首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of this study is to explore the prevalence of hepatitis C virus (HCV) infection among injection drug users (IDUs) with and without human immunodeficiency virus (HIV) infection in southern Taiwan. For 562 IDUs (265 anti-HIV negative, 297 anti-HIV positive), we analyzed liver function, anti-HIV antibody, anti-HCV antibody, HCV viral loads, and hepatitis B surface antigen (HBsAg). HIV RNA viral loads and CD4 cell count for anti-HIV-seropositive IDUs and the HCV genotype for HCV RNA-seropositive IDUs were measured. The seroprevalence rates of anti-HIV, anti-HCV, and HBsAg were 52.8%, 91.3%, and 15.3%, respectively. All the anti-HIV-seropositive IDUs were positive for HIV RNA. Anti-HCV seropositivity was the most important factor associated with HIV infection (odds ratio [OR], 25.06; 95% confidence intervals [CI], 8.97–74.9), followed by male gender (OR, 6.12; 95% CI, 4.05–9.39) and HBsAg seropositivity (OR, 1.90; 95% CI, 1.11–3.34). Among IDUs positive for anti-HCV, 80.7% had detectable HCV RNA. HCV viremia after HCV exposure was strongly related to HIV infection (OR, 6.262; 95% CI, 1.515–18.28), but negatively correlated to HBsAg seropositivity (OR, 0.161; 95% CI, 0.082–0.317). HCV genotype 6 was the most prevalent genotype among all IDUs (41.0%), followed by genotypes 1 (32.3%), 3 (12.8%), and 2 (5.6%). In conclusion, about half IDUs were infected with HIV and >90% with HCV infection. Male and seropositivity for HBsAg and anti-HCV were factors related to HIV infection among our IDUs. HIV was positively correlated, whereas hepatitis B co-infection was negatively correlated with HCV viremia among IDUs with HCV exposure. Different HCV molecular epidemiology was noted among IDUs.  相似文献   

2.
目的对兰州生物制品研究所有限责任公司研制的鼠疫菌F1抗体酶联免疫诊断试剂盒和鼠疫菌F1抗原酶联免疫诊断试剂盒进行临床应用评价。方法采用双抗原/抗体夹心酶联免疫吸附试验(ELISA)、间接血球凝集试验(IHA)、胶体金免疫层析试验(GICA)3种方法的诊断试剂对比检测云南省地方病防治所中心实验室保藏的和现场采集的血清样品和脏器样品,对血清样品做鼠疫菌F1抗体检测,对脏器样品做鼠疫菌F1抗原检测。结果在358份血清样品中,ELISA试剂检出F1抗体阳性52份(14.52%),IHA试剂检出阳性37份(10.34%),GICA试剂检出阳性45份(12.57%)。ELISA与IHA试剂的符合率为95.23%,与GICA试剂的符合率为96.92%。经统计学χ2检验,ELISA试剂检出F1抗体阳性率高于IHA试剂(χ2=11.53,P=0.000 7),与GICA试剂检出的差异无统计学意义(χ2=3.27,P=0.070 4)。进一步分析滴度差值频数,ELISA试剂检测人血清的敏感性高于IHA试剂的样品占87.5%。在117份脏器样品中,3种试剂均检出F1抗原阳性15份(12.82%),符合率100%。滴度差值频数比较,ELISA试剂检测敏感性高于反向间接血球凝集试验(RIHA)试剂的样品为78.57%。结论兰州生物制品研究所有限责任公司研制的鼠疫菌F1抗体酶联免疫诊断试剂盒和鼠疫菌F1抗原酶联免疫诊断试剂盒性质特异,其敏感性优于IHA试剂盒和GICA试剂条,值得在鼠疫的监测和快速诊断中推广应用。  相似文献   

