首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method with positive electrospray ionization (ESI) was developed for the quantification of ranolazine in human plasma. After liquid-liquid extraction of ranolazine and internal standard (ISTD) phenoprolamine from a 100 microl specimen of plasma, HPLC separation was achieved on a Nova-Pak C(18) column, using acetonitrile-water-formic acid-10% n-butylamine (70:30:0.5:0.08, v/v/v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 428.5-->m/z 279.1 for ranolazine and m/z 344.3-->m/z 165.1 for the internal standard, respectively. Linear calibration curves were obtained in the concentration range of 5-4000 ng/ml, with a lower limit of quantitation (LLOQ) of 5 ng/ml. The intra- and inter-day precision values were below 3.7% and accuracy was within +/-3.2% at all three quality control (QC) levels. This method was found suitable for the analysis of plasma samples collected during the phase I pharmacokinetic studies of ranolazine performed in 28 healthy volunteers after single oral doses from 200 mg to 800 mg.  相似文献   

2.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with electrospray ionization (ESI) was developed and validated for the simultaneous determination of pitavastatin and its lactone in human plasma and urine. Following a liquid-liquid extraction, both the analytes and internal standard racemic i-prolact were separated on a BDS Hypersil C(8) column, using methanol-0.2% acetic acid in water (70: 30, v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 422.4-->m/z 290.3 for pitavastatin, m/z 404.3-->m/z 290.3 for pitavastatin lactone and m/z 406.3-->m/z 318.3 for the internal standard, respectively. Linear calibration curves of pitavastatin and its lactone were obtained in the concentration range of 1-200 ng/ml, with a lower limit of quantitation of 1 ng/ml. The intra- and inter-day precision values were less than 4.2%, and accuracies were between -8.1 and 3.5% for both analytes. The proposed method was utilized to support clinical pharmacokinetic studies of pitavastatin in healthy subjects following oral administration.  相似文献   

3.
We described the development and full validation of rapid and accurate liquid chromatography method, coupled with tandem mass spectrometry detection, for quantification of meprobamate in human plasma with [(13)C-(2)H(3)]-meprobamate as internal standard. Plasma pretreatment involved a one-step protein precipitation with acetonitrile. Separation was performed by reversed-phase chromatography on a Luna MercuryMS C18 (20 mm×4 mm×3 μm) column using a gradient elution mode. The mobile phase was a mix of distilled water containing 0.1% formic acid and acetonitrile containing 0.1% formic acid. The selected reaction monitoring transitions, in electrospray positive ionization, used for quantification were 219.2→158.2 m/z and 223.1→161.1m/z for meprobamate and internal standard, respectively. Qualification transitions were 219.2→97.0 and 223.1→101.1 m/z for meprobamate and internal standard, respectively. The method was linear over the concentration range of 1-300 mg/L. The intra- and inter-day precision values were below 6.4% and accuracy was within 95.3% and 103.6% for all QC levels (5, 75 and 200 mg/L). The lower limit of quantification was 1 mg/L. Total analysis time was reduced to 6 min including sample preparation. The present method is successfully applied to 24/7 clinical toxicology and demonstrated its usefulness to detect meprobamate poisoning.  相似文献   

4.
Vinorelbine is a semi-synthetic vinca alkaloid with demonstrated high activities against various types of advanced cancer. To support a clinical pharmacokinetic study, a simple, rapid and sensitive method to determine vinorelbine in human plasma was developed using reversed phase liquid chromatography (LC) coupled with electrospray ionization mass spectrometry/mass spectrometry (ESI-MS/MS). Vinorelbine and vinblastine (the internal standard) were extracted from human plasma by one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether. The chromatographic separation was achieved on a Spursil polar-modified C(18) column (50 mm×2.1 mm, 3 μm, Dikma Technologies) with an isocratic mobile phase of a 75:25 (v/v) acetonitrile-4 mmol/L ammonium formate (pH 3.0) mixture at a flow-rate of 0.4 mL/min. The MS/MS detection was performed in the positive ion multiple reaction monitoring (MRM) mode by monitoring the precursor→product ion transitions at m/z 779.4→122.0 and m/z 811.3→224.2 for vinorelbine and the internal standard, respectively. The assay was validated in the range 0.1-200 ng/mL (r>0.997), the lowest level of this range being the lower limit of quantification (LLOQ) based on 50 μL of plasma. The intra- and inter-day precisions were within 6.0%, while the accuracy was within ±4.7% of nominal values. Detection and quantification of both analytes within 2 min make this method suitable for high-throughput analyses. The method was successfully applied to evaluate the systemic pharmacokinetics of vinorelbine after a 20-min intravenous infusion of 25 mg/m(2) of vinorelbine to patients with metastatic breast cancer.  相似文献   

