1.
Keppler A  Arrivoli C  Sironi L  Ellenberg J 《BioTechniques》2006,41(2):167-70, 172, 174-5
O6-alkylguanine-DNA alkyltransferase (AGT) fusion proteins can be specifically and covalently labeled with fluorescent O6-benzylguanine (O6-BG) derivatives for multicolor live cell imaging approaches. Here, we characterize several new BG fluorophores suitable for in vivo AGT labeling that display fluorescence emission maxima covering the visible spectrum from 472 to 673 nm, thereby extending the spectral limits set by fluorescent proteins. We show that the photostability of the cell-permeable dyes BG Rhodamine Green (BG505) and CP tetramethylrhodamine (CP-TMR) is in the range of enhanced green fluorescent protein (EGFP) and monomeric red fluorescent protein (mRFP), and that BG diethylaminomethyl coumarin (BGDEAC), a derivative of coumarin, is even more stable than enhanced cyan fluorescent protein (ECFP). Due to the increasing number of new BG derivatives with interesting fluorescence properties, such as far-red emission, fluorescence labeling of AGT fusion proteins is becoming a versatile alternative to existing live cell imaging approaches.  相似文献   

2.
We describe a novel variant of fluorescence lifetime imaging microscopy (FLIM), denoted anisotropy-FLIM or rFLIM, which enables the wide-field measurement of the anisotropy decay of fluorophores on a pixel-by-pixel basis. We adapted existing frequency-domain FLIM technology for rFLIM by introducing linear polarizers in the excitation and emission paths. The phase delay and intensity ratios (AC and DC) between the polarized components of the fluorescence signal are recorded, leading to estimations of rotational correlation times and limiting anisotropies. Theory is developed that allows all the parameters of the hindered rotator model to be extracted from measurements carried out at a single modulation frequency. Two-dimensional image detection with a sensitive CCD camera provides wide-field imaging of dynamic depolarization with parallel interrogation of different compartments of a complex biological structure such as a cell. The concepts and technique of rFLIM are illustrated with a fluorophore-solvent (fluorescein-glycerol) system as a model for isotropic rotational dynamics and with bacteria expressing enhanced green fluorescent protein (EGFP) exhibiting depolarization due to homotransfer of electronic excitation energy (emFRET). The frequency-domain formalism was extended to cover the phenomenon of emFRET and yielded data consistent with a concentration depolarization mechanism resulting from the high intracellular concentration of EGFP. These investigations establish rFLIM as a powerful tool for cellular imaging based on rotational dynamics and molecular proximity.  相似文献   

3.
We investigate the potential of dual-color photon counting histogram (PCH) analysis to resolve fluorescent protein mixtures directly inside cells. Because of their small spectral overlap, we have chosen to look at the fluorescent proteins EGFP and mRFP1. We experimentally demonstrate that dual-color PCH quantitatively resolves a mixture of EGFP and mRFP1 in cells from a single measurement. To mimic the effect of protein association, we constructed a fusion protein of EGFP and mRFP1 (denoted EGFP-mRFP1). Fluorescence resonant energy transfer within the fusion protein alters the dual-channel brightness of the fluorophores. We describe a model for fluorescence resonant energy transfer effects on the brightness and incorporate it into dual-color PCH analysis. The model is verified using fluorescence lifetime measurements. Dual-color PCH analysis demonstrated that not all of the expressed EGFP-mRFP1 fusion proteins contained a fluorescent mRFP1 molecule. Fluorescence lifetime and emission spectra measurements confirmed this surprising result. Additional experiments show that the missing fluorescent fraction of mRFP1 is consistent with a dark state population of mRFP1. We successfully resolved this mixture of fusion proteins with a single dual-color PCH measurement. These results highlight the potential of dual-color PCH to directly detect and quantify protein mixtures in living cells.  相似文献   

4.
The green fluorescent protein (GFP) and its analogs are standard markers of protein expression and intracellular localization of proteins. The fluorescent properties of GFP complicate accurate measurement of intracellular calcium using calcium sensitive fluorophores, which show a great degree of spectral overlap with GFP, or their K(d) values are too high for accurate measurement of subtle changes in cytoplasmic calcium concentrations. Here we describe a simple modification of the standard microscope-based Fura-2 calcium-imaging technique which permits the quantitative measurement of intracellular calcium levels in cells expressing enhanced green fluorescent protein (EGFP) fusion proteins. Longpass emission filtering of the Fura-2 signal in cells expressing an EGFP fusion protein is sufficient to eliminate the EGFP-Fura-2 emission spectra overlap and allows quantitative calibration of intracellular calcium. To validate this technique, we investigated the ability of rotavirus enterotoxin NSP4-EGFP to elevate intracellular calcium levels in mammalian HEK 293 cells. We show here that inducible intracellular expression of NSP4-EGFP fusion protein elevates basal intracellular calcium more than two-fold by a phospholipase C (PLC) independent mechanism.  相似文献   

