首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for the simultaneous fluorometric determination of two diuretics in urine is proposed. The combination of matrix isopotential synchronous fluorescence (MISF) and first derivative techniques provides good analytical results. MISF spectra are obtained by calculating the isopotential trajectory in the three-dimensional fluorescence spectrum for a urine solution. In the spectral contour, the trajectory is taken to be the portion of the line that passes by the fluorescence maxima of both diuretics (lambda(ex) = 365 and lambda(em) = 413 nm for amiloride and lambda(ex) = 365 and lambda(em) = 437 nm for triamterene). Because contour lines connect points of identical intensity and the trajectory is part of a contour line, it is called "isopotential." Analyses was carried out in a 1/1 (v/v) ethanol/water mixture, using an apparent pH of 6.3 provided by 0.01 M sodium/citrate citric acid buffer. Urine samples are diluted 50 times and provide linear calibration plots at amiloride and triamterene concentrations up to 320 and 100 ng mL(-1), respectively. The goodness of the analytical signal was checked by using variance analysis. Signals recorded throughout the calibration range were subjected to three calibrations per each analyte, both in the absence and in the presence of variable amounts of the other analyte. Differences between individual calibrations and slopes were compared with those within individual calibrations. Based on the results, triamterene and amiloride can be accurately quantified in the presence of each other. The limit of detection calculated according to Clayton who uses error propagation throughout the calibration curve and a noncentralized security factor was 16.8 and 2.4 ng mL(-1) for amiloride and triamterene, respectively.  相似文献   

2.
Oxidative DNA damage, linked pathogenically to a variety of diseases such as cancer and ageing, can be investigated by measuring specific DNA repair products in urine. Within the last decade, since it was established that such products were excreted into urine, progress in their analysis in urine has been limited. Guanine is the DNA base most prone to oxidation. We present a method for determination of the urinary 8-hydroxylated species of guanine, based on direct injection of urine onto a high-performance liquid chromatography (HPLC)–tandem mass spectrometry system. The analysis covers the 8-hydroxylated base, ribonucleoside and deoxynucleoside, and the corresponding non-oxidised species. Without pre-treatment of urine the detection limits for the nucleobases are ~2 nM (50 fmol injected) and for the nucleosides ~0.5 nM (12.5 fmol injected). Previously, liquid chromatography of the nucleobases has been problematic but is made possible by low-temperature reverse-phase C18 chromatography, a method that increases retention on the column. In the case of the nucleosides, retention was almost total and provides a means for on-column concentration of larger urine samples and controlled high peak gradient elution. The total excretion of 8-hydroylated guanine species was 212 nmol/24 h. The oxidised base accounted for 64%, the ribonucleoside for 23% and the deoxynucleoside for 13%, indicating substantial oxidation of RNA in humans. In rat urine, excretion of the oxidised base was more dominant, the percentages of the oxidised base, ribonucleoside and deoxynucleosides being 89, 8 and 3%. This finding is at odds with previous reports using immunoaffinity pre-purification and HPLC–electrochemical detection analysis. The developed method now makes it possible to measure oxidative nucleic acid stress to both RNA and DNA in epidemiological and intervention settings, and our findings indicate a substantial RNA oxidation in addition to DNA oxidation. The small volume needed also makes the method applicable to small experimental animals.  相似文献   

3.
We have developed an analytical method to quantitate urinary 8-nitroguanine, a product of nitrative nucleic acid damage caused by reactive nitrogen species such as peroxynitrite and nitrogen dioxide. 8-Nitroguanine was purified from human urine using immunoaffinity columns with an anti-8-nitroguanine antibody, followed by quantitation by high-performance liquid chromatography-electrochemical detection. Four sequential electrodes were used to (a) oxidize interfering compounds (+250 mV), (b) reduce nitrated bases (two online electrodes at -1000 mV), and (c) quantitate reduced derivatives (+150 mV). Using this system 8-nitroxanthine can also be detected, with the detection limits being 25 and 50 fmol/injection for 8-nitroguanine and 8-nitroxanthine, respectively. The method was used to analyze both adducts in the urine of smokers (n=12) and nonsmokers (n=17). We found that smokers excrete more 8-nitroguanine [median, 6.1 fmol/mg creatinine; interquartile range (IQR), 23.8] than nonsmokers (0; IQR, 0.90) (p=0.018), and although 8-nitroxanthine was detected in human urine, its level was not related to smoking status. This is the first report to show that 8-nitroguanine is present in human urine and the methodology developed can be used to study the pathogenic roles of this adduct in the etiology of cancers associated with cigarette smoking and inflammation.  相似文献   

