首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Background  ERCP-directed brush cytology is used to sample lesions of the pancreatic and biliary ducts and the ampulla of Vater. With conventional preparations, the sensitivity and specificity range from 44% to 63% and 80% to 98%, respectively, and increased N : C ratio, nuclear molding and loss of honeycombing are reliable features of malignancy. The performance and morphology of specimens prepared by ThinPrep, a liquid-based cytology technique is mostly unknown.
Methods  The laboratory information system was searched for all cases prepared by ThinPrep. Patient disease classification of benign or malignant was determined by linkage with the provincial cancer registry and was the gold standard against which sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated. True positives and negatives were reviewed to identify predictive cytomorphologic features.
Results  Between 1996 and 2001, there were 149 ThinPrep specimens; 55 (37%) were reported as positive for malignancy and 94 (63%) as negative. Disease was classified as malignant in 86 (58%) patients and benign in 63 (42%). There were 42 false negative, 11 false positive, 52 true negative, and 44 true positive cytology results. Sensitivity was 51.2% (CI; 40.2 : 62.0), specificity 82.5% (CI; 70.5 : 90.6), and PPV and NPV 80.0% (CI; 66.6 : 89) and 55.3% (CI; 44.7 : 65.5), respectively. Cell groups with crowded, enlarged, irregular nuclei and nuclear features of vesicular chromatin and large, multiple irregular nucleoli correlated with malignant disease, while monolayered sheets of uniform columnar cells, regular nuclei and a finely granular chromatin correlated with benign disease.
Conclusions  The performance of ThinPrep brushings from this anatomic site equals conventional preparations. Cytomorphologic features of malignancy are more frequent and pronounced with ThinPrep.  相似文献   

2.
Conventionally prepared endobiliary brushings are moderately (42%) sensitive and highly (98%) specific in detecting malignancy. The performance and morphological features of brushings prepared by Thinprep, a liquid-based method are mostly unknown. All brushings were retrieved from the laboratory files. Disease was classified as benign or malignant by linkage with the provincial cancer registry and sensitivity, specificity, positive (PPV) and negative predictive values (NPV) calculated. True positives and negatives were reviewed and predictive morphological features analysed by regression tree analysis. Out of 149 brushings, 55 (37%) were positive and 94 (63%) negative. Malignancy was identified in 86 (58%) and benign disease in 63 (42%) of the cases. The sensitivity was 51%, specificity 83%, PPV 80% and NPV 55%. Absolute discriminants of positive and negative brushings were not found, but nuclear cytoplasmic ratio was a useful feature. The performance of Thinprep-prepared brushings from this anatomical site was comparable with conventional preparations.  相似文献   

3.
C. Moyes  B. Dunne 《Cytopathology》2004,15(6):305-310
Definitive immediate diagnosis in breast fine needle aspiration cytology (FNAC) remains the aim for cytopathologists. We reviewed 72 consecutive equivocal (C3 and C4) aspirates with respect to 16 cytomorphological criteria. We assessed the power of each criterion at predicting either a malignant [positive predictive value (PPV)] or a benign [negative predictive value (NPV)] diagnosis by correlation with follow-up histology. Blind review led to 34% of cases being correctly definitively diagnosed. Eccentrically placed epithelial cell nuclei (PPV = 88%, sensitivity = 67%, specificity = 87%) and coarse nuclear chromatin (PPV = 81%, sensitivity = 72%, specificity = 83%) are the features that are most useful in predicting malignancy in this selected series. The presence of myoepithelial cells within epithelial groups is not a good indicator of a benign diagnosis (NPV = 24%, sensitivity = 80%, specificity = 53%).  相似文献   

