首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An isocratic and sensitive HPLC assay was developed allowing the determination of the new anticancer drug nilotinib (AMN107) in human plasma, urine, culture medium and cell samples. After protein precipitation with perchloric acid, AMN107 underwent an online enrichment using a Zirchrom-PBD precolumn, was separated on a Macherey-Nagel C18-HD column and finally quantified by UV-detection at 258 nm. The total run time is 25 min. The assay demonstrates linearity within a concentration range of 0.005-5.0 microg/ml in plasma (r(2)=0.9998) and 0.1-10.0 microg/ml in urine (r(2)=0.9913). The intra-day precision expressed as coefficients of variation ranged depending on the spiked concentration between 1.27-9.23% in plasma and 1.77-3.29% in urine, respectively. The coefficients of variation of inter-day precision was lower than 10%. Limit of detection was 0.002 microg/ml in plasma and 0.01 microg/ml in urine. The described method is stable, simple, economic and is routinely used for in vivo and in vitro pharmacokinetic studies of AMN107.  相似文献   

2.
An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.  相似文献   

3.
A number of analytical methods have been established to quantify methylphenidate (MPH). However, to date no HPLC methods are applicable to human pharmacokinetic studies without the use of mass spectrometry (MS) detection. We developed a sensitive and reliable HPLC-fluorescence method for the determination of MPH in human plasma using 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride (DIB-Cl) as the derivatizing agent. An established GC-MS method was adopted in this study as a comparator assay. MPH was derivatized using DIB-Cl, and separated isocratically on a C18 column using a HPLC system with fluorescence detection (lambda(ex)=330 nm, lambda(em)=460 nm). The lower limit of quantification was found to be 1 ng/mL. A linear calibration curve was obtained over the concentrations ranging from 1 ng/mL to 80 ng/mL (r=0.998). The relative standard deviations of intra-day and inter-day variations were 相似文献   

4.
The validation of an analytical method to quantify the antiangiogenic, (Z)-3-[2,4-dimethyl-5-(2-oxo-1,2-dihydro-indol-3-ylidenemethyl)-1H-pyrrol-3-yl]propionic acid (SU006668) for pharmacokinetic determination in a phase I clinical trial, is described. HPLC, with a gradient mobile phase and UV detection at 440 nm, was used. SU006668 was extracted from plasma by precipitation of proteins with acetonitrile. The assay was linear from 25 to 2000 ng/ml (r(2)=0.997); sensitive (limit of quantification 25 ng/ml), accurate (RE 2.6-11.9%) and reproducible (inter-batch precision C.V. 3.2%). Pharmacokinetic data for six patients are presented. They show linear pharmacokinetics with a low volume of distribution and induction at doses of 50, 100 and 200 mg/m(2).  相似文献   

5.
Pentosidine is an advanced glycation end-product (AGE) appearing when arginine and lysine residues in proteins are cross-linked with carbonyl derivatives. This paper presents an improved method for the synthesis of pentosidine and reversed-phase chromatography of this substance with fluorometric detection that enables sensitive (0.01 pmol/mg protein) and specific determination of pentosidine in plasma. Separation is done twice on the same C(18) Vydac 218TP54 column, first with trifluoroacetic acid and next with heptafluorobutyric acid as ion pair. The inter-day coefficient of variation is 6.4% at pentosidine concentration in plasma of 25 pmol/mg protein and 8% at 1.7 pmol/mg protein. Spectral properties of pentosidine exploited during identification of the substance with UV absorption and fluorescence detectors are described. Maximum of absorbance was observed at 325 nm, maximum fluorescence at lambda(ex)/lambda(em)=330/373 nm. The method may prove useful for the study of processes associated with generation and accumulation of pentosidine in the body as a marker of AGE production in healthy subjects and patients with chronic renal failure.  相似文献   

