首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Determination of telomere length is traditionally performed by Southern blotting and densitometry, giving a mean telomere restriction fragment (TRF) value for the total cell population studied. Fluorescence in situ hybridization (FISH) of telomere repeats has been used to calculate telomere length, a method called quantitative (Q)-FISH. We here present a quantitative flow cytometric approach, Q-FISHFCM, for evaluation of telomere length distribution in individual cells based on in situ hybridization using a fluorescein-labeled peptide nucleic acid (PNA) (CCCTAA)3probe and DNA staining with propidium iodide. A simple and rapid protocol with results within 30 h was developed giving high reproducibility. One important feature of the protocol was the use of an internal cell line control, giving an automatic compensation for potential differences in the hybridization steps. This protocol was tested successfully on cell lines and clinical samples from bone marrow, blood, lymph nodes and tonsils. A significant correlation was found between Southern blotting and Q-FISHFCMtelomere length values ( P = 0.002). The mean sub-telomeric DNA length of the tested cell lines and clinical samples was estimated to be 3.2 kbp. With the Q-FISHFCMmethod the fluorescence signal could be determined in different cell cycle phases, indicating that in human cells the vast majority of telomeric DNA is replicated early in S phase.  相似文献   

3.
P E H?nninen  J T Soini  E Soini 《Cytometry》1999,36(3):183-188
We studied the use of a dramatically reduced testing zone in combination with two-photon excitation and photon-burst analysis in high-throughput rare-event detection simulation using a modified flow cytometer. Two-photon excitation measurements were performed with a mode-locked titanium:sapphire laser. Fluorescence emission was measured with a photon-counting avalanche photodiode. Measured signal was analysed offline by autocorrelation and burst detection methods. Test samples were composed of full blood and orange fluorescent polystyrene nanospheres mixed in full blood. Results show that two-photon fluorescence excitation and time-correlation analysis provide a good signal-to-noise ratio for rare-event particle detection in a turbid sample environment.  相似文献   

4.
The analysis of membrane surface immunoglobulin (SmIg) on B lymphocytes was carried out in 59 normal individuals and nine patients with B-cell non-Hodgkin's lymphomas by conventional immunofluorescence microscopy and flow cytometry. Five channel settings of a cytofluorograph were evaluated (100, 150, 200, 250, 300) and the mean and standard deviation of the percent positive cells were calculated and compared to the mean and standard deviation of the microscope reading. On the basis of the relative fluorescence reactivity, we were able to determine a fluorescence intensity at which the results of flow cytometry and fluorescence microscopy were comparable. In normal individuals, for cells expressing surface Ia, the channel giving similar results to that of fluorescence microscopy was 150; for kappa and lambda chains, channel 200; for Fab'PV, channel 200; and for IgM, channel 250. In patients with B-cell non-Hodgkin's lymphomas, for cells expressing surface Ia the channel giving similar results to that of fluorescence microscopy was 100; for kappa, channel 100; for lambda, channel 200; for Fab'FV, channel 150; and for IgM, channel 150. Flow cytometric analysis of SmIg appears to be superior to fluorescence microscopy in efficiency, and has the added advantages of being a rapid, sensitive, and objectively quantitative methodology.  相似文献   