5.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of rivastigmine in human plasma. Rivastigmine was extracted from human plasma by using solid-phase extraction technique. Zolpidem was used as the internal standard. A Betabasic-8 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 251.20-->206.10, 86.20 for rivastigmine and m/z 308.10-->235.10 for zolpidem. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatographic conditions and mass spectrometric detection that enables detection at sub-nanogram levels. The proposed method has been validated for a linear range of 0.2-20.0 ng/ml with a correlation coefficient > or =0.9988. The intra-run and inter-run precision and accuracy were within 10.0%. The overall recoveries for rivastigmine and zolpidem were 86.28% and 87.57%, respectively. The total run time was 2.0 min. The developed method was applied for the determination of the pharmacokinetic parameters of rivastigmine following a single oral administration of a 3 mg rivastigmine capsule in 20 healthy male volunteers.  相似文献   

6.
A sensitive and selective liquid chromatography-tandem spectrometry method for the determination of zolmitriptan was developed and validated over the linearity range 0.05-30 ng/ml with 0.5 ml of plasma using diphenhydramine as the internal standard. Liquid-liquid extraction using a mixture of diethyl ether and dichloromethane was used to extract the drug and the internal standard from plasma. The mass spectrometer was operated under the selected reaction monitoring (SRM) mode using the atmospheric pressure chemical ionization (APCI) technique. The instrument parameters were optimized to obtain 3.0 min run time. The mobile phase consisted of acetonitrile-water-formic acid (70:30:0.5), at a flow rate of 0.5 ml/min. In positive mode, zolmitriptan produced a protonated precursor ion at m/z 288 and a corresponding product ion at m/z 58. And internal standard produced a protonated precursor ion at m/z 256 and a corresponding product ion at m/z 167. The inter- and intra-day precision (%R.S.D.) were less than 8.5% and accuracy (%error) was less than -2.5%. The method had a lower limit of quantification of 0.05 ng/ml for zolmitriptan, which offered increased sensitivity and selectivity of analysis, compared with existing methods. The method was successfully applied to a pharmacokinetic study of zolmitriptan after an oral administration of 5 mg zolmitriptan to 20 healthy volunteers.  相似文献   

7.
A high throughput and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of bisoprolol in human plasma using multiplexing technique (two HPLC units connected to one MS). Bisoprolol was extracted from human plasma using solid-phase extraction technique using metoprolol as internal standard. A Betabasic 8 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 326.2-->116.1 for bisoprolol and m/z 268.2-->191.0 for metoprolol. The method involves a simple multiplexing, rapid solid-phase extraction, simple isocratic chromatography conditions and mass spectrometric detection which enable detection at sub-nanogram levels. The proposed method has been validated for a linear range of 0.5-70.0 ng/mL with correlation coefficient > or =0.9991. The precision and accuracy were within 10% for intra-HPLC runs and inter-HPLC runs. The overall recoveries for bisoprolol and metoprolol were 93.89% and 77.65%, respectively. Total MS run time was 0.90 min only. The developed method was applied for the determination of pharmacokinetic parameters of bisoprolol following a single oral administration of a 10mg bisoprolol tablet in 18 healthy male volunteers.  相似文献   