4.
Two capillary electrophoresis methods have been developed for the direct determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine. Analytes were detected using conventional UV detection as well as laser-induced fluorescence (LIF) detection with an HeCd-laser operating at a wavelength of 325 nm. The results of both detection techniques were compared. Indeed, the limit of quantification was eightfold lower using LIF detection (50 ng/ml) in comparison to UV detection (400 ng/ml). As no interference due to endogenous urine compounds was observed, direct urine analysis was feasible. Analysis was very simple and fast-one run could be performed within less than 10 min (CE-UV method) and 2.5 min (CE-LIF method), respectively. Both assays were fully validated and applied to urine samples from a human volunteer. The results of the application of the CE-LIF method to human urine samples are presented in this publication.  相似文献   

5.
Ranitidine and its main metabolites, ranitidine N-oxide and ranitidine S-oxide, were determined in plasma and urine after separation using reversed-phase liquid chromatography. The mobile phase consisted of an initial isocratic step with 7:93 (v/v) acetonitrile–7.5 mM phosphate buffer (pH 6) for 8 min, followed by a linear gradient up to a 25:75 (v/v) mixture over 1 min. Detection was carried out by a post-column fluorimetric derivatization based on the reaction of the drugs with sodium hypochlorite, giving rise to primary amines that reacted with o-phthalaldehyde and 2-mercaptoethanol to form highly fluorescent products. The calibration graphs, based on peak area, were linear in the range 0.1–4 μg/ml for all drugs. The detection limits were 30, 41 and 32 ng/ml (8.6, 12.5 and 9.1 pmol) for ranitidine S-oxide, ranitidine N-oxide and ranitidine, respectively. Chromatographic profiles obtained for plasma and urine samples showed no interference from endogenous compounds.  相似文献   

6.
Capillary zone electrophoresis was employed for the determination of midecamycin using an end-column amperometric detection with a carbon fiber micro-disk bundle electrode at a constant potential of +1.15 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 1.00x10(-3) mol l(-1) Na(2)HPO(4)-3.49x10(-4) mol l(-1) NaOH (pH 11.4) for the buffer solution, 20 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, respectively. The limit of detection is 5.0x10(-7) mol l(-1) or 0.41 fmol (S/N=3). The linear range of the calibration curve is 1.00x10(-6)-1.00x10(-3) mol l(-1). The relative standard deviation is 1.4% for the migration time and 4.9% for the electrophoretic peak current. The method could be applied to the determination of midecamycin in human urine. In this case, a separation voltage of 14 kV was used.  相似文献   

7.
A rapid chromatographic procedure with a C18 column, a mobile phase of 0.15 M sodium dodecyl sulfate (SDS)-10% (v/v) 1-propanol at pH 3 (0.01 M phosphate buffer), and fluorimetric detection, is reported for the control of propranolol (PPL) intake in urine samples, which are injected directly without any other treatment than filtration. The peak of PPL was only observed in samples taken a few hours after ingestion of the drug due to its extensive conjugation and metabolisation. The detection of several unconjugated PPL metabolites was therefore considered: desisopropylpropranolol (DIP), propranolol glycol (PPG), alpha-naphthoxylactic acid (NLT) and alpha-naphthoxyacetic acid (NAC). NLT showed the best characteristics: it eluted at a much shorter retention time than PPL, its concentration in urine samples was greater and it did not present any interference from endogeneous compounds in urine, common drugs or drugs administered in combination with PPL. The limit of quantification, measured as the concentration of analyte providing a relative standard deviation of 20%, was 24 ng/ml, and the day-to-day imprecision was below 4% for concentrations above 200 ng/ml. The procedure allows the routine control of PPL at therapeutic urine levels. Urinary excretion studies showed that the detection of NLT is possible at least up to 20-30 h after oral administration.  相似文献   