5.
In vivo fluorescence imaging uses a sensitive camera to detect fluorescence emission from fluorophores in whole-body living small animals. To overcome the photon attenuation in living tissue, fluorophores with long emission at the near-infrared (NIR) region are generally preferred, including widely used small indocarbocyanine dyes. The list of NIR probes continues to grow with the recent addition of fluorescent organic, inorganic and biological nanoparticles. Recent advances in imaging strategies and reporter techniques for in vivo fluorescence imaging include novel approaches to improve the specificity and affinity of the probes and to modulate and amplify the signal at target sites for enhanced sensitivity. Further emerging developments are aiming to achieve high-resolution, multimodality and lifetime-based in vivo fluorescence imaging.  相似文献   

6.
Dual-color fluorescence cross-correlation spectroscopy (FCCS) is a promising technique for quantifying protein-protein interactions. In this technique, two different fluorescent labels are excited and detected simultaneously within a common measurement volume. Difficulties in aligning two laser lines and emission crossover between the two fluorophores, however, make this technique complex. To overcome these limitations, we developed a fluorescent protein with a large Stokes shift. This protein, named Keima, absorbs and emits light maximally at 440 nm and 620 nm, respectively. Combining a monomeric version of Keima with cyan fluorescent protein allowed dual-color FCCS with a single 458-nm laser line and complete separation of the fluorescent protein emissions. This FCCS approach enabled sensitive detection of proteolysis by caspase-3 and the association of calmodulin with calmodulin-dependent enzymes. In addition, Keima and a spectral variant that emits maximally at 570 nm might facilitate simultaneous multicolor imaging with single-wavelength excitation.  相似文献   

7.
We have measured the fluorescence spectra of a single fluorophore attached to a single protein molecule in aqueous solution using a total internal reflection fluorescence microscope. The most reactive cysteine residue of myosin subfragment-1 (S1) was labeled with tetramethylrhodamine. The spectral shift induced by a change in solvent from aqueous buffer to methanol in both single-molecule and bulk measurements were similar, indicating that, even at the single molecule level, the fluorescence spectrum is sensitive to microenvironmental changes of fluorophores. The time dependence of the fluorescence spectra of fluorophores attached to S1 molecules solely showed a fluctuation with time over a time scale of seconds. Because the fluorescence spectra of the same fluorophores directly conjugated to a glass surface remained constant, the spectral fluctuation observed for the fluorophores attached to S1 is most likely due to slow spontaneous conformational changes in the S1 molecule. Thus, single-molecule fluorescence spectroscopy appears to be a powerful tool to study the dynamic behavior of single biomolecules.  相似文献   

8.
Fluorescence is typically isotropic in space and collected with low efficiency. In this paper we describe surface plasmon-coupled emission (SPCE), which displays unique optical properties and can be collected with an efficiency near 50%. SPCE occurs for fluorophores within about 200 nm of a thin metallic film, in our case a 50-nm-thick silver film on a glass substrate. We show that fluorophore proximity to this film converts the normally isotropic emission into highly directional emission through the glass substrate at a well-defined angle from the normal axis. Depending on the thickness of the polyvinyl alcohol (PVA) film on the silver, the coupling efficiency of sulforhodamine 101 in PVA ranged from 30 to 49%. Directional SPCE was observed whether the fluorophore was excited directly or by the evanescent field due to the surface plasmon resonance. The emission is always polarized perpendicular to the plane of incidence, irrespective of the polarization of the incident light. The lifetimes are not substantially changed, indicating a mechanism somewhat different from that observed previously for the effects of silver particles on fluorophores. Remarkably, the directional emission shows intrinsic spectral resolution because the coupling angles depend on wavelength. The distances over which SPCE occurs, 10 to 200 nm, are useful because a large number of fluorophores can be localized within this volume. The emission of more distant fluorophores does not couple into the glass, allowing background suppression from biological samples. SPCE can be expected to become rapidly useful in a variety of analytical and medical sensing applications.  相似文献   

