首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract: D2 is a glycoprotein existing in both membrane-bound and soluble forms. Employing a specific rabbit antibody against purified human brain D2, we developed an enzyme-linked immunosorbent assay (ELISA) for the quantification of D2 and applied it to amniotic fluids from 87 normal and 36 pathological pregnancies. With a cut-off point of 150 ng D2/ml, no false positive D2 values were obtained in any of the amniotic fluids from normal fetuses, although the alpha-fetoprotein concentrations were slightly increased in 13 cases. No false negative D2 values were found in any of the 18 investigated amniotic fluids from fetuses with anencephaly. Of 8 amniotic fluids from fetuses with spina bifida, 2 false negative D2 values were found. No false negative alphafetoprotein values were found in any of the cases with neural tube defects in this study. In 10 amniotic fluids from fetuses with other malformations, 5 samples showed raised D2 concentrations. The D2 level in sera from 10 women carrying normal fetuses and 16 women carrying malformed fetuses was also determined, but no statistically significant difference in D2 level was found in the pathological sera when compared with normal sera. It was concluded that the determination of D2 concentrations in amniotic fluid by means of the D2-ELISA may be used as an additional test in the screening of fetal malformations in early pregnancy.  相似文献   

2.
Human alpha-1-proteinase inhibitor(1) (alpha(1)-PI) is the most abundant serine protease inhibitor in plasma. Its major function is inhibition of neutrophil elastase in lungs. alpha(1)-PI deficiency may result in severe, ultimately fatal emphysema. Three plasma-derived (pd-) alpha(1)-PI products are licensed in the US for replacement therapy of deficient patients. The recombinant versions (r-alpha(1)-PI), proposed as alternatives to pd-alpha(1)-PI products, have been under intensive investigation. For accurate determination of alpha(1)-PI from different sources and in various forms, there is an obvious need for reliable standardized assays for alpha(1)-PI quantification and potency measurements. As a part of our multi-step research focused on alpha(1)-PI structure-function investigation, we have established a simple and reproducible double-sandwich ELISA based on commercially available polyclonal antibodies. The developed ELISA allows the quantification of both pd-alpha(1)-PI and r-alpha(1)-PI in various complex matrices. A validation of the ELISA was performed with the working range of the assay (3.1-50 ng/ml) established on the bases of the following parameters: linearity (3-100 ng/ml, r(2)=0.995); accuracy (87.3-114.6% recovery); intra-assay precision (%CV, 2.8%); inter-assay plate-to-plate precision (3.9% per day and 4.1% day-to-day); detection limit (1.10 ng/ml); and quantification limit (3.34 ng/ml). The analytical performance of the alpha(1)-PI ELISA indicates that this assay can be used for monitoring concentration levels of alpha(1)-PI in multi-component biological matrices, based on the following: (a) quantification of r-alpha(1)-PI in various fermentation mixtures (E. coli and A. niger); (b) investigation of alpha(1)-PI enzymatically digested in the conditions of harsh fungal proteolysis; (c) evaluation of thermally polymerized alpha(1)-PI; (d) quantification of alpha(1)-PI in human serum; and (e) comparative quantification of alpha(1)-PI in commercially available products.  相似文献   

3.
The development of the HIV protease inhibitor saquinavir (Ro 31-8959) required a range of analytical methods for its measurement in biological fluids. This paper describes the development of isocratic, reverse-phase HPLC/UV methods for the routine measurement of plasma levels of the drug together with a more sensitive radioimmunoassay. The performance of the two assays is compared with that of an HPLC/MS/MS method previously published and has been shown to be satisfactory, with coefficients of variation of calibration standards and quality control samples within the usual outside limits of +/- 15%. The HPLC/UV method can be routinely applied for concentrations down to 10-20 ng/ml and a lower limit of quantification of 1 ng/ml from 1 ml of human plasma is possible. The radioimmunoassay was developed for the specific measurement of saquinavir concentrations in human, HIV-positive plasma samples and has a lower limit of quantification of 0.5-1.0 ng/ml. Some preliminary findings suggested that it might not be specific in rat plasma and no attempts have been made to quantify any nonclinical samples with this technique. If still greater sensitivity is required, recourse can be made to the HPLC/MS/MS assay.  相似文献   

