首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
Inhaled pharmaceuticals are formulated and delivered differently according to the therapeutic indication. However, specific device-formulation coupling is often fickle, and new medications or indications also demand new strategies. The discontinuation of chlorofluorocarbon propellants has seen replacement of older metered dose inhalers with dry powder inhaler formulations. High-dose dry powder inhalers are increasingly seen as an alternative dosage form for nebulised medications. In other cases, new medications have completely bypassed conventional inhalers and been formulated for use with unique inhalers such as the Staccato® device. Among these different devices, integration of software and electronic assistance has become a shared trend. This review covers recent device and formulation advances that are forming the current landscape of inhaled therapeutics.  相似文献   

2.
The accelerating development of gene therapy from research towards clinical trials and beyond has elevated the demand for practical viral vector-manufacturing solutions. The use of disposable upstream technology is gaining traction in clinical manufacturing. Packed-bed or fixed-bed reactors, where column is packed with immobilized biocatalyst particles providing surface to constrain the cells in a particular region of the reactor, have been widely used in bioprocessing applications since mid-1900s. However, the world's first single-use, fully integrated, high cell density, fixed-bed bioreactor was launched only approximately a decade ago. By now, several single-use, fixed-bed technology solutions have been developed in a small scale. Scaling-up the manufacturing can be challenging and for commercial-scale manufacturing, there is practically only one single-use, good manufacturing practice-compliant option available. This study reviews the latest, fully disposable, fixed-bed bioreactors; compares the virus production in the different systems; and discusses important manufacturing cost-related topics. It is predicted that single-use, fixed-bed bioreactors will receive even more attention in the field of viral vector manufacturing and commercialization, especially with the need for higher virus titers and virus yields.  相似文献   

3.
The FDA proposed a parametric tolerance interval (PTI) test at the October 2005 Advisory Committee meeting as a replacement of the attribute (counting) test for delivered dose uniformity (DDU), published in the 1998 draft guidance for metered dose inhalers (MDIs) and dry powder inhalers (DPIs) and the 2002 final guidance for inhalation sprays and intranasal products. This article (first in a series of three) focuses on the test named by the FDA “87.5% coverage.” Unlike a typical two-sided PTI test, which controls the proportion of the DDU distribution within a target interval (coverage), this test is comprised of two one-sided tests (TOST) designed to control the maximum amount of DDU values in either tail of the distribution above and below the target interval. Through simulations, this article characterizes the properties and performance of the proposed PTI-TOST under different scenarios. The results show that coverages of 99% or greater are needed for a batch to have acceptance probability 98% or greater with the test named by the FDA “87.5% coverage” (95% confidence level), while batches with 87.5% coverage have less than 1% probability of being accepted. The results also illustrate that with this PTI-TOST, the coverage requirement for a given acceptance probability increases as the batch mean deviates from target. The accompanying articles study the effects of changing test parameters and the test robustness to deviations from normality.  相似文献   

4.
The purpose of this article is to catalogue in a systematic way the available information about factors that may influence the outcome and variability of cascade impactor (CI) measurements of pharmaceutical aerosols for inhalation, such as those obtained from metered dose inhalers (MDIs), dry powder inhalers (DPIs) or products for nebulization; and to suggest ways to minimize the influence of such factors. To accomplish this task, the authors constructed a cause-and-effect Ishikawa diagram for a CI measurement and considered the influence of each root cause based on industry experience and thorough literature review. The results illustrate the intricate network of underlying causes of CI variability, with the potential for several multi-way statistical interactions. It was also found that significantly more quantitative information exists about impactor-related causes than about operator-derived influences, the contribution of drug assay methodology and product-related causes, suggesting a need for further research in those areas. The understanding and awareness of all these factors should aid in the development of optimized CI methods and appropriate quality control measures for aerodynamic particle size distribution (APSD) of pharmaceutical aerosols, in line with the current regulatory initiatives involving quality-by-design (QbD). Editorial Comment: The International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS) is an international association of innovator and generic companies that develop, manufacture or market orally inhaled and nasal drug products for local and systemic treatment of a variety of debilitating diseases such as asthma, chronic obstructive pulmonary disease and diabetes. IPAC-RS is committed to advancing consensus-based, scientifically driven standards and regulations for these products, with the purpose of facilitating the availability of high-quality, safe, and efficacious drug products to patients.  相似文献   

