首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
In the present study, we report the first fiber optic glucose sensor utilizing localized surface plasmon resonance of metal nanoparticles. The fiber was bent in the form of a U-shaped probe for point detection and sensitivity enhancement. The probe was prepared by first attaching gold nanoparticles on the optical fiber core and then immobilizing glucose oxidase over it. The sensor operates in the intensity modulation scheme in which the absorbance is measured with respect to the changes in the glucose concentration. The presence of glucose in the vicinity of the sensing region changes the refractive index of the film due to the chemical reactions with glucose oxidase. The absorbance of the metal nanoparticle changes significantly due to local refractive index change. The fiber optic U-shaped probes of different bending radii were fabricated and it has been found that the probe with bending radius around 0.982?mm possesses the maximum sensitivity. The response of the sensor is fast and requires very small volume of sensing sample (??150???l) which makes it more suitable for commercialization and better than present commercial sensors, which require about 1.5?ml of blood for the detection of glucose.  相似文献   

2.
In this paper, a surface plasmon resonance (SPR) based fiber optic ammonia gas sensor has been designed and fabricated using bromocresol purple (BCP) as sensing element. The sensor works under wavelength modulation scheme. The detection of ammonia gas has been carried out at room temperature. Three different kinds of film coating configurations, namely silver + BCP, gold + BCP, and silver + silicon + BCP on the unclad portion of the fiber have been used for studying the role of each layer. Further, to optimize the performance of the sensor, the films of varying thicknesses were coated using thermal evaporation technique. Experiments have been performed for the ammonia concentrations ranging from 0 to 150 ppm around the probe. To record the SPR spectrum, light from a polychromatic source is launched in the fiber and the spectrum is recorded at the other end of the fiber. The spectrum has a peak at lower wavelength while a dip at the higher wavelength. The dip corresponds to SPR while the peak appears to be due to fluorescence properties of the dye. It has been observed that as the ammonia gas comes in contact of the BCP layer, it changes the refractive index of the BCP dye which, in turn, changes the resonance wavelength. Further, the change in refractive index increases as the concentration of ammonia gas increases up to certain concentration of ammonia after that it saturates. Silicon layer has been shown as a protection layer for silver and gold from oxidation and acts as a tuner of wavelength. The proposed ammonia sensor has small response as well as recovery time.  相似文献   

3.
A novel label-free technique for the detection of pathogens based on evanescent wave absorbance (EWA) changes at 280 nm from a U-bent optical fiber sensor is demonstrated. Bending a decladded fiber into a U-shaped structure enhances the penetration depth of evanescent waves and hence sensitivity of the probe. We show that the enhanced EWA response from such U-bent probes, caused by the inherent optical absorbance properties of bacterial cells or biomolecules specifically bound to the sensor surface, can be exploited for the detection of pathogens. A portable optical set-up with a UV light emitting diode, a spectrometer and U-bent fiber optic probe of 200 μm core diameter, 0.75 mm bend radius and effective probe length of 1cm demonstrated an ability to detect less than 1000 cfu/ml.  相似文献   

4.
Cells detection is crucial in microbiological analysis of clinical, food, water or environmental samples. However, currently employed methods are time consuming. Plastic optical fiber (POF) biosensors consist in a viable alternative for rapid and inexpensive scheme for detection. In order to study the sensitivity of tapers for microbiological detection, geometric parameters are studied, such as the taper waist diameter since the formation of taper regions are the key sensing element in this particular type of sensors. In this study, a series of POF taper sensors were prepared using a specially developed tapering machine, and the dispersion of geometric dimensions is evaluated, aiming to achieve the best tapering characteristics which will provide a better sensitivity on the sensor response. The fiber tapers that presented the finest results were those constructed in U-shaped (bended) configurations, with taper waist diameters ranging from 0.40 mm up to 0.50 mm. These fiber tapers were used as the main section of the monitoring device, and when chemically treated as immunosensors for the detection of bacteria, yeast and erythrocytes.  相似文献   

