首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A biphasic monolithic capillary column with 10 cm segment of strong-cation exchange monolith and 65 cm segment of reversed-phase monolith was prepared within a single 100 microm i.d. capillary. Separation performance of this column was evaluated by a five-cycle online multidimensional separation of 10 microg tryptic digest of yeast proteins using nanoflow liquid chromatography coupled with tandem mass spectrometry, and it took 12 h for whole separation under the operating pressure only approximately 900 psi. Totally, 780 distinct proteins were positively identified through assignment of 2953 unique peptides at false-positive rate less than 1%. The good separation performance of this biphasic column was largely attributed to the good orthogonality of the strong-cation exchange monolith and reversed-phase monolith for multidimensional separation.  相似文献   

2.
Weak cation-exchange (WCX) and HILIC modes columns were prepared by on-column polymerization of acrylic acid on monolithic silica capillary columns modified with N-(3-triethoxysilylpropyl)methacrylamide anchor groups. The polymer-coated columns could be used for HILIC mode separation of pyridylamino (PA)-sugars and peptides including a tryptic digest of BSA, while for weak cation-exchange mode for the separation of proteins and nucleosides even at high linear velocity. The poly(acrylic acid) coated monolithic silica capillary columns showed greater retention toward PA-sugars than a polyacrylamide coated monolithic silica capillary columns prepared in the same manner. Proteins and nucleosides were separated effectively at pH 6.9 using the same column. The column provided fair permeability after the polymer-coating step. High-speed separation of proteins at u=4.66 mm/s with high efficiency was shown to be possible, while high-speed separation of nucleosides has achieved within one minute using the column at u=8.67 mm/s, suggesting that the column will be suitable for the second dimension separation of multidimensional HPLC systems.  相似文献   

3.
Feng S  Pan C  Jiang X  Xu S  Zhou H  Ye M  Zou H 《Proteomics》2007,7(3):351-360
Immobilized metal affinity chromatography (IMAC) is a commonly used technique for phosphoproteome analysis due to its high affinity for adsorption of phosphopeptides. Miniaturization of IMAC column is essential for the analysis of a small amount of sample. Nanoscale IMAC column was prepared by chemical modification of silica monolith with iminodiacetic acid (IDA) followed by the immobilization of Fe3+ ion inside the capillary. It was demonstrated that Fe3+-IDA silica monolithic IMAC capillary column could specifically capture the phosphopeptides from tryptic digest of alpha-casein with analysis by MALDI-TOF MS. The silica monolithic IMAC capillary column was manually coupled with nanoflow RPLC/nanospray ESI mass spectrometer (muRPLC-nanoESI MS) for phosphoproteome analysis. The system was validated by analysis of standard phosphoproteins and then it was applied to the analysis of protein phosphorylation in mouse liver lysate. Besides MS/MS spectra, MS/MS/MS spectra were also collected for neutral loss peak. After database search and manual validation with conservative criteria, 29 singly phosphorylated peptides were identified by analyzing a tryptic digest of only 12 mug mouse liver lysate. The results demonstrated that the silica monolithic IMAC capillary column coupled with muRPLC-nanoESI MS was very suitable for the phosphoproteome analysis of minute sample.  相似文献   

4.
The use and applicability of silica based capillary monolithic reversed-phase columns in proteomic analysis has been evaluated by liquid chromatography-mass spectrometry (LC-MS). Chromatographic performance of the monolithic capillaries was evaluated with a tryptic digest of cytochrome C showing very good resolution and reproducibility in addition to the known advantages of a low pressure drop over a time period of 6 months. Monoliths were subsequently tested for their suitability to separate proteins and peptides from samples typically encountered in proteomic research such as in-gel digested tryptic peptide mixtures or fractions of proteolytically digested human serum. The monolithic capillaries also proved useful in the analysis of phospholipid species in bronchoalveolar lavage fluid. Compared to particle-filled conventional capillary columns, rapid and highly efficient separation of peptides and proteins was achieved using these bimodal pore size distribution columns, and good quality collision induced dissociation (CID) mass spectra were obtained on an ion trap mass spectrometer. These novel monolithic separation media are thus a promising addition to the methodological toolbox of proteomics research.  相似文献   