5.
A C Begg  I Hofland 《Cytometry》1991,12(5):445-454
The development of antibodies to DNA-incorporated thymidine analogs has in turn led to the development of flow cytometric techniques for rapidly measuring cell kinetics parameters. More recently, these techniques have been applied to clinical tumor material. One problem with such measurements has been the difficulty of distinguishing malignant cells from coexistent normal cells in the biopsy material. In the present study, the feasibility of selecting out the desired malignant cell population for kinetic analysis from a mixture of cells was tested in vitro. An anticytokeratin antibody was used to discriminate between a mixture of tumor cells (cytokeratin positive) and normal cells (cytokeratin negative). The cell lines chosen for the study, A549 human lung carcinoma cells and Chinese hamster ovary (CHO) cells, were pulse labeled with iododeoxyuridine (IdUrd) and sampled every hour up to 16 hours. Selecting out cells from the mixture required the application of three-color fluorescence flow cytometry, which was carried out using the fluorochromes FITC (fluorescein isothionate, green fluorescence, IdUrd-DNA antibody), PE (phycoerythrin, orange fluorescence, cytokeratin antibody), and PI (propidium iodide, red fluorescence, DNA). This allowed single laser excitation. The staining procedure involved incubation with the IdUrd antibodies (specific antibody plus FITC-conjugated second antibody) followed by the cytokeratin antibodies (specific antibody plus PE-conjugated second antibody) and lastly by the DNA stain containing RNase. Two analysis methods of the IdUrd/DNA cytograms were applied: a mid-S window analysis and a relative movement (RM) analysis. Results of the analyses for cells selected out of mixtures were compared with results of cells stained and analyzed separately. A clear separation of the two cell lines could be obtained on the basis of orange fluorescence (cytokeratin content) despite a large overlap of their DNA histograms. By gating on high or low orange fluorescence, almost pure populations of the individual cell types could be selected out for further kinetic analysis. Little difference was seen, with both the mid-S and RM analyses, between cells gated from mixtures or stained separately. It is concluded that this technique is feasible for use on clinical material, provided good cell suspensions can be obtained, leading to the hope of increasing the accuracy of kinetic measurements on human tumors.  相似文献   

6.
Mitochondrial membrane permeabilization (MMP) is a key event in necrotic and (intrinsic) apoptotic processes. MMP is controlled by a few major rate-limiting events, one of which is opening of the permeability transition pore (PTP). Here we develop a flow cytometry (FC)-based approach to screen and study inducers and blockers of MMP in isolated mitochondria. Fixed-time and real-time FC permits to co-evaluate and order modifications of mitochondrial size, structure and inner membrane (IM) electrochemical potential (DeltaPsi(m)) during MMP. Calcium, a major PTP opener, and alamethicin, a PTP-independent MMP inducer, trigger significant mitochondrial forward scatter (FSC) increase and side scatter (SSC) decrease, correlating with spectrophotometrically detected swelling. FC-based fluorescence detection of the DeltaPsi(m)-sensitive cationic lipophilic dye JC-1 permits to detect DeltaPsi(m) variations induced by PTP openers or specific inducers of inner MMP such as carbonylcyanide m-chlorophenylhydrazone (mClCCP). These simple, highly sensitive and quantitative FC-based methods will be pertinent to evaluate compounds for their ability to control MMP.  相似文献   

7.
Reticulocyte counting by flow cytometry with thiazole orange was compared to manual or automated counting of new methylene blue stained blood smears. Forty-nine samples were compared for manual counting from randomly chosen clinical samples. Two hundred and eighty-nine samples from bone marrow transplant patients were compared during the period before and through chemo-irradiation and engraftment. The slopes of correlation plots were less than 1 when flow cytometric data were the dependent variable, suggesting that thiazole orange is less sensitive than new methylene blue. In a third study, 407 samples from bone marrow transplant patients were compared after increasing the thiazole orange concentration. The reticulocyte fluorescence distribution was divided into four groups of the brightest (youngest) 40, 60, 80, and 100% of reticulocytes. The slopes from regression analysis were 0.25, 0.49, 0.78, and 1.14, respectively. This demonstrates that thiazole orange is more sensitive than new methylene blue because the window of analysis includes an increased fraction of mature reticulocytes. In addition, the precision of each assay as measured. The rank order of precision from high to low was flow cytometry > image analysis > manual counting.  相似文献   