9.
Wu B  Chen Y  Müller JD 《Biophysical journal》2006,91(7):2687-2698
We introduce dual-color time-integrated fluorescence cumulant analysis (TIFCA) to analyze fluorescence fluctuation spectroscopy data. Dual-color TIFCA utilizes the bivariate cumulants of the integrated fluorescent intensity from two detection channels to extract the brightness in each channel, the occupation number, and the diffusion time of fluorophores simultaneously. Detecting the fluorescence in two detector channels introduces the possibility of differentiating fluorophores based on their fluorescence spectrum. We derive an analytical expression for the bivariate factorial cumulants of photon counts for arbitrary sampling times. The statistical accuracy of each cumulant is described by its variance, which we calculate by the moments-of-moments technique. A method that takes nonideal detector effects such as dead-time and afterpulsing into account is developed and experimentally verified. We perform dual-color TIFCA analysis on simple dye solutions and a mixture of dyes to characterize the performance and accuracy of our theory. We demonstrate the robustness of dual-color TIFCA by measuring fluorescent proteins over a wide concentration range inside cells. Finally we demonstrate the sensitivity of dual-color TIFCA by resolving EGFP/EYFP binary mixtures in living cells with a single measurement.  相似文献   

10.
Steady-state fluorescence anisotropy measurements can be used to detect fluorescence resonance energy transfer (FRET) between identical fluorophores (homo-FRET). However, the contribution of homo-FRET to the steady-state anisotropy must be discerned from those due to the orientational distribution and rotational diffusion, which so far has required photobleaching controls, largely precluding dynamic measurements in live cells. We describe a variation of steady-state anisotropy microscopy in which the contribution of homo-FRET is dynamically isolated from the total anisotropy by exploiting the loss of energy transfer that occurs at red-edge excitation. Excitation of enhanced green fluorescent protein (EGFP) at the red-edge of its absorption band shows the shift in the emission spectrum compared to main-band excitation that is characteristic for photo-selection of static low energy S(0)-S(1) transitions that fail to exhibit FRET. An experimental setup for steady-state fluorescent anisotropy microscopy is described that can be used to acquire anisotropy images in live cells at main-band and red-edge excitation of EGFP. We demonstrate in live cells homo-FRET suppression of protein fusion constructs that consist of two and three EGFP molecules connected by short linkers. This methodology represents a novel approach for the dynamic measurement of homo-FRET in live cells that will be of utility in the biological sciences to detect oligomerization and concentration dependent interactions between identically labeled molecules.  相似文献   

11.
Fluorescence emission is nearly isotropic in space. With typical optical components the collection efficiency is 1% or less. In this preliminary report, we describe a novel approach to transforming the normally isotropic emission into directional emission with a collection efficiency near 50%. This can be accomplished for fluorophores located near a semi-transparent silver film on a glass substrate. The emission couples with the surface plasmon resonance on the silver surface and enters the transparent substrate at a sharply defined angle, the surface plasmon angle for the emission wavelength. We estimate that 40-70% of the total emission enters the substrate at the plasmon angle and can thus be directed towards a detector. Background emission from fluorophores distant from the silver does not couple with the plasmon and is not detected. Different emission wavelengths couple at different angles allowing spectral discrimination without additional optics. Surface plasmon-coupled emission represents a new technology which can be used for high detection efficiency with microfluidic and/or surface-bound assay formats.  相似文献   

12.
Dual-color imaging of acridine orange (AO) and EGFP fused to a vesicular glutamate transporter or the vesicle-associated membrane proteins 2 or 3 has been used to visualize a supposedly well-defined subpopulation of glutamatergic astrocytic secretory vesicles undergoing regulated exocytosis. However, AO metachromasy results in the concomitant emission of green and red fluorescence from AO-stained tissue. Therefore, the question arises whether AO and EGFP fluorescence can be distinguished reliably. We used evanescent-field imaging with spectral fluorescence detection as well as fluorescence lifetime imaging microscopy to demonstrate that green fluorescent AO monomers inevitably coexist with red fluorescing AO dimers, at the level of single astroglial vesicles. The green monomer emission spectrally overlaps with that of EGFP and produces a false apparent colocalization on dual-color images. On fluorophore abundance maps calculated from spectrally resolved and unmixed single-vesicle spectral image stacks, EGFP is obscured by the strong green monomer fluorescence, precluding the detection of EGFP. Hence, extreme caution is required when deriving quantitative colocalization information from images of dim fluorescing EGFP-tagged organelles colabeled with bright and broadly emitting dyes like AO. We finally introduce FM4-64/EGFP dual-color imaging as a remedy for imaging a distinct population of astroglial fusion-competent secretory vesicles.  相似文献   

