首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive and specific high performance liquid chromatographic method for quantitation of topiramate in human serum was developed using HPLC with fluorescence labeling reagent. Topiramate was extracted from human serum by dichloromethane and derivatized by reaction with 9-fluorenylmethyl chloroformate (FMOC-Cl) in the presence of borate buffer. Analysis was performed on a CN column with sodium phosphate buffer (pH 2.2) containing 1 ml/l triethylamine and methanol (52:48 (v/v)) as mobile phase. Amantadine was used as internal standard. The standard curve was linear over the range 20-5000 ng/ml of topiramate in human serum. The mean intra-day precision was from 10.5% (low concentration) to 1.2% (high concentration) and the within-day precision from 1.5 to 12.5% determined on spiked samples. The accuracy of the method was 96.5-107.5% (intra-day) and 98.4-105% (inter-day). The limit of quantification was 20 ng/ml of serum. This method was used in a bioequivalence study after administration of 2 x 25 mg topiramate in 24 healthy volunteers.  相似文献   

2.
Most of the published methods for analysis of gabapentin, an antiepileptic agent, in human serum are based on the same approach, involving o-phthaldialdehyde derivatization of deproteinized serum samples. The present paper however, describes a new, simple and sensitive high-performance liquid chromatographic method for determination of gabapentin in human serum using liquid-liquid extraction and 9-fluorenylmethyl chloroformate (FMOC-Cl) as pre-column labeling agent. The drug and an internal standard (azithromycin) were extracted from serum by salting-out approach using a mixture of dichloromethane-2 propanol (1:1, v/v) as the extracting solvent. The extracted analytes were subjected to derivatization with FMOC-Cl in the presence of phosphate buffer (pH 7). A mobile phase consisting of methanol-0.05 M sodium phosphate buffer (73/27, v/v; pH of 3.9) containing 1 ml/l triethylamine was eluted and chromatographic separation was performed on a Shimpack CLC-C18 (150 mm x 4.6 mm) column. The standard curve was linear over the range of 0.03-20 microg/ml and limit of quantification was 0.03 microg/ml. The performance of analysis was studied and the validated method showed excellent performance in terms of selectivity, specificity, sensitivity, precision and accuracy. No interferences were found from commonly co-administered antiepileptic agents.  相似文献   

3.
Most of the published methods for analysis of gabapentin, an antiepileptic agent, in human serum require automated o-phthalaldehyde derivatization of the drug and immediate injection of the unstable derivatives formed. A new, very sensitive and simple high-performance liquid chromatographic method for quantitation of the drug in human serum using 4-chloro-7-nitrobenzofurazan (NBD-Cl) as a fluorescent labeling agent is presented. In this method the sensitivity was significantly improved and the limit of quantification of 0.002 microg/ml was obtained using 100 microl serum sample and 10 microl injection. However, the LOQ can be improved by increasing the sampling volume. The procedure involved protein precipitation of serum by acetonitrile followed by derivatization with NBD-Cl. Amlodipine was used as internal standard and chromatographic separation was performed on a Shimpack CLC-C18 (150 mm x 4.6 mm) column. The fluorescence derivative of the drug was monitored at excitation and emission wavelengths of 470 and 537 nm, respectively. A mobile phase consisting of methanol and sodium phosphate buffer (0.05 M; pH 2.5) containing 1 ml/l triethylamine (65:35, v/v) was used. The calibration curve was linear over the concentration range of 0.002-15 microg/ml. No interferences were found from commonly co-administrated antiepileptic drugs. The method was applied in a randomized cross-over bioequivalence study of two different gabapentin preparations in 24 healthy volunteers.  相似文献   

4.
A sensitive and rapid high-performance liquid chromatographic method for the analysis of fluvoxamine, a selective serotonin reuptake inhibitor in human serum, is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. The drug and an internal standard (fluoxetine) were extracted from 0.25 mL of serum using ethyl acetate as extracting solvent and subjected to pre-column derivatization by the reagent. A mobile phase consisting of methanol and sodium phosphate buffer (0.05 M; pH 2.8) containing 1 mL/L triethylamine (72:28 v/v) was used and chromatographic separation was performed on a Shimpack CLC-C18 (150 mm x 4.6mm) column. The fluorescence derivatives of the drugs were monitored at excitation and emission wavelengths of 470 and 537 nm, respectively. The calibration curve was linear over the concentration range of 0.5-240 ng/mL with a limit of quantification (LOQ) of 0.5 ng/mL using 0.25 mL serum sample. The method validation was performed for its selectivity, specificity, sensitivity, precision and accuracy. In this method, which was applied in a randomized cross-over bioequivalence study of two different fluvoxamine preparations in 24 healthy volunteers, the sensitivity and run time of analysis were significantly improved.  相似文献   