8.
Morphine is present in varying amounts as an endogenous product in human urine. Derivatization of morphine contained in urine with dansyl chloride yields a known product, which can be quantified by liquid chromatography mass spectrometry with high selectivity and sensitivity. Urine samples of 51 healthy individuals were spiked with stable-isotope labeled morphine, hydrolyzed and subjected to solid phase extraction followed by derivatization of morphine with dansyl chloride. The dansyl derivatives of naturally occurring morphine and deuterated internal standard were then detected by liquid chromatography-triple quadrupole mass spectrometry. Using the [N-CD(3)]-labeled internal standard and solid-phase extraction, a limit of detection of 35 fmol/ml (10 pg/ml) and a limit of quantification of 87.5 fmol/ml (25 pg/ml) was determined for morphine in human urine. This new LC-MS/MS method allowed the detection of endogenous morphine in human urine of 51 volunteers with an average value of 156.4 fmol/ml (44.7 ng/ml).  相似文献   

9.
8-Hydroxy-2'-deoxyguanosine (8-OH-dG) has attracted enormous attention in recent years because it has been acknowledged as a typical biomarker of oxidative DNA damage. In this paper, the electrochemical performance of 8-OH-dG at the poly(3-methylthiophene) (P3MT) modified glassy carbon electrode (GCE) was investigated by cyclic voltammetry (CV) and linear sweep voltammetry (LSV). The conducting polymer P3MT can effectively decrease the oxidation peak potential of 8-OH-dG and greatly enhance its peak current. In 0.1 M pH 7.0 phosphate buffer solution (PBS), the anodic peak currents of cyclic voltammograms are linear with the 8-OH-dG concentration in two intervals, viz. 0.700-35.0 microM and 35.0-70.0 microM, with the correlative coefficients of 0.9992 and 0.9995, respectively. The detection limit of 8-OH-dG can be estimated to be 0.100 microM (S/N=3). This modified electrode can be used to detect the amount of 8-OH-dG in human urine. Furthermore, the effects of scan rate, pH, and interference of uric acid (UA) for the voltammetric behavior and detection of 8-OH-dG are also discussed. This proposed modified electrode also shows excellent reproducibility and stability that makes it an ideal candidate for amperometric detection of 8-OH-dG in flow injection analysis (FIA) and high performance liquid chromatography (HPLC).  相似文献   

10.
Following the oral administration of 14C-bumetanide to four male volunteers, approximately 81% of the dose was excreted in the urine within 48 hrs. The remaining 14C was found in the feces and had entered the intestine via the bile. Benzene extraction of urine at pH 3.2 quantitatively extracted bumetanide from its metabolites and indicated that 63.5% of urinary 14C was unchanged bumetanide. Metabolites identified to data indicate metabolism occurring on the butyl side chain, with the primary alcohol being the major metabolite. Conjugates of these metabolites and of bometanide were also found in the urine. Only conjugates of bumetanide and its metabolites were found in the bile.  相似文献   

11.
A procedure is described for the quantification of the major malondialdehyde deoxyguanosine adduct, pyrimido[1,2-alpha]purin-10(3H)-one-deoxyribose (M(1)GdR) in urine. M(1)GdR is isolated from urine by a combination of C(18) solid-phase extraction and immunoaffinity chromatography. Sodium borohydride treatment reduces M(1)GdR to the 5,6-dihydro derivative, which is quantified by liquid chromatography-mass spectrometry. Authentic [7,9-15N,8-13C]M(1)GdR is added to urine as an internal standard. A detection limit of 50 fmol M(1)GdR/ml urine is achieved starting with 5 ml of urine. Analysis of urine samples from control rats or rats treated with CCl(4) indicates that the levels of M(1)GdR are below the detection limit of the assay. This method is easily adaptable to the analysis of M(1)GdR in DNA samples or biological fluids.  相似文献   

