首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 13 毫秒
1.
A rapid and sensitive analytical method has been developed for the simultaneous determination of 16 non-steroidal anti-inflammatory drugs (NSAIDs) in human plasma by capillary liquid chromatography (LC) and quadrupole mass spectrometry with electrospray ionization operated in the negative ion mode. The sample clean-up and enrichment on a pre-column were accomplished on-line to improve the sensitivity. This method greatly reduced sample preparation time and sample volume compared with off-line sample extraction methods and conventional LC methods, respectively. The recoveries of NSAIDs from human plasma were 56.7-96.9%. The total analytical time for a single analytical run was approximately 15 min. The detection limits of NSAIDs were 0.001-0.075 microg ml(-1) using a selected ion monitoring mode.  相似文献   

2.
We report a new design of a fully automated, high-efficiency parallel nonsplit nanoflow capillary HPLC system, coupled on-line with linear ion trap (LTQ) and high performance nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoESI LTQ-FTICR MS). The system, intended for high-throughput proteome analysis of complex protein mixtures, notably serum and plasma, consists of two reversed-phase trap columns for large volume sample injection with high speed sample loading and desalting and two reversed-phase analytical capillary columns. Through a nanoscale two-position, 10-port switching valve, the whole system is terminated by a 10 microm i.d. of nanoemitter mounted on the nanoelectrospray source in front of the sampling cone of the LTQ-FTICR MS. Gradient elution to both nanoflow-rate capillary columns is simultaneously delivered by a single HPLC system via two independent binary gradient pump systems. The parallel capillary column approach eliminates the time delays for column regeneration/equilibration since one capillary column is used for separating the sample mixtures and delivering the separated fractions to the MS, while the other capillary column is being regenerated and equilibrated. The reproducibility of retention time and peak intensity of the present automated parallel nanoflow-rate capillary HPLC system is comparable to that obtained using a single column configuration. Replicate injections of tryptic digests indicated that this system provided good reproducibility of retention time and peak area on both columns with average CV values of less than 1.08% and 7.04%, respectively. Throughput was increased to 100% for 2-h LC-MS analysis compared to the single capillary column LC-MS pipeline. Application of this system is demonstrated in a plasma proteomic study. A total of 312 868 MSMS events were acquired and 1564 proteins identified with high confidence (Protein Prophet > or = 0.9, and peptides matched > or = 2). Comparison of a series of plasma fractions run using the single-column LC-MS versus the parallel-column LC-MS demonstrated that parallel-column LC-MS system significantly reduced the sample carryover, improved MS data quality and increased the number of MS/MS sequence scan events.  相似文献   

3.
Antigen-antibody interactions in capillary electrophoresis   总被引:2,自引:0,他引:2  
Immunoreactions in combination with separations by capillary electrophoresis (CE) are increasingly being used to quantitate specific analytes in biological fluids. Both competitive and non-competitive approaches have been used for the purpose and, in selected cases, now compare favorably with conventional quantitative immunoassays with respect to concentration limits of detection. CE is also a useful method to evaluate antigen-antibody binding on-line and offers unique possibilities for binding constant estimates, also for weakly binding antibodies and antibody fragments. In this review we cover recent developments in the use of antigen-antibody interactions in conjunction with CE and conclude that continued development of miniaturization, on-line preconcentration and more sensitive detection schemes will contribute to the further dissemination of CE-based immunoassays building on already established affinity CE approaches.  相似文献   

4.
The study of the metabolomics of primary metabolites using conventional chemical analyses requires a high-throughput method. Chemical derivatizations are a prerequisite for gas-chromatographic separation, and a large sample quantity is needed for liquid-chromatographic separation and nuclear magnetic resonance detection systems. Recently, we have developed a capillary electrophoresis-mass spectrometry (CE-MS) technology that can simultaneously quantify a large number of primary metabolites, using only a small quantity of samples, and without any chemical derivatizations. Parallel use of a capillary electrophoresis-diode array detector (CE-DAD) system further enables almost all water-soluble intracellular metabolites to be analyzed. We demonstrate, with rice leaves, a simple and rapid method of sample preparation for CE analysis; using this method, we have successfully measured the levels of 88 main metabolites involved in glycolysis, the tricarboxylic acid cycle, the pentose phosphate pathway, photorespiration, and amino acid biosynthesis.  相似文献   