5.
A very simple and fast method has been developed and validated for simultaneous determination of the new generation antiepileptic drugs (AEDs) lamotrigine (LTG), oxcarbazepine's (OXC) main active metabolite monohydroxycarbamazepine and felbamate in plasma of patients with epilepsy using high-performance liquid chromatography (HPLC) with spectrophotometric detection. Plasma sample (500 microL) pre-treatment was based on simple deproteinization by acetonitrile. Liquid chromatographic analysis was carried out on a Synergi 4 microm Hydro-RP, 150 mm x 4 mm I.D. column, using a mixture of potassium dihydrogen phosphate buffer (50mM, pH 4.5) and acetonitrile/methanol (3/1) (65:35, v/v) as the mobile phase, at a flow rate of 1.0 mL/min. The UV detector was set at 210 nm. Calibration curves were linear (mean correlation coefficient >0.999 for all the three analytes) over a range of 1-20 mg/mL for lamotrigine, 2-40 microg/mL for monohydroxycarbamazepine and 10-120 microg/mL for felbamate. Both intra and interassay precision and accuracy were lower than 7.5% for all three analytes. Absolute recoveries ranged between 100 and 104%. The present procedure describes for the first time the simultaneous determination of these three new antiepileptic drugs. The simple sample pre-treatment, combined with the fast chromatographic run permit rapid processing of a large series of patient samples.  相似文献   

6.
A high performance liquid chromatographic method for the determination of a biocompatible iron chelator, pyridoxal 2-chlorobenzoyl hydrazone (o-108), in rabbit plasma was developed and validated. The separation was achieved on a C18 column with the mobile phase composed of a mixture of 0.01 M phosphate buffer (pH 6) with the addition of EDTA (2 mM), methanol and acetonitrile (42:24:14; v/v/v). The method was validated with respect to selectivity, linearity (0.8-150 microg/mL), intra- and inter-day variability and stability. This method was successfully applied to the analysis of the samples obtained from a pilot pharmacokinetic experiment, in which the chelator was administered intravenously to rabbits.  相似文献   

7.
A sensitive liquid chromatographic method for the analysis of clarithromycin, a macrolide antibiotic, in human serum using pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) is described. The method involved liquid-liquid extraction of the drug and an internal standard (amantadine) followed by pre-column derivatization of the analytes with FMOC-Cl. A mixture of 0.05 M phosphate buffer containing triethylamine (2 mL L(-1); pH 3.8) and methanol (17:83, v/v) was used as mobile phase and chromatographic separation was achieved on a Shimpack CLC-ODS column. The eluate was monitored by a fluorescence detector with respective excitation and emission wavelengths of 265 and 315 nm. The analytical method was linear over the concentration range of 0.025-10 microg mL(-1) of clarithromycin in human serum with a limit of quantification of 0.025 microg mL(-1). The assay is sensitive enough to measure drug levels obtained in human single dose studies. In the present method, sensitivity and run time of analysis have been improved, and successfully applied in a bioequivalence study of three different clarithromycin preparations in 12 healthy volunteers.  相似文献   

8.
Topiramate has no ultraviolet, visible or fluorescence absorption. Analysis of the drug in human serum has been reported by high performance liquid chromatography (HPLC) with either mass detector or fluorescence detection after precolumn derivatization using 9-fluorenylmethyl chloroformate as fluorescent labeling agent. This study was aimed to validate derivatization and analysis of topiramate in human serum with HPLC using UV detection. The drug was extracted from human serum by liquid-liquid extraction and subjected to derivatization with 9-fluorenylmethyl chloroformate. Analysis was performed on a phenyl column using of spectrophotometer detection operated at wavelength of 264 nm. A mixture of phosphate buffer (0.05M) containing triethylamine (1 ml/l, v/v; pH 2.3) and methanol (28:72, v/v) at a flow rate of 2.5 ml/min was used as mobile phase. No interference was found with endogenous substances. Validity of the method was studied and the method was precise and accurate with a linearity range from 40 ng/ml to 40 microg/ml. The limit of quantification was 40 ng/ml of serum. The correlation coefficient between HPLC methods using fluorescence and UV detections was studied and found to be 0.992.  相似文献   