8.
A rapid, specific and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed for simultaneous quantitation of six Aconitum alkaloids, i.e. aconitine (AC), mesaconitine (MA), hypaconitine (HA), benzoylaconine (BAC), benzoylmesaconine (BMA) and benzoylhypaconine (BHA) in human plasma collected from 18 healthy volunteers after intravenous drop infusion of "SHEN-FU" injectable powder in three different dosages. Lappaconitine was selected as the internal standard (IS). LC/MS/MS system coupled with an electrospray ionization (ESI) source was performed in multiple-reaction monitoring (MRM) mode. The transitions of the Aconitum alkaloids executed as following: m/z 646.3-->586.0 for AC; m/z 632.4-->573.1 for MA; m/z 616.2-->556.1 for HA; m/z 604.2-->104.8 for BAC; m/z 590.1-->104.8 for BMA; m/z 574.1-->104.8 for BHA; m/z 585.2-->161.8 for IS. Sample preparation was performed with solid-phase extraction (SPE) on a 1 mL HLB cartridge prior to analysis. The separation was applied on a Waters C(18) column (1.7 microm, 2.1 mm x 100 mm) and a gradient elution of methanol and 0.1% formic acid-water was used as mobile phase. The retention time was less than 4.5 min. The concentrations ranged from 0.1 to 1000 ng/mL for all six Aconitum alkaloids and showed a good linearity with the correlation coefficient (r(2)) >0.995. The validated method was employed to simultaneous quantitation and successfully used for the first time for the pharmacokinetic evaluation of the six Aconitum alkaloids after intravenous drop administration of "SHEN-FU" injectable powder in phase I clinical trial.  相似文献   

9.
A simple, reliable and sensitive liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for quantification of N-acetylglucosamine in human plasma. Plasma samples were pretreated with acetonitrile for protein precipitation. The chromatographic separation was performed on Hypersil Silica column (150mmx2mm, 5microm). The deprotonated analyte ion was detected in negative ionization mode by multiple reaction monitoring mode. The mass transition pairs of m/z 220.3-->118.9 and m/z 226.4-->123.2 were used to detect N-acetylglucosamine and internal standard 13C6-N-acetylglucosamine, respectively. The assay exhibited a linear range from 20 to 1280ng/ml for N-acetylglucosamine in human plasma. Acceptable precision and accuracy were obtained for concentrations of the calibration standard and quality control. The validated method was successfully applied to analyze human plasma samples in a pharmacokinetic study.  相似文献   

10.
The antifungal polyene antibiotics nystatin was tested in a clinical trial to describe pharmacokinetics and safety after repeated administration of Nystatin "Lederle" sterile powder in healthy volunteers. To monitor the nystatin concentration-time profile in plasma we developed a sensitive method in the range of 1-100ng/ml based on liquid chromatography coupled with tandem mass spectrometry. The target substance was separated from the biological matrix on C(18) solid-phase extraction cartridges with methanol. The Chromatography was performed isocratically using a reversed phase Caltrex Resorcinearene column. The mobile phase consisted of 5mM ammonium formate buffer and acetonitrile (40:60, v/v). The mass spectrometer works with electrospray ionization in its positive selected ion monitoring (SIM) mode using the respective MH(+) ions, m/z 926.6 for nystatin and m/z 924.4 for amphotericin B as internal standard. The method validation was performed according to the demands and international criteria for validation of bioanalytical methods and was successfully applied to the quantification of nystatin in human plasma in the pharmacokinetic trial.  相似文献   

11.
Bestatin is a low molecular weight aminopeptidase inhibitor originally isolated from culture filtrates of Streptomyces olivoreticuli. We have developed a sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the quantitative determination of bestatin in rat plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 50 microL plasma samples by solid phase extraction (SPE). Reverse-phase HPLC separation was accomplished on a Lichrospher C18 column (4.6 mm x 50 mm, 5 microm) with a mobile phase composed of methanol-water-formic acid (70:30:0.5, v/v/v) at a flow rate of 0.8 mL/min. The method had a chromatographic total run time of 3 min. A Varian 1200L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 309.2-->120.0 (bestatin) and 313.4-->138.0 (granisetron) used for quantitation. The method was sensitive with a lower limit of quantitation (LLOQ) of 5 ng/mL, with good linearity (r2 >or= 0.999) over the linear range of 5-2000 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic study of bestatin in rats.  相似文献   