4.
ELISA for soluble fibrin (SF) quantification has been elaborated on the basis of our fibrin-specific monoclonal antibodies (mAb). Epitope for these mAb is localized in fibrin fragment Bbeta118-134. The method was used on the blood plasma of healthy pregnant women (control group) and pregnant women with the risk of fetal loss (RFL). The increased mean values of SF concentrations were observed at pregnancy with RFL as compared to the normal pregnancy at the terms from 4 to 24 weeks (17.87 +/- 3.15 mkg/ml and 9.03 +/- 1.58 mkg/ml accordingly, p < 0.05). A weak negative correlation between SF concentration and pregnancy term was found at RFL (r = -0.201, n=35), while there was no correlation between these variables in control group (r = 0.004, n=28). The mean values of SF concentration estimated by semiquantitative test (by phosphates salting out of SF) were also higher at the pregnancy with RFL as compared to the normal pregnancy. However, the absolute values of SF concentrations determined by salting out method were essentially higher than in the case of ELISA. Immunoblot analysis with mAb 2d-2a (epitope for which in fibrin molecule encompasses peptide bond Bbeta14-15), showed that the main molecular component of SF at normal pregnancy and RFL was oligomeric fibrin desAA with possible incorporation of fibrinogen and/or fibrin desA which was not stabilized by factor XIIIa. D-dimer concentrations determined in blood plasma samples of pregnant women by ELISA varied in the range of 1-224 ng/ml at the pregnancy period from 4 to 37 weeks. There was positive correlation between D-dimer concentration and pregnancy term both at normal pregnancy and pregnancy with RFL (r = 0.765, n=33 and r = 0.712, n=44 correspondingly). The mean values of D-dimer concentration at various terms of normal pregnancy and pregnancy with RFL did not vary considerably. Thus SF but not D-dimer quantification may give useful diagnostic information at the pregnancy with RFL.  相似文献   

5.
Highly sensitive immunoassays have been used to quantitate aflatoxins (AF) and N-nitrosamines (NNO) in human body fluids and tissues, respectively. This approach was taken in order to quantitate environmental exposure to these agents at an individual level to facilitate the investigation of their role in the etiology of human cancer. In order to analyse AF in human urine, an immunopurification step has been developed by using AF-specific antibody bound to AH-Sepharose 4B gel in a small (4-ml gel volume) affinity column prior to enzyme-linked immunosorbent assay (ELISA). The ELISA can be used to quantitate aflatoxin B1 (AFB1) over the range 0.01 ng/ml to 10 ng/ml and the assay system has been validated by using human urine samples spiked with AFB1 over this concentration range. In addition, 29 urine samples from the Philippines have been analysed and found to contain a range of levels from zero to 4.25 ng/ml AFB1 equivalent with a mean of 0.875 ng/ml. This compared with a mean of 0.066 ng/ml AFB1 equivalent in samples from France. Radioimmunoassay of O6-methyldeoxyguanosine (O6-medG) has been performed on human oesophageal and cardiac stomach mucosal DNA from tissue samples obtained during surgery in Linxian County, People's Republic of China, an area of high risk for both oesophageal and stomach cancer. Using the methodology described and having 1 mg of hydrolyzed DNA allows the detection of approximately 25 fmol O6medG per mg DNA.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
Size heterogeneity of epidermal growth factor in human body fluids   总被引:2,自引:0,他引:2  
We measured the concentration of immunoreactive (IR) hEGF in various body fluids by radioimmunoassay (RIA) and evaluated its size heterogeneity by size exclusion high performance liquid chromatography combined with RIA or with time-resolved immunoflurometric assay (TR-IFMA). Mean concentration was 80 ng/ml in urine, 65 ng/ml in milk, 50 ng/ml in seminal plasma, 25 ng/ml in armpit sweat, 1 ng/ml in breast sweat, 0.3 ng/ml in third-trimester amniotic fluid, 3 ng/ml in saliva, 1.5 ng/ml in tears and 0.3 ng/ml in gastric juice.