12.
A simple method of hollow fiber-liquid phase microextraction (HF-LPME) combined with gas chromatography (GC) was developed for the analysis of four phenothiazine drugs (promethazine, promazine, chlorpromazine and trifluoperazine) in human urine samples. All variables affecting the extraction of target analytes including organic solvent type, stirring rate, extraction time, extraction temperature, pH of sample solution and ionic strength were carefully studied and optimized. Under the optimal conditions, the analytical performance of HF-LPME-GC-flame photometric detector (FPD) and HF-LPME-GC-flame ionization detector (FID) were evaluated and compared. The results showed that the HF-LPME-GC-FID was more sensitive than HF-LPME-GC-FPD for the determination of four target phenothiazine drugs, while the signal peak shape and resolution obtained by HF-LPME-GC-FPD was better than that obtained by HF-LPME-GC-FID. HF-LPME-GC-FPD/FID was successfully applied for the assay of the interested phenothiazine drugs in urine sample, and the excretion of the drugs was also investigated by monitoring the variation of the concentration of chlorpromazine in urine of a psychopath within 8 h after drug-taking. The proposed method provided an effective and fast way for the therapeutic drug monitoring (TDM) of phenothiazine.  相似文献   

13.
A high-performance liquid chromatographic method for the measurement of bumetamide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol—water—glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5–2000 ng/ml.  相似文献   

14.
A method for the determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA and urine by High Performance Liquid Chromatography (HPLC)-Tandem Mass Spectrometry is described. For the urine samples there is no sample preparation except for addition of buffer and internal standards followed by redissolvation of precipitate containing 8-oxo-2'-deoxyguanosine and a centrifugation step before the samples are injected onto the HPLC column. The detection limit for 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine is approximately 0.3 nM corresponding to 7.5 fmol injected. Long runs, that is, > 50 samples, can be analyzed with only minimal loss of sensitivity. The concentrations excreted into urine samples from humans are between 1 and 100 nM for 8-oxo-2'-deoxyguanosine and below 0.3 nM for 8-oxo-2'-deoxyadenosine. In calf thymus DNA levels down to about 1 oxidized guanosine and adenosine per 10(6) unmodified bases can be detected. High levels of 8-oxo-2'-deoxyguanosine were found, 30 per 10(6) 2'-deoxyguanosine, levels of 8-oxo-2'-deoxyadenosine are at or below the detection limit. These findings indicate that High Performance Liquid Chromatography-Tandem Mass Spectrometry is a highly sensitive and specific method for analysis of oxidative DNA modifications in tissue as well as for analysis of excretion of oxidized nucleotides into urine that ensures a minimum artifact formation.  相似文献   

15.
The use of micellar liquid chromatography for the determination of diuretics in urine by direct injection of the sample into the chromatographic system is discussed. The retention of the urine matrix at the beginning of the chromatograms was observed for different sodium dodecyl sulphate (SDS) mobile phases. The eluent strengths of a hybrid SDS—methanol micellar mobile phase for several diuretics were compared and related to the stationary phase/water partition coefficient with a purely micellar mobile phase. The urine band was appreciably narrower with a mobile phase of 0.05 M SDS—5% methanol (v/v) at 50°C (pH 6.9). With this mobile phase the determination of bendroflumethiazide and chlorthalidone was adequate. Acetazolamide, ethacrynic acid, furosemide, hydrochlorothiazide and probenecid were overlapped by the urine matrix, and the retention of amiloride and triamterene was too long.  相似文献   

16.
Eleven diphenylmethane antihistaminic drugs and their analogues were tested for their detection by capillary gas chromatography (GC) with surface ionization detection (SID). The GC—SID response was highest for doxylamine, diphenhydramine and orphenadrine and lowest for terodiline, clemastine and pipethanate. The detection limits for drugs with the highest response were 2–5 pg (ca. 6–20 fmol) on-column (100–250 pg/ml of body fluid). The detection limits with GC—SID were 10–100 times higher than those with GC with nitrogen—phosphorus detection. A detailed procedure for the isolation of the antihistaminics from human whole blood and urine by the use of Sep-Pak C18 cartridges, prior to GC—SID, is also presented. The recoveries of the drugs (50 or 500 pmol), which had been added to 1 ml of body fluids, were>60%. The baselines remained steady as the column temperature was increased and the background was clean, especially for whole blood extracts.  相似文献   