13.
Fluorescence contributions from immobile sources present a challenge for fluorescence fluctuation spectroscopy (FFS) because the absence of signal fluctuations from stationary fluorophores leads to a biased analysis. This is especially of concern for cellular FFS studies on proteins that interact with immobile structures. Here we present a method that correctly analyzes FFS experiments in the presence of immobile sources by exploiting selective photobleaching of immobile fluorophores. The fluorescence decay due to photobleaching of the immobile species is modeled taking into account the nonuniform illumination volume. The experimentally observed decay curve serves to separate the mobile and immobile fluorescence contribution, which is used to calculate the molecular brightness from the FFS data. We experimentally verify this approach in vitro using the fluorescent protein EGFP as our immobilized species and a diffusing dye of a different color as the mobile one. For this special case, we also use an alternative method of determining the brightness by spectrally resolving the two species. By conducting a dilution study, we show that the correct parameters are obtained using either technique for a wide range of mobile fractions. To demonstrate the application of our technique in living cells, we perform experiments using the histone core protein H2B fused with EGFP expressed in COS-1 cells. We successfully recovered the brightness of the mobile fraction of H2B-EGFP.  相似文献   

14.
In the present communication we report a spectral analysis of the blue-green fluorescence related to changes in NAD(P) redox state in chloroplasts and leaves. To assess the contribution of reabsorption and the inner filter effect, we compared transmission and fluorescence at different chloroplast concentrations, and showed that reabsorption by the photosynthetic pigments (chlorophylls and carotenoids) was at the origin of the two peaks in the emission spectrum in vivo. The absence of potential green-emitting fluorophores in chloroplasts was determined by measuring variable and time-resolved fluorescence at different wavelengths. We defined the conditions which optimize the UV-excited blue-green fluorescence signal dependent on NAD(P)H, and we present an example of monitoring of NAD(P)H fluorescence in intact leaves.  相似文献   

15.
A new computational procedure to resolve the contribution of Photosystem I (PSI) and Photosystem II (PSII) to the leaf chlorophyll fluorescence emission spectra at room temperature has been developed. It is based on the Principal Component Analysis (PCA) of the leaf fluorescence emission spectra measured during the OI photochemical phase of fluorescence induction kinetics. During this phase, we can assume that only two spectral components are present, one of which is constant (PSI) and the other variable in intensity (PSII). Application of the PCA method to the measured fluorescence emission spectra of Ficus benjamina L. evidences that the temporal variation in the spectra can be ascribed to a single spectral component (the first principal component extracted by PCA), which can be considered to be a good approximation of the PSII fluorescence emission spectrum. The PSI fluorescence emission spectrum was deduced by difference between measured spectra and the first principal component. A single-band spectrum for the PSI fluorescence emission, peaked at about 735?nm, and a 2-band spectrum with maxima at 685 and 740?nm for the PSII were obtained. A linear combination of only these two spectral shapes produced a good fit for any measured emission spectrum of the leaf under investigation and can be used to obtain the fluorescence emission contributions of photosystems under different conditions. With the use of our approach, the dynamics of energy distribution between the two photosystems, such as state transition, can be monitored in vivo, directly at physiological temperatures. Separation of the PSI and PSII emission components can improve the understanding of the fluorescence signal changes induced by environmental factors or stress conditions on plants.  相似文献   

16.
Many questions in cell biology and biophysics involve the quantitation of co-localisation and the interaction of proteins tagged with different fluorophores. However, the incomplete separation of the different colour channels due to the presence of autofluorescence, along with cross-excitation and emission "bleed-through" of one colour channel into the other, all combine to render the interpretation of multi-band images ambiguous. Here we introduce a new live-cell epifluorescence spectral imaging and linear unmixing technique for classifying resolution-limited point objects containing multiple fluorophores. We demonstrate the performance of our technique by detecting, at the single-vesicle level, the co-expression of the vesicle-associated membrane protein, VAMP-2 (also called synaptobrevin-2), linked to either enhanced green fluorescent protein (EGFP) or citrine [a less pH-sensitive variant of enhanced yellow fluorescent protein (EYFP)], in mouse cortical astrocytes. In contrast, the co-expression of VAMP-2-citrine and the lysosomal transporter sialine fused to EGFP resulted in little overlap. Spectral imaging and linear unmixing permit us to fingerprint the expression of spectrally overlapping fluorescent proteins on single secretory organelles in the presence of a spectrally broad autofluorescence. Our technique provides a robust alternative to error-prone dual- or triple colour co-localisation studies.  相似文献   