All the fluids except armpit sweat and gastric juice contained two to five molecular sizes of IR-hEGF. As well as the 6200-dalton (6.2kDa) hEGF we found at least four other different molecular sizes with approximate weights of 300, 150, 70 and 20kDa. The authentic 6.2kDa form made up >90% of the total IR-hEGF in all except the amniotic fluid where its proportion was 71%, and the seminal plasma where the proportion could not be determined.  相似文献   


7.
Epidermal growth factor-like proteins in breast fluid and human milk   总被引:4,自引:0,他引:4  
J M Connolly  D P Rose 《Life sciences》1988,42(18):1751-1756
Epidermal growth factor (EGF), and the transforming growth factor-alpha (TGF-alpha) family of proteins, which also bind to the EGF receptor, have been associated with human breast cancer. The total EGF-like proteins were determined by a radioreceptor assay, and TGF-alpha by radioimmunoassay, in human milk and breast fluid samples. The breast fluids were collected by nipple aspiration from healthy premenopausal women. Both the 24 milks and 18 breast fluids assayed contained EGF-like proteins, at concentrations ranging from 32-600 ng/ml (median, 140 ng/ml), and 62-654 ng/ml (median, 205 ng/ml) respectively. Immunoreactive TGF-alpha proteins were detected at higher levels in 21 breast fluids (range, 0-50.0; median 5.1 ng/ml) than in 24 milk samples (range, 0-8.4; median, 0.8 ng/ml).  相似文献   

8.
Serum progesterone and testosterone concentrations were measured during different stages of oestrous and pregnancy in paired and unpaired female common voles (Microtus arvalis). Hormone concentrations were measured by ELISA, and cycle stages were determined by vaginal smears. Paired females usually had serum progesterone concentrations of more than 10 ng/ml in the oestrous cycle. A significant maximum was detected in prooestrous (51.70 +/- 7.84 ng/ml, mean +/- S.D.). Serum progesterone concentrations increased from about 40 ng/ml at the beginning of pregnancy to about 70 ng/ml on days 15 and 16. The last 2 days before parturition (days 19 and 20) were characterised by a decrease of progesterone concentrations to ca. 30 ng/ml. The maximum concentration of testosterone was found in prooestrous (1.58 +/- 0.31 ng/ml). Concentrations during pregnancy varied between 1.5 and 2.1 ng/ml. In two of three cases unpaired females exhibited progesterone values below 10 ng/ml, but with varying vaginal smear patterns. The combination of progesterone concentrations and vaginal smear patterns was found to be regular in only 23.8% of the cases. The most frequent cycle stage found was the oestrous (44.2%). Mean concentrations of progesterone (10.43 +/- 13.81 ng/ml) and testosterone (0.85 +/- 1.11 ng/ml) in unpaired females were significantly lower than in paired females, thereby denoting reproductive inactivity in the former. The study presents basic data for several parameters of the reproductive biology in the common vole and confirms the importance of combining hormone assays and vaginal smear monitoring in reproductive research.  相似文献   

9.
Despite the availability of many assays to measure concentrations of tumour necrosis factor alpha (TNF-alpha) in body fluids, these assays often lack specificity or sensitivity and are often of questionable reliability, resulting in inconsistent results. Therefore, we have developed an ELISA that is sensitive, reliable and not susceptible to disturbances by interfering substances such as heterophilic antibodies. The assay involves a combination of four polyclonal antibodies. The antibodies, which capture the analyte, were raised in chicken and the trapping anti-analyte antibodies were raised in rabbit. The immobilization of capture antibodies was achieved via a coating antibody raised in a duck against chicken IgY and the recognition of trapping antibodies was achieved by a detection antibody raised in a goat against rabbit IgG and labelled with HRP. The analytical and functional sensitivities of the ELISA are 8 pg/mL and 13 pg/mL, respectively. The assay showed good precision and, in contrast to our in-house RIA, excellent parallelism in serial dilutions. The recovery of TNF-alpha spiked to plasma samples ranged from 97% to 119%. Comparison of the newly developed, sensitive ELISA with our in-house RIA showed that the median TNF-alpha value obtained by RIA (range: 0.095-10.0, median 0.578 ng/mL) was found to be 1.5-2 times higher than that obtained with the ELISA (range 0.008-5.84, median 0.213 ng/mL). Spearman correlation was 0.755 (p < 0.0001). In addition, analysis of the TNF-alpha concentrations in blood from healthy individuals and from patients suffering from tuberculosis, with RIA and ELISA, showed the same differences although TNF-alpha levels obtained with ELISA were lower. We feel that this ELISA is a major improvement compared to the currently available assays for TNF.  相似文献   

10.
A practical and selective HPLC method for the separation and quantification of omeprazole enantiomers in human plasma is presented. C18 solid phase extraction (SPE) cartridges were used to extract the enantiomers from plasma samples and the chiral separation was carried out on a Chiralpak AD column protected with a CN guard column, using ethanol:hexane (70:30) as the mobile phase, at a flow rate of 0.5 ml/min. The detection was carried out at 302 nm. The method proved to be linear in the range of 10-1000 ng/ml for each enantiomer, with a quantification limit of 5 ng/ml. Precision and accuracy, demonstrated by within-day and between-day assays, were lower than 10%.  相似文献   