3.
Cao J  Chen Q  Zhang H  Qi P  Liu C  Yang X  Wang N  Qian B  Wang J  Jiang S  Yang H  Sun S  Pan W 《PloS one》2011,6(4):e18477
Detection of specific antibodies against hepatitis C virus (HCV) is the most widely available test for viral diagnosis and monitoring of HCV infections. However, narrowing the serologic window of anti-HCV detection by enhancing anti-HCV IgM detection has remained to be a problem. Herein, we used LD5, a novel evolved immunoglobulin-binding molecule (NEIBM) with a high affinity for IgM, to develop a new anti-HCV enzyme-linked immunosorbent assay (ELISA) using horseradish peroxidase-labeled LD5 (HRP-LD5) as the conjugated enzyme complex. The HRP-LD5 assay showed detection efficacy that is comparable with two kinds of domestic diagnostic kits and the Abbott 3.0 kit when tested against the national reference panel. Moreover, the HRP-LD5 assay showed a higher detection rate (55.9%, 95% confidence intervals (95% CI) 0.489, 0.629) than that of a domestic diagnostic ELISA kit (Chang Zheng) (53.3%, 95% CI 0.463, 0.603) in 195 hemodialysis patient serum samples. Five serum samples that were positive using the HRP-LD5 assay and negative with the conventional anti-HCV diagnostic ELISA kits were all positive for HCV RNA, and 4 of them had detectable antibodies when tested with the established anti-HCV IgM assay. An IgM confirmation study revealed the IgM reaction nature of these five serum samples. These results demonstrate that HRP-LD5 improved anti-HCV detection by enhancing the detection of anti-HCV IgM, which may have potential value for the early diagnosis and screening of hepatitis C and other infectious diseases.  相似文献   

4.
M Louie  D E Low  S V Feinman  B McLaughlin  A E Simor 《CMAJ》1992,146(8):1331-1334
OBJECTIVE: To determine the prevalence rates of hepatitis B surface antigen (HBsAg) and antibodies to the human immunodeficiency virus (anti-HIV) and the hepatitis C virus (anti-HCV) among people admitted to an urban Canadian hospital. DESIGN: Anonymous unlinked serosurvey. SETTING: A 420-bed teaching hospital in Toronto. PARTICIPANTS: All 3000 patients admitted to the hospital on weekdays from January to June 1990. An attempt was made to exclude those who were readmitted during the study period. INTERVENTIONS: Serum samples from all the patients were tested for HBsAg and anti-HIV, and 1306 samples were also tested for anti-HCV by means of enzyme immunosorbent assays; reactions were confirmed by means of specific antibody neutralization or immunoblot assay. MAIN RESULTS: The prevalence rates of HBsAg, anti-HIV and anti-HCV were 2.1% (95% confidence interval [CI] 1.6% to 2.6%), 0.6% (95% CI 0.3% to 0.9%) and 0.5% (95% CI 0.1% to 0.9%) respectively. CONCLUSIONS: This is the first report defining rates of infection with these bloodborne agents among patients admitted to a Canadian hospital. The observed rates likely reflect the patient population served by our hospital and do not necessarily apply to other Canadian centres. The results support the use of universal precautions in health care settings.  相似文献   

5.
The Binax and the Biotest urinary antigen kits for detection of L. pneumophila antigen were compared by testing of selected 67 urine samples obtained from EWGLI as reference samples in External Quality Assessment Scheme. Thirty nine were positive with the Binax kit (100% of sensitivity), and 33 were positive with the Biotest (84.6% of sensitivity). The test specificities were 100% for the both kits. It was concluded that the Binax kit was more suitable for the routine diagnosis of Legionella infections than the Biotest kit.  相似文献   

6.
Donors screened by medical social history interview negative for high risk behavior or communicable disease history, but subsequently exhibiting reactive serological markers, emphasize importance of duel safe guarding factors for determining donor suitability. This report examines a relationship between two immunoabsorption assay tests, hepatitis B core (HBc) antibody, a required food and drug administration (FDA) test, and hepatitis B antibody (anti HBs), non-required test. Reactive serology results, 129 cases, 3,581 donors (2008–2012) for HBc as the only initially positive serological marker were subjected to anti HBs testing in this history pre-screened donor population. Enzyme linked immunoabsorption assay kits hepatitis B, core and antibody, were used in this study. All samples were initially tested for human immunodeficiency virus, hepatitis B, and hepatitis C, utilizing nucleic acid testing and antigen antibody immunoabsorption assay. Testing was performed by a FDA-registered CLEA-certified reference laboratory. Samples were deceased donor blood samples and a limited number of pre-mortem samples, separated, stored and analyzed according to manufacturer recommendation and FDA regulations. 129 reactive HBc only samples, were subsequently tested for anti HBs. Of these 129, 94 were found to be reactive for anti HBs. This represented 72 % of samples tested for antibody, a higher percentage than anticipated for a medical history negative, low risk population.  相似文献   

