首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
A sensitive and selective HPLC-solid-phase extraction procedure was developed for the determination of platelet-activating factor antagonist BN-50727 and its metabolites in human plasma. The procedure consisted of an automated solid-phase extraction of the drug and metabolites on disposable propylcarboxylic acid cartridges, followed by on-line chromatographic separation. The method was linear from 3.75 to 2400 ng/ml and the limit of quantitation for BN-50727 in plasma samples was 3.75 ng/ml. The within-run precision of the method, expressed as relative standard deviation, ranged from 2.1 to 8.1%. The accuracy, expressed as relative error, ranged from −3.5 to 4.0%. For the main metabolite, the O-demetthylated BN-50727 product, the method was linear from 7.5 to 2400 ng/ml and the limit of quantitation in plasma was 7.5 ng/ml. The within-run precision ranged from 2.1 to 11.0% and the accuracy from −5.3 to 1.1%. This paper describes the validation of the analytical methodology for the determination of BN-50727 in human plasma and also of its metabolites. The method has been used to follow the time course of BN-50727 and its metabolites in human plasma after administration of single and multiple doses.  相似文献   

2.
A method was developed for the quantification of matrine in human plasma using a liquid-liquid extraction procedure followed by gas-chromatography-mass spectrometry (GC/MS) analysis. Deuterated matrine, an internal standard of the analysis, was spiked into the plasma samples before extraction. Linear detection responses were obtained for matrine concentrations ranging from 10 to 500 ng/ml. The intra-day and inter-day precision ranged from 0.4 to 4.0% and 1.0-3.5%, respectively. The intra-day accuracy was between -7.3 and 4.5%. The limit of quantification for matrine was 23 ng/ml. The extraction efficiency averaged about 38%. The validated GC/MS method will be used to quantify matrine in human plasma samples collected in a clinical trial study.  相似文献   

3.
A simple, rapid and sensitive method for determination of rivastigmine in plasma samples was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography with mass spectrometry (GC-MS). The optimum conditions for the SPME procedure were: headspace extraction on a 65-microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber; 0.5 ml of plasma modified with 1.0 ml of sodium hydroxide-sodium carbonate solution (0.7 M:0.5M); extraction temperature of 100 degrees C, with stirring at 2000 rpm for 30 min. The calibration curve showed linearity in the range from 0.2 to 80 ng/ml with regression coefficient corresponding to 0.9965 and coefficient of the variation of the points of the calibration curve lower than 10%. The quantification limit for rivastigmine in plasma was 0.2 ng/ml. The method was applied to determination of rivastigmine in canine plasma samples from animals after a single oral administration.  相似文献   

4.
A sensitive method has been developed for the determination of the vasoactive compounds cinnarizine and flunarizine in plasma, urine and milk samples from man and animals. The procedure involves the extraction of the drugs and their internal standard from the biological samples at alkaline pH, back-extraction into sulphuric acid and re-extraction into the organic phase (heptane—isoamyl alcohol).The analyses were carried out by gas chromatography using a nitrogen-selective thermionic specific detector. The detection limit was 0.5 ng/ml of biological fluid and extraction recoveries were sufficiently high (87–94%).The method was applied to plasma samples from bioavailability studies of both cinnarizine and flunarizine in healthy volunteers, and to plasma, urine and milk samples from flunarizine-treated dogs.  相似文献   

5.
A high performance liquid chromatography (HPLC) method for the estimation of pravastatin in human plasma and urine samples has been developed. The preparation of the samples was performed by automated solid phase extraction using clonazepam as internal standard. The compounds were separated by isocratic reversed-phase HPLC (C(18)) and detected at 239 nm. The method was linear up to concentrations of 200 ng/ml in plasma and 2000 ng/ml in urine. The intra-assay variability for pravastatin in plasma ranged from 0.9% to 3.5% and from 2.5% to 5.3% in urine. The inter-assay variability ranged from 9.1% to 10.2% in plasma and from 3.9% to 7.5% in urine. The validated limits of quantification were 1.9 ng/ml for plasma and 125 ng/ml for urine estimation. These method characteristics allowed the determination of the pharmacokinetic parameters of pravastatin after administration of therapeutic doses.  相似文献   