5.
Current pharmacopeial methods for testing dry powder inhalers (DPIs) require that 4.0 L be drawn through the inhaler to quantify aerodynamic particle size distribution of “inhaled” particles. This volume comfortably exceeds the internal dead volume of the Andersen eight-stage cascade impactor (ACI) and Next Generation pharmaceutical Impactor (NGI) as designated multistage cascade impactors. Two DPIs, the second (DPI-B) having similar resistance than the first (DPI-A) were used to evaluate ACI and NGI performance at 60 L/min following the methodology described in the European and United States Pharmacopeias. At sampling times ≥2 s (equivalent to volumes ≥2.0 L), both impactors provided consistent measures of therapeutically important fine particle mass (FPM) from both DPIs, independent of sample duration. At shorter sample times, FPM decreased substantially with the NGI, indicative of incomplete aerosol bolus transfer through the system whose dead space was 2.025 L. However, the ACI provided consistent measures of both variables across the range of sampled volumes evaluated, even when this volume was less than 50% of its internal dead space of 1.155 L. Such behavior may be indicative of maldistribution of the flow profile from the relatively narrow exit of the induction port to the uppermost stage of the impactor at start-up. An explanation of the ACI anomalous behavior from first principles requires resolution of the rapidly changing unsteady flow and pressure conditions at start up, and is the subject of ongoing research by the European Pharmaceutical Aerosol Group. Meanwhile, these experimental findings are provided to advocate a prudent approach by retaining the current pharmacopeial methodology.KEY WORDS: cascade impactor, compendial method, dry powder inhaler, sample volume  相似文献   

6.
The purpose of this research was to micronize beclomethasone-17,21-dipropionate (BDP), an anti-inflammatory inhaled corticosteroid commonly used to treat asthma, using the rapid expansion of supercritical solution (RESS) technique. The RESS technique was chosen for its ability to produce both micron particles of high purity for inhalation, and submicron/nano particles as a powder handling aid for use in next generation dry powder inhalers (DPIs). Particle formation experiments were carried out with a capillary RESS system to determine the effect of experimental conditions on the particle size distribution (PSD). The results indicated that the RESS process conditions strongly influenced the particle size and morphology; with the BDP mean particle size decreasing to sub-micron and nanometer dimensions. An increase in the following parameters, i.e. nozzle diameter, BDP mol fraction, system pressure, and system temperature; led to larger particle sizes. Aerodynamic diameters were estimated from the SEM data using three separate relations, which showed that the RESS technique is promising to produce particles suitable for pulmonary delivery.  相似文献   

7.
The full-resolution next generation impactor (NGI) and three abbreviated impactor systems were used to obtain the apparent aerodynamic particle size distribution (APSD) and other quality measures for marketed dry powder inhalers (DPIs) using the compendial method and efficient data analysis (EDA). APSD for the active pharmaceutical ingredient (API) in Spiriva® Handihaler®, Foradil® Aerolizer®, and Relenza® Diskhaler® was obtained using a full-resolution NGI at 39, 60, and 90 L/min, respectively. Two reduced NGI (rNGI) configurations, the filter-only configuration (rNGI-f) and the modified-cup configuration (rNGI-mc), and the fast-screening impactor (FSI) with appropriate inserts to provide a 5-μm cut size were evaluated. The fine particle dose (FPD) obtained using the FSI for Spiriva was statistically similar to that obtained using the full NGI. However, the FPD for both Foradil and Relenza obtained using the FSI was significantly different from that obtained using the full NGI. Despite this, no significant differences were observed for the fine particle fraction (FPF) obtained using the FSI relative to that obtained from the full NGI for any of the DPIs. The use of abbreviated impactor systems appears promising with good agreement observed with the full-resolution NGI, except for small differences observed for the rNGI-mc configuration. These small differences may be product- and/or flow rate-specific, and further evaluation will be required to resolve these differences.  相似文献   