7.
8.
In testing for antibodies to the hepatitis C virus (anti-HCV) in 112 patients with primary hepatocellular carcinoma, 10 of 33 white patients (30%) and 15 of 79 Asian patients (19%) had a positive response to the antibody. The antibody profile to individual hepatitis C viral antigens and the presence of circulating hepatitis C viral RNA were determined in the 25 patients. The anti-HCV antibodies most frequently detected were toward the antigens from the core (C22) and NS3 regions. Serum hepatitis C viral RNA was present in 17 of the 25 patients (68%), and these patients tended to have serum levels of alanine and aspartate aminotransferases higher than those patients without viremia (136 +/- 22 U per liter versus 64 +/- 11 U per liter and 161 +/- 26 U per liter versus 79 +/- 14 U per liter, respectively, both P < .05). Of the 15 Asian patients with hepatocellular carcinoma and anti-HCV, 4 (27%) had coexisting hepatitis B surface antigen (HBsAg) and 13 (87%) had antibodies to either hepatitis B core or surface antigen. Of the 10 white patients with anti-HCV, however, only 1 (10%) had hepatitis B virus antibodies (P < .01). Among 4 Asian patients with coexisting anti-HCV and HBsAg, 1 was found to have serum hepatitis B viral DNA and the other 3 had hepatitis C viral RNA. A history of blood transfusion was obtained from 12 of the 25 patients with anti-HCV (48%); 20 (80%) had coexisting cirrhosis. Our findings support the hypothesis that hepatitis C virus is an important etiologic agent in the development of primary hepatocellular carcinoma in both white and Asian patients in the United States.  相似文献   

9.
用中国药品生物制品检定所检定合格的国内外HBsAgEIA试剂及ABBOTT抗 HBs、抗 HBcEIA试剂 ,对所收集的 13份HBsAg疑难判定血清进行检测 ,并用PCR方法检测血清中HBVDNA ,结果显示国内外HBsAg试剂对部分HBVDNA阳性样品的检出率差异较大 ,提示这些样品可能为S基因突变株或HBsAg含量较低 ,因此 ,HBsAgEIA试剂的敏感度仍有待进一步提高 ,并应进一步研制检测S基因突变株的HBsAg诊断试剂。  相似文献   

10.
A method to detect major serotypes of foot-and-mouth disease virus   总被引:1,自引:0,他引:1  
Nucleic acid sequence-based amplification (NASBA) is an isothermal technique that allows the rapid amplification of specific regions of nucleic acid obtained from a diverse range of sources. It is especially suitable for amplifying RNA sequences. A rapid and specific NASBA technique was developed, allowing the detection of foot-and-mouth disease virus genetic material in a range of sample material, including preserved skin biopsy material from infected animals, vaccines prepared from denatured cell-free material, and cell-free antigen-based detection kits. A single pair of DNA oligonucleotide primers was able to amplify examples of all major FMD virus subtypes. The amplified viral RNA was detected by electrochemiluminescence. The method was at least as sensitive as existing cell-free antigen detection methods.  相似文献   

11.
This study evaluated five commercial extraction kits for their ability to recover DNA from Bacillus anthracis spores and spiked environmental samples. The kits evaluated represent the major types of methodologies which are commercially available for DNA or total nucleic acid extraction, and included the ChargeSwitch gDNA Mini Bacteria Kit, NucliSens Isolation Kit, Puregene Genomic DNA Purification Kit, QIAamp DNA Blood Mini Kit, and the UltraClean Microbial DNA Isolation Kit. Extraction methods were performed using the spores of eight virulent strains of B. anthracis. Viability testing of nucleic acid extracts showed that the UltraClean kit was the most efficient at depleting samples of live B. anthracis spores. TaqMan real-time PCR analysis revealed that the NucliSens, QIAamp and UltraClean kits yielded the best level of detection from spore suspensions. Comparisons of processed samples from spiked swabs and three powder types indicated that DNA extraction using the UltraClean kit resulted in the most consistently positive results and the lowest limit of detection. This study demonstrated that different nucleic extraction methodologies, represented here by various commercial extraction kits, differ in their ability to inactivate live B. anthracis spores as well as DNA yield and purity. In addition, the extraction method used can influence the sensitivity of real-time PCR assays for B. anthracis.  相似文献   