11.
A new simple and rapid high-performance liquid chromatographic (HPLC) method with UV detection for the determination of indapamide in biological fluids has been developed. Indapamide and internal standard were isolated from serum and whole blood samples by solid-phase extraction with RP select B cartridges. The chromatographic separation was accomplished on a reversed-phase C(8) column with a mobile phase composed of 0.1% (v/v) triethylamine in water (pH 3.5) and acetonitrile (63:37, v/v). UV detection was set at 240 nm. The calibration curves were linear in the concentration range of 10.0-100.0 ng/ml for serum, and 50.0-500.0 ng/ml for whole blood, and the limits of quantification were 10.0 and 50.0 ng/ml, respectively.  相似文献   

12.
The subcommissural organ (SCO) is an ependymal brain gland that releases glycoproteins into the ventricular cerebrospinal fluid where they condense to form the Reissner’s fiber (RF). We have developed a highly sensitive and specific two-antibody sandwich enzyme-linked immunosorbent assay (ELISA) for the quantification of the bovine SCO secretory material. The assay was based on the use of the IgG fraction of a polyclonal antiserum against the bovine RF as capture antibody and a pool of three peroxidase-labeled monoclonal antibodies that recognize non-overlapping epitopes of the RF glycoproteins as detection antibody. The detection limit was 1 ng/ml and the working range extended from 1 to 4000 ng/ml. The calibration curve, generated with RF glycoproteins, showed two linear segments: one of low sensitivity, ranging from 1 to 125 ng/ml, and the other of high sensitivity between 125 and 4000 ng/ml. This assay was highly reproducible (mean intra- and interassay coefficient of variation 2.2% and 5.3%, respectively) and its detectability and sensitivity were higher than those of ELISAs using exclusively either polyclonal or monoclonal antibodies against RF glycoproteins. The assay succeeded in detecting and measuring secretory material in crude extracts of bovine SCO, culture medium supernatant of SCO explants and incubation medium of bovine RF; however, soluble secretory material was not detected in bovine cerebrospinal fluid.  相似文献   

13.
It is a challenging task to verify and quantify potential biomarkers expressed at elevated levels in sera from cancer patients. An immunoaffinity-mass spectrometry-based approach has been developed using antibodies to enrich proteins of interest from sera followed by mass spectrometry-based quantification. Antibodies specific to the protein of interest were immobilized to hydrazide resin via the carbohydrate moiety on the Fc region of the antibody. Captured proteins were eluted, reduced, alkylated, and digested with trypsin. Peptides were analyzed by LC coupled with multiple reaction monitoring approach, and quantification was achieved by the addition of stable isotope-labeled (heavy) standard peptides. Using this methodology, we were able to achieve a linear response from 15 to 250 ng/ml for carcinoembryonic antigen (CEA), a known tumor biomarker. Moreover we observed elevated levels of CEA in sera samples from lung cancer patients that to our knowledge is the first time that circulating CEA has been detected by mass spectrometry-based analysis. This approach was further applied to potential protein biomarkers discovered from tumor cell lines and tumor tissues. A linear response was obtained from a multiplex spiking experiment in normal human sera for secretory leukocyte peptidase inhibitor (4-500 ng/ml), tissue factor pathway inhibitor (TFPI) (42-1000 ng/ml), tissue factor pathway inhibitor 2 (TFPI2) (2-250 ng/ml), and metalloproteinase inhibitor 1 (TIMP1) (430-1000 ng/ml). A replicate experiment for a single concentration value yielded a relative coefficient of variation better than 11% for TFPI, secretory leukocyte peptidase inhibitor, and TFPI2. The expression level of the proteins in lung cancer patient sera was assayed by an immunoaffinity-multiple reaction monitoring method, and the results were comparable with those obtained from ELISA. This immunoaffinity-mass spectrometry-based quantification approach thus provides a specific and accurate assay for verifying the expression of potential biomarkers in patient serum samples especially for those proteins for which the necessary reagents for ELISA development are unavailable.  相似文献   