5.
Weak cation-exchange (WCX) and HILIC modes columns were prepared by on-column polymerization of acrylic acid on monolithic silica capillary columns modified with N-(3-triethoxysilylpropyl)methacrylamide anchor groups. The polymer-coated columns could be used for HILIC mode separation of pyridylamino (PA)-sugars and peptides including a tryptic digest of BSA, while for weak cation-exchange mode for the separation of proteins and nucleosides even at high linear velocity. The poly(acrylic acid) coated monolithic silica capillary columns showed greater retention toward PA-sugars than a polyacrylamide coated monolithic silica capillary columns prepared in the same manner. Proteins and nucleosides were separated effectively at pH 6.9 using the same column. The column provided fair permeability after the polymer-coating step. High-speed separation of proteins at u = 4.66 mm/s with high efficiency was shown to be possible, while high-speed separation of nucleosides has achieved within one minute using the column at u = 8.67 mm/s, suggesting that the column will be suitable for the second dimension separation of multidimensional HPLC systems.  相似文献   

6.
The HPLC/MS system, in which a monolithic silica capillary column is directly connected to an electronspray-ionization mass spectrometer, showed superior performance at high mobile phase linear velocity. A two-dimensional (2D) HPLC/MS system was established, using an ion-exchange particle-packed capillary column at the first dimension and a monolithic silica capillary column at the second dimension. In an analysis of tryptic fragments from bovine serum albumin, an 81% sequence coverage, obtained by the 2D-HPLC/MS system, increased by 23% as compared to a 1D-HPLC/MS system. This 2D-HPLC/MS system using a monolithic silica capillary column should be useful for enhancing sequence coverage of tryptic fragments in proteomics.  相似文献   

7.
The HPLC/MS system, in which a monolithic silica capillary column is directly connected to an electronspray-ionization mass spectrometer, showed superior performance at high mobile phase linear velocity. A two-dimensional (2D) HPLC/MS system was established, using an ion-exchange particle-packed capillary column at the first dimension and a monolithic silica capillary column at the second dimension. In an analysis of tryptic fragments from bovine serum albumin, an 81% sequence coverage, obtained by the 2D-HPLC/MS system, increased by 23% as compared to a 1D-HPLC/MS system. This 2D-HPLC/MS system using a monolithic silica capillary column should be useful for enhancing sequence coverage of tryptic fragments in proteomics.  相似文献   

8.
Various methods are used to enrich or purify a protein of interest from other proteins and components in a crude cell lysate or other sample. One of the most powerful methods is affinity purification, also called affinity chromatography, whereby the proteins of interest are purified by virtue of their specific binding properties to an immobilized ligand. Affinity purification is becoming more widely used for exploring post-translation modifications and protein-protein interactions, especially with a view toward developing new general tag systems and strategies of chemical derivatization on peptides for affinity selection. Our work was aimed to immobilize proteins or ligands for affinity purification of antibodies, fusion-tagged proteins and other proteins and peptides. Selected proteins or peptides are efficiently extracted and enriched using chemically derivatized walls of a fused silica capillary column. In this paper, we present an open tubular capillary, where the inner wall of a fused silica capillary was derivatized by covalent binding of modified polystyrene latex particles. The capillaries were derivatized with iminodiacetic acid and loaded with Fe3+ or Ni2+ for the purification and enrichment of phosphopeptides or His-tagged proteins, respectively. The latex coated capillaries have been successfully applied to enrich phosphopeptides from beta-casein tryptic digest and ovalbumin tryptic digest at a micro volume scale with recoveries ranging from 92 to 95%. The capillaries have been eluted under conditions compatible with MALDI-MS without any prior desalting step. In another approach, concanavalin A (Con A) or Protein G were immobilized on the epoxy modified latex on the inner wall of the fused silica capillary for the purification of glycoproteins and immunoglobulin, respectively. The design of the capillary and the protocols used for purification permits the direct detection of eluted proteins and peptides with gel electrophoresis or with mass spectrometry. The elution volumes are passed as discrete segments of few microliters over the inner surface of the open-tube capillary, achieving enrichment factors of more than 20-fold from starting samples.  相似文献   