4.
X. Jing, E. Wey and C. W. Michael Diagnostic value of fine needle aspirates processed by ThinPrep® for the assessment of axillary lymph node status in patients with invasive carcinoma of the breast Objective: To evaluate the utility of ThinPrep® as an optional specimen processing method for the detection of axillary lymph node metastasis of invasive breast carcinoma. Methods: A computer SNOMED search from the file at our institution between January 2003 and August 2011 retrieved a total of 209 fine needle aspiration (FNA) specimens of axillary lymph nodes prepared by ThinPrep and followed by axillary lymph node biopsy and/or dissection. Original cytological diagnoses and corresponding histological diagnoses were documented. Using the histological diagnoses as the gold standard, the diagnostic parameters including sensitivity, specificity, positive (PPV) and negative predictive values (NPV) and diagnostic accuracy were calculated. Both cytology and histology slides from cyto‐histologically discrepant cases were reviewed. Results: Out of a total of 209 specimens, 193 (92%) had adequate diagnostic material while the remaining 16 specimens (8%) were inadequate for cytological assessment. The diagnostic specimens included 168 invasive ductal carcinomas (IDC), 15 invasive lobular carcinomas (ILC) and 10 mixed carcinomas (IDC and ILC). Excluding 19 cases with malignant cells on FNA in which no residual tumour was found in fibrotic lymph nodes after neoadjuvant therapy (cytology and histology confirmed on review) ThinPrep detected nodal metastasis with an overall sensitivity of 77.5%, specificity of 100%, PPV of 100% and NPV of 53.7%. Diagnostic accuracy was 82.2%. There was no difference in Bloom–Richardson grade or the number or size of metastases between tumours with true‐positive and false‐negative cytology. Sampling error was the sole factor contributing to cyto‐histological discrepancy. Conclusions: ThinPrep is a good alternative to the conventional smear for cytological assessment of axillary lymph node status in patients with invasive breast carcinoma, particularly when specimens are collected at remote sites or when cytologists are not available for assistance during FNA.  相似文献   

5.
OBJECTIVE: To determine efficacy and utility of NMP-22 in follow-up of bladder urothelial carcinoma (UC) and compare NMP-22 as a single evaluating test vs combination with cytology. STUDY DESIGN: Ninety-four consecutive urine cytology samples of bladder UC were identified. Patients received follow-up urine cytology, NMP-22 testing and cystoscopy with surgical biopsy. RESULTS: NMP-22 specificity was 100%, sensitivity 45%, positive predictive value (PPV) 100% and negative predictive value (NPV) 87%. NMP-22 showed lower sensitivity for high-grade lesions and higher for low-grade lesions. Cytologic diagnosis had a high inconclusive rate; when regarded as positive, it resulted in 75% sensitivity, 58% specificity, 33% PPV and 89% NPV. NMP-22 correctly classified 60% of false negative cases diagnosed by cytology with low-grade UC and clarified 27 inconclusive cytologic diagnoses. NMP-22 misclassified 9 cases as false negative, all with high-grade UC; all were correctly identified on cytology as true positive. Combined interpretation showed 90% sensitivity, 92% specificity, 75% PPV and 98% NPV. CONCLUSION: NMP-22 complements cytology by its higher sensitivity for low-grade lesions; its values are not affected by bacillus Calmette Guérin therapy changes, which are limiting in cytology. Combined interpretation of NMP-22 and cytology shows promise as an effective, noninvasive method for surveillance of UC.  相似文献   

6.
OBJECTIVE: To evaluate the usefulness of reclassifying "atypical" diagnoses in reporting biliary cytology using strict morphologic criteria. STUDY DESIGN: Cytologic specimens from 139 patients (direct, alcohol-fixed smears or cytocentrifuge preparations) were evaluated. Diagnoses were benign (70), atypical (36) and malignant (33). Using strict criteria--major (nuclear contour, chromatin pattern) and minor (polarity, cell types, nuclear size, nuclear grooves, nucleoli, mitosis, nuclear/cytoplasmic [N/C] ratio)--atypical cases were reevaluated and reclassified. Follow-up (F/U) was available on all cases. RESULTS: Atypical cases, (36) were reclassified as malignant (26), atypical favor benign (2)/reactive (3) and atypical, not otherwise specified (NOS) (5). Cases reclassified as malignant showed irregular nuclear contours, chromatin irregularities and rare mitosis. Nuclear enlargement, nucleoli and cellularity varied widely in all groups. N/C ratio was increased in most reclassified malignant cases. All 26 malignant reclassifications correlated with F/U of malignancy. Benign and reactive cases (5) were negative for malignancy on F/U (4), and in 1 case a metastatic carcinoma involving the biliary tree was found. In the 5 atypical (NOS) cases, F/U showed malignancy (3) and pancreatitis (2). Cytocentrifuge preparations made in our laboratory were of superior quality when compared to other methods of cell preparation. CONCLUSION: Irregularities in nuclear membrane and abnormal chromatin pattern were the most consistently useful features correlating with malignancy. The sensitivity and specificity of biliary brush cytology can be enhanced by using strict cytomorphologic criteria and proper collection and fixation, all of which decrease atypical diagnoses.  相似文献   

