 共查询到20条相似文献,搜索用时 15 毫秒
1.
The authors describe a new approach to measuring DNA hybridization based on surface plasmon-coupled emission (SPCE). SPCE is the resonance coupling of excited fluorophores with electron motions in thin metal films, resulting in efficient transfer of energy through the film and radiation into the glass substrate. The authors evaluated the use of SPCE for detection of DNA hybridization. An unlabeled capture biotinylated oligonucleotide was attached near the surface of a thin (50 nm) silver film using streptavidin. The authors then measured the emission intensity of single-stranded Cy5-labeled DNA upon binding to a complementary oligomer attached to a silver film. Hybridization could be detected by an increase in SPCE, which appeared as light radiated into the substrate at a sharply defined angle near 73 degrees from the normal. The largest signals were observed when the excitation angle of incidence equaled the surface plasmon wavelength, but directional emission was also observed without excitation by the surface plasmon evanescent field. The increased intensity is due to proximity to the metal surface, so that hybridization can be detected without a change in the quantum yield of the fluorophore. These results indicate that SPCE can provide highly sensitive real-time measurement of DNA hybridization.  相似文献   

2.
A new method of fluorescence detection that promises to increase sensitivity by 20- to 1000-fold is described. This method will also decrease the contribution of sample autofluorescence to the detected signal. The method depends on the coupling of excited fluorophores with the surface plasmon resonance present in thin metal films, typically silver and gold. The phenomenon of surface plasmon-coupled emission (SPCE) occurs for fluorophores 20-250 nm from the metal surface, allowing detection of fluorophores over substantial distances beyond the metal-sample interface. SPCE depends on interactions of the excited fluorophore with the metal surface. This interaction is independent of the mode of excitation; that is, it does not require evanescent wave or surface-plasmon excitation. In a sense, SPCE is the inverse process of the surface plasmon resonance absorption of thin metal films. Importantly, SPCE occurs over a narrow angular distribution, converting normally isotropic emission into easily collected directional emission. Up to 50% of the emission from unoriented samples can be collected, much larger than typical fluorescence collection efficiencies near 1% or less. SPCE is due only to fluorophores near the metal surface and may be regarded as emission from the induced surface plasmons. Autofluorescence from more distal parts of the sample is decreased due to decreased coupling. SPCE is highly polarized and autofluorescence can be further decreased by collecting only the polarized component or only the light propagating with the appropriate angle. Examples showing how simple optical configurations can be used in diagnostics, sensing, or biotechnology applications are presented. Surface plasmon-coupled emission is likely to find widespread applications throughout the biosciences.  相似文献   

3.
There is a continuing need to increase the brightness and photostability of fluorophores for use in biotechnology, medical diagnostics, and cell imaging. One approach developed during the past decade is to use metallic surfaces and nanostructures. It is now known that excited state fluorophores display interactions with surface plasmons, which can increase the radiative decay rates, modify the spatial distribution of emission, and result in directional emission. One important example is surface plasmon-coupled emission (SPCE). In this phenomenon, the fluorophores at close distances from a thin metal film, typically silver, display emission over a small range of angles into the substrate. A disadvantage of SPCE is that the emission occurs at large angles relative to the surface normal and at angles that are larger than the critical angle for the glass substrate. The large angles make it difficult to collect all of the coupled emission and have prevented the use of SPCE with high-throughput and/or array applications. In the current article, we describe a simple multilayer metal–dielectric structure that allows excitation with light that is perpendicular (normal) to the plane and provides emission within a narrow angular distribution that is normal to the plane. This structure consists of a thin silver film on top of a multilayer dielectric Bragg grating, with no nanoscale features except for the metal or dielectric layer thicknesses. Our structure is designed to support optical Tamm states, which are trapped electromagnetic modes between the metal film and the underlying Bragg grating. We used simulations with the transfer matrix method to understand the optical properties of Tamm states and localization of the modes or electric fields in the structure. Tamm states can exist with zero in-plane wavevector components and can be created without the use of a coupling prism. We show that fluorophores on top of the metal film can interact with the Tamm state under the metal film and display Tamm state-coupled emission (TSCE). In contrast to SPCE, the Tamm states can display either S or P polarization. The TSCE angle is highly sensitive to wavelength, which suggests the use of Tamm structures to provide both directional emission and wavelength dispersion. Metallic structures can modify fluorophore decay rates but also have high losses. Photonic crystals have low losses but may lack the enhanced light-induced fields near metals. The combination of plasmonic and photonic structures offers the opportunity for radiative decay engineering to design new formats for clinical testing and other fluorescence-based applications.  相似文献   

4.
We describe a new method for multi-wavelength immunoassays using surface plasmon-coupled emission (SPCE). This phenomenon is coupling of excited fluorophores with a nearby thin metal film, in our case silver, resulting in strongly directional emission into the underlying glass substrate. The angle at which the radiation propagate through the prism depends on the surface plasmon angle for the relevant wavelength. These angles depend on emission wavelength, allowing measurement of multiple analytes using multiple emission wavelengths. We demonstrated this possibility using antibodies labeled with either Rhodamine Red-X or AlexaFluor 647. These antibodies were directed against an antigen protein bound to the silver surface. The emission from each labeled antibody occurred at a different angle on the glass prism, allowing independent measurement of surface binding of each antibody. This method of SPCE immunoassays can be readily extended to 4 or more wavelengths.  相似文献   

5.