12.
A new LC-ESI-MS/MS assay method has been developed and validated for the quantification of swertiamarin, a representative bioactive substance of Swertia plants, in rat plasma using gentiopicroside, an analog of swertiamarin on chemical structure and chromatographic action, as the internal standard (IS). The swertiamarin and IS were extracted from rat plasma using solid-phase extraction (SPE) as the sample clean-up procedure, and they were chromatographed on a narrow internal diameter column (Agilent ZORBAX ECLIPSE XDB-C(18) 100 mm × 2.1 mm, 1.8 μm) with the mobile phase consisting of methanol and water containing 0.1% acetic acid (25:75, v/v) at a flow rate of 0.2 mL/min. The detection was performed on an Agilent G6410B tandem mass spectrometer by negative ion electrospray ionisation in multiple-reaction monitoring mode while monitoring the transitions of m/z 433 [M+CH(3)COO](-)→179 and m/z 415 [M+CH(3)COO](-)→179 for swertiamarin and IS, respectively. The lower limit of quantification (LLOQ) was 5 ng/mL within a linear range of 5-1000 ng/mL (n=7, r(2)≥0.994), and the limit of detection (LOD) was demonstrated as 1.25 ng/mL (S/N≥3). The method also afforded satisfactory results in terms of sensitivity, specificity, precision (intra- and inter-day), accuracy, recovery, freeze/thaw, long-time stability and dilution integrity. This method was successfully applied to determination of the pharmacokinetic properties of swertiamarin in rats after oral administration at a dose of 20 mg/kg. The following pharmacokinetic parameters were obtained (mean): maximum plasma concentration, 1920.1 ng/mL; time to reach maximum plasma concentration, 0.945 h; elimination half-time, 1.10h; apparent total clearance, 5.638 L/h/kg; and apparent volume of distribution, 9.637 L/kg.  相似文献   

13.
A liquid chromatography-tandem mass spectrometric method (LC-MS/MS) has been developed and validated to determine the concentration of Kendine 91 in mice plasma and tissues. Simvastatin was employed as the internal standard. Separation was performed on a C8 column, with a mobile phase consisting of methanol and aqueous 10 mM formic acid (73:27 v/v). Both analyte and internal standard were determined using electrospray ionization and the MS data acquisition was via multiple-reaction monitoring (MRM) in positive scanning mode. Quantification was performed using the transitions m/z 444-->169 and 441-->325 for Kendine 91 and simvastatin, respectively. The method was validated with respect to linearity, accuracy, precision, recovery and stability. This assay has been successfully applied to a pharmacokinetic study after intravenous injection of Kendine 91 in mice in a dose of 10mg/kg.  相似文献   

14.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometry (LC-MS-MS) method is described for the determination of duloxetine in human plasma. Duloxetine was extracted from plasma using methanol and separated on a C18 column. The mobile phase consisting of a mixture of acetonitrile and 5mM ammonium acetate (45:55, v/v, pH 3.5) was delivered at a flow rate of 0.3 ml/min. Atmospheric pressure ionization (API) source was operated in positive ion mode. Multiple reaction monitoring (MRM) mode using the transitions of m/z 298.1-->m/z 44.0 and m/z 376.2-->m/z 123.2 were used to quantify duloxetine and internal standard (I.S.), respectively. The linearity was obtained over the concentration range of 0.1-50.0 ng/ml and the lower limit of quantitation (LLOQ) was 0.1 ng/ml. This method was successfully applied to pharmacokinetic study of a duloxetine formulation product after oral administration to healthy human subjects.  相似文献   

15.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for simultaneous quantification of venlafaxine (VEN) and O-desmethyl venlafaxine (ODV) in human plasma. The analytes were extracted from human plasma by using solid-phase extraction (SPE) technique. Escitalopram (ESC) was used as the internal standard. A Betasil C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair has been followed as m/z 278.27-->121.11 for VEN, m/z 264.28-->107.10 for ODV and m/z 325.00-->262.00 for ESC. The method involves a solid phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection at nanogram levels. The proposed method has been validated with linear range of 3-300 ng/ml for VEN and 6-600 ng/ml for ODV. The intrarun and interrun precision and accuracy values are within 10%. The overall recoveries for VEN and ODV were 95.9 and 81.7%, respectively. Total elution time as low as 3 min only.  相似文献   

16.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of beraprost, a stable, orally active prostacyclin analogue with vasodilatory, antiplatelet and cytoprotective effects. The analyte and internal standard, indomethacin, were extracted by solid-phase extraction using OASIS HLB cartridge. The chromatographic separation was performed on a C18 column with a mobile of 0.1% formic acid-methanol (30:70, v/v). The highest daughter ion of deprotonated analyte was quantitated in negative ionization by multiple reactions monitoring with a mass spectrometer. The mass transitions m/z 397>269 and m/z 356>312 were used to measure beraprost and internal standard, respectively. The assay exhibited a linear range from 0.02 to 2 ng/mL for beraprost in human plasma. The lower limit of quantitation was 20 pg/mL with a relative standard deviation of less than 20%. The method was validated with respect to linearity, sensitivity, specificity, recovery, accuracy and precision. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic study.  相似文献   