17.
A sensitive and specific assay aimed at measuring 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodGuo) has been developed by associating a reversed-phase liquid chromatographic separation with an electrospray tandem mass spectrometric detection. The HPLC–MS approach in the single ion monitoring (SIM) mode and the HPLC–MS/MS assay in the multiple reaction monitoring (MRM) mode have been compared, using isotopically labeled [M+4] 8-oxodGuo as the internal standard. The limit of detection of 8-oxodGuo was found to be around 5 pmol and 20 fmol for the HPLC–MS and HPLC–MS/MS methods, respectively. The HPLC–MS/MS assay is sensitive enough to allow the determination of the level of 8-oxodGuo in cellular liver DNA and in urine samples.  相似文献   

18.
A highly sensitive quantitative method based on LC-MS/MS was developed to simultaneously and directly measure 8-oxo-7,8-dihydroguanine (8-oxoGua) and 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodGuo) in urine. It was found that 8-oxoGua could be artifactually generated from 8-oxodGuo during the ionization process by both in-source thermolysis and collisionally induced dissociation. Our method applied a two-stage wash procedure in the online solid-phase extraction system that not only eliminated ion suppression but also prevented artifactual interference with 8-oxoGua by 8-oxodGuo by eluting the analytes individually. With the use of isotope internal standards, the detection limits of 8-oxoGua and 8-oxodGuo were estimated to be 30 and 3.5 fmol, respectively. The 8-oxoGua stability under common storage conditions was first investigated. Dissolved 8-oxoGua in NaOH (pH 12) was quite fragile and stable for only < 1 day at room temperature. When pH and temperature were reduced, the 8-oxoGua stability at ? 20°C was significantly increased to ~ 87 days in water (pH ~ 7) and ~ 112 days when diluted in 5% methanol. This method was further applied to measure urinary samples of healthy subjects. A molar ratio of 8-oxoGua to 8-oxodGuo of ~ 4.6 was found, supporting the hypothesis that oxidatively damaged DNA is primarily repaired by the base excision repair pathway.  相似文献   

19.
The double coating principle of CEofix buffers was evaluated for the analysis of some basic drugs by capillary electrophoresis-diode-array detection (CE-DAD) and capillary electrophoresis-mass spectrometry (CE-MS). The involatile phosphate present in original low pH CEofix, was replaced with formic acid for hyphenation of CE with MS. The double coating produces a substantial and highly reproducible electroosmotic flow (EOF), even at low pH. The rinsing procedure and electrolyte composition were optimized for both CE-DAD and CE-MS. The system was evaluated with the analysis of a mixture of basic drugs and a spiked urine sample enriched by solid-phase extraction (SPE). The R.S.D. values on the migration time and peak area measured for 28 analyses with CE-DAD were below 0.25 and 2.40%, respectively. For CE-MS, the R.S.D. on the migration time was 0.85% or less and the area precision ranged from 5.65 to 14.33% (for seven injections). The LOD with the developed CE-MS method was below 50 ppb for all five drug standards tested.  相似文献   

20.
A simple method for determination of perphenazine by capillary zone electrophoresis with amperometric detection is described. The optimum conditions of separation and detection are 1.50 x 10(-3) mol/l Na(2)B(4)O(7)-1.0 x 10(-3) mol/l NaOH (pH 9.9) for the buffer solution, 18 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, and 0.80 V versus saturated calomel electrode for the detection potential, respectively. The limit of detection is 5.0 x 10(-8) mol/l or 44 amol (S/N=3). The linear range of the calibration curve is 1.00 x 10(-7) to 1.00 x 10(-4) mol/l. The relative standard deviation is 1.5% for the migration time and 2.9% for the electrophoretic current at peak maximum. The method is applied to the determination of perphenazine in human urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