5.
The need for urgent diagnoses has propelled the development of automated analyses that can be performed in a short time at reasonable cost. One such method is immunoaffinity capillary electrophoresis. This emerging hybrid technology employs two powerful techniques coupled on-line for the direct and rapid determination of analytes present in biological fluids. The first technique, immunoaffinity, is used for the selective extraction of a molecule present in a complex matrix, utilizing a microscale-format chamber affinity device. An analyte (affinity target) present in serum or urine is captured by an immobilized molecular recognition antibody molecule (affinity ligand) bound to a solid support constituent (glass beads or an appropriate porous structure) of a microchamber affinity device. The second technique, capillary electrophoresis, is used for the high-resolution analytical separation of the purified and concentrated affinity target material after elution from the microchamber affinity device. In this work, immunoaffinity capillary electrophoresis was developed for the identification and characterization of a single constituent of a complex matrix. Immunoreactive gonadotropin-releasing hormone was determined in serum and urine specimens derived from a normal individual and from a patient suffering from benign prostatic hyperplasia. Furthermore, the on-line immuno-separation system was coupled in tandem to mass spectrometry to obtain molecular mass information of the affinity isolated and CE separated neuropeptide. This hybrid immuno-analytical technology is simple, rapid, selective and sensitive. In addition, an attempt was also made to characterize other urinary constituents by CE–MS that may lead to marker activity in the urine of the diseased subject. The hyphenation of analytical techniques has proved valuable in enhancing their individual features. The future of bioanalysis using miniaturized affinity systems is discussed in this paper.  相似文献   

6.
Multiwavelength detection of laser induced fluorescence for dideoxynucleotide DNA sequencing with four different fluorophores and separation by capillary gel electrophoresis is described. A cryogenically cooled, low readout noise, 2-dimensional charge-coupled device is used as a detector for the on-line, on-column recording of emission spectra. The detection system has no moving parts and provides wavelength selectivity on a single detector device. The detection limit of fluorescently labeled oligonucleotides meets the high sensitivity requirements for capillary DNA sequencing largely due to the efficient operation of the CCD detector with a 94% duty cycle. Using the condition number as a selectivity criterion, multiwavelength detection provides better analytical selectivity than detection with four bandpass filters. Monte Carlo studies and analytical estimates show that base assignment errors are reduced with peak identification based on entire emission spectra. High-speed separation of sequencing samples and the treatment of the 2-dimensional electropherogram data is presented. Comparing the DNA sequence of a sample separated by slab gel electrophoresis with sequence from capillary gel electrophoresis and multiwavelength detection we find no significant difference in the amount of error attributable to the instrumentation.  相似文献   

7.
We attempted an analysis of naturally occurring polyprenol and dolichol using a monolithic silica capillary column in HPLC. First, the separation of the polyprenol mixture alone was performed using a 250 x 0.2 mm inner diameter (ID) octadecylsilyl (ODS)-monolithic silica capillary column. The resolution of the separation between octadecaprenol (prenol 18) and nonadecaprenol (prenol 19) exceeded by >or=2-fold the level recorded when using a conventional ODS-silica particle-packed column (250 x 4.6 mm ID) under the same elution conditions. Next, the mixture of the prenol type (polyprenol) and dolichol type (dihydropolyprenol) was subjected to this capillary HPLC system, and the separation of each homolog was successfully achieved. During the analysis of polyprenol fraction derived from Eucommia ulmoides leaves, dolichols were found as a single peak, including all-trans-polyprenol and cis-polyprenol previously identified. This sensitive high-resolution system is very useful for the analysis of compounds that are structurally close to polyprenols and dolichols and that have a low content.  相似文献   

8.
A fast and sensitive analytical method was developed to characterize artemether and its metabolites in small amounts in body fluids. The extracts were derivatized with N-methyl-N-trimethylsilyltrifluoroacetamide, separated on an optimized capillary gas chromatographic system and identified by chemical ionization mass spectrometry by using ammonia as reagent gas. The analytical assay is demonstrated on samples extracted from bovine hemoglobin, rat blood and dog blood. Full mass spectra of artemether and three metabolites were obtained at a level of 1·10−6 g/ml.  相似文献   

