首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for determining tissue levels of Coenzyme A and various short-chain-length acyl-CoA derivatives using high-performance liquid chromatography is presented. Separation of the various compounds was accomplished using a reverse-phase Spherisorb ODS II, 5-microns C18 column. Mobile-phase solvents were (a) potassium phosphate, 220 mM; thiodiglycol (2,2-thiodiethanol), 0.05% (v/v), pH 4.0 and (b) methanol, 98%; chloroform; 2% (v/v). The various acyl-CoA derivatives were detected by monitoring the column effluent at 254 nm. Nearly baseline separation was obtained for a standard mixture of free CoASH, methylmalonyl-CoA, beta-hydroxy-beta-methylglutaryl-CoA, succinyl-CoA, acetoacetyl-CoA, acetyl-CoA, propionyl-CoA, isobutyryl-CoA, beta-methyl-crotonyl-CoA, and isovaleryl-CoA. CoA derivative profiles were determined in neutralized perchloric acid extracts of perfused rat hearts and livers and of isolated rat liver mitochondria to demonstrate the utility of this method for assessing the levels of CoA derivatives in biological samples.  相似文献   

2.
Reverse-phase high-performance liquid chromatography supports have been developed for use in separating proteins up to 300,000 Mr. They are based on silica supports to which octyl, cyanopropyl, or diphenyl groups are covalently bonded. Their effectiveness in rapidly separating several standard proteins is demonstrated. Applications presented include the separation of the α1 and α2 chains of chick Type I collagen within 1 h and the separation of the α and β components of human Type I collagen.  相似文献   

3.
A high-performance liquid chromatography system has been developed which resolves O-phosphoserine, O-phosphothreonine, and O4-phosphotyrosine. Separation is performed on an anion-exchange resin eluted with phosphate buffer of low pH. Detection of the amino acid derivatives is accomplished using O-phthalaldehyde in an in-stream fluorometric system. This highly sensitive method has been applied to the detection of phosphohydroxyamino acids in bovine myelin basic protein phosphorylated by the catalytic subunit of cyclic AMP-dependent protein kinase and in whole bovine myelin phosphorylated by endogenous kinases.  相似文献   

4.
Chromatography of AMP, NAD+, or NADH on a reverse-phase C18 Porasil B column rapidly removes ammonium formate or potassium phosphate from 90% of the nucleotide. Earlier reports showed these salts could not be separated from nucleotides by conventional desalting using gel filtration.  相似文献   

5.
Partially purified, papain-solubilized H-2a histocompatibility antigens from AJ mouse liver have been purified by reverse-phase high-performance liquid chromatography using RP-18 columns. β2-Microglobulin and H-2a heavy chain were separated from each other, without reduction or carboxymethylation, in less than 30 min by elution with a linear gradient of ethanol in 12 mm HCl. As much as 5 mg of protein has been loaded at a time. The recovery of the proteins from the RP-18 columns was estimated to be approximately 35% for the H-2a heavy chain and 80% for β2-microglobulin.  相似文献   

6.
A method is described for the determination of cortisol in human plasma and urine by high-performance liquid chromatography using fluorophotometric detection. After extraction with methylene chloride, cortisol is labelled with dansyl hydrazine, and then separated by high-performance chromatography. The eluate is monitored by a fluorophotometer at 350 nm (excitation) and 505 nm (emission). The optimum conditions for the determination, such as HCl and dansyl hydrazine concentrations, reaction time and reaction temperature, and for the eluent of high-performance liquid chromatography, are discussed. Linearity of the fluorescence intensity (peak height) with the amount of cortisol was obtained between 0.5 and 60 ng. The recoveries for 50 and 100 ng of added cortisol were 98.7 and 95.4% for plasma, and 96.4 and 90.6% for urine, respectively. Comparison with a radioimmunoassay gave a correlation coefficient of 0.978. The proposed method is suitable for the routine analysis of cortisol in plasma and urine.  相似文献   

7.
A simple method and apparatus are described for the efficient recovery of proteins from sodium dodecyl sulfate-polyacrylamide gel systems after electrophoretic resolution. This procedure provides for high yields of proteins which are free of sodium dodecyl sulfate and in certain cases, exhibit significant levels of biological activity.  相似文献   

8.
Methodology based on gradient elution reverse-phase high-performance liquid chromatography has been developed to permit monitoring of reactions of cisplatin, a noble metal-containing antineoplastic agent, with peptides, polypeptides, and proteins. Such reactions have been implicated in biotransformation of eisplatin. Specificity is provided by both the chromatographic column and the use of on-line uv and off-line atomic absorption spectroscopic detectors placed in series postcolumn. chromatographic conditions were optimized to maximize resolution of nitrogenous components. In some cases, however, resolution of platinum-containing components and those devoid of metal was not possible. This chromatographic overlap could be deconvoluted by sequentially monitoring the eluant with a uv detector (responsive to all proteinaceous material) and on atomic absorption spectrophotometer (specific for platinum detection). This technique has been applied to a kinetic investigation of cisplatin reactivity toward Met-enkephalin.  相似文献   

9.
10.
A simple quantitative method for estimating nanomole concentrations of 5-pyrrolidone-2-carboxylic acid (PCA) in tissue homogenates from mouse has been developed using reverse-phase HPLC. PCA was detected as the 4-nitrophenacyl ester which has an absorption maximum at 263 nm, a relatively high stability, and excellent chromatographic separation and detectability. This method offers distinct advantages over other analytical procedures thus far employed for measuring PCA in that the 4-nitrophenacyl derivative of PCA can be readily prepared from deproteinized tissue homogenates and quantitated by HPLC within relatively short time intervals with good precision and specificity.  相似文献   