9.
We present a simple, fast and validated method for the determination of the new generation antiepileptic drug (AED) levetiracetam (LEV) in plasma of patients with epilepsy using high performance liquid chromatography (HPLC) with UV detection. Plasma sample (500 microL) pretreatment was based on simple deproteinization by methanol spiked with the internal standard (I.S.). HPLC analysis was carried out on a Synergi 4-microm Hydro-RP, 150 mm x 4 mm I.D. column. The mobile phase was a mixture of potassium dihydrogen phosphate buffer (50 mM, pH 4.5) and acetonitrile (94:6, v/v) at an isocratic flow rate of 1.5 mL/min. The UV detector was set at 205 nm. Calibration curves were linear (mean correlation coefficient=0.999) over a range of 4-80 microg/mL. The quantitation limit was 2 microg/mL and the absolute recovery was >90% for LEV and the I.S. Both intra and interassay precision and accuracy were lower than 7.5%. The chromatographic run lasted 13 min. The present procedure omitting expensive solid phase or time-consuming liquid-liquid extraction and drying steps is cheaper, faster and simpler than mostly published analytical methods for levetiracetam. Applied to a large population of patients with epilepsy this assay proved very practical in our therapeutic drug monitoring setting (TDM).  相似文献   

10.
An efficient and reliable micellar electrokinetic capillary chromatography (MEKC) method has been developed for the simultaneous determination of isoniazid (ISO) and pyridoxine hydrochloride (PYR) in pharmaceutical formulations. A chemometric two level full factorial design approach was used to search for the optimum conditions of separation. Three parameters were selected for this study: the buffer pH, the buffer concentration and sodium dodecyl sulphate (SDS) concentrations. Resolution, peak symmetry and analysis time were established as response. The two analytes were separated within 6 min with the optimized conditions: 50 mM borate buffer, 25 mM SDS pH 7.8, 35 degrees C, at 50 mbar 4s injection and 30 kV by using a fused silica capillary (72 cm effective length, 50 microm i.d.). The detection wavelength was set to 205 nm. Meloxicam was used as internal standard. The method was validated with respect to stability, linearity range, limit of quantitation and detection, precision, accuracy, specificity and robustness. The detection limits of the method were 1.0 microg mL(-1) for ISO and 0.40 microg mL(-1) for PYR and the method was linear at least in the range of 3.0-100 microg mL(-1) for ISO and 1.0-100 microg mL(-1) for PYR with excellent correlation coefficients (0.9995 for ISO and 0.9998 for PYR). Relative standard deviations (R.S.D.s) of the described method ranged between 0.54 and 2.27% for intra-day precision and between 0.65 and 2.69% for inter-day precision. The developed method was applied to the tablet form of ISO and PYR-containing the pharmaceutical preparations and the data were compared with obtained from the standard addition method. No statistically significant difference was found.  相似文献   

11.
A fast and sensitive high-performance liquid chromatographic method for determination of azithromycin in human serum using fluorescence detection was developed. The drug and an internal standard (clarithromycin) were extracted from serum using n-hexan and subjected to pre-column derivatization with 9-fluorenylmethyl chloroformate as labeling agent. Analysis was performed on a phenyl packing material column with sodium phosphate buffer containing 2 ml/l triethylamine (pH 5.9) and methanol (29:71, v/v) as the mobile phase. The standard curve was linear over the range of 10-500 ng/ml of azithromycin in human serum. The means between-days precision were from 13.3% (for 10 ng/ml) to 2% (500 ng/ml) and the within-day precision from 11.9 to 1.7% determined on spiked samples. The accuracy of the method was 100.7-107.2% (between days) and 100.3-107.8% (within day). The limit of quantification was 10 ng/ml. This method was applied in a bioequivalence study of four different azithromycin preparations in 12 healthy volunteers.  相似文献   