7.
OBJECTIVES: To characterize the cytopathologic outcome of lesions detected on positron emission tomography (PET) scan. STUDY DESIGN: Cases with fine needle aspiration (FNA) performed because of a PET-positive lesion over an 18-month period were reviewed. Correlation with the standard uptake value (SUV) (using 2.5 as a cutoff value) was carried out. RESULTS: A total of 112 FNAs were found, of which 83 had adequate tissue for evaluation and available corresponding SUVs to be included in the final study. Fisher's exact test was carried out for correlation between FNA diagnosis and SUV Sixty-one (73.5%) lesions had an SUV > or = 2.5, 53 (87%) ofwhich were malignant and 8 (13%) benign on cytology. Twenty-two (26.5%) lesions had an SUV < 2.5, of which 12 (54.5%) showed benign and 10 (45.5%) showed malignant cytology. The overall sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy of SUV were 84%, 60%, 87%, 56% and 78%, respectively. CONCLUSION: Our data show that FNA procedures performed for PET-positive lesions have high PPV, but low NPV. Therefore interpretation of PET SUV values < 2.5 as benign should be made with extreme caution.  相似文献   

8.
目的:评估和比较高分辨率计算机断层成像(high resolution computer tomography,HRCT)与磁共振成像(magnetic resonance imaging,MRI)对中耳胆脂瘤的诊断价值。方法:回顾性分析临床初步诊断为中耳胆脂瘤患者55人(63耳)在术前5天内进行的16排HRCT和1.5T MRI诊断结果,以病理诊断为基础对HRCT和MRI的诊断结果进行对比研究,统计分析HRCT和MRI的灵敏度、特异度、阳性预期值、阴性预期值,以及Kappa检验两者之间的内在观察一致性。结果:63耳中,病理确诊为中耳胆脂瘤40耳。HRCT正确诊断30例,假阳性11例,假阴性10例,灵敏度、特异度、阳性预期值以及阴性预期值分别为75%、52.17%、73.17%、54.55%。MRI正确诊断37例,假阳性和假阴性各为3例,灵敏度、特异度、阳性预期值以及阴性预期值分别为92.5%、86.96%、75%和86.96%。HRCT与MRI诊断结果之间的内在观察一致性Kappa=0.274(P0.05)。剔除既往有手术史的10耳,只针对无手术史的53耳,HRCT与MRI诊断结果之间的内在观察一致性增高,吻合度一般,Kappa=0.462(P0.05)。结论:MRI的总体阳性检出率高于HRCT,尤其是对中耳胆脂瘤手术后复发的诊断;HRCT与MRI两者相结合对于中耳胆脂瘤的明确诊断具有互补作用。  相似文献   

9.
R. Dina 《Cytopathology》2003,14(Z1):16-16
Aim To detect major pitafalls in thyroid FNA and to confirm its in a clinical sensitivity and specificity. Methods A total of 9251 fine needle aspirations biopsy carried out at Bellaria Hospital in Bologna from 1991 to 2000 by a pathologist in the FNA Clinic or by a clinician under ultrasonic guidance using a small needle (25–27 G); at least two passes have been made for each nodule. The specimen was considered satisfactory if at least five groups of follicular cells with at least 10 cells each, were seen. The cytological results were tiered in a four categories classification: inadequate, negative, suspicious and positive. Cyto‐histological correlations were available in 212 cases: 127 benign lesions and 85 malignant lesions. An analysis of false positive cases and false negative cases was performed and discordant case reviewed according to the flowing criteria: architecture, cellularity, colloid, pseudoinclusions, nuclear groovings, chromatin pattern, nuclear membrane, cytoplasm, naked nuclei and lymphocytes. Results Diagnostic distribution in 9251 FNAs from the thyroid: 88.6% negatives, 2.8 suspicious, 2.4% positives and 6.2% inadequates. Specificity was 85.8% and sensitivity was 78.8%. Among the 18 false negative cases eight were papillary microcarcinomas, four papillary carcinomas, five follicular carcinoma and one a Hurtle cell carcinoma. Four false positive cases were found: three reported as papillary carcinomas and one as carcinoma NOS. Review of false positives showed that in three cases the colloid was fluid, in three cases nuclear grooving was rare or absent, in two cases degenerative vacuoles at MGG were interpreted as nuclear inclusions and in three cases benign naked nuclei were present in the background. Review of false negatives confirmed lack of malignant features in 13 (eight papillary microcarcinomas and five follicular carcinomas), five were interpretation errors (three papillary carcinomas, one follicular, one Hurtle cell). Conclusion FNAC of the thyroid is a sensitive and specific method of assessment for thyroid nodules but false negative and false positive cases do occur. Use of all and only few criteria enhances diagnostic accuracy.  相似文献   