9.
A novel frit preparation method for one‐end tapered‐fused silica‐packed capillary columns in nano‐LC‐ESI MS was developed. A hollow‐fused silica capillary column with a tapered tip as nano‐spray emitter was filled with 5 μm C18 beads, and then a sintered frit about 0.25 mm in length was prepared at the tip by butane flame. A stainless steel protection tube with 0.5 mm id was used to control the length of the frit and to protect the packed C18 beads behind the sintered frit during the sintering. C18 sintered frits were evaluated by BSA tryptic digests with nano‐LC‐LTQ. The sintered frits did not produce post‐column band broadening due to very small volume (about 0.2 nL) and did not produce adsorption to sample. The sintered frit columns had good separation reproducibility and separation performance compared with self‐assembled particles frit columns and commercial columns.  相似文献   

10.
A chiral capillary monolithic column for capillary electrochromatography (CEC) was prepared by covalent bonding of cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC) on the silica monolithic matrix within the confine of a 50-microm i.d. bare fused silica capillary. Several pairs of enantiomers including neutral and basic analytes were baseline resolved on the newly prepared chiral capillary monolithic column in CEC with aqueous mobile phases. Fast enantioseparation was achieved due to the favorable dynamic properties of silica monolith. The covalent bonding of CDMPC as the chiral stationary phase for CEC also enabled the use of THF in mobile phase for enantioseparation of prazquantel by overcoming the incompatibility of THF and the physically coated CDMPC on a column.  相似文献   

11.
Jiang X  Feng S  Tian R  Han G  Jiang X  Ye M  Zou H 《Proteomics》2007,7(4):528-539
An approach was developed to automate sample introduction for nanoflow LC-MS/MS (microLC-MS/MS) analysis using a strong cation exchange (SCX) trap column. The system consisted of a 100 microm id x 2 cm SCX trap column and a 75 microm id x 12 cm C18 RP analytical column. During the sample loading step, the flow passing through the SCX trap column was directed to waste for loading a large volume of sample at high flow rate. Then the peptides bound on the SCX trap column were eluted onto the RP analytical column by a high salt buffer followed by RP chromatographic separation of the peptides at nanoliter flow rate. It was observed that higher performance of separation could be achieved with the system using SCX trap column than with the system using C18 trap column. The high proteomic coverage using this approach was demonstrated in the analysis of tryptic digest of BSA and yeast cell lysate. In addition, this system was also applied to two-dimensional separation of tryptic digest of human hepatocellular carcinoma cell line SMMC-7721 for large scale proteome analysis. This system was fully automated and required minimum changes on current microLC-MS/MS system. This system represented a promising platform for routine proteome analysis.  相似文献   

12.
Myxobacteria are potent producers of secondary metabolites exhibiting diverse biological activities and pharmacological potential. The proteome of Myxococcus xanthus DK1622 was characterized by two-dimensional chromatographic separation of tryptic peptides from a lysate followed by tandem mass spectrometric identification. The high degree of orthogonality of the separation system employing polymer-based strong cation-exchange and monolithic reversed-phase stationary phases was clearly demonstrated. Upon automated database searching, 1312 unique peptides were identified, which were associated with 631 unique proteins. High-molecular polyketide synthetases and nonribosomal peptide synthetases, known to be involved in the biosynthesis of various secondary metabolites, were readily detected. Besides the identification of gene products associated with the production of known secondary metabolites, proteins could also be identified for six gene clusters, for which no biosynthetic product has been known so far.  相似文献   