6.
A method is proposed for the determination of nicotine and cotinine in human urine, plasma and saliva. Nicotine and cotinine were extracted from alkalinized sample with ethyl ether and concentrated to minimum volume with nitrogen stream. The volatility of nicotine was prevented by the addition of acetic acid to the organic solvent during evaporation. Peak shapes and quantitation of nicotine and cotinine are excellent, with linear calibration curves over a wide range of 1-10,000 ng/ml. The detection limits of nicotine and cotinine are 0.2 ng/ml in urine and 1.0 ng/ml in plasma and saliva. The intra-day precision of nicotine and cotinine in all samples was <5% relative standard deviation (RSD). Urine, plasma and saliva samples of 303 non-smoking and 41 smoking volunteers from a girl's high school in Korea were quantified by the described procedure. As a result, the concentrations of nicotine and cotinine in plasma ranged from 6 to 498 ng/ml and 4 to 96 ng/ml. Otherwise, those of nicotine and cotinine in saliva ranged from 0 to 207 ng/ml and 0 to 42 ng/ml, and those of nicotine and cotinine in urine ranged from 0 to 1,590 ng/ml and 0 to 2,986 ng/ml, respectively. We found that the concentration of cotinine in plasma was successfully predicted from the salivary cotinine concentration by the equation y=2.31x+4.76 (x=the concentration of cotinine in saliva, y=the concentration of cotinine in plasma). The results show that through the accurate determination of cotinine in saliva, the risk of ETS-exposed human can be predicted.  相似文献   

7.
Astragaloside IV is a novel cardioprotective agent extracted from the Chinese medical herb Astragalus membranaceus (Fisch) Bge. This agent is being developed for treatment for cardiovascular disease. Further development of Astragaloside IV will require detailed pharmacokinetic studies in preclinical animal models. Therefore, we established a sensitive and accurate high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (LC/MS/MS) quantitative detection method for measurement of Astragaloside IV levels in plasma, urine as well as other biological samples including bile fluid, feces and various tissues. Extraction of Astragaloside IV from plasma and other biological samples was performed by Waters OASIS(trade mark) solid phase extraction column by washing with water and eluting with methanol, respectively. An aliquot of extracted residues was injected into LC/MS/MS system with separation by a Cosmosil C18 5 microm, 150 mm x 2.0 mm) column. Acetonitrile:water containing 5 microM NaAc (40:60, v/v) was used as a mobile phase. The eluted compounds were detected by tandem mass spectrometry. The average extraction recoveries were greater than 89% for Astragaloside IV and digoxin from plasma, while extraction recovery of Astragaloside IV and digoxin from tissues, bile fluid, urine and fece ranged from 61 to 85%, respectively. Good linearity (R2>0.9999) was observed throughout the range of 10-5000 ng/ml in 0.5 ml rat plasma and 5-5000 ng/ml in 0.5 ml dog plasma. In addition, good linearity (R2>0.9999) was also observed in urine, bile fluid, feces samples and various tissue samples. The overall accuracy of this method was 93-110% for both rat plasma and dog plasma. Intra-assay and inter-assay variabilities were less than 15.03% in plasma. The lowest quantitation limit of Astragaloside IV was 10 ng/ml in 0.5 ml rat plasma and 5 ng/ml in 0.5 ml dog plasma, respectively. Practical utility of this new LC/MS/MS method was confirmed in pilot pharmacokinetic studies in both rats and dogs following intravenous administration.  相似文献   

8.
A new HPLC method for the simultaneous determination of celecoxib, carboxycelecoxib and hydroxycelecoxib in human plasma samples has been developed. Following a solid-phase extraction procedure, the samples were separated by gradient reversed-phase HLPC (C(18)) and quantified using UV detection at 254 nm. The method was linear over the concentration range 10-500 ng/ml. The intra-assay variability for the three analytes ranged from 4.0 to 12.6% and the inter-assay variability from 4.9 to 14.2%. The achieved limits of quantitation (LOQ) of 10 ng/ml for each analyte allowed the determination of the pharmacokinetic parameters of the analytes after administration of 100 mg celecoxib.  相似文献   