10.
OBJECTIVE: To examine the diagnostic value (sensitivity and specificity of the ThinPrep Pap test in the detection of endometrial cancer and assess the morphologic features of endometrial cancer in ThinPrep tests. STUDY DESIGN: In a retrospective, case-controlled study, we identified 60 Pap slides performed within 12 months of the tissue diagnosis of endometrial carcinoma and 56 comparison slides from patients without known carcinoma. The slides were blindly reviewed by the authors without knowledge of the surgical diagnosis. An independent diagnosis was given for the tests based on 14 diagnostic criteria from the 2001 Bethesda System and 6 additional criteria proposed by the authors. RESULTS: The sensitivity of detecting endometrial carcinoma was 88.3% (95% CI 77.8-94.2%) and specificity was 87.5% (95% CI 76.4-93.8%). The positive likelihood ratio was 7.067 (95% CI 3.513-14.217) and negative likelihood ratio was 0.133 (95% CI 0.066-0.269). Enlarged nuclei and the presence of nucleoli in endometrial cells were the most reliable indicators of endometrial cancer or atypical endometrial cells. CONCLUSION: The ThinPrep Pap test has high sensitivity and specificity in detecting or suggesting the presence of endometrial cancer. Certain cytomorphologic features are helpful in distinguishing benign and malignant endometrial lesions.  相似文献   

11.
Choi YD  Choi YH  Lee JH  Nam JH  Juhng SW  Choi C 《Acta cytologica》2004,48(6):801-806
OBJECTIVE: To evaluate the accuracy of fine needle aspiration (FNA) cytology of the breast and to ascertain its usefulness. STUDY DESIGN: The authors reviewed 1,297 cases of FNA cytology of the breast which were performed at Chonnam National University Hospital from 1999 to 2002. Cytologic diagnoses were compared with histologic diagnoses in 457 cases that underwent both cytologic and histologic examination. RESULTS: Of 1,297 cases, 1,201 (92.6%) were satisfactory and 96 (7.4%) unsatisfactory. Subsequent histologic examination was performed on 291 cases (29.7%) out of 981 "benign" lesions, 28 (73.7%) of 38 "suspicious," 124 (68.1%) of 182 "malignant" and 14 (14.6%) of 96 "unsatisfactory." FNA cytology revealed 77.7% sensitivity, 99.2% specificity, 98.4% positive predictive value and 88.0% negative predictive value. Diagnostic accuracy was 91.1%. Of the 291 benign cases on cytology, 35 cases were malignancy on histology. Of the 124 cases reported as malignant, 2 were benign. Interpretive error was the leading cause of false positive diagnoses. CONCLUSION: Although FNA cytology is a useful diagnostic procedure for the evaluation of breast lesions, it should be combined with other diagnostic modalities, such as physical examination, ultrasonography and mammography.  相似文献   