8.
We present a high-throughput approach to study weak protein-protein interactions by coupling bimolecular fluorescent complementation (BiFC) to flow cytometry (FC). In BiFC, the interaction partners (bait and prey) are fused to two rationally designed fragments of a fluorescent protein, which recovers its function upon the binding of the interacting proteins. For weak protein-protein interactions, the detected fluorescence is proportional to the interaction strength, thereby allowing in vivo discrimination between closely related binders with different affinity for the bait protein. FC provides a method for high-speed multiparametric data acquisition and analysis; the assay is simple, thousands of cells can be analyzed in seconds and, if required, selected using fluorescence-activated cell sorting (FACS). The combination of both methods (BiFC-FC) provides a technically straightforward, fast and highly sensitive method to validate weak protein interactions and to screen and identify optimal ligands in biologically synthesized libraries. Once plasmids encoding the protein fusions have been obtained, the evaluation of a specific interaction, the generation of a library and selection of active partners using BiFC-FC can be accomplished in 5 weeks.  相似文献   

9.
The formylpeptide receptor (FPR) family of G protein-coupled receptors contributes to the localization and activation of tissue-damaging leukocytes at sites of chronic inflammation. Here we describe a high-throughput flow cytometry screening approach that has successfully identified multiple families of previously unknown FPR ligands. The assay detects active structures that block the binding of a fluorescent ligand to membrane FPR of intact cells, thus detecting both agonists and antagonists. It is homogeneous in that assay reagents are added in sequence and the wells are subsequently analyzed without intervening wash steps. Microplate wells are routinely processed at a rate of 40 wells per minute, requiring a volume of only 2 microl to be sampled from each. This screening approach has recently been extended to identify a high-affinity, selective agonist for the intracellular estrogen-binding G protein-coupled receptor GPR30. With the development of appropriate assay reagents, it may be generally adaptable to a wide range of receptors. The total time required for the assay ranges between 1.5 and 2.5 h. The time required for flow cytometry analysis of a 96-well plate at the end of the procedure is less than 2.5 min. By comparison, manual processing of 96 samples will typically require 40-50 min, and a fast commercial automated sampler processes 96-well plates in less than 15 min, requiring the aspiration of 22 microl per sample for an analysis volume of 2 microl.  相似文献   

10.
We describe a method for quantitatively determining the alpha- adrenergic receptor subtypes in membrane fractions by studying the displacement of [3H] dihydroergocryptine by selective alpha antagonists and analyzing this data by a computer modeling technique. Alpha1 receptors are those with a higher affinity for prazosin than for yohimbine; alpha2 receptors have a higher affinity for yohimbine than for prazosin. Phentolamine does not discriminate between the two receptor subtypes present in rabbit uterus. The alpha receptor population of rabbit uterus was found to be 37% alpha1 receptors and 63% alpha2 receptors. The human platelet and rat liver alpha receptors were determined to be exclusively alpha2 and alpha1, respectively. In the uterus, prazosin had a 8800 fold greater affinity for alpha1 than alpha2 receptors while yohimbine had a 510 fold greater affinity for alpha2 than alpha1 receptors. The use of [3H] dihydroergocryptine displacement curves generated with selective alpha receptor antagonists coupled with subsequent computer modeling provides a precise and powerful method for quantifying the alpha receptor population of a tissue; this technique should be of value in studying the detailed regulation of alpha receptors in tissues which have both alpha1 and alpha2 receptors.  相似文献   

11.
Quantitative two-color fluorescent analysis of Simian virus (SV40) infection of permissive CV-1 cells was investigated. Analysis included by quantitation of cellular DNA, the early viral tumor (T) antigen with a monoclonal antibody, and late viral (V) antigens with a polyclonal antibody. T antigen was detected in all phases of the cell cycle at 6 and 12 h, after SV40 infection of growth arrested cells. At later time intervals, the percentage of T-antigen-positive cells increased with the induction of the cells into successive rounds of DNA synthesis and an increase in tetraploid-polyploid cells. The amount of T antigen per cell increased as the cells entered the successive stages of the cell cycle (G0/G1----G2 + M----tetraploid S and G2 + M). The V antigen from adsorbed virus was detected immediately after infection. Synthesis of V antigen began in late S and G2 + M phases of the cell cycle. This quantitative analysis allows a definitive determination of antigen per cell in a population correlated with the cell cycle and may be useful in correlating viral and cellular events with transformation.  相似文献   

12.
13.