9.
Tubeimoside I is an important component isolated from Bolbostemma paniculatum. Tubeimoside I has been demonstrated to possess many pharmacological activities, including anti-inflammatory, antitumor, and antitumor-promoting effects. The purpose of the present study was to examine in vivo pharmacokinetics and bioavailability of tubeimoside I in rats by using a liquid chromatography coupled with mass spectrometry quantitative detection method (LC/MS). The plasma samples were deproteinated, evaporated and reconstituted in 100 microl methanol prior to analysis. The separation was performed by Waters Symmetry C18 reversed-phase column (3.5 microm, 150 mm x 2.1mm, Waters Inc., USA) and a SB-C18 guard column (5 microm, 20 mm x 4.0mm). The mobile phase was a mixture of acetonitrile and water containing 5 microM NaAc (60:40, v/v). The method was validated within the concentration range 20-5000 ng/ml, and the calibration curves were linear with correlation coefficients >0.999. The lowest limit of quantitation (LLOQ) for tubeimoside I was 20 ng/ml in 0.1 ml rat plasma. The intra-assay accuracy and precision ranged from 92.4 to 104.9% and from 5.8 to 10.5%, respectively, while inter-assay accuracy and precision ranged from 94.2 to 95.0% and from 5.1 to 8.8%, respectively. The method was further applied to assess pharmacokinetics and oral bioavailability of tubeimoside I after intravenous and oral administration to rats. The oral bioavailability of tubeimoside I is only 0.23%, which indicates that tubeimoside I has poor absorption or undergoes acid-induced degradation. Practical utility of this new LC/MS method was confirmed in pilot pharmacokinetic studies in rats following both intravenous and oral administration.  相似文献   

10.
A rapid, sensitive and robust sample preparation procedure for the quantitative determination of indinavir in human cerebrospinal fluid (CSF) and plasma is described. Indinavir and the internal standard were isolated from CSF or plasma samples by cation-exchange solid-phase extraction with SCX cartridges, while the chromatographic separation was adopted from a previous method, using a cyano column connected by a switching valve to a C18 column. UV detection was set at 210 nm. The standard curve was linear over the concentration range of 2 to 2000 ng/ml in CSF and 5 to 2000 ng/ml in plasma. The intra-day coefficients of variation at all concentration levels were ≤5.9%. The inter-day consistency was assessed by running QC samples during each daily run. The coefficients of variation for quality control samples in both matrixes were ≤6.1%. The method has been utilized to support clinical pharmacokinetic studies.  相似文献   

11.
A method using gas chromatography-mass spectrometry (GC-MS) and solid-phase extraction (SPE) was developed for the determination of ajulemic acid (AJA), a non-psychoactive synthetic cannabinoid with interesting therapeutic potential, in human plasma. When using two calibration graphs, the assay linearity ranged from 10 to 750 ng/ml, and 750 to 3000 ng/ml AJA. The intra- and inter-day precision (R.S.D., %), assessed across the linear ranges of the assay, was between 1.5 and 7.0, and 3.6 and 7.9, respectively. The limit of quantitation (LOQ) was 10 ng/ml. The amount of AJA glucuronide was determined by calculating the difference in the AJA concentration before ("free AJA") and after enzymatic hydrolysis ("total AJA"). The present method was used within a clinical study on 21 patients suffering from neuropathic pain with hyperalgesia and allodynia. For example, plasma levels of 599.4+/-37.2 ng/ml (mean+/-R.S.D., n=9) AJA were obtained for samples taken 2 h after the administration of an oral dose of 20 mg AJA. The mean AJA glucuronide concentration at 2h was 63.8+/-127.9 ng/ml.  相似文献   