14.
A liquid chromatography-tandem mass spectrometric (LC-MS-MS) method with a rapid and simple sample preparation was developed and validated for the determination of Tirofiban in biological fluids. Tirofiban in serum samples was extracted and cleaned up by using an automated solid phase extraction method. An external calibration was used. The mass spectrometer was operated in the multiple reaction monitoring mode (MRM). A good linear response over the range of 2-200ng/ml was demonstrated. The accuracy for Tirofiban ranged from 94.8 to 110.8% within-day and from 103.0 to 104.7% between-day. The lower limit of quantification was 2ng/ml. This method is suitable for pharmacokinetic studies.  相似文献   

15.
The changes in concentration of oestrone, oestradiol (-17alpha and -17beta), oestrone sulphate and the oestradiol sulphates have been measured in allantoic and amniotic fluids and in maternal peripheral plasma throughout gestation. Oestrone sulphate was the major oestrone present in all of the fluids. It was measurable in allantoic fluid before Day 52 and reached a peak concentration of 475 ng/ml around Day 133. A lower peak occurred in the amniotic fluid around Day 110. The changes in oestradiol sulphates in allantoic fluid were similar to those of oestrone sulphate but at a much lower level. Considerable fluctuation was observed in the oestradiol sulphate concentrations in amniotic fluid. The ratio of oestradiol-17alpha sulphate to oestradiol-17beta sulphate was considerably higher in amniotic fluid than in allantoic fluid. Consistent changes in the levels of oestrone and the oestradiols were found in amniotic fluid but not in allantoic fluid during the second half of pregnancy. In maternal peripheral plasma oestrone sulphate was measurable before Day 72. In the limited number of samples analysed no difference in oestrogen concentration due to the sex of the fetus was evident in any of the fetal or maternal fluids.  相似文献   

16.
We have developed a new method for highly selective determination of the ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) concentration using a surface plasmon resonance imaging (SPRI) technique and two different biosensors. UCH-L1 was captured from a solution by immobilized specific rabbit monoclonal antibody or specific LDN-57444 inhibitor due to formation of receptor–UCH-L1 complex on the biosensor surface. The analytically useful dynamic response range of both biosensors is between 0.1 and 2.5 ng/ml. The detection limit is 0.06 ng/ml for the biosensor with antibody and 0.08 ng/ml for the biosensor with inhibitor. Biosensors based on both antibody and inhibitor were found to be suitable for quantitative determination of the UCH-L1 and exhibit good tolerance to the potential interferents. Both biosensors gave comparable results in the range of 0 to 0.20 ng/ml for plasma samples and 0.30 to 0.49 ng/ml for cerebrospinal fluid samples. To validate the new methods, comparative determination of UCH-L1 by the commercial enzyme-linked immunosorbent assay (ELISA) kit was performed. In general, in terms of UCH-L1 concentration, a good correlation between SPRI and ELISA was found. The developed biosensors can be used successfully for the determination of UCH-L1 in body fluids.  相似文献   

17.
A novel pH shock extraction procedure was used to measure nerve growth factor (NGF) levels in both normal and inflamed synovial fluids using a sensitive and specific two-site enzyme linked immunosorbant assay. To date no data is available on NGF levels in normal synovial fluids. Synovial fluids were taken from 5 normal volunteers, 12 patients with rheumatoid arthritis and 10 patients with other inflammatory arthropathies. The mean ± SEM NGF concentration in normal synovial fluids was 95 ± 33.2 pg/ml (range 39.1–143.1 pg/ml), whereas the mean NGF concentration in the synovial fluids taken from patients with rheumatoid arthritis was 532.5 ± 123.8 pg/ml (range 152–1686 pg/ml). The mean NGF concentration in patients with other inflammatory arthropathies was also raised (430.6 ± 90 pg/ml; range 89–1071 pg/ml). The NGF concentrations were significantly higher in the synovial fluids from both inflamed groups (ANOVA p < 0.05) compared to normals. Raised levels of NGF in synovial fluid may contribute directly to joint inflammation via activation of inflammatory cells.  相似文献   