6.
Tramadol, an analgesic agent, and its two main metabolites O-desmethyltramadol (M1) and N-desmethyltramadol (M2) were determined simultaneously in human plasma by a rapid and specific HPLC method. The sample preparation was a simple extraction with ethyl acetate. Chromatographic separation was achieved with a Chromolith Performance RP-18e 50 mm x 4.6 mm column, using a mixture of methanol:water (13:87, v/v) adjusted to pH 2.5 by phosphoric acid, in an isocratic mode at flow rate of 2 ml/min. Fluorescence detection (lambda(ex)=200 nm/lambda(em)=301 nm) was used. The calibration curves were linear (r(2)>0.997) in the concentration range of 2.5-500 ng/ml, 1.25-500 ng/ml and 5-500 ng/ml for tramadol, M1 and M2, respectively. The lower limit of quantification was 2.5 ng/ml for tramadol, 1.25 ng/ml for M1 and 5 ng/ml for M2. The within- and between-day precisions in the measurement of QC samples at four tested concentrations were in the range of 2.5-9.7%, 2.5-9.9% and 5.9-11.3% for tramadol, M1 and M2, respectively. The developed procedure was applied to assess the pharmacokinetics of tramadol and its two main metabolites following administration of 100mg single oral dose of tramadol to healthy volunteers.  相似文献   

7.
A direct-injection HPLC-based method has been developed for determining amounts of micafungin in human plasma using a novel hydrophobic/hydrophilic hybrid ODS column. The method is easy to perform and requires only 10 μL of a filtered plasma sample. The chromatographic separations were carried out with a gradient mode. The fluorescence detection wavelengths of excitation and emission were set at 273 nm and 464 nm, respectively. Retention times for micafungin and IS were 22.4 and 23.7 min, respectively. Micafungin and FR195743 (IS) peaks were completely separated with little tailing, and no interference was observed. The calibration curve of micafungin showed good linearity in the range of 0.5-20.0 μg/mL (r(2)=1.00). The intra-day accuracy ranged from -4.5 to 5.3%. The inter-day accuracy ranged from -9.8 to 1.5%. The precisions were less than 10%. This method is useful for the determination of micafungin in human plasma.  相似文献   

8.
A rapid, sensitive and simple high-performance liquid chromatographic (HPLC) method with ultraviolet detector (UV) has been developed for the determination of bifendate in 100 microl plasma of rats. Sample preparation was carried out by deproteinization with 100 microl of acetonitrile. A 20 microl of supernatant was directly injected into the HPLC system with methanol-double distilled water (65/35, v/v) as the mobile phase at a flow rate of 1.0 ml/min. Separation was performed with a microBondapak C(18) column at 30 degrees C. The peak was detected at 278 nm. The calibration curve was linear (r(2)=0.9989) in the concentration range of 0.028-2.80 microg/ml in plasma. The intra- and inter-day variation coefficients were not more than 6.55% and 6.07%, respectively. The limit of detection was 5 ng/ml. The mean recoveries of bifendate were ranged from 94.53% to 99.36% in plasma. The present method has been successfully applied to the pharmacokinetic study of bifendate liposome in rats.  相似文献   

9.
Fluoxetine (FLX) and norfluoxetine (NFLX) racemic mixtures were determined by reversed-phase liquid chromatography with fluorescence detection (lambda(exc)=227 nm, lambda(em)=305 nm). The calibration curves prepared from drug-free plasma and brain were linear in the range of 5-1000 ng ml(-1) and 100-40,000 ng g(-1) for doped samples, with detection limits of 3.2 and 2.1 ng ml(-1) in plasma and 31.5 and 26.1 ng g(-1) in brain tissue for FLX and NFLX, respectively. Enantiomer determination was carried out through normal phase HPLC-FD (lambda(exc)=224 nm, lambda(em)=336 nm) after precolumn chiral derivatization with R-1-(1-naphthyl)ethyl isocyanate. Standard curves also prepared in a drug-free matrix were linear for each enantiomer over the range of 2-1000 ng ml(-1) and 20-7000 ng g(-1) with detection limits for the four compounds ranging between 0.2 and 0.5 ng ml(-1) in plasma and between 3.0 and 8.2 ng g(-1) in brain tissue. In both methods the analytes were isolated from the biological matrix by a new solid-phase extraction procedure with recovery in plasma and brain over 90 and 87%, respectively. The repeatability of this extraction procedure was satisfactory within-day and between-day with CV<9.1%. This study also offered the opportunity to obtain an assessment of the potential relationships between the concentration of individual enantiomers of FLX and NFLX in plasma and brain tissue after chronic treatment with racemic FLX at a dose intended to mimic the human plasma concentration of FLX in standard clinical conditions, and therefore should make for more reliable extrapolation of neurochemical findings in other species.  相似文献   