8.
Compendial methods determining dry powder inhaler (DPI)-emitted aerosol aerodynamic particle size distribution (APSD) collect a 4-L air sample containing the aerosol bolus, where the flow, which propagates through the cascade impactor (CI) measurement system from the vacuum source, is used to actuate the inhaler. A previous article described outcomes with two CIs (Andersen eight-stage cascade impactor (ACI) and Next-Generation Pharmaceutical Impactor (NGI)) when the air sample volume was ≤4 L with moderate-resistance DPIs. This article extends that work, examining the hypothesis that DPI flow resistance may be a factor in determining outcomes. APSD measurements were made using the same CI systems with inhalers representing low and high flow resistance extremes (Cyclohaler® and HandiHaler® DPIs, respectively). The ratio of sample volume to internal dead space (normalized volume (V*)) was varied from 0.25 to 1.98 (NGI) and from 0.43 to 3.46 (ACI). Inhaler resistance was a contributing factor to the rate of bolus transfer; the higher resistance DPI completing bolus relocation to the NGI pre-separator via the inlet when V* was as small as 0.25, whereas only ca. 50% of the bolus mass was collected at this condition with the Cyclohaler® DPI. Size fractionation of the bolus from either DPI was completed within the ACI at smaller values of V* than within the NGI. Bolus transfer from the Cyclohaler® capsule and from the HandiHaler® to the ACI system were unaffected by the different flow rise time observed in the two different flow controller systems, and the effects the ACI-based on APSD measurements were marginal.  相似文献   

9.
The goal of this article is to discuss considerations regarding implementation of the parametric tolerance interval two one-sided test (PTI-TOST) for delivered dose uniformity (DDU) of orally inhaled products (OIPs). That test was proposed by FDA in 2005 as an alternative to the counting test described in the 1998 draft FDA guidance for metered dose inhalers and dry powder inhalers. The 2005 PTI-TOST, however, still has not found much use in practice despite the general desirability of parametric approaches in modern pharmaceutical quality control. A key reason for its slow uptake is that it rejects, with high probability, batches whose quality is considered acceptable by all other published regulatory and pharmacopeial standards as well as by the DDU specifications for many approved OIPs. Manufacturers therefore continue using nonparametric counting tests for control of DDU. A simulated case study presented here compares the consequences of the PTI-TOST compared to the counting test. The article discusses three possibilities that would help increase the uptake of the PTI-TOST approach, namely: product-specific quality standards, a different default standard suitable for the majority of OIPs, and integration of the PTI-TOST with a continuous verification control strategy rather than using it as an isolated-batch (transactional) end-product testing. In any of these efforts, if a parametric test is used, it is critical not to set the target quality close to, or at the boundary of the process/product capabilities, because PTI tests are designed to reject with high probability the identified target quality.  相似文献   

10.
Fine particle dose (FPD) is a critical quality attribute for orally inhaled products (OIPs). The abbreviated impactor measurement (AIM) concept simplifies its measurement, provided there is a validated understanding of the relationship with the full resolution pharmacopoeial impactor (PIM) data for a given product. This multi-center study compared fine particle dose determined using AIM and PIM for five dry powder inhaler (DPIs) and two pressurized metered-dose inhaler (pMDI) products, one of which included a valved holding chamber (VHC). Reference measurements of FPDPIM were made by each organization using either the full-resolution Andersen 8-stage non-viable impactor (ACI) or Next Generation Impactor (NGI). FPDAIM was determined for the same OIP(s) with their choice of abbreviated impactor (fast screening impactor (FSI), fast screening Andersen (FSA), or reduced NGI (rNGI)). Each organization used its validated assay method(s) for the active pharmaceutical ingredient(s) (APIs) involved. Ten replicate measurements were made by each procedure. The upper size limit for FPDAIM varied from 4.4 to 5.0 μm aerodynamic diameter, depending upon flow rate and AIM apparatus; the corresponding size limit for FPDPIM was fixed at 5 μm in accordance with the European Pharmacopoeia. The 90% confidence interval for the ratio [FPDAIM/FPDPIM], expressed as a percentage, was contained in the predetermined 85–118% acceptance interval for nine of the ten comparisons of FPD. The average value of this ratio was 105% across all OIPs and apparatuses. The findings from this investigation support the equivalence of AIM and PIM for determination of FPD across a wide range of OIP platforms and measurement techniques.  相似文献   