12.
Serum samples were assayed using radioimmunoassay in 573 Vietnamese blood donors living in Hano? (North Viet Nam). 66 (11.5%) subjects were HBsAg-positive. Of these 66 HBsAg carriers, 17 (25,8%) were positive for hepatitis B e antigen (HBeAg) and 43 (65.1%) for antibody to HBeAg (anti-HBe). 22 (3.8%) subjects were positive for antibody to hepatitis B core antigen (anti-HBc) alone. 402 (70.2%) subjects were positive for antibody to HBsAg (anti-HBs). This anti-HBs percentage increased with age. Only 83 (14.5%) subjects were negative for all hepatitis B viral (HBV) markers. This no HBV markers percentage decreased with age. The chi 2 test showed a non significant difference for frequencies of HBsAg, anti-HBc alone, anti-HBs but a significant one for frequencies of no HBV markers in men and women.  相似文献   

13.
Control sera are an essential component of in-vitro clinical diagnostic reagents. We have developed a control serum for HBsAg, anti-HCV, anti-HIV and anti- Treponema pallidum testing. Since this control serum is prepared from human plasma, we paid special attention to viral safety. We incorporated three viral inactivation methods into the manufacturing process that maintain the necessary characteristics of a stable control serum.  相似文献   

14.

Objectives

To assess HCV viremia levels just before, during and one year after anti-HCV seroconversion in people who inject drugs (PWID).

Methods

PWID enrolling into a needle exchange program in Malmö, Sweden, 1997–2005 constituted the source population. Sera were obtained at enrolment and at approximately 3–4 monthly intervals afterwards, and were initially tested for anti-HIV, HBsAg/anti-HBc and anti-HCV and thereafter for markers previously negative. Seroconversion to anti-HCV had occurred during the study period in 186 out of 332 seronegative subjects. In these anti-HCV seroconverters, quantitative HCV RNA PCR was retrospectively performed on frozen sera to determine viremia levels in the last anti-HCV negative, the first anti-HCV positive and in one year follow-up samples.

Results

Among 150 subjects seroconverting to anti-HCV with samples available from all three defined time-points, eight different patterns of viremia were observed. Spontaneous clearance at one year was noted in 48 cases (32%) and was associated with female gender (p = 0.03, CI 0.17–1.00). In 13 cases HCV-RNA was not detected in any study sample. Among 61 subjects with pre-seroconversion viremia, viral load was significantly higher in the pre-seroconversion samples compared to subsequent samples. For the whole group, viral load declined to undetectable levels at seroconversion in 28% of cases (but with recurrent viremia in 15%).

Conclusions

Different patterns of HCV RNA kinetics were observed among PWID with documented seroconversion to anti-HCV. The frequently observed absence of detectable HCV RNA in the first anti-HCV positive sample (irrespective of subsequent viremia) demonstrates the importance of repeated sampling and RNA testing for determination of the outcome of acute infection.  相似文献   

15.
16.
Two variants of sandwich-type ELISA (Enzyme Linked Immunosorbent Assay) kits for HBsAg detection (Sevatest ELISA HBsAg Macro I and Sevatest ELISA HBsAg Micro I) in human sera and plasmas were developed. As the solid phase, the ELISA Macro kit and ELISA Micro kit make use of polystyrene microtubes, and polystyrene microtitration plates, respectively, of Czechoslovak production (Koh-i-noor, Dalecín). Capture anti HBs antibody for adsorption to solid phase and rabbit anti HBs antibody for labelling with horse-radish peroxidase were prepared for both tests. The sensitivity of both ELISA kits for HBsAg, equal to approx. 2 ng/ml, was determined by titrating six selected HBsAg-positive sera and the WHO Agk 76 panel of HBsAg-positive sera and the results were compared with those obtained by ELISA, RIA (Radioimmunoassay) and RPHA (Reverse passive hemagglutination) kits of different producers and by counter-immunoelectrophoresis (CIEP). The sensitivity of the new ELISA kits was comparable to that of other producers' ELISA kits, higher than that of RPHA kits and only a little lower than that of RIA kits. A set of sera of patients hospitalised with different diagnoses was tested for HBsAg. The detection rate by ELISA Macro kit 2.8 and 1.5 times higher than by CIEP and RPHA (Raphadex B), respectively, and 1.1 time lower than by RIA (Austria II).  相似文献   