17.
We examined the fluorescent spectral properties of fluorescein-labeled DNA oligomers when directly bound to metallic silver particles via a terminal sulfhydryl group. We found a 12-fold increase in fluorescence intensity and 25-fold decrease in lifetime for a fluorescein residue positioned 23 nucleotides from the silver surface compared to labeled oligomers in free solution. Similar results were found for a 23-mer labeled with five fluorescein residues. The absence of long lifetime components in the intensity decays suggests that all labeled oligomers are bound to silver and affected similarly by the metallic surfaces. These results provide the basic knowledge needed to begin use of metal-enhanced fluorescence for the detection of target sequences in simple formats potentially without a washing separation step. The use of metal-enhanced fluorescence provides a generic approach to obtaining a hybridization-dependent increase in fluorescence with most, if not all, commonly used fluorophores.  相似文献   

18.
In microarrays experiments, a serious limitation is the unreliability of low signal intensities data and the lack of reproducibility for the resulting ratios between samples and controls. Most of the light emitted by a fluorophore at the air/glass interface of a glass slide is absorbed by the glass so just a part of the emitted fluorescence is detected. To improve the sensitivity of the fluorescence detection of both common fluorophores Cy3 and Cy5 in DNA microarrays and fluorescent cell analyses, we have designed a multi layer mirror with alternative thin layers of SiO2 and HfO2. This mirror (MOTL) prevents fluorescence absorption, allows the simultaneous enhancement of the fluorescence signals and increases the dynamic range of the slides. Using MOTL slides, Cy3 and Cy5 intensities are enhanced by 5-8-fold, consequently, the fluorescence analysis becomes easier and should allow the detection of low copy number genes or weakly fluorescent cells. With the same approach, other multiple optical thin layer slides could be designed for other series of fluorophores, extending the field of their applications.  相似文献   

19.
The spectral curves of emission of paraform-induced fluorophores in small, intensely fluorescent (SIF) cells in lumbar ganglia of the sympathetic trunk and in the major pelvic ganglion were compared with the fluorescence spectra of lipofuscin granules in the perikaryons of the neurons of the vagus inferior ganglion. As a rule, the fluorescence spectra of SIF cells correlate with the content in them of catecholamines. The spectral characteristics of fluorophores of so-called "yellow" SIF cells have much in common with the fluorescence spectra of lipofuscin granules. Apparently, in some of cases small cells containing lipofuscin may be identified as "yellow" SIF cells.  相似文献   

20.
In vivo optical imaging to enhance the detection of cancer during endoscopy or surgery requires a targeted fluorescent probe with high emission efficiency and high signal-to-background ratio. One strategy to accurately detect cancers is to have the fluorophore internalize within the cancer cells permitting nonbound fluorophores to be washed away or absorbed. The choice of fluorophores for this task must be carefully considered. For depth of penetration, near-infrared probes are ordinarily preferred but suffer from relatively low quantum efficiency. Although green fluorescent protein has been widely used to image tumors on internal organs in mice, green fluorescent probes are better suited for imaging the superficial tissues because of the short penetration distance of green light in tissue and the highly efficient production of signal. While the fluorescence properties of green fluorophores are well-known in vitro, less attention has been paid to their fluorescence once they are internalized within cells. In this study, the emission efficiency after cellular internalization of four common green fluorophores conjugated to avidin (Av-fluorescein, Av-Oregon green, Av-BODIPY-FL, and Av-rhodamine green) were compared after each conjugate was incubated with SHIN3 ovarian cancer cells. Using the lectin binding receptor system, the avidin-fluorophore conjugates were endocytosed, and their fluorescence was evaluated with fluorescence microscopy and flow cytometry. While fluorescein demonstrated the highest signal outside the cell, among the four fluorophores, internalized Av-rhodamine green emitted the most light from SHIN3 ovarian cancer cells both in vitro and in vivo. The internalized Av-rhodamine green complex appeared to localize to the endoplasmic vesicles. Thus, among the four common green fluorescent dyes, rhodamine green is the brightest green fluorescence probe after cellular internalization. This information could have implications for the design of tumor-targeted fluorescent probes that rely on cellular internalization for cancer detection.  相似文献   