13.
A system of capillary silica monolith with bovine serum albumin (BSA) functionalized through two approaches for affinity monolithic capillary electrochromatography (AMCEC) was developed. Covalent immobilization conditions for two different Schiff base methods, which employed 3-glycidopropyl trimethoxysilane (GPTS) and 3-aminopropyl trimethoxysilane (APTS) as starting materials, respectively, were investigated to obtain good and stable chiral separation. The BSA immobilized silica monoliths were evaluated in terms of morphology, electroosmotic flow, retention time, column efficiency and resolution of model compound (±)-tryptophan. The columns exhibited satisfactory run-to-run, column-to-column repeatability and maintained their enantioselectivity for more than 3 months. Both developed methods can baseline separate tryptophan enantiomers, whereas shorter retention time, better column efficiency, and enantiomeric recognition between two pairs of drug enantiomers (pantoprazole and atenolol) were obtained by the GPTS method.  相似文献   

14.
The sensitivity of proteomics measurements using liquid chromatography (LC) separations interfaced with electrospray ionization-mass spectrometry (ESI-MS) improves approximately inversely with liquid flow rate (for the columns having the same separation efficiency, linear velocity, and porosity), making attractive the use of smaller inner diameter LC columns. We report the development and initial application of 10 microm i.d. silica-based monolithic LC columns providing more sensitive proteomics measurements. A 50-microm-i.d. micro solid-phase extraction precolumn was used for ease of sample injection and cleanup prior to the reversed-phase LC separation, enabling the sample volume loading speed to be increased by approximately 50-fold. Greater than 10-fold improvement in sensitivity was obtained compared to analyses using more conventional capillary LC, enabling e.g. the identification of >5000 different peptides by MS/MS from 100-ng of a Shewanella oneidensis tryptic digest using an ion trap MS. The low nL/min LC flow rates provide more uniform responses for different peptides, and provided improved quantitative measurements compared to conventional separation systems without the use of internal standards or isotopic labeling. The improved sensitivity allowed LC-MS measurements of immunopurified protein phosphatase 5 that were in good agreement with quantitative Western blot analyses.  相似文献   

15.
A high-throughput on-line capillary array-based two-dimensional liquid chromatography (2D-LC) system coupled with MALDI-TOF-TOF-MS proteomics analyzer for comprehensive proteomic analyses has been developed, in which one capillary strong-cation exchange (SCX) chromatographic column was used as the first separation dimension and 18 parallel capillary reversed-phase liquid chromatographic (RPLC) columns were integrated as the second separation dimension. Peptides bound to the SCX phase were "stepped" off using multiple salt pulses followed by sequentially loading of each subset of peptides onto the corresponding precolumns. After salt fractionation, by directing identically split solvent-gradient flows into 18 channels, peptide fractions were concurrently back-flushed from the precolumns and separated simultaneously with 18 capillary RP columns. LC effluents were directly deposited onto the MALDI target plates through an array of capillary tips at a 15-s interval, and then alpha-cyano-4-hydroxycinnamic acid (CHCA) matrix solution was added to each sample spot for subsequent MALDI experiments. This new system allows an 18-fold increase in throughput compared with serial-based 2D-LC system. The high efficiency of the overall system was demonstrated by the analysis of a tryptic digest of proteins extracted from normal human liver tissue. A total of 462 proteins was identified, which proved the system's promising potential for high-throughput analysis and application in proteomics.  相似文献   

16.
High throughput methods (high performance liquid chromatography and capillary electrophoresis) were developed to determine pravastatin in production media. The analyses were performed on particle column, monolithic column and silica capillary filled with borate buffer pH 9.3 containing 20 mM SDS. All three methods successfully separate pravastatin from interfering compounds (matrix, mevastatin and 6-epi pravastatin) and runtimes are shorter than 1 min. Solvent consumptions for methods using small particle column, monolith column and MECK were 132, 510 and 1.5 mL h(-1). The most sensitive was the method using particle column (LOD was about 10(-5) mg mL(-1)), followed by the system using monolith column (LOD was 2 x 10(-4) mg mL(-1)) and the MECK method (LOD was about 0.02 mg mL(-1)).  相似文献   