12.
Introduction Positive predictive value (PPV), measuring the percentage of moderate dyskaryosis or worse confirmed as CIN2 or worse, is used as a measure of accuracy in cervical screening. However, it relates more to specificity than sensitivity because the denominator includes false positives rather than false negatives. Low values reflect over‐reporting of high‐grade dyskaryosis but high values may reflect under‐reporting. Sensitivity is impossible to measure from correlation of cytology with outcome because women with negative cytology are rarely referred for colposcopy. Rates of CIN3 resulting from referrals for low‐grade cytology may be used as a surrogate for sensitivity, as high values may reflect under‐reporting (ref). Study design Outcome of colposcopy referrals was monitored during a period of 4 years, using a fail‐safe database. Results PPV at Guy's & St Thomas rose from 54% in 1998/1999 to 69% in 2001/2002. The former was below the NHSCSP recommended range. During the same period of time CIN1 rates for moderate dyskaryosis fell from 37% to 24%, reflecting the main source of discrepancy. While specificity increased (as reflected by increasing PPV) sensitivity remained constant in that CIN3 rates for mild dyskaryosis and borderline remained below 6%: average rates in England have fallen over the last 3 years and were 7.4% in 2000/2001 (ref). CIN2 rates for mild dyskaryosis also remained constant at 11% to 12%. Conclusion Correlation of biopsy results with high‐ and low‐grade cytological abnormalities is a useful method of monitoring accuracy of cytology reporting, and can be used to measure over‐ and under‐reporting as surrogates for specificity and sensitivity.  相似文献   

13.
Introduction Fine needle aspiration cytology is regarded as the gold standard investigation in diagnosis of thyroid swellings. Published data suggest an overall accuracy rate of 75% 1 in the detection of thyroid malignancy. The aim of this study was to determine the accuracy of FNA cytology in detection of thyroid malignancy in our surgical unit. Methods Between 1989–2002, 144 patients who underwent thyroid resection by single consultant surgeon and who had pre‐operative FNA were enrolled in this retrospective study. The pre‐operative FNA results were compared with definitive histological diagnosis following thyroid resection. Fine needle aspiration cytology was performed using aspirate and non‐aspirate techniques on each thyroid swelling. The cytological sample was assessed by a single cytopathologist and was classified as inadequate, non‐neoplastic, neoplastic, suspicious or indeterminate. The histology was classified as non‐neoplastic (benign) and neoplastic (malignant). Results Fine needle aspiration cytology analysis revealed 94 (13.88%) non‐neoplastic, six (65.27%) neoplastic and 20 (4.16%) suspicious aspirates. Twenty (13.88%) samples were inadequate and four (2.77%) samples were indeterminate. Histological analysis showed 118 (81.94%) benign, 26 (18.05%) malignant specimens. Fine needle aspiration cytology had a sensitivity, specificity and accuracy rate of 52.6%, 86.6% and 79.1%, respectively for diagnosing thyroid malignancy. Conclusion The results are comparable with the current published data and demonstrate that FNA cytology in our hands is accurate investigation for pre‐operative diagnosis for the detection of thyroid malignancy.  相似文献   

14.
Sng KK  Nga ME  Tan SY  Walker T 《Acta cytologica》2007,51(5):782-787
OBJECTIVE: To evaluate the smear quality and diagnostic accuracy of ThinPrep processing in comparison to conventional Cytospin technique for urinary cytology. STUDY DESIGN: ThinPrep and Cytospin techniques were retrospectively evaluated by 2 observers in a double-blinded, randomized fashion. Each quality parameter was scored using a semi-quantitative score of 1-3. Diagnostic accuracy indices were calculated with biopsy histology as the gold standard. RESULTS: Quality of cellular distribution and cell preservation were better with Cytospin preparations, whereas ThinPrep smears were superior in terms of stain distribution and cleaner slide background. However, the only significant differences observed were in cellular distribution and a clean background (p < 0.05). Sensitivity and positive and negative predictive values were higher with Cytospin than the ThinPrep technique (90.0%, 94.7% and 71.4% vs. 80.0%, 94.1% and 55.6%, respectively). Conversely, the specificity of both techniques was comparable. CONCLUSION: The Cytospin smears were of better quality than those prepared by the ThinPrep technique. Although both techniques resulted in similar diagnostic accuracies in negative cases, the ThinPrep preparations were not found to be superior to Cytospin smears in diagnosing positive urinary cytology.  相似文献   