11.
The potential of fine excipient materials to improve the performance of carrier-based dry powder inhalation mixtures is well acknowledged. The mechanisms underlying this potential are, however, open to question till date. Elaborate understanding of these mechanisms is a requisite for rational rather than empirical development of ternary dry powder inhalation mixtures. While effects of fine excipient materials on drug adhesion to and detachment from surfaces of carrier particle have been extensively investigated, effects on other processes, such as carrier–drug mixing, capsule/blister/device filling, or aerosolization in inhaler devices, have received little attention. We investigated the influence of fine excipient materials on the outcome of the carrier–drug mixing process. We studied the dispersibility of micronized fluticasone propionate particles after mixing with α-lactose monohydrate blends comprising different fine particle concentrations. Increasing the fine (D < 10.0 μm) excipient fraction from 1.84 to 8.70% v/v increased the respirable drug fraction in the excipient–drug mixture from 56.42 to 67.80% v/v (p < 0.05). The results suggest that low concentrations of fine excipient particles bind to active sites on and fill deep crevices in coarse carrier particles. As the concentration of fine excipient particles increases beyond that saturating active sites, they fill the spaces between and adhere to the surfaces of coarse carrier particles, creating projections and micropores. They thereby promote deagglomeration of drug particles during carrier–drug mixing. The findings pave the way for a comprehensive understanding of contributions of fine excipient materials to the performance of carrier-based dry powder inhalation mixtures.  相似文献   

12.

Purpose

Health care infection control has led to increased utilization of disposable medical devices, which has subsequently led to adverse environmental effects attributed to health care and its supply chain. In dental practice, the dental bur is a commonly used instrument that can be either reused or used once and then disposed. To evaluate the disparities in environmental impacts of disposable and reusable dental burs, a comparative life cycle assessment (LCA) was performed.

Methods

The functional unit was defined as one reusable dental bur, where the maximum instances reused was 30 (or in the case of a disposable, the equivalent functional unit would be 30 disposable dental burs). The system boundary included all cradle-to-grave aspects of both single-use and reused burs, including raw material extraction, manufacturing, packaging, distribution, reuse, and disposal. Primary data included the following: operating parameters for ultrasonic cleaning, manual cleaning, and autoclaving of the burs. The secondary data for raw material extraction and production of dental bur and packaging were obtained directly from life cycle inventory databases. Sensitivity analyses were also performed with respect to ultrasonic and autoclave loading.

Results and discussion

Findings from this research showed that when the ultrasonic and autoclave were loaded optimally, reusable burs had 40 % less of an environmental impact than burs used on a disposable basis. When the autoclave and ultrasonic were loaded to approximately two-third capacity, four environmental impact categories favored reusable burs (i.e., ozone depletion, smog, respiratory effects, exotoxicity), and four impact categories environmentally favored disposables (i.e., acidification, eutrophication, carcinogenics, and non-carcinogenics). When the autoclave and ultrasonic were loaded to approximately one-third capacity, reusable dental burs posed more negative environmental impacts in eight of nine environmental impact categories when compared to disposable burs.

Conclusions

Operational efficiency of ultrasonic and autoclave cleaning equipment should be emphasized to enhance the environmental performance of bur reuse. In fact, improper loading of the ultrasonic and autoclave can lead to greater adverse environmental impacts than if the burs were treated as disposables. The environmental and economic impacts associated with bur reuse are expected to be similar with other dental devices that are designated as disposable but are capable of being reused (e.g., scalpels, forceps).  相似文献   

13.
Modified Vaccinia Ankara (MVA) virus is a promising vector for vaccination against various challenging pathogens or the treatment of some types of cancers, requiring a high amount of virions per dose for vaccination and gene therapy. Upstream process intensification combining perfusion technologies, the avian suspension cell line AGE1.CR.pIX and the virus strain MVA-CR19 is an option to obtain very high MVA yields. Here the authors compare different options for cell retention in perfusion mode using conventional stirred-tank bioreactors. Furthermore, the authors study hollow-fiber bioreactors and an orbital-shaken bioreactor in perfusion mode, both available for single-use. Productivity for the virus strain MVA-CR19 is compared to results from batch and continuous production reported in literature. The results demonstrate that cell retention devices are only required to maximize cell concentration but not for continuous harvesting. Using a stirred-tank bioreactor, a perfusion strategy with working volume expansion after virus infection results in the highest yields. Overall, infectious MVA virus titers of 2.1–16.5 × 109 virions/mL are achieved in these intensified processes. Taken together, the study shows a novel perspective on high-yield MVA virus production in conventional bioreactor systems linked to various cell retention devices and addresses options for process intensification including fully single-use perfusion platforms.  相似文献   