12.
A specific high performance liquid chromatography-mass spectrometric (LC-MS/MS) assay was developed for the determination of captopryl in plasma. The retention time was 1.45 and 1.37 min for captopril and enalapril, respectively. The overall mean recovery, using SPE extraction with OASIS HLB cartridges, was found to be 107.2+/-9.5 and 100.04+/-2%, respectively. Calibration curves were linear in the concentration range of 10.00-2000.00 ng/ml, and the lower limit of quantification (LLOQ) was 10.00 ng/ml. The LLOQ was sensitive enough for detecting terminal phase concentrations of the drug. Inter-batch precision of the method ranged from 0.88 to 1.95%. Intra-batch accuracy ranged from 97.15 to 105.77%, while intra-batch precision ranged from 2.49 to 5.66% at concentrations of 30.00, 760.00 and 1500.00 ng/ml. The developed method was applied to study bioequivalence of captopril in a group of 25 human subjects at a single oral dose of a 50mg tablet.  相似文献   

13.
A quantitative thin-layer chromatography (TLC) procedure is described for the analysis of cinromide (3-bromo-N-ethylcinnamamide) and its two major metabolites, 3-bromocinnamamide and 3-bromocinnamic acid in plasma of the dog. These compounds were recovered from acidified plasma by extraction into benzene with a recovery of 95 ± 5%. All three compounds were quantitated directly on a TLC plate by ultraviolet absorbance densitometry at 270 nm. The linear dynamic range for the quantitation of the compounds on a TLC plate ranged between 10 and 1000 ng. The complete procedure is useful in the working range of 50 ng/ml to 100 μg/ml of plasma with a coefficient of variability of about 10%. Specificity of the method for parent drug and each of its plasma metabolites was confirmed by high-performance liquid chromatography. The method was used to determine the pharmacokinetics of cinromide and its two major plasma metabolites in dogs following a single oral dose of the drug.  相似文献   

14.
A new, simple and rapid high-performance liquid chromatography (HPLC) method with UV detection has been developed for the determination of apovincaminic acid in human plasma. Apovincaminic acid and internal standard were isolated from plasma samples by solid-phase extraction with OASIS HLB cartridges. The chromatographic separation was accomplished on a reversed-phase C(18) column and UV detection was set at 311 nm. The calibration curves were linear in the concentration range of 2.4-240.0 ng/ml, and the limits of quantification was 2.4 ng/ml. The precision and accuracy ranged from 0.84 to 8.54% and 91.5 to 108.3%, respectively. The developed method was subsequently applied to study the pharmacokinetics of apovincaminic acid in a group of 20 human subjects at a single oral dose of 10mg of vinpocetine tablet.  相似文献   

15.
A simple and sensitive gas chromatographic method has been developed for the determination of timolol in plasma using electron-capture detection and propranolol as internal standard. Timolol was extracted using butyl chloride and derivatized using trifluoroacetic anhydride in butyl acetate. The lower detection limit for the assay was found to be 1 ng/ml from 1 ml of plasma. Extracted standards gave within-day precision of 12.55, 9.68 and 3.78% for 1, 20 and 100 ng/ml plasma samples, respectively. A recovery of at least 80% of timolol was found using the extraction method described. The assay was used in a randomized cross-over bioequivalence trial using an oral administration of 20 mg of timolol. Pharmacokinetic parameters compare favourably with other literature values.  相似文献   

16.
A simple liquid chromatographic method was developed for the simultaneous determination of flavonoids from Orthosiphon stamineus Benth, namely sinensitin, eupatorin and 3'-hydroxy-5,6,7,4'-tetramethoxyflavone, in plasma. Prior to analysis, the flavonoids and the internal standard (naproxen) were extracted from plasma samples using a 1:1 mixture of ethyl acetate and chloroform. The detection and quantification limits for the three flavonoids were similar being 3 and 5 ng/ml, respectively. The within-day and between-day accuracy values, expressed as percentage of true values, for the three flavonoids were between 95 and 107%, while the corresponding precision, expressed as coefficients of variation, for the three flavonoids were less than 14%. In addition, the mean recovery values of the extraction procedure for all the flavonoids were between 92 and 114%. The calibration curves were linear over a concentration range of 5-4000 ng/ml. The present method was applied to analyse plasma samples obtained from a pilot study using rats in which the mean absolute oral bioavailability values for sinensitin, eupatorin and 3'-hydroxy-5,6,7,4'-tetramethoxyflavone was 9.4, 1.0 and 1.5%, respectively.  相似文献   

