolution. However, FRET generally functions in the single-cell level and becomes ineffective when applied in the high throughput detection of caspase activation. In the current study, a FRET sensor was combined with capillary electrophoresis (CE) to achieve a high throughput method for cellular caspase detection. The FRET-based CE system is composed of a homemade CE system and a laser source for detecting the dynamics of caspase-3 in various cells expressing sensors of caspase-3 that have been treated with anticancer drugs, such as cell cycle-independent drug cisplatin and specific cell cycle drugs camptothecin and etoposide, as well as their combination with tumor necrosis factor (TNF). A positive correlation between the caspase-3 activation velocity and drug concentration was observed when the cells were treated with cisplatin, but cells induced by camptothecin and etoposide did not show any apparent correlation with their concentrations. Moreover, different types of cells presented distinct sensitivities under the same drug treatment, and the combination treatment of TNF and anticancer drugs significantly accelerated the caspase-3 activation process. Its high throughput capability and detection sensitivity make the FRET-based CE system a useful tool for investigating the mechanisms of anticancer drugs and anticancer drug screening. 相似文献
19.
A modified pulsed-field gel electrophoresis (PFGE) protocol was developed and applied to clinical isolates of Staphylococcus aureus and enterococci to reduce the cost of using lysostaphin. This protocol reduces the expenses of PFGE typing of S. aureus and enterococci as it removes the use of lysostaphin during the spheroplast formation from these bacteria. 相似文献
20.
Monoclonal antibodies (mAbs) are highly complex proteins that display a wide range of microheterogeneity that requires multiple analytical methods for full structure assessment and quality control. As a consequence, the characterization of mAbs on different levels is particularly product - and time - consuming. This work presents the characterization of trastuzumab sequence using sheathless capillary electrophoresis (referred as CESI) – tandem mass spectrometry (CESI-MS/MS). Using this bottom-up proteomic-like approach, CESI-MS/MS provided 100% sequence coverage for both heavy and light chain via peptide fragment fingerprinting (PFF) identification. The result was accomplished in a single shot, corresponding to the analysis of 100 fmoles of digest. The same analysis also enabled precise characterization of the post-translational hot spots of trastuzumab, used as a representative widely marketed therapeutic mAb, including the structural confirmation of the five major N-glycoforms. 相似文献
|