9.
This review briefly summarizes recent progress in fundamental understanding and analytical profiling of the L-arginine/nitric oxide (NO) pathway. It focuses on key analytical references of NO actions and the experimental acquisition of these references in vivo, with capillary electrophoresis (CE) and high-performance capillary electrophoresis (HPCE) comprising one of the most flexible and technologically promising analytical platform for comprehensive high-resolution profiling of NO-related metabolites. Another aim of this review is to express demands and bridge efforts of experimental biologists, medical professionals and chemical analysis-oriented scientists who strive to understand evolution and physiological roles of NO and to develop analytical methods for use in biology and medicine.  相似文献   

10.
Sensitive capillary electrophoresis (CE) methods are required for emerging areas of biochemical research such as the metabolome. In this report, dynamic pH junction-sweeping CE with laser-induced fluorescence (LIF) detection is applied as a robust single method to analyze trace amounts of three flavin derivatives, riboflavin, flavin mononucleotide (FMN), and flavin adenine dinucleotide (FAD), from several types of samples including bacterial cell extracts, recombinant protein, and biological fluids. Submicromolar amounts of flavin coenzymes were measured directly from formic acid cell extracts of Bacillus subtilis. Significant differences in flavin concentration were measured in cell extracts derived from either glucose or malate as the carbon source in the culture media. Quantitative assessment of FAD and FMN content from selected flavoenzymes was demonstrated after heat denaturation to release noncovalently bound coenzymes and deproteinization. This method was also applied to the analysis of free flavins in pooled human plasma and urine without the need for laborious off-line sample preconcentration. Picomolar detectability of flavins by CE-LIF detection was realized with on-line preconcentration (up to 15% capillary length used for injection) by dynamic pH junction-sweeping, resulting in a limit of detection (S/N = 3) of about 4.0 pM for FAD and FMN. This represents over a 60-fold improvement in concentration sensitivity compared to those of previous techniques using conventional injections. The method was validated in terms of reproducibility, sensitivity, linearity, and specificity. Flavin analysis by dynamic pH junction-sweeping CE-LIF offers a simple, yet sensitive way to analyze trace levels of flavin metabolites from complex biological samples.  相似文献   

11.
An integrated system with a nano-reactor for cycle-sequencing reaction coupled to on-line purification and capillary gel electrophoresis has been demonstrated. Fifty nanoliters of reagent solution, which includes dye-labeled terminators, polymerase, BSA and template, was aspirated and mixed with the template inside the nano-reactor followed by cycle-sequencing reaction. The reaction products were then purified by a size-exclusion chromatographic column operated at 50°C followed by room temperature on-line injection of the DNA fragments into a capillary for gel electrophoresis. Over 450 bases of DNA can be separated and identified. As little as 25 nl reagent solution can be used for the cycle-sequencing reaction with a slightly shorter read length. Significant savings on reagent cost is achieved because the remaining stock solution can be reused without contamination. The steps of cycle sequencing, on-line purification, injection, DNA separation, capillary regeneration, gel-filling and fluidic manipulation were performed with complete automation. This system can be readily multiplexed for high-throughput DNA sequencing or PCR analysis directly from templates or even biological materials.  相似文献   

12.
Glycolysis and Krebs cycle intermediates were incubated with Eu3+-tetracycline and separated using capillary electrophoresis utilizing post-column laser-induced luminescence detection in a sheath flow cuvette. 3-phopshoglycerate, phosphoenolpyruvate, adenosine diphosphate, phosphate, citrate and oxaloacetate were detected at a concentration of 100 μM or lower. When all these detected metabolites were contained within the same sample it was found that they interfered with one another. Of all the metabolites, oxaloacetate showed the highest detectability. The system was found to yield a linear response for oxaloacetate from 50 nM to 10 μM. The injected volume of sample was 400 pL. This corresponds to 2 × 10?17 mol of injected oxaloacetate from the 50 nM sample. As an application, the system was used to assay the enzyme aspartate aminotransferase, for whom oxaloacetate is a product. After a 1 h incubation period, 1.2 × 10?13 M (3.3 μU/mL) enzyme was sufficient to form a detectable product signal. Extension of this incubation to 18 h permitted the detection of the activity of 1.2 × 10?14 M (330 nU/mL) enzyme. This is the equivalent of 4.8 ymoles (2.9 molecules) of enzyme in the 400 pL injection volume. The enzyme’s catalytic rate was determined to be 240 s?1 under the conditions used. In a second application, homogenates of Drosophila melanogaster were analyzed for metabolites, providing several peaks, including one which had the same retention time as citrate.  相似文献   