Background

In our previous study that characterized different human CD4+ lymphocyte preparations, it was found that both commercially available cryopreserved peripheral blood mononuclear cells (PBMC) and a commercially available lyophilized PBMC (Cyto-Trol™) preparation fulfilled a set of criteria for serving as biological calibrators for quantitative flow cytometry. However, the biomarker CD4 protein expression level measured for T helper cells from Cyto-Trol was about 16% lower than those for cryopreserved PBMC and fresh whole blood using flow cytometry and mass cytometry. A primary reason was hypothesized to be due to steric interference in anti- CD4 antibody binding to the smaller sized lyophilized control cells.

Method

Targeted multiple reaction monitoring (MRM) mass spectrometry (MS) is used to quantify the copy number of CD4 receptor protein per CD4+ lymphocyte. Scanning electron microscopy (SEM) is utilized to assist searching the underlying reasons for the observed difference in CD4 receptor copy number per cell determined by MRM MS and CD4 expression measured previously by flow cytometry.

Results

The copy number of CD4 receptor proteins on the surface of the CD4+ lymphocyte in cryopreserved PBMCs and in lyophilized control cells is determined to be (1.45 ± 0.09) × 105 and (0.85 ± 0.11) × 105, respectively, averaged over four signature peptides using MRM MS. In comparison with cryopreserved PBMCs, there are more variations in the CD4 copy number in lyophilized control cells determined based on each signature peptide. SEM images of CD4+ lymphocytes from lyophilized control cells are very different when compared to the CD4+ T cells from whole blood and cryopreserved PBMC.

Conclusion

Because of the lyophilization process applied to Cyto-Trol control cells, a lower CD4 density value, defined as the copy number of CD4 receptors per CD4+ lymphocyte, averaged over three different production lots is most likely explained by the loss of the CD4 receptors on damaged and/or broken microvilli where CD4 receptors reside. Steric hindrance of antibody binding and the association of CD4 receptors with other biomolecules likely contribute significantly to the nearly 50% lower CD4 receptor density value for cryopreserved PBMC determined from flow cytometry compared to the value obtained from MRM MS.

Electronic supplementary material

The online version of this article (doi:10.1186/1559-0275-11-43) contains supplementary material, which is available to authorized users.  相似文献   

14.
15.
Fluorescence energy transfer using flow cytometric measurements was utilized to determine the proximity of concanavalin A receptors on the surface of HL-60 promyelocytic leukemia cells before and after induction of differentiation. The HL-60 cells were induced to differentiate into granulocytes using dimethylsulfoxide and into macrophages using 12-O-tetradecanoylphorbol-13-acetate. Concanavalin A was labeled with either fluorescein (donor chromophore) or tetramethylrhodamine (acceptor chromophore), and these species were used to determine lectin proximity. With granulocytic differentiation, the amount of concanavalin A bound remained constant, but a decrease in receptor density was observed. During macrophage differentiation, however, both receptor density and receptor number increased. The increase in concanavalin A binding during differentiation appears to be a result of maturation rather than an initiating event.  相似文献   