5.
In the present work, the influence of two key design parameters, namely, fiber core diameter and sensing region length on the performance of a fiber optic surface plasmon resonance sensor, was experimentally observed. The sensor was designed with a multimode optical fiber of numerical aperture 0.40 and a thin silver layer of 50 nm thickness. The performance evaluation was carried out in terms of three performance parameters: sensitivity, signal-to-noise ratio and resolution. It was found that performance of the sensor tends to improve if fiber of large core diameter is used. Further, sensing region length should be taken as small as possible to attain highly sensitive and accurate sensing procedure. The experimental results are explained in terms of related physical background and mathematical expressions.  相似文献   

6.
We propose a highly sensitive novel diamond ring fiber (DRF)-based surface plasmon resonance (SPR) sensor for refractive index sensing. Chemically active plasmonic material (gold) layer is coated inside the large cavity of DRF, and the analyte is infiltrated directly through the fiber instead of selective infiltration. The light guiding properties and sensing performances are numerically investigated using the finite element method (FEM). The proposed sensor shows a maximum wavelength and amplitude interrogation sensitivity of 6000 nm/RIU and 508 RIU?1, respectively, over the refractive index range of 1.33–1.39. Additionally, it also shows a sensor resolution of 1.67 × 10?5 and 1.97 × 10?5 RIU by following the wavelength and amplitude interrogation methods, respectively. The proposed diamond ring fiber has been fabricated following the standard stack-and-draw method to show the feasibility of the proposed sensor. Due to fabrication feasibility and promising results, the proposed DRF SPR sensor can be an effective tool in biochemical and biological analyte detection.  相似文献   

7.
Inspired by the classic theory, we suggest that the performance of a D-shaped fiber optical surface plasmon resonance (SPR) sensor can be improved by manipulating the fiber core mode. To demonstrate this, we propose a novel fiber SPR sensor based on a hollow core photonic crystal fiber with liquid mixture filled in the core. The fiber sensor design involves a side-polished fiber with gold film deposited on the polished plane and liquid filling. Numerical simulation results suggest that by tuning the refractive index of the liquid mixture, the predicted sensitivity will be over 6,430 nm/refractive index unit for an aqueous environment, which is competitive for fiber chemical sensing. This optimization method may lead to an ultrahigh sensitivityfiber optical biosensor.  相似文献   

8.
Wang  Jianshuai  Pei  Li  Wu  Liangying  Wang  Ji  Ruan  Zuliang  Zheng  Jingjing 《Plasmonics (Norwell, Mass.)》2020,15(2):327-333

A surface plasmon resonance (SPR) sensor based on a photonic crystal fiber (PCF) is proposed for low refractive index (RI) detection. The core of PCF is formed by two-layer air walls and either layer is composed of six identical sector rings with negative curvature. Plasmonic material gold (Au) is coated on the external cladding surface. Finite element method (FEM) is applied to investigate the performance of the SPR sensor. Results show that the sensor is independent of polarization due to the coincident coupling properties of the two polarized modes. Additionally, in low RI ranging from 1.20 to 1.33, the sensor keeps a high spectral sensitivity with an average value of 7738 nm/RIU. When RI varies from 1.32 to 1.33, the resolution reaches to its maximum of 8.3 × 10−6. The proposed sensor shows much significance in low RI detection, which is promising in real-time measurement for medical, water pollution, and humidity.