15.
OBJECTIVE: Common bile duct (CBD) brushings have been recognized as a technique of moderate sensitivity and high specificity in identifying carcinoma of the ampulla and pancreatico-biliary regions. This study evaluated the increase in sensitivity of this technique using the ThinPrep technique of specimen preparation when compared with conventional cytology smears. METHODS: A total of 113 bile duct brushings were included in the study (38 conventional smears and 75 slides prepared using the ThinPrep technique). All slides were reviewed by one cytologist. Five categories of reporting were used: inadequate, negative, atypia, suspicious and malignant. RESULTS: The inadequate category of reporting disappeared in the ThinPrep group with improved specimen fixation and preparation and hence reduced artefact. Sensitivity of diagnosis of malignancy increased from 39% in conventional smears to 53% in the ThinPrep group. Specificity, positive and negative predictive values and accuracy were 100%, 100%, 60% and 68% for conventional smears and were 100%, 100%, 60% and 72%, respectively, for ThinPrep specimens. CONCLUSIONS: ThinPrep technique was associated with increased sensitivity of diagnosis, in part due to improved specimen fixation and reduced artefact. Cytology of bile duct brushings is an important diagnostic tool for sites from which it can be difficult to obtain a histology biopsy. It may therefore provide the only opportunity for tissue diagnosis of carcinoma from these sites, hence the importance of optimizing sensitivity.  相似文献   

16.
Abstract

The development of oral squamous cell carcinoma (OSCC) occasionally follows the neoplastic progression of other premalignant lesions. Although biopsy is the definitive diagnostic method, liquid-based cytology is an adequate method for screening suspicious lesions. We compared liquid-based cytology to histology for diagnosis of OSCC in patients with oral lesions that raised clinical suspicion of malignancy. Our sample consisted of 48 patients. Cytological samples were obtained by scraping the lesion superficially using Cytobrush®. We conducted cytological and histopathological evaluation of all preparations. We estimated sensitivity and specificity levels as well as positive and negative predictive values. The degree of inter-observer agreement for both methods was assessed using the kappa index. Twenty-eight (58.3%) of the cases finally were diagnosed with OSCC and 20 (41.7%) were determined to be premalignant lesions. We observed eight false negatives and no false positives; OSCC prevalence was 56.5%. The values for diagnostic indices were: sensitivity, 69% (CI 95%, prevalence 51.87); specificity, 100%; positive predictive value, 100%; negative predictive value, 71% (CI 95% 54.82). A kappa index of 0.622 (CI 95% 0.93, 0.39) was observed.  相似文献   

17.
The aim of this study is to evaluate the efficacy of qualitative analysis of contrast-enhanced ultrasound (CEUS) in discrimination of adnexal masses which were undetermined by conventional ultrasound (US). A total of 120 patients underwent transabdominal CEUS. The initial enhancement time and intensity compared with the uterine myometrium, contrast agent distribution patterns and dynamic changes of enhancement were assessed. The sensitivity (Sen), specificity (Spe), positive predictive value (PPV), negative predictive value (NPV), accuracy (ACC) and Youden’s index were calculated for contrast variables. The gold standard was the histological diagnosis. There were 48 malignant tumors and 72 benign tumors. The enhancement features of malignant masses were different from benign ones. Earlier or simultaneous enhancement with inhomogeneous enhancement yielded the highest capability in differential diagnosis, and Sen, Spe, PPV, NPV, ACC, Youden’s index was 89.6%, 97.2%, 93.2%, 95.6%, 93.3%, and 0.88, respectively. The qualitative evaluation of CEUS is useful in the differential diagnosis of adnexal masses where conventional US is indeterminate.  相似文献   