10.
A high-performance liquid chromatographic method with fluorescence detection was developed to simultaneously analyze endothelins, a class of vasoactive peptides, in plasma samples. Sample preparation for HPLC analysis was carried out by initial stabilization of blood and plasma samples against transformation of big endothelins to mature endothelins and breakdown of mature endothelins by serine proteases, as well as oxidative modifications of endothelins. Deproteinization of plasma samples was achieved with acidified acetone, and the samples were further purified on molecular weight cutoff filters. Endothelins were separated on a reversed phase LC-318 column by gradient elution using a mobile phase containing acetonitrile and water (0.1% trifluoroacetic acid) and were analyzed by fluorescence detection (lambda(Ex), 280 nm; lambda(Em), 340). Limit of detection values were in the range of 0.2-0.5 pmol. Linear (R(2), 0.99) calibration curves were established for analyte amounts in the range of 1 to 100 pmols. Recoveries of endothelins from spiked plasma samples analyzed ranged from 60-95%. Under optimized conditions the HPLC-fluorescence method was determined to be sensitive and specific for the analysis of big endothelin-1, endothelin-1, endothelin-2, and endothelin-3 in plasma. Simultaneous measurement of these endothelins by the HPLC method should permit a better understanding of their specific roles and relationships under various pathological conditions.  相似文献   

11.
A new approach using a simple solid-phase extraction technique has been developed for the determination of pyronaridine (PND), an antimalarial drug, in human plasma. After extraction with C18 solid-phase sorbent, PND was analyzed using a reverse phase chromatographic method with fluorescence detection (at lambda(ex)=267 nm and lambda(em)=443 nm). The mean extraction recovery for PND was 95.2%. The coefficient of variation for intra-assay precision, inter-assay precision and accuracy was less than 10%. The quantification limit with fluorescence detection was 0.010 microg/mL plasma. The method described herein has several advantages over other published methods since it is easy to perform and rapid. It also permits reducing both, solvent use and sample preparation time. The method has been used successfully to assay plasma samples from clinical pharmacokinetic studies.  相似文献   

12.
N-(2-Mercaptopropionyl)-glycine (MPG) is a synthetic aminothiol antioxidant that is used in the treatment of cystinuria, rheumatoid arthritis, liver and skin disorders. Recent studies have shown that MPG can function as a chelating, cardioprotecting and a radioprotecting agent. Several other studies have shown that it may also act as a free radical scavenger because of its thiol group. Thiol-containing compounds have been detected in biological samples by various analytical methods such as spectrophotometric and colorimetric methods. However, these methods require several milliliters of a sample, time-consuming procedures and complicated derivatization steps, as well as having high detection limits. The present study describes a rapid, sensitive and relatively simple method for detecting MPG in biological tissues by using reverse-phase HPLC. With ThioGlo 3 [3H-Naphto[2,1-b] pyran, 9-acetoxy-2-(4-(2,5-dihydro-2,5-dioxo-1H-pyrrol-1-yl) phenyl-3-oxo-)] as the reagent, highly fluorescent derivatives of thiols can be obtained that are suitable for HPLC. MPG is derivatized with ThioGlo 3 and is then detected flourimetrically by reverse phase HPLC using a C18 column as the stationary phase. Acetonitrile: Water (75:25) with acetic acid and phosphoric acid (1 mL/L) is used as the mobile phase (excitation wavelength, 365 nm; emission wavelength, 445 nm). The calibration curve for MPG is linear over a range of 10-2500 nM (r=0.999) and the coefficients of the variation of within-run and between-run precision were found to be 0.3 and 2.1%, respectively. The detection limit was 5.07 nM per 20 microL injection volume. Quantitative relative recovery of MPG in the biological samples (plasma, lung, liver, kidney and brain) ranged from 90+/-5.3 to 106.7+/-9.3 %. Based on these results, we have concluded that this method is suitable for determining MPG in biological samples.  相似文献   

13.
Protein HC is a low molecular weight heterogeneous glycoprotein widely distributed in human body fluids and belonging to the lipocalin superfamily. The monomer contains a single (183 amino acid residues long) peptide chain with 3 cysteine residues (2 of which form a disulfide bridge) and is glycosylated. The molecular mass of the glycosylated protein is about 27 kDa. Native gel electrophoresis results revealed partial oligomerisation of protein HC, which therefore was analysed by gel filtration. Two forms (monomer and dimer) of the protein HC were isolated. The SAXS data were recorded on an X33 camera using synchrotron radiation (lambda=0.15 nm) at X33 beamline at the DORIS storage ring of DESY (Hamburg, Germany). Solution scattering results permitted determination of the structural parameters of both forms of the protein studied. The monomer of protein HC is characterised by a radius of gyration R(G)= 2.20 nm and D(max)=6.3 nm and the dimer by R(G)=2.99 nm and D(max)=9.5 nm.  相似文献   