16.
17.
Use of a high affinity DNA ligand in flow cytometry.   总被引:3,自引:1,他引:2       下载免费PDF全文
To investigate the feasibility of using oligonucleotides in flow cytometry we describe a model system consisting of human neutrophil elastase (HNE) coated on 3.3 micro beads and a high affinity DNA ligand for HNE isolated by in vitro selection (SELEX). In this system the fluoresceinated DNA ligand was equally effective as an anti- HNE antibody in detecting HNE on beads. The location on and the chemistry of attachment of fluorescein to the DNA ligand is critical for the sensitivity of detection. DNA constructs in which fluorescein was conjugated via an ethylene glycol tether to either the 5'-end or near the 3'-end gave much higher signals than did probes with fluorescein directly conjugated to either end. Second-step staining with strepavidin-conjugated phycoerythrin was accomplished using a biotinylated DNA ligand in the initial staining of HNE beads. These data suggest that instead of, or in addition to, antibodies high affinity oligonucleotide probes can be useful in diagnostic applications based on flow cytometry.  相似文献   

18.
Differential analysis of animal bone marrow by flow cytometry.   总被引:1,自引:0,他引:1  
A simple procedure was developed for rapid analysis of animal bone marrow by flow cytometry using the lipophilic cationic dye 3,3'-dihexyloxacarbocyanine iodide [DiOC6(3)]. The batch process allows differentiation of bone marrow cells into lymphoid, erythroid, and myeloid populations and enables classification of erythroid and myeloid cells into proliferating and maturing subpopulations. From these data, myeloid:erythroid (M:E) ratios and maturation indices for erythroid and myeloid cells (EMI and MMI, respectively) can be derived. This procedure provides the opportunity to analyze bone marrow quantitatively and offers distinct advantages to current manual methods in terms of simplicity, throughput, and reproducibility. The method has been tested successfully using marrow from Wistar rats, B6C3F1 mice, beagle dogs, and cynomolgus monkeys. This technique facilitates the evaluation of bone marrow samples taken from preclinical safety studies or from animal colonies of large size.  相似文献   

19.
We provide a protocol for a high-resolution flow cytometry-based method for quantitative and qualitative analysis of individual nano-sized vesicles released by cells, as developed and previously described by our group. The method involves (i) bright fluorescent labeling of cell-derived vesicles and (ii) flow cytometric analysis of these vesicles using an optimized configuration of the commercially available BD Influx flow cytometer. The method allows the detection and analysis of fluorescent cell-derived vesicles of ~100 nm. Integrated information can be obtained regarding the light scattering, quantity, buoyant density and surface proteins of these nano-sized vesicles. This method can be applied in nanobiology to study basic aspects of cell-derived vesicles. Potential clinical applications include the detailed analysis of vesicle-based biomarkers in body fluids and quality control analysis of (biological) vesicles used as therapeutic agents. Isolation, fluorescent labeling and purification of vesicles can be done within 24 h. Flow cytometer setup, calibration and subsequent data acquisition can be done within 2-4 h by an experienced flow cytometer operator.  相似文献   

20.
Phospholipids are asymmetrically distributed across the membrane of all cells, including red blood cells (RBCs). Phosphatidylserine (PS) is mainly localized in the cytoplasmic membrane leaflet, but during RBC ageing it flip-flops to the external leaflet—a process that is increased in certain pathological conditions (e.g., β-thalassemia). PS externalization in RBCs mediates their phagocytosis by macrophages and removal from the circulation. PS is usually measured by flow cytometry and is reported as the percentage of cells with external PS. In the current study, we developed a novel two-step flow cytometry procedure to quantitatively measure not only the external PS but also the intracellular and shed PS. In this method, PS is first bound to fluorescent annexin V, and then the residual nonbound annexin is quantified by binding to PS exposed on apoptotic cells. Using this method, we measured 1.1 ± 0.2 and 0.12 ± 0.04 μmol inner and external PS, respectively, per 107 normal RBCs. Thalassemic RBCs demonstrated increased PS externalization (1.7-fold) and shedding (11-fold) that was accompanied by lower intracellular PS (31%). These results suggest that quantitative flow cytometry of PS could have a diagnostic value in evaluating the pathology of RBCs in hemolytic anemias associated with increased PS externalization and shortening of the RBC life span.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号