  相似文献   

9.
In this article, a D-shaped photonic crystal fiber based surface plasmon resonance sensor is proposed for refractive index sensing. Surface plasmon resonance effect between surface plasmon polariton modes and fiber core modes of the designed D-shaped photonic crystal fiber is used to measure the refractive index of the analyte. By using finite element method, the sensing properties of the proposed sensor are investigated, and a very high average sensitivity of 7700 nm/RIU with the resolution of 1.30 × 10?5 RIU is obtained for the analyte of different refractive indices varies from 1.43 to 1.46. In the proposed sensor, the analyte and coating of gold are placed on the plane surface of the photonic crystal fiber, hence there is no necessity of the filling of voids, thus it is gentle to apply and easy to use.  相似文献   

10.
A novel experimental methodology is presented for fabricating U-shaped optical fiber probes decorated with aggregate-free Au nanoparticles exhibiting sharp localized surface plasmon resonance (LSPR) spectra. The U-type tip is coated with gold nanoparticles (AuNPs) using a simple and time-efficient dip-coating procedure, without initially taking any care to prevent the formation of nanoparticle aggregates in the coated area. In a second step, the coating was irradiated with a few tens of laser pulses of 5-ns duration at 532 nm with intensities in the range of 2–14 MW/cm2, leading to the formation of aggregate-free LSPR optical fiber probes. The process was monitored and controlled in real time through the changes induced into the fiber’s extinction spectra by the laser irradiation, and the coated fibers were characterized by electron microscopy. The proposed methodology resulted into the fabrication of U-type optical fiber probes coated with AuNPs exhibiting a sharp plasmon peak, which is a perquisite for their application as sensing devices.  相似文献   

11.

In this study, we demonstrate the design of a photonic crystal fiber (PCF)-based plasmonic sensor to measure the glucose level of urine. The sensor is designed by placing a small segment of PCF between a lead-in and a lead-out single-mode fiber. We utilize the finite element method to simulate the proposed plasmonic sensor for the measurement of glucose level in urine. To offer external sensing, the cladding layer of the PCF was coated by a thin layer of gold where the gold-coated PCF was immersed in the urine sample. As a result, the urine can easily interact with the plasmonic layer of the sensor. In the outermost laser of the PCF, we considered a perfectly matched layer as a boundary condition. The simulation results confirm excellent wavelength and amplitude sensitivities where the maximum wavelength sensitivity was 2500 nm/RIU and amplitude sensitivity was 152 RIU?1 with a sensing resolution of 4?×?10?6. For optimization of the plasmonic sensor, we varied the physical parameters of the cladding air holes and the thickness of the gold layer during the simulation. We strongly believe that the proposed plasmonic sensor will play a significant role to pave the way for achieving a simple but effective PCF-based glucose sensor.

  相似文献   

12.
Continuous monitoring of intrapulse measurement of blood flow in humans is currently not achievable with clinically available instruments. In this paper, we demonstrate a method of measuring the instantaneous variations in flow during pulsatile blood flow with an optical flow sensor comprising a fiber Bragg grating sensor and illumination from a 565 nm Light‐Emitting‐Diode. The LED illumination heats the blood and fluctuations in temperature, due to variations in flow, are detected by the fiber sensor. A set of experiments at different flow rates (20 to 900 mL/min) are performed in a simulated cardiac circulation setup with pulsatile flow. Data are compared with an in‐line time of flight ultrasound flow sensor. Our results show that the optical and ultrasonic signals correlate with Pearson coefficients ranging from ?0.83 to ?0.98, dependent on the pulsatile frequency. Average flow determined by ultrasound and the optical fiber sensor showed a parabolic relationship with R2 = 0.99. An abrupt step change in flow induced by occlusion and release of the circuit tubing demonstrated that the optical fiber and ultrasound sensor had similar response. The method described is capable of intrapulse blood flow measurement under pulsatile flow conditions, with potential applications in medicine where continuous blood flow sensing is desired.  相似文献   