17.
An enzymatic microreactor with a volume of 470 nL has been prepared by immobilizing trypsin on a 10 cm long reactive porous polymer monolith located in a 100 microm i.d. fused silica capillary. This reactor affords suitable degrees of digestion of proteins even after very short residence times of less than 1 min. The performance is demonstrated with the digestion of eight proteins ranging in molecular mass from 2848 to 77 754. The digests were analyzed using mass spectrometry in two modes: off-line MALDI and in-line nanoelectrospray ionization. The large numbers of identified peptides enable a high degree of sequence coverage and positive identification of the proteins. The extent of sequence coverage decreases as the molecular mass of the digested protein increases.  相似文献   

18.
An integrated platform consisting of monolithic immobilized pH gradient-based capillary isoelectric focusing (M-IPG CIEF) and capillary zone electrophoresis (CZE) coupled by a partially etched porous interface was established. Since carrier ampholytes (CAs) were immobilized on monolith in M-IPG CIEF to form a stable pH gradient, subsequent depletion of CAs at the interface to prevent the interference on CZE separation and detection were avoided. Moreover, a partially etched porous capillary column, which was facile for fabrication and durable for operation, was exploited as the interface to combine M-IPG CIEF and CZE. The RSD values in terms of the migration time for M-IPG CIEF separation, transfer protein from the first dimension to the second dimension, and CZE separation, were 2.4%, 3.9% and 2.3%, respectively. With a 6-protein mixture as the sample, two-dimensional capillary electrophoresis (2D-CE) separation was successfully completed within 116 min, yielding a peak capacity of ~200 even with minute sample amount down to 5.0 μg/mL. The limit of detection was 0.2 μg/mL. In addition, proteins extracted from milk were used to test the performance of such a 2D-CE separation platform. We expect that such a novel 2D-CE system would provide a promising tool for protein separation with high throughput and high peak capacity.  相似文献   

19.
A simple method for the preparation of an affinity monolithic (also called continuous bed) capillary column for alpha-mannose-specific lectins is described. 2-Hydroxyethyl methacrylate in combination with (+)-N,N -diallyltartardiamide (DATD) and piperazine diacrylamide (PDA, 1,4-bisacryloyl-piperazine) as crosslinkers, were used as monomers for the monolith. After oxidation of DATD with periodate, alpha-mannose with spacer was bound to the aldehyde groups of the polymeric skeleton via reductive amination to form an affinity column for the separation, enrichment or binding studies of mannose-specific lectins. The permeability of the column was excellent. The porosity of the monolith was investigated by scanning electron microscope (SEM) and inverse size exclusion chromatography (ISEC). The affinity of the monolith was evaluated by frontal analysis (FA) and fluorescence microscopy (FM) using fluorescently labeled concanavalin (Con A). Frontal affinity chromatography showed a specific interaction of two different lectins with the alpha-mannose-modified monolith. According to FM the affinity sites were evenly distributed over the monolithic bed.  相似文献   

20.
毛细管区带电泳/串联质谱联用法鉴定多肽和蛋白质   总被引:11,自引:3,他引:8  
建立了毛细管区带电泳-串联质谱联用(CZE/MS/MS)对多肽和蛋白质高灵敏度鉴定方法,对Met-脑啡肽和Leu-脑啡肽的混合物进行了分析,用CZE/MS/MS方法验证了各自的序列,同样对细胞色素c的胰蛋白酶酶解产物用CZE/MS/MS方法进行了肽质谱分析,几科所有肽段的序列及其与在分子中的位置都得到了确定,通过SEQUEST软件进行蛋白质序列数据库搜索得到准确的鉴定结果,所消耗的样品量均在低皮可  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号