14.
A sensitive method for the determination of CQP propionic acid in rat plasma was developed and validated after solid-phase extraction. Chromatographic separation was achieved on a reversed-phase Alltima C18 column with the mobile phase of methanol-0.15% (v/v) phosphoric acid solution (pH 2.5) and step gradient elution resulted in a total run time of about 20min. The analytes were detected by using UV detector at 345nm. A good linear relationship was obtained in the concentration range of 50-12,800ng/mL (r=0.9998). The intra-day RSDs and the inter-day RSDs at the concentration of 200, 800, 6400 and 12,800ng/mL were less than 7.0% and 11.0%, respectively. The intra-day accuracy ranged from 96.3 to 106.5% and the inter-day accuracy ranged from 98.6 to 113.4%, respectively. Average extraction recoveries ranged from 83.6 to 94.3% in plasma at the concentrations of 200, 800, 6400 and 12,800ng/mL. This method was successfully applied to the pharmacokinetic studies on rats.  相似文献   

15.
The possibility of using mycosporine-like amino acids (MAAs), with an apparent sunscreen function in nature, as ultraviolet radiation (UVR) blockers to prevent skin injury has been raised by diverse authors. Production of MAAs by the dinoflagellate Heterocapsa sp. (Dinophyceae) is shown here. Three major peaks with absorption maxima at 330.8, 332.0 and 333.2 nm were detected by high performance liquid chromatography (HPLC) analysis of methanolic extracts in all tested conditions. Analysis of crude extract by mass spectroscopy with electrospray ionization (MS-EI) showed a set of molecular ions ([M+H](+)) with main peaks being at m/z 242.4, 288.4, 303.3 and 333.3 u.m.a. According to these data, along with retention times, the MAA profile of Heterocapsa sp. is assumed to be composed of shinorine (lambda(max)=334 nm), mycosporine-2-glycine (lambda(max)=331 nm) and palythinol (lambda(max)=332 nm). A constitutive MAA content of about 4 microg (10(6) cells)(-1) was measured under exposure to PAR only. A maximal accumulation of MAA per culture volume of 1.1 mg l(-1) was obtained after 72 h of exposure to PAR+UVA, while the highest production rate (0.025 mg l(-1) h(-1)) was computed after 24 h of exposure to PAR+UVA+UVB.  相似文献   

16.
A new straightforward method based on cloud-point extraction (CPE) has been developed, optimized and validated for the determination of venlafaxine in human plasma by reversed-phase high-performance liquid chromatography with fluorescence detection. The non-ionic surfactant Triton X-114 (polyethylene glycol tert-octylphenyl ether) was chosen as the extract solvent. Separation was obtained using a reversed-phase Diamonsil column (C(18), 250mmx4.6mm I.D., 5mum) and a mobile phase composed of acetonitrile-phosphate buffer solution (pH 3.0)-triethylamine (33.5:66.5:0.4). Fluorescence detection was used (lambda(ex) 276nm, lambda(em) 598nm). Maprotiline was used as the internal standard. Under the optimum conditions, the linear range of venlafaxine in human plasma was 10-800ngmL(-1) (r(2)=0.9995). The limit of detection (LOD) was less than 2ngmL(-1) (S/N=3) and the limit of quantification (LOQ) was less than 10ngmL(-1) (S/N=10). The method was successfully applied for the evaluation of pharmacokinetic profiles of venlafaxine capsules in nine healthy volunteers.  相似文献   

17.
The presence of two spectral mechanisms, near-ultraviolet and green (lambda(max)=545nm), is strongly suggested by electroretinographic visual spectral sensitivity curves obtained under dark and red chromatic adaptation conditions in the compound eyes of the click beetle Pyrophorus punctatissimus. The bioluminescence emission of the dorsal prothoracic lanterns is deep green (lambda(max)=543nm) and that of the ventral abdominal lantern is lime green (lambda(max)=556nm) in colour in P. punctatissimus. A broad green visual receptor would detect both deep green and lime green bioluminescent optical signals.  相似文献   