13.
Moderate paddling, as in long distance kayaking, constitutes an endurance activity, which shares energetic aspects with activities such as long distance running and road cycling. The aim of the present study was to investigate whether in moderate paddling there is a U-shaped relationship between oxygen uptake and stroke rate, and also whether elite kayakers apply a freely chosen stroke rate, which is energetically optimal. Eleven young male elite kayakers performed moderate kayak ergometry at preset target stroke rates of 65, 75, and 90 strokes min-1, and at a freely chosen stroke rate, while physiological responses including oxygen uptake were measured. The results showed that considering average values calculated across all participants, there was an approximately U-shaped relationship between oxygen uptake and target stroke rate with a minimum at 75 strokes min-1. The freely chosen stroke rate was 67.0 ± 6.1 strokes min-1. Thus, the freely chosen stroke rate, for the group in total, appeared to be lower and require higher oxygen uptake as compared to the energetically optimal preset target stroke rate. Eight out of 11 participants had a higher oxygen uptake (5.1% ± 6.7%, p = 0.028, across all participants) at their freely chosen stroke rate than at the preset target stroke rate, which resulted in the lowest oxygen uptake. In conclusion, an approximately U-shaped relationship between oxygen uptake and stroke rate for young elite kayakers during moderate ergometer kayaking was found. Additionally, the freely chosen stroke rate was systematically lower and, consequently, required higher oxygen uptake than the preset stroke rate, which resulted in the lowest oxygen uptake.  相似文献   

14.
A surface plasmon resonance (SPR) sensor based on D-shaped photonic crystal fiber (PCF) coated with indium tin oxide (ITO) film is proposed and numerically investigated. Thanks to the adjustable complex refractive index of ITO, the sensor can be operated in the near-infrared (NIR) region. The wavelength sensitivity, amplitude sensitivity, and phase sensitivity are investigated with different fiber structure parameters. Simulation results show that ~6000 nm/refractive index unit (RIU), ~148/RIU, and ~1.2?×?106 deg/RIU/cm sensitivity can be achieved for wavelength interrogation, amplitude interrogation, and phase interrogation, respectively, when the environment refractive index varies between 1.30 and 1.31. It is noted that the wavelength sensitivity and phase sensitivity are more pronounced with larger refractive index. The proposed SPR sensor can be used in various applications, including medicine, environment, and large-scale targets detection.  相似文献   

15.
We have presented a strain-sensing device in microscale by using surface plasmon polaritons and multimode interference effects. The device is numerically investigated by the finite-difference time-domain method. Optimum depths and length of the structure are designed for sensing a strain. The size of the designed structure is several micrometers and is about a thousandth compared with a fiber Bragg grating strain sensor. The sensitivity of the designed structure is 11.34 pm/μ?? that is about ten times larger than that of a fiber Bragg grating strain sensor. The temperature sensitivity of the designed structure is 34.43 pm/ °C. This temperature sensitivity is three times larger than that of a fiber Bragg grating strain sensor. Therefore, temperature compensation techniques are needed for the structure. The presented structure has a simple design such as a plasmonic waveguide with a trench structure. The simple structural design device has a capability of being used in micro- and nano-electromechanical systems.  相似文献   

16.
The response of optical fiber surface plasmon resonance (SPR) sensor to potential is monitored in real time. The potential-induced reflectance of a gold-coated optical fiber SPR probe is dependent on potential step width and ionic strength. Wider potential step and stronger ionic strength are generally able to enhance the reflectance and accelerate the response time. The specifically adsorptive anion Cl? provides a pronounced effect on a potential-dependent SPR probe. The exclusive contact of the SPR probe with anion Cl? could significantly slow down the optical response. The work offers opportunities for optical fiber SPR probes to characterize the electrochemical application.  相似文献   

17.
Du  Bobo  Yang  Yuan  Zhang  Yang  Yang  Dexing 《Plasmonics (Norwell, Mass.)》2019,14(2):457-463

In this article, a surface plasmon resonance (SPR) biosensor based on D-typed optical fiber coated by Al2O3/Ag/Al2O3 film is investigated numerically. Resonance in near infrared with an optimized architecture is achieved. Refractive index sensitivity of 6558 nm/RIU (refractive index unit) and detection limit of 1.5 × 10−6 RIU, corresponding to 0.4357 nm/μM and detection limit of 23 nM in BSA (bovine serum albumin) concentration sensing, are obtained. The analysis of the performance of the sensor in gaseous sensing indicates that this proposed SPR sensor is much suitable for label-free biosensing in aqueous media.