18.
Objectives:  This prospective study was undertaken to evaluate nuclear matrix protein (NMP22) compared to urine cytology in the detection of bladder cancer and also to determine whether indexing suspicious cytology to NMP22 could enhance the clinical utility of cytology.
Methods:  Cytological findings of voided urine collected prior to a cystoscopic biopsy were correlated with urine NMP22 assay in 46 patients attending the urology clinic in Mubarak Al-Kabeer Hospital. The patients were clinically categorized into newly diagnosed cases of transitional cell carcinoma (TCC), recurrent TCC, TCC in remission and controls.
Results:  Using histological diagnosis as the gold standard the sensitivity and specificity of NMP22 were 78% and 43% respectively and of cases with malignant urine cytology were 30% and 87% respectively. If suspicious and malignant cytology were combined as positive results the sensitivity increased significantly to 87% while the specificity decreased but not significantly to 74%. Suspicious or malignant cytology enhanced by positive NMP22 gave a sensitivity of 70% and specificity of 87% neither of which was significantly different from cytology alone. There were three false positive cases on cytology and 13 false positive cases on NMP22 assay. There were three false negative cytology and five false negative NMP22 cases but only one was false negative for both, resulting in a high sensitivity (96%) but low specificity (30%) if either positive NMP22 or malignant or suspicious cytology was taken as a positive result.
Conclusion:  Combining NMP22 with malignant or suspicious cytological result improved sensitivity for the detection of bladder cancer but with a major decrease in specificity, suggesting a potential role in screening rather than diagnosis.  相似文献   

19.
Wood MD  Huang Y  Bibbo M 《Acta cytologica》2005,49(3):291-296
OBJECTIVE: To improve recognition of thyroid carcinoma in rapid consultation on Diff-Quik-stained (Fisher Diagnostics, Middletown, Virginia, USA.) fine-needle aspiration (FNA) and rapid hematoxylin-eosin (H-E)-stained intraoperative scrape preparation (ISP) specimens by assessing 3 variables (anisokaryosis, nuclear overlap [NO] and scant/absent colloid) in cases of cellular follicular lesions (CFL), an indeterminate diagnostic category. STUDY DESIGN: Thirty-seven FNAs and 28 ISPs diagnosed as CFL, with histologic follow-up, were evaluated in blinded fashion by 3 cytopathologists assessing the 3 variables. RESULTS: Over 90% of the malignant cases showed NO in both FNA and ISP, while only 22% of the benign cases did; positive and negative predictive values (PPV and NPV) were 82% and 100%. All malignant cases showed significant anisokaryosis in both FNA and ISP in contrast to 24% of benign cases; PPV and NPV were 74% and 100%. Scant/absent colloid was seen in 87% and 39% of malignancies in FNA and ISP, respectively, as compared to 55% and 20% of the benign cases. PPV and NPV were 52% and 83% in FNA and 63% and 60% in ISP, respectively. CONCLUSION: Application of these variables improves recognition of thyroid carcinoma, particularly in fine needle aspirates, while additional material may be requested. With ISP, their absence supports recommending against further surgery. Together, optimal surgical planning and outcome may be obtained.  相似文献   

20.
《Endocrine practice》2018,24(5):453-459
Objective: Circulating tumor DNA (ctDNA), a subset of cell-free DNA (cfDNA), is a potential biomarker for thyroid cancer. We determined the performance of a ctDNA panel for detecting thyroid malignancy in patients with thyroid nodules.Methods: Sixty-six patients with thyroid nodules without a prior history of cancer enrolled in a prospective, 1-year study in which blood was drawn for ctDNA analysis prior to undergoing fine-needle aspiration biopsy (FNAB) of thyroid nodules. The ctDNA panel consisted of 96-mutations in 9 cancer driver genes. The primary outcome measures were the sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of our ctDNA panel for the diagnosis of thyroid malignancy as determined by pathologic and/or molecular tissue examination.Results: Results from 10 subjects could not be determined due to inadequate volume or technical issues. The final classifications of the thyroid nodules were 13 malignant and 43 benign lesions. A KRAS G12V mutation was detected in the plasma of 1 patient with stage IVA papillary carcinoma whose tissue contained the same mutation. Two of the 43 patients with benign lesions also had ctDNA detected, giving a sensitivity of 7.7%, specificity of 95.35%, PPV of 33.33%, and NPV of 77.35%. There were no significant differences between benign or malignant lesions in cfDNA levels.Conclusion: Neither cfDNA measurements nor our panel of ctDNA mutations are sensitive or specific enough to provide valuable information over FNAB. An expanded panel and the inclusion of proteomics may improve sensitivity and specificity for thyroid cancer detection.Abbreviations: cfDNA = cell-free DNA; ctDNA = circulating tumor DNA; FNAB = fine-needle aspiration biopsy; NIFTP = noninvasive follicular thyroid neoplasm with papillary-like nuclear features  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号