17.
18.
Phage display technology has been utilized for identification of specific binding molecules to an antigenic target thereby enabling the rapid generation and selection of high affinity, fully human antibodies directed towards disease target appropriate for antibody therapy. In the present study, single chain Fv antibody fragment (scFv) to hepatitis A virus (HAV) was selected from phage displayed antibody library constructed from peripheral blood lymphocytes (PBLs) of a vaccinated donor. The variable heavy (V(H)) and light chains (V(L)) were amplified using cDNA as template, assembled into scFv using splicing by overlap extension PCR (SOE PCR) and cloned into phagemid vector as a fusion for display of scFv on bacteriophage. The phage displaying antibody fragments were subjected to three rounds of panning with HAV antigen on solid phase. High affinity antibodies reactive to hepatitis A virus were identified by phage ELISA and cloned into a bacterial expression vector pET20b. The scFv was purified by immobilized metal affinity chromatography (IMAC) on a nickel-nitrilotriacetic acid (NTA) agarose column and characterized. The binding activity and specificity of the scFv was established by its non-reactivity towards other human viral antigens as determined by ELISA and immunoblot analysis. The scFv was further used in the development of an in-house IC-ELISA format in combination with a commercially available mouse monoclonal antibody for the quantification of hepatitis A virus antigen in human vaccine preparations. The adjusted r2 values obtained by subjecting the values obtained by quantification of the NIBSC standards using the commercial and the in-house ELISA kits by regression analysis were 0.99 and 0.95. 39 vaccine samples were subjected to quantification using both the kits. Regressional statistical analysis through the origin of the samples indicated International Unit (IU) values of 0.0416x and 0.0419x, respectively for the commercial and in-house kit respectively.  相似文献   

19.
周杨 《微生物学通报》2017,44(8):1996-2004
【目的】评价基于环介导恒温扩增技术(LAMP)的大肠杆菌O157:H7(Escherichia coli O157:H7)快速检测试剂盒的实效性。【方法】测定快速检测试剂盒的特异性、灵敏度、重复性、保质期以及运输稳定性,并与传统方法对比检测实际样品。【结果】大肠杆菌O157:H7标准菌株样品均检测为阳性,非大肠杆菌O157:H7标准菌株样品均检测为阴性,未发现有交叉反应;试剂盒最低检验限为29 CFU;该试剂盒的特异性、灵敏度及准确度与传统方法相比具有较高的一致性;试剂盒对高菌量目标菌和阴性菌样品的检测重复率均为100%,对低菌量目标菌样品的批间检测重复率为94%。试剂盒可在4°C保存9个月以上,并且可进行变温储存72 h以上。【结论】该试剂盒特异性好,灵敏度高,重复性好,储存方便,检测结果稳定、可靠,适用于对食品中大肠杆菌O157:H7的检测需求。  相似文献   

20.
The passive hemagglutination test (Sero-Test CCB) for the detection of hepatitis B surface antigen (HBsAg) has been developed. The comparative study of the sensitivity of Sero-Test CCB, the passive hemagglutination test Hepanostikon (developed by Organon, the Netherlands) and the radioimmunoassay (with the use of an experimental assay kit provided by the Institute of Vaccines in Dessau, GDR) has been carried out by the determination of HBsAg in 100 coded sera from viral hepatitis patients and hepatitis virus carriers. Both passive hemagglutination tests (Sero-Test CCB and Hepanostikon) have yielded coinciding results (r = 0.90). The sensitivity of Sero-Test CCB has been found to exceed that achieved with the use of electrophoretic techniques 30-150 times, though it is 8 times lower than the sensitivity of the radioimmunoassay. The test kits Sero-Test CCB HBsAg are used for the examination of donor blood and for the survey of groups of persons subjected to a high risk of contacting hepatitis B infection in hemodialysis and transplantation centers, surgical wards, etc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号