18.
A specific high performance liquid chromatography-mass spectrometric (LC-MS/MS) assay was developed for the determination of captopryl in plasma. The retention time was 1.45 and 1.37 min for captopril and enalapril, respectively. The overall mean recovery, using SPE extraction with OASIS HLB cartridges, was found to be 107.2+/-9.5 and 100.04+/-2%, respectively. Calibration curves were linear in the concentration range of 10.00-2000.00 ng/ml, and the lower limit of quantification (LLOQ) was 10.00 ng/ml. The LLOQ was sensitive enough for detecting terminal phase concentrations of the drug. Inter-batch precision of the method ranged from 0.88 to 1.95%. Intra-batch accuracy ranged from 97.15 to 105.77%, while intra-batch precision ranged from 2.49 to 5.66% at concentrations of 30.00, 760.00 and 1500.00 ng/ml. The developed method was applied to study bioequivalence of captopril in a group of 25 human subjects at a single oral dose of a 50mg tablet.  相似文献   

19.
Apolipoprotein A-I (apoA-I), the major protein component of human high density lipoprotein, appears intracellularly as an intermediate precursor (proapoA-I) with a hexapeptide extension (Arg-His-Phe-Trp-Gln-Gln) at its amino terminus. To investigate the regulation of processes that regulate plasma apoA-I levels, a sensitive and simple assay for proapoA-I is required. We describe a specific enzyme-linked immunosorbent assay (ELISA) for quantification of proapoA-I using monospecific rabbit antibodies raised against the peptide: Arg-His-Phe-Trp-Gln-Gln-Asp-Glu-Pro. The monospecificity of antibodies to propeptide has been checked and no cross-reaction with mature apoA-I has been found although three first mature apoA-I amino acids (Asp-Glu-Pro) were included in the immunizing peptide. The assay is a non-competitive sandwich ELISA in which polystyrene microtiter plates were used with antibodies to propeptide adsorbed on the wells. After incubation with plasma samples, the bound proapoA-I was revealed by labeled rabbit polyclonal antibodies directed against mature apoA-I. The working range was 10 to 100 ng/ml, recovery of proapoA-I added to plasma was 94.6 to 106.5%, and the intra- and interassay coefficients of variation were 3.8% and 7.9%, respectively. A delipidation step using diisopropylether-n-butanol was necessary to expose antigen sites of proapoA-I in native lipoproteins. Mean level of proapoA-I in normal subjects was 87 +/- 15 micrograms/ml. It represented 7.1% of total apoA-I while in Tangier serum it represented 29%.  相似文献   

20.
Monoclonal antibodies (McAb) were developed to the Mr 17,500 form of human recombinant interleukin 1, IL 1 beta. Four McAb have been identified that inhibit the biological activity of IL 1 beta. McAb H34 and H67, at 1 microgram/ml (6 X 10(-9) M), completely inhibit the capacity of 1 ng/ml (6 X 10(-11) M) recombinant IL 1 beta to stimulate the proliferation of murine thymocytes or human fibroblasts in vitro. McAb H6 and H21 are approximately 10-fold less potent, and completely inhibit IL 1 beta activity at 10 micrograms/ml (6 X 10(-8) M) in both assays. The McAb do not have a significant effect on the biological activity of human recombinant IL 1 alpha in either assay. These McAb block the binding of recombinant [125I]IL 1 beta to IL 1 receptors on mouse 3T3 fibroblasts and have affinity constants for IL 1 beta in the range of 10(9) to 10(10) liters/mol. Competition studies suggest that two nonoverlapping epitopes on the IL 1 beta molecule are recognized by the McAb. H6 and H34 recognize one epitope, and H21 and H67 another. McAb H6 and H67 have been used together in a two-site ELISA to detect IL 1 beta. The sensitivity of the ELISA, which is 15 pg/ml (0.86 pM), approaches the limit of sensitivity of the thymocyte proliferation assay. The ELISA and thymocyte proliferation assay were used to quantitate IL 1 beta in E. coli LPS-stimulated human monocyte culture supernatants (HMCS). The level of IL 1 beta detected by ELISA in culture supernatants from eight donors ranged from 1.7 to 5.6 ng/ml, with a mean value of approximately 3 ng/ml. By comparison, the thymocyte proliferation assay gave levels of IL 1 in HMCS that were eight fold higher when quantitated by using recombinant IL 1 beta as a standard. This discrepancy with the bioassay used was reflected by the three fold higher maximum stimulation of thymocyte proliferation by HMCS as compared with recombinant IL 1 alpha or IL 1 beta, and only 45% inhibition of HMCS IL 1 activity by McAb. Thus, factors other than IL 1 beta account for the IL 1-like activity in monocyte culture supernatant as measured by the bioassay. The ILB1 McAb and ELISA allow for the first time-sensitive, accurate, and convenient quantitation of IL 1 beta levels in biological fluids or specimens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号