14.
The purpose of this article is to review the suitability of the analytical and statistical techniques that have thus far been developed to assess the dissolution behavior of particles in the respirable aerodynamic size range, as generated by orally inhaled products (OIPs) such as metered-dose inhalers and dry powder inhalers. The review encompasses all analytical techniques publicized to date, namely, those using paddle-over-disk USP 2 dissolution apparatus, flow-through cell dissolution apparatus, and diffusion cell apparatus. The available techniques may have research value for both industry and academia, especially when developing modified-release formulations. The choice of a method should be guided by the question(s) that the research strives to answer, as well as by the strengths and weaknesses of the available techniques. There is still insufficient knowledge, however, for translating the dissolution data into statements about quality, performance, safety, or efficacy of OIPs in general. Any attempts to standardize a dissolution method for compendial inclusion or compendial use would therefore be premature. This review reinforces and expands on the 2008 stimulus article of the USP Inhalation Ad Hoc Advisory Panel, which "could not find compelling evidence suggesting that such dissolution testing is kinetically and/or clinically crucial for currently approved inhalation drug products."  相似文献   

15.
A new approach for the sensitive detection of Staphylococcal enterotoxin B (SEB) is presented based upon an electrochemical enzymatic immunoassay that utilizes thiolated antibodies immobilized on a gold surface. This method relies on the use of amine- or sulfhydryl-reactive heterobifunctional cross-linkers for the introduction of 2-pyridyl-disulfide groups to the antibody. The disulfide-containing linkages are subsequently cleaved with a suitable reducing agent, such as dithiothreitol (DTT), and the thiolated antibody–gold bond is covalently formed on a gold working electrode. Various cross-linking agents for immobilization of the capture antibody onto the gold electrode were investigated and compared. Factors influencing the thiolation and immobilization were investigated and optimized. The feasibility of such antibody immobilization and the subsequent sandwich enzyme immunoassay is demonstrated for the sensitive detection of SEB. The detection limit estimated from a representative dose–response curve is 1 ng/mL, corresponding to 5 pg in a 5-μL sample. Coupling the specificity of immunoassays with the sensitivity and low detection limits of electrochemical detection shows real promise for future sensing technology in enabling the development of single-use disposable devices.  相似文献   

16.
BackgroundPost-market surveillance is a key regulatory function to prevent substandard and falsified (SF) medicines from being consumed by patients. Field deployable technologies offer the potential for rapid objective screening for SF medicines.Methods and findingsWe evaluated twelve devices: three near infrared spectrometers (MicroPHAZIR RX, NIR-S-G1, Neospectra 2.5), two Raman spectrometers (Progeny, TruScan RM), one mid-infrared spectrometer (4500a), one disposable colorimetric assay (Paper Analytical Devices, PAD), one disposable immunoassay (Rapid Diagnostic Test, RDT), one portable liquid chromatograph (C-Vue), one microfluidic system (PharmaChk), one mass spectrometer (QDa), and one thin layer chromatography kit (GPHF-Minilab). Each device was tested with a series of field collected medicines (FCM) along with simulated medicines (SIM) formulated in a laboratory. The FCM and SIM ranged from samples with good quality active pharmaceutical ingredient (API) concentrations, reduced concentrations of API (80% and 50% of the API), no API, and the wrong API. All the devices had high sensitivities (91.5 to 100.0%) detecting medicines with no API or the wrong API. However, the sensitivities of each device towards samples with 50% and 80% API varied greatly, from 0% to 100%. The infrared and Raman spectrometers had variable sensitivities for detecting samples with 50% and 80% API (from 5.6% to 50.0%). The devices with the ability to quantitate API (C-Vue, PharmaChk, QDa) had sensitivities ranging from 91.7% to 100% to detect all poor quality samples. The specificity was lower for the quantitative C-Vue, PharmaChk, & QDa (50.0% to 91.7%) than for all the other devices in this study (95.5% to 100%).ConclusionsThe twelve devices evaluated could detect medicines with the wrong or none of the APIs, consistent with falsified medicines, with high accuracy. However, API quantitation to detect formulations similar to those commonly found in substandards proved more difficult, requiring further technological innovation.  相似文献   