13.
A double-vented serial tetraphasic capillary column approach is applied to proteomic MuDPIT-type analysis using extended length capillary reverse-phase columns. The heart of the tetraphasic device consists of a triphasic MuDPIT trap located upstream of a venting tee. The trap is followed by a 60 cm high-resolution capillary column. A conventional high-flow HPLC is used to develop gradients at standard flow rates and pressures. The double-vented triphasic MuDPIT trapping device relieves the capillary separation column from the salt burden during the on-line cation-exchange portion of the analysis. Two configurations are presented, a double-vented continuous column model and a discontinuous model in which the triphasic MuDPIT trap is installed on a six-port valve; both configurations were tested with 60 and 10 cm capillary columns. All four systems were challenged with a trypsin digest of undepleted human serum, and a matrix of proteomic results for the different models and column lengths are compared.  相似文献   

14.
This report demonstrates the potential of on-line immunoaffinity extraction and coupled column packed capillary liquid chromatography-ion spray tandem mass spectrometry for multi-residue determination of five β-agonists, clenbuterol, mabuterol, mapenterol, methylclenbuterol, and tolubuterol, in bovine urine using an automated column switching system. Trace enrichment and preliminary sample cleanup was performed on-line using bovine urine diluted with phosphate-buffered saline. The column switching process involves trapping the target analytes onto a mini-bore immunoaffinity column, whereupon the target analytes are released from the immunoaffinity column onto a trapping column and subsequently eluted onto a packed capillary analytical column. The latter packed capillary column was used to provide the optimum sensitivity for ion spray LC-MS-MS analyses. The three-column system consists of a 2.0 mm I.D. immunoaffinity column, a 1 mm I.D. reversed-phase trapping column and a 320 μm I.D. packed capillary analytical column. Both qualitative and quantitative results are presented for the multi-residue determination of the target β-agonists from the complex urinary matrix. Using tolubuterol as an internal standard, the quantitative data showed good linear response within the concentration ranges studied. Lower levels of quantitation were 50 part per trillion (ppt) for clenbuterol and methylclenbuterol, 20 ppt for mabuterol and 10 ppt for mapenterol. The bovine renal elimination is described using the technique for one of the β-agonists, clenbuterol. The concentration of clenbuterol was detectable 15 days after the cessation of oral administration.  相似文献   

15.
Methods for the assay of nicotinic acid (NiAc) and its metabolites in biological fluids using high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) are reviewed. Most of the references cited in this review concern HPLC methods. A few CE methods that have been recently reported are also included. As these compounds are relatively polar and have a wide range of physico-chemical properties, the sample pre-treatment or clean-up process prior to analysis is included. Most HPLC methods using an isocratic elution system allow determination of a single or few metabolites, but gradient HPLC methods enable simultaneous determination of five to eight compounds. Simultaneous determination of NiAc including many metabolites in a single run can be achieved by CE. We also discuss the pharmacokinetics of NiAc and some of its metabolites.  相似文献   

16.
1. The purification to homogeneity of stable highly active preparations of UDP-glucuronyltransferase from liver of phenobarbital-treated rats is briefly described. 2. A single polypeptide was visible after sodium dodecyl sulphate/polyacrylamide-gel electrophoresis, of mol.wt.57000. 3. Antiserum raised against the pure enzyme produces a single sharp precipitin line after Ouchterlony double-diffusion analysis. 4. The pure UDP-glucuronyltransferase isolated from livers of untreated and phenobarbital-pretreated rats appears to be the same enzyme. 5. The Km (UDP-glucuronic acid) of the pure enzyme is 5.4 mM. 6. The activity of the pure enzyme towards 2-aminophenol can still be activated 2-3-fold by diethylnitrosamine. 7. UDP-glucose and UDP-galacturonic acid are not substrates for the purified enzyme. 8. The final preparation catalysed the glucuronidation of 4-nitrophenol, 1-naphthol, 2-aminophenol, morphine and 2-aminobenzoate. 9. Activities towards 4-nitrophenol, 1-naphthol and 2-aminophenol were all copurified. The proposed heterogeneity of UDP-glucuronyltransferase is discussed.  相似文献   