12.
Lamotrigine is a broad-spectrum antiepileptic agent. This study describes a simple and sensitive high-performance liquid chromatographic method for the determination of lamotrigine in 50 microl of plasma. Lamotrigine and the internal standard guanabenz were extracted with 1.2 ml of diethyl ether, after the samples alkalinized with 10 microl of sodium hydroxide solution (1N). Chromatographic separation was achieved on a silica column with the mobile phase of acetonitrile-water containing 0.2% phosphoric acid and 0.3% triethylamine (pH 2.7) (84:16, v/v), at a flow-rate of 1 ml/min. The eluant was detected at 225 nm. The retention time was about 6 min for lamotrigine and 7 min for guanabenz. No endogenous substances and concomitant anticonvulsants were found to interfere. Calibration curves were linear from 0.1 to 5 microg/ml. The relative recovery of lamotrigine averaged about 80%. The limit of quantitation was 0.1 microg/ml. The intra- and inter-day precision (expressed as coefficient of variation, CV) was 8.1%, or less, and the accuracy was within 11.5% deviation of the nominal concentration. The method is suitable in pharmacokinetic investigation and monitoring lamotrigine concentration.  相似文献   

13.
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 °C and the residue was reconstituted with the mobile phase. 5 μL of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm × 150 mm, I.D. 5 μm, Agilent TC-C(18) column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 → 248.2m/z for azatadine, 383.3 → 337.3m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values.  相似文献   

14.
A simple, selective, sensitive and precise high-performance liquid chromatographic plasma assay for the antihypertensive drugs, irbesartan and hydrochlorothiazide is described. Good chromatographic separation was achieved using a Supelcocil C(18) (5 micrometer 15 cmx4.6 mm) column and a mobile phase consisting of 10 mM potassium dihydrogen phosphate:methanol:acetonitrile (5:80:15 v/v/v) (pH:2.5) while at a flow-rate of 1.0 ml min(-1). Irbesartan and hydrochlorothiazide were detected at 275 nm and were eluted 5.8 and 7.8 min, respectively, after injection. No endogenous substances were found to interfere. The method utilizes protein precipitation with acetonitrile as the only sample preparation involved prior to reversed-phase high-performance liquid chromatography. No internal standard was required. Linearity range for irbesartan and hydrochlorothiazide was 10.0-60.0 microgram ml(-1) and 4.0-20.0 microgram ml(-1), respectively. The determination of intra- and inter-day precision (RSD) was less than 2.5 and 3.5%, at all concentration levels, while the inter- and intra-day accuracy (% difference) was less than 4.9-6.2%. This method is being used in a therapeutic drug monitoring service to quantitate these therapeutic agents in patients for pharmacokinetic studies.  相似文献   

15.
A rapid and simple HPLC method with UV detection (288 nm) was developed and validated for quantitation of niflumic acid in human plasma, the active metabolite of talniflumate. After precipitation with 100% methanol containing the internal standard, indomethacin, the analysis of the niflumic acid level in the plasma samples was carried out using a reverse phase C18 CAPCELL PAK (5 microm, 4.6 mm x 250 mm) column. The chromatographic separation was accomplished with an isocratic mobile phase consisting of a mixture of 0.1M sodium acetate in water and acetonitrile (37:63, v/v), adjusted to pH 6.4. This HPLC method was validated by examining its precision and accuracy for inter- and intra-day runs in a linear concentration range of 0.02-5.00 microg/mL. Stability of niflumic acid in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method was successfully applied to the bioequivalence study of talniflunate in healthy volunteers.  相似文献   

16.
Mitoguazone is an antiproliferative agent used in chemotherapy. This study describes a simple and sensitive high-performance liquid chromatographic method for the determination of mitoguazone in 100 microl of plasma. Samples were deproteinized with 100 microl of a solution of internal standard (amiloride, 10 microg/ml) in acetonitrile. An aliquot of the supernatant was injected onto the column. HPLC separation was achieved on a silica column with the mobile phase of methanol-50 mM potassium phosphate buffer (pH 3)-triethylamine (80:20:0.3, v/v), at a flow-rate of 1 ml/min. The eluent was detected at 320 nm. The retention time was about 5.5 min for amiloride and 12 min for mitoguazone. No endogenous substances were found to interfere. Calibration curves were linear from 0.25 to 50 microg/ml. The absolute recoveries of mitoguazone and amiloride were both greater than 84%. The limit of quantitation was 0.25 microg/ml. The intra- and inter-day precision (expressed as RSD) was 5.8%, or less, and the accuracy was 94.7% of the nominal concentration. The method is suitable in pharmacokinetic investigation and monitoring mitoguazone concentration.  相似文献   