17.
The biopharmaceutical industry gains enormous flexibility in production processes by using sterilized preassembled single-use devices. Gamma irradiation is an established sterilization technology that may be restricted in the future by the availability of 60Co as irradiation source and irradiation capacities. X-ray technology is considered an alternative type of radiation for sterilizing SU equipment. In the context of extractables and leachables—one concern connected with the use of single-use process equipment—the effect of X-ray irradiation on the extractables profile of the materials needs to be compared to established gamma irradiation to qualify this alternative technology. An approach is presented to obtain robust and comprehensive extractables data for materials used in SU devices after sterilization either using X-ray or gamma irradiation. A careful selection of the test items and the test design allows a one-to-one comparison of data obtained from a combination of orthogonal analytical techniques. The extractables of a modern SU film material and the copolyester Tritan™ are evaluated. The data presented allow a risk evaluation on the safety of this new sterilization modality for biopharmaceutical applications. It is demonstrated that the extractables profile of a polymer is not affected by the type of irradiation used for sterilization.  相似文献   

18.
Advances in single-use technologies can enable greater speed, flexibility, and a smaller footprint for multi-product production facilities, such as at a contract manufacturer. Recent efforts in the area of cell line and media optimization have resulted in bioreactor productivities that exceed 8 g/L in fed-batch processes or 25 g/L in high-density cell culture processes. In combination with the development of single-use stirred tank bioreactors with larger working volumes, these intensified upstream processes can now be fit into a single-use manufacturing setting. Contrary to these upstream advances, downstream single-use technologies have been slower to follow, mostly limited by low capacity, high cost, and poor scalability. In this study we describe a downstream process based solely on single-use technologies that meets the challenges posed by expression of a mAb (IgG(1)) in a high-density suspension culture of PER.C6 cells. The cell culture harvest was clarified by enhanced cell settling (ECS) and depth filtration. Precipitation was used for crude purification of the mAb. A high capacity chromatographic membrane was then used in bind/elute mode, followed by two membranes in flow-through (FT) mode for polishing. A proof of concept of the entire disposable process was completed for two different scales of the purification train.  相似文献   

19.

Background

As more inhaled corticosteroid (ICS) devices become available, there may be pressure for health-care providers to switch patients with asthma to cheaper inhaler devices. Our objective was to evaluate impact on asthma control of inhaler device switching without an accompanying consultation in general practice.

Methods

This 2-year retrospective matched cohort study used the UK General Practice Research Database to identify practices where ICS devices were changed without a consultation for ≥5 patients within 3 months. Patients 6–65 years of age from these practices whose ICS device was switched were individually matched with patients using the same ICS device who were not switched. Asthma control over 12 months after the switch was assessed using a composite measure including short-acting β-agonist and oral corticosteroid use, hospitalizations, and subsequent changes to therapy.

Results

A total of 824 patients from 55 practices had a device switch and could be matched. Over half (53%) of device switches were from dry powder to metered-dose inhalers. Fewer patients in switched than matched cohort experienced successful treatment based on the composite measure (20% vs. 34%) and more experienced unsuccessful treatment (51% vs. 38%). After adjusting for possible baseline confounding factors, the odds ratio for treatment success in the switched cohort compared with controls was 0.29 (95% confidence interval [CI], 0.19 to 0.44; p < 0.001) and for unsuccessful treatment was 1.92 (95% CI, 1.47 to 2.56; p < 0.001).

Conclusion

Switching ICS devices without a consultation was associated with worsened asthma control and is therefore inadvisable.  相似文献   

20.
Packaging waste forms a significant part of municipal solid waste and has caused increasing environmental concerns, resulting in a strengthening of various regulations aimed at reducing the amounts generated. Among other materials, a wide range of oil-based polymers is currently used in packaging applications. These are virtually all non-biodegradable, and some are difficult to recycle or reuse due to being complex composites having varying levels of contamination. Recently, significant progress has been made in the development of biodegradable plastics, largely from renewable natural resources, to produce biodegradable materials with similar functionality to that of oil-based polymers. The expansion in these bio-based materials has several potential benefits for greenhouse gas balances and other environmental impacts over whole life cycles and in the use of renewable, rather than finite resources. It is intended that use of biodegradable materials will contribute to sustainability and reduction in the environmental impact associated with disposal of oil-based polymers.The diversity of biodegradable materials and their varying properties makes it difficult to make simple, generic assessments such as biodegradable products are all ‘good’ or petrochemical-based products are all ‘bad’. This paper discusses the potential impacts of biodegradable packaging materials and their waste management, particularly via composting. It presents the key issues that inform judgements of the benefits these materials have in relation to conventional, petrochemical-based counterparts. Specific examples are given from new research on biodegradability in simulated ‘home’ composting systems. It is the view of the authors that biodegradable packaging materials are most suitable for single-use disposable applications where the post-consumer waste can be locally composted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