17.
Concentrations of inorganic anions, both as individual species and biotransformation products, in physiological fluids are of strong concern in clinical studies. To date, analytical methodologies have either required different analytical procedures to determine these analytes in plasma and urine, or extensive sample preparation, or unconventional and often expensive detection schemes, or both. A simple and sensitive capillary electrophoresis (CE) method with direct UV detection was developed for the simultaneous determination of iodide, bromide and nitrate in human plasma and urine, with a special focus on reliable quantification of the trace serum iodide. With the latter objective, the method incorporates a transient isotachophoresis (tITP) procedure enabling an efficient on-line preconcentration of iodide (limit of detection, 1.4 microg l(-1)) as well as other moderately mobile analytes that fall into the tITP range. The analyses of both types of biofluids were performed using an acidic electrolyte system composed of 0.25 mol l(-1) sodium chloride and 7.5 mmol l(-1) cetyltrimethylammonium chloride at pH 2.2 and 0.5 mol l(-1) 2-(N-morpholino)ethanesulfonate (pH 6.0) as terminating electrolyte. Relative standard deviations (R.S.D.) below 3.0% and 9.2% were obtained for within-day and between-day precision, respectively. Resolution and quantification of oxalic acid was also feasible under optimized tITP-CE conditions. Sample preparation required only ultrafiltration (serum) and dilution (urine). A number of plasma and urine samples were evaluated with this assay and the iodide, bromide and nitrate concentrations were in the expected clinical concentration ranges.  相似文献   

18.
For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.  相似文献   

19.
In this study a fused-silica capillary treated internally with a polyamine coating which reverses electroosmotic flow in the direction of the anode was evaluated for its ability to resolve metallothionein (MT) isoforms. Analysis of different MTs purified from liver and kidney tissue revealed the following numbers of putative isoform peaks resolved: rabbit (3–6); horse (3–5); rat (2–3), chicken (1); human MT-1 (5–6); sheep (4–5) and pig (4–5). The greater degree of MT isoform heterogeneity detected in this study using the polyamine-coated capillary suggested a higher resolving capacity for capillary zone electrophoresis conducted with this capillary compared to an uncoated one. Using the single isoform of chicken MT (cMT) as a reference standard, relative standard deviations of 2.53, 1.85 and 2.21% for peak migration time, area and height, respectively, were observed for eight consecutive runs. A standard curve for cMT established linearity (r2 = 0.99) for integrated peak area over three log units of cMT concentration with a lower limit of detection estimated to be 5 μg/ml. Acetonitrile extracts of chick liver tissue homogenates were successfully analyzed for the presence of MT isoforms from both control and zinc-injected animals. Based on our initial evaluation, capillary zone electrophoresis using the polyamine-coated capillary appears to be a very useful analytical method for the separation and quantification of individual MT isoforms.  相似文献   

20.
The combination of capillary isotachophoresis and capillary zone electrophoresis may enhance greatly the performance of analytical capillary electrophoresis with respect to both separation power and the concentration sensitivity. The concentrating effects and the separation power of isotachophoresis allow the analysis of diluted samples and the elimination of interferences due to bulk components. The separation process of zone electrophoresis enables one to resolve the stack of trace analytes and detect the resulting individual zones with high sensitivity. The transition of isotachophoresis into zone electrophoresis plays the key role in the overall performance of this hyphenated technique. This article describes the dynamics of the conversion of isotachophoresis into zone electrophoretic mode and shows that the key role is played by the segments of the leading and terminating zones from the isotachophoretic stage. The magnitude of these segments directly effects the detection time as well as the separation width of the peaks of analytes. It is shown that these effects are also important in the analyses by capillary zone electrophoresis where isotachophoresis is induced by the sample itself. Finally, the paper presents a list of recommended, user-friendly, electrolyte systems which enable one to simply predict the performance of the combination isotachophoresis-zone electrophoresis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号