17.
A rapid, simple and sensitive high-performance liquid chromatographic (HPLC) assay has been developed for the simultaneous quantification of the HIV-protease inhibitors indinavir, amprenavir, ritonavir, saquinavir and nelfinavir in human plasma. The method involved the solid-phase extraction of the five drugs and the internal standard (I.S., verapamil) from 400 μl of human plasma. The HPLC analysis used a reversed-phase C18 analytical column and a mobile phase consisting of a gradient with 15 mM phosphate buffer (pH 5.75)–acetonitrile and UV monitoring. The method was linear over the therapeutic concentration range for the five HIV-protease inhibitors. The accuracy of the method ranged from 98.2 to 106.7% and the precision values ranged from 1.4 to 8.1% for intra-day precision and from 3.1 to 6.4% for the inter-day values.  相似文献   

18.
A stereoselective liquid chromatography-tandem mass spectrometry assay was developed and validated for quantification of S- and R-metoprolol at concentrations of 0.5-50 microg/L in human plasma. Metoprolol was extracted from plasma by liquid-liquid extraction with ethyl acetate (82% recovery). Chromatographic separation of the enantiomers was achieved on a chiral Chirobiotic T column using an isocratic mobile phase consisting of methanol/acetic acid/ammonia (100/0.15/0.15, v/v/v). An ion trap mass spectrometer with an electrospray interface was used for detection in the positive mode, monitoring the m/z transition 268-->191 for metoprolol. Standard curves for S- and R-metoprolol fitted quadratic functions (r(2)>or=0.9995) over the range 0.5-50 microg/L in plasma, with 0.5 microg/L representing the limit of quantification. In this range, relative standard deviations were <6% for intra-day precision and <10% for inter-day precision. The accuracy was within the range of 92-105%.  相似文献   

19.
A sensitive method for the determination of CQP propionic acid in rat plasma was developed and validated after solid-phase extraction. Chromatographic separation was achieved on a reversed-phase Alltima C18 column with the mobile phase of methanol-0.15% (v/v) phosphoric acid solution (pH 2.5) and step gradient elution resulted in a total run time of about 20min. The analytes were detected by using UV detector at 345nm. A good linear relationship was obtained in the concentration range of 50-12,800ng/mL (r=0.9998). The intra-day RSDs and the inter-day RSDs at the concentration of 200, 800, 6400 and 12,800ng/mL were less than 7.0% and 11.0%, respectively. The intra-day accuracy ranged from 96.3 to 106.5% and the inter-day accuracy ranged from 98.6 to 113.4%, respectively. Average extraction recoveries ranged from 83.6 to 94.3% in plasma at the concentrations of 200, 800, 6400 and 12,800ng/mL. This method was successfully applied to the pharmacokinetic studies on rats.  相似文献   

20.
A liquid chromatographic method is described for the simultaneous determination of cefalexin and trimethoprim in dog plasma. A simple protein precipitation procedure was adopted for the sample preparation with satisfactory extraction recoveries for both analytes. Chromatographic separation of the analytes was achieved on a C(18) column using a mixture of 2 mol/l formate buffer (pH 3.5), methanol and acetonitrile (22:7:7, v/v/v) containing a 0.002 mol/l sodium dodecyl sulfate as mobile phase and detection was performed at 240 nm. The linearity was obtained over the concentration ranges of 1.0-100.0 microg/ml for cefalexin and 0.5-50.0 microg/ml for trimethoprim. For each level of QC samples including the lower limit of quantification, both inter- and intra-day precisions (R.S.D.) were < or =14.0% for cefalexin and < or =11.4% for trimethoprim, and accuracy (RE) was -1.4% for cefalexin and -3.0% for trimethoprim. The present LC method was successfully applied to the pharmacokinetic studies of coformulated cefalexin dispersible tablets after oral administration to beagle dogs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号