11.
A rapid and efficient separation of amino acid phenylthiohydantoins by high-performance liquid chromatography has been accomplished by step-gradient elution with use of a mobile phase of acetate-buffered aqueous acetonitrile and an octadecylsilyl stationary phase. Typical analyses are completed in less than 12 min. Peak elution positions in this procedure are highly reproducible (with about 0.2% variance) and allow unambiguous identification of all residues. A procedure for the optimal positioning phenylthiohydantoin-Arg and -His is given. Molar extinction coefficients at 254 nm, which are particularly useful with common fixed wavelength detectors, are given for 25 amino acid phenylthiohydantoins.  相似文献   

12.
High-performance liquid chromatography was used to separate thiamine and its phosphate esters after conversion to corresponding highly fluorescent thiochrome derivatives by alkaline oxidation. These compounds were absorbed on LiChrosorb-NH2, eluted with acetonitrile-90 mm potassium phosphate buffer (pH 8.4), and determined spectrofluorometrically. A complete, rapid, and quantitative separation of thiochrome and its phosphate derivatives was made and the minimum amount detected was 1 pmol for each of these compounds.  相似文献   

13.
The rapid separation and quantitative determination of per-O-benzoyl oligosaccharides were obtained using high performance, liquid chromatography. Oligosaccharides were completely O-benzoylated without concomitant N-benzoylation of acetamidodeoxyhexoses. Benzoylation prior to analysis allowed a quantitative determination of picomolar amounts because the absorbance at 230 nm of these derivatives is directly proportional to the number of benzoyl groups present. Separation by normal and reversed-phase chromatography was demonstrated, and the best resolution was obtained on an Ultrasphere octyl column. Excellent separations of oligosaccharides containing up to 10 sugar residues present in mannosidosis urine and of malto-oligosaccharides containing up to 15 sugar residues present in Karo syrup were achieved within an analysis time of 30 min. Anomers of maltose, maltotriose, and maltotetraose were separated; for this reason, reduction of complex samples prior to analysis is advisable. The effect of linkage configuration on retention time was tested with reduced, α-linked di- and tri-glucopyranosides. The presence of an acetamidodeoxyhexose residue in an oligosaccharide significantly reduced its retention time, whereas branching had the opposite effect. A linear response was obtained for the injection of 1–600 pmol of raffinose, and the detection limit was 0.5 pmol. Derivatization and analysis of raffinose was shown to yield reproducible results within the range 0.01–1 μmol, and, with special precautions to minimize losses, as little as 100 pmol could be analyzed successfully.  相似文献   

14.
A method for the rapid and sensitive fluorometric analysis of porphyrin carboxylic acids by reverse-phase high-performance liquid chromatography is described. Separation of free porphyrin carboxylic acids was carried out with a microparticulate octadecylsilane column with elution by a gradient of methanol in phosphate buffer containing tetrabutylammonium hydroxide. Separation and quantitation of di-, tri-, tetra-, penta-, hexa-, hepta-, and octacar-boxylic porphyrins was achieved within 25 min at picomolar concentrations. The method is also capable of separating the type I and type III isomers of tetracarboxylic through hexacarboxylic porphyrins. By using a stopped flow technique, one can record fluorescence excitation and emission spectra of porphyrin carboxylic acids. This method is directly applicable to biological fluids such as urine, plasma, red cell lysates, or medium or extracts from cell culture.  相似文献   

15.
16.
Combining ion-exchange (AG MP-1) and reversed-phase (C-18) partition chromatography accomplishes a higher degree of purification of NADH than either method can provide alone. Final elution in 95% ethanol, dehydration with anhydrous sodium sulfate, and storage in dry 1,2-propanediol over molecular sieves prevents hydrolysis of the purified dinucleotide.  相似文献   

17.
The applicability of threshold logic units, a form of nonparametric pattern recognition, to the processing of metabolic profile data obtained by high-efficiency glass capillary column gas chromatography has been investigated. The test data included profiles of the volatile constituents of urine from normal individuals and from individuals with diabetes mellitus. A feature extraction algorithm allowed for dimensionality reduction and indicated the constituents most important in the normal versus pathological distinction. With an optimum number of dimensions, a normal versus pathological prediction rate of 93.75% was achieved. Gas chromatography—mass spectrometry was utilized to identify important profile constituents.  相似文献   

18.
19.
A procedure utilizing a reverse-phase semipreparative high-performance liquid chromatography column and a binary solvent system consisting of trifluoroacetic acid and 1-propanol has been developed for the semipreparative scale purification and analytical identification of four newly synthesized analogs of methotrexate. The methotrexate analogs containing a lysine or an ornithine residue in place of a terminal glutamate residue together with their respective dansyl derivatives were purified in milligram quantities by the procedures described.  相似文献   

20.
A rapid and sensitive method was devised for determining β-galactosidase activity specific for galactocerebroside. A fluorescent derivative of galactocerebroside, 1-O-galactosyl-2-N-1-dimethylaminonaphthalene-5-sulfonyl-sphingosine, was used as substrate, and the product, 2-N-1-dimethylaminonaphthalene-5-sulfonyl-sphingosine, was taken into organic solvent phase. Quantitative analysis of 2-N-dimethylaminonaphthalene-5-sulfonyl-sphingosine was carried out fluorometrically by use of high-performance liquid chromatography on silica gel column.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号