17.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of metolazone in human blood. Metolazone was extracted from blood using ethyl acetate and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of acetonitrile, 10 mmol/l ammonium acetate and formic acid (60:40:0.1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Electrospray ionization (ESI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 366-->m/z 259 and m/z 321-->m/z 275 were used to quantify metolazone and the lorazepam (internal standard), respectively. The linearity was obtained over the concentration range of 0.5-500 ng/ml for metolazone and the lower limit of quantitation (LLOQ) was 0.5 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 8.07 and 3.56% (relative standard deviation (RSD)), respectively, and the bias was within +/-4.0%. This method was successfully applied to the pharmacokinetic study of metolazone formulation after oral administration to humans.  相似文献   

18.
Rimonabant is the first therapeutically relevant cannabinoid antagonist, licensed in Europe for treatment of obesity when a risk factor is associated. The objective of this study was to develop and validate a method for measurement of rimonabant in human plasma and hair using liquid chromatography coupled to mass spectrometry (LC-MS/MS). Rimonabant and AM-251 (internal standard) were extracted from 50muL of plasma or 10mg of hair using diethylether. Chromatography was performed on a 150mmx2.1mm C18 column using a mobile phase constituted of formate buffer/acetonitrile. Rimonabant was ionized by electrospray in positive mode, followed by detection with mass spectrometry. Data were collected either in full-scan MS or in full-scan MS/MS mode, selecting the ion m/z 463.1 for rimonabant and m/z 555.1 for IS. The most intense product ion of rimonabant (m/z 380.9) and IS (m/z 472.8) were used for quantification. Calibration curves covered a range from 2.5 (lower limit of quantification) to 1000.0ng/mL (upper limit of quantification) in plasma and from 2.5 to 1000.0pg/mg in hair. Validation results demonstrated that rimonabant could be accurately and precisely quantified in both matrixes: accuracy and precision were within 85-115% and within 15% of standard deviation, respectively. Stability studies in plasma showed that rimonabant was stable during the assay procedure, but a 30% decrease was observed for one concentration after 3 weeks at -20 degrees C. This simple and robust LC-MS/MS method can be used for measuring rimonabant concentrations in human plasma and hair either in clinical or in forensic toxicology.  相似文献   

19.
A high-performance liquid chromatographic assay with tandem mass spectrometric detection was developed and validated for quantitation of the broad spectrum kinase inhibitor, flavopiridol, in human plasma. Sample preparation conditions included liquid-liquid extraction in acetonitrile (ACN), drying, and reconstitution in 20/80 water/ACN. Flavopiridol and the internal standard (IS), genistein, were separated by reversed phase chromatography using a C-18 column and a gradient of water with 25 mM ammonium formate and ACN. Electrospray ionization and detection of flavopiridol and genistein were accomplished with single reaction monitoring of m/z 402.09>341.02 and 271.09>152.90, respectively in positive-ion mode [M+H](+) on a triple quadrupole mass spectrometer. Recovery was greater than 90% throughout the linear range of 3-1000 nM. Replicate sample analysis indicated within- and between-run accuracy and precision to be less than 13% throughout the linear range. This method has the lowest lower limit of quantitation (LLOQ) reported to date for flavopiridol, and it allows for more accurate determination of terminal phase concentrations and improved pharmacokinetic parameter estimation in patients receiving an active dosing schedule of flavopiridol.  相似文献   

20.
This paper describes a simple, robust and cost-effective assay for the determination of ecabet in human plasma. After a simple step of protein precipitation using methanol, plasma samples were analyzed by reverse phase high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) with valsartan as the internal standard (I.S.). Ecabet and the I.S. valsartan were separated on a Venusil MP C18 analytical column using methanol-10mM ammonium acetate (75:25, v/v, pH 3.0) as mobile phase at a flow rate of 1.0 mL/min. Ecabet and I.S. were eluted at 0.91 and 0.92 min, respectively, ionized in negative mode, and then detected by multiple reaction monitoring (MRM) essay. The MRM transitions of m/z 379.1-->m/z 277.1 and m/z 434.3-->m/z 350.1 were used to quantify ecabet and I.S., respectively. The assay was linear over the concentration range of 10-6000 ng/mL and was successfully applied to a pharmacokinetic study in healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号