17.
A simple, rapid and reliable method was developed for the quantification of oxymatrine (OMT) and its metabolite matrine (MT) in beagle dog plasma using a liquid-liquid extraction procedure followed by liquid chromatography-electrospray ionization mass spectrometric (LC-ESI-MS) analysis. Extend-C18 column (2.1 mm i.d. x 50 mm, 5 microm) with a C18 guard column (2.1 mm i.d. x 12.5 mm) was used as the analytical column. Linear detection responses were obtained for OMT concentration ranging from 5 to 4000 ng/ml and for MT concentration ranging from 5 to 2000 ng/ml. The precision and accuracy data, based on intra- and inter-day variations over 5 days, were lower than 5%. The limit of quantitation for OMT and MT were 2 and 1 ng/ml, respectively, and their recoveries were greater than 90%. Pharmacokinetic data of OMT and its active metabolite MT obtained with this method following a single oral dose of 300 mg OMT capsules to six beagle dogs was also reported for the first time.  相似文献   

18.
A simple extraction procedure and a sensitive high-performance liquid chromatographic (HPLC) method are described for the determination of the photodynamic therapeutic agent 5, 10, 15, 20-tetra(m-hydroxyphenyl)chlorin (mTHPC) in plasma and tumour tissue. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70×4.6 mm I.D.) with a mobile phase of 0.01 M potassium dihydrogenphosphate buffer, pH 2.5-acetonitrile (55:45, v/v) and a coulometric detection (+0.80 V). The mean recoveries of mTHPC in the concentration ranges (5–2000 and 10–1000 ng/ml) were 90 and 89% for plasma and tumour samples, respectively. The procedure for plasma and tissue preparation involved solvent precipitation using methanol combined with ammonia solution and dimethyl sulphoxide (4, 0.2, 0.1, v/v/v) and (2, 0.1, 0.1, v/v/v) for plasma and tissue, respectively. For mTHPC at concentrations ranging from 5 to 2000 ng/ml, the within-day relative standard deviations, based on triplicate determinations were less than 8% and the between-day relative standard deviations calculated by performing extraction procedure of plasma samples on three different days ranged from 3 to 18%. This highly sensitive method, 5 and 10 ng/ml for plasma and tissue respectively, was applied successfully to the determination of mTHPC in mouse tumours for pharmacokinetic studies.  相似文献   

19.
Two methods for the extraction of morphine from cerebrospinal fluid or plasma with quantitation by high-performance liquid chromatography with electrochemical detection were compared for accuracy, precision and ease of preparation. One procedure was a standard extraction procedure and the other utilized a commercially available liquid—liquid extraction column. Both methods produced linear calibration curves over the concentration range of 1–200 ng/ml with coefficients of correlation of 0.999. Since the electrochemical detector is capable of detecting 20 pg of morphine, biological samples as small as 0.1 to 0.4 ml can be quantified with an average relative precision of 4.1 ± 3.9% over the concentration range 1–200 ng/ml. The potential clinical importance of the assay is demonstrated using a time course distribution study of morphine in the cerebrospinal fluid and plasma of a Rhesus monkey.  相似文献   

20.
A simple, precise and sensitive high performance liquid chromatography procedure has been developed for determination of carvedilol in human plasma. The method was developed on Lichrosphere R CN column using a mobile phase of acetonitrile/20 mM ammonium acetate buffer with 0.1% triethylamine (pH adjusted to 4.5) (40/60, v/v). The peaks were detected by using fluorescence detector (excitation wavelength 282 nm and emission wavelength 340 nm). Carvedilol and domperidone (internal standard) were extracted by liquid-liquid extraction procedure using dichloromethane. This method was specific and had a linearity range of 1-128 ng/ml with intra- and inter-day precision (%C.V.) less than 15%. The accuracy ranges from 87.3 to 100.88% and the recovery of carvedilol was 69.90%. The stability studies showed that carvedilol in human plasma was stable during short-term period for sample preparation and analysis. This method was used to assay the carvedilol in human plasma samples obtained from subjects who had been given an oral tablet of 12.5 mg carvedilol.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号