  相似文献   

18.

We propose a highly sensitive refractive index sensor based on the surface phonon resonance (SPhR) in the mid-IR spectral range. Surface phonon polaritons (SPhPs) are formed on polar dielectrics such as SiC in mid-IR wavelength range and can be excited with the help of a metallic grating at specific wavelength termed as resonance wavelength. The resonance wavelength of SPhP is significantly affected by the refractive index of the analyte medium placed over the grating. This forms the basis of a refractive index sensor. We have numerically evaluated the performance of such an SPhP-based refractive index sensor by using rigorous coupled wave analysis (RCWA) in terms of sensitivity, detection accuracy, and quality factor. The quality factor and detection accuracy of the sensor formed on SiC substrate are found to be 225.1 RIU–1 (inverse of refractive index unit) and 6.75, respectively. We have also extended the study for other polar dielectric substrates cBN and GaN and observed considerable enhancement in the performance of the sensor for GaN. The values of quality factor and detection accuracy could be increased to 361.2 RIU–1 and 10.84, respectively, by using GaN substrate. The proposed sensor finds applications in refractive index sensing of liquids and biomolecules having refractive index in the range 1.33–1.36.

  相似文献   

19.
A temperature sensor based on hollow fiber (HF) filled with graphene-Ag composite nanowire and liquid is presented. The coupling properties and sensing performance are numerically analyzed by finite element method using wavelength and amplitude interrogations. Results show that the sensor exhibiting strong birefringence with x-polarized peak provides much higher sensitivities and better signal-to-noise ratio (SNR) than y-polarized, which is more suitable for temperature detection. The graphene-Ag composite nanowire can not only solve the oxidation problem but also avoid the metal coating. Moreover, it provides better performance than other similar works like Au-Ag nanowire-filled, Au nanowire-filled, and Ag nanowire-filled sensors. Contrary to the blue shift of traditional SPR temperature sensors, the resonance peak shifts to the longer wavelength in our device when temperature increases and the high sensitivity 9.44 nm/ °C is obtained. The influences of nanowire diameter, grapheme-layer thickness on the designed sensor, are also investigated. This work can provide a reference for developing a high sensitivity, real-time, remote sensing, and distributed temperature SPR sensor.  相似文献   

20.
High-density,microsphere-based fiber optic DNA microarrays   总被引:5,自引:0,他引:5  
A high-density fiber optic DNA microarray has been developed consisting of oligonucleotide-functionalized, 3.1-microm-diameter microspheres randomly distributed on the etched face of an imaging fiber bundle. The fiber bundles are comprised of 6000-50000 fused optical fibers and each fiber terminates with an etched well. The microwell array is capable of housing complementary-sized microspheres, each containing thousands of copies of a unique oligonucleotide probe sequence. The array fabrication process results in random microsphere placement. Determining the position of microspheres in the random array requires an optical encoding scheme. This array platform provides many advantages over other array formats. The microsphere-stock suspension concentration added to the etched fiber can be controlled to provide inherent sensor redundancy. Examining identical microspheres has a beneficial effect on the signal-to-noise ratio. As other sequences of interest are discovered, new microsphere sensing elements can be added to existing microsphere pools and new arrays can be fabricated incorporating the new sequences without altering the existing detection capabilities. These microarrays contain the smallest feature sizes (3 microm) of any DNA array, allowing interrogation of extremely small sample volumes. Reducing the feature size results in higher local target molecule concentrations, creating rapid and highly sensitive assays. The microsphere array platform is also flexible in its applications; research has included DNA-protein interaction profiles, microbial strain differentiation, and non-labeled target interrogation with molecular beacons. Fiber optic microsphere-based DNA microarrays have a simple fabrication protocol enabling their expansion into other applications, such as single cell-based assays.  相似文献   