18.
An HPLC assay for DMP 811, 4-ethyl-2-propyl-1-[(2′-(1H-tetrazol-5-yl)biphenyl-4-yl)-methyl]imidazole-5-carboxylic acid (I) in rat and dog plasma has been developed. Compound I was isolated from plasma using a liquid—liquid back extraction procedure. The extraction recovery was greater than 81%. Separation of I from endogenous components in plasma was achieved on an E. Merck C8 column using a mobile phase of 0.05 M ammonium acetate, brought to pH 3.75 with acetic acid, and acetonitrile (78:22, v/v). The eluent was monitored by fluorescence with excitation and emission set at 235 and 370 nm, respectively. The assay was linear from 2 to 2000 ng/ml. Inter- and intra-day coefficients of variation for the rat-plasma assay ranged from 0.9 to 5.2% (5–2000 ng/ml) and 2.7 to 16.5% (2–2000 ng/ml), respectively. The respective coefficients of variation for the dog-plasma assay were 1.9 to 5.6% and 1.2 to 14.0%. The percent differences from the accuracy results were 12% or less. Using 0.5 ml of plasma for extraction, the minimum quantifiable limit was 2 ng/ml. This method has been used to quantify plasma levels of I in rats or dogs following 3–10 mg/kg i.v. or p.o. doses.  相似文献   

19.
An accurate, sensitive and simple reverse-phase (RP) high-performance liquid chromatography (HPLC) assay for the simultaneous quantitative determination of emtricitabine and tenofovir in human blood plasma is described. Using 200 microL of plasma and BOND ELUT-C18 Varian columns, the solid phase extraction (SPE) method results in a clean baseline and high extraction efficiencies (100% for emtricitabine and 98.6% for tenofovir). An Atlantistrade mark dC-18 analytical column is used along with an 18 min linear gradient elution of phosphate buffer (pH 5.7) and methanol to provide sharp peaks for emtricitabine at 280 nm, tenofovir at 259 nm, and the internal standard 2',3'didoxyuridine (DDU) at 262 nm. The method was validated over the range of 10-10,000 ng/mL for both analytes, and is accurate (average accuracies of three different concentrations ranged from 98 to 105% for emtricitabine and 97 to 103% for tenofovir) and precise (within- and between-day precision ranged from 1.7 to 3.7% and 3.7 to 5.2%, respectively). This method is suitable for use in clinical pharmacokinetic studies and is nimble enough for therapeutic drug monitoring.  相似文献   

20.
An enantioselective HPLC method has been developed and validated for the stereospecific analysis of N-ethyl-3,4-methylenedioxyamphetamine (MDE) and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA). These compounds have been analyzed both from human plasma and urine after administration of 70 mg pure MDE-hydrochloride enantiomers to four subjects. The samples were prepared by hydrolysis of the o-glucuronate and sulfate conjugates using beta-glucuronidase/arylsulfatase and solid-phase extraction with a cation-exchange phase. A chiral stationary protein phase (chiral-CBH) was used for the stereoselective determination of MDE, HME and MDA in a single HPLC run using sodium dihydrogenphosphate, ethylendiaminetetraacetic acid disodium salt and isopropanol as the mobile phase (pH 6.44) and fluorimetric detection (lambda(ex) 286 nm, lambda(em) 322 nm). Moreover, a suitable internal standard (N-ethyl-3,4-methylenedioxybenzylamine) was synthesized and qualified for quantitation purposes. The method showed high recovery rates (>95%) and limits of quantitation for MDE and MDA of 5 ng/ml and for HME of 10 ng/ml. The RSDs for all working ranges of MDE, MDA and HME in plasma and urine, respectively, were less than 1.5%. After validation of the analytical methods in plasma and urine samples pharmacokinetic parameters were calculated. The plasma concentrations of (R)-MDE exceeded those of the S-enantiomer (ratio R:S of the area under the curve, 3.1) and the plasma half time of (R)-MDE was longer than that of (S)-MDE (7.9 vs. 4.0 h). In contrast, the stereochemical disposition of the MDE metabolites HME and MDA was reversed. Concentrations of the (S)-metabolites in plasma of volunteers were much higher than those of the (R)-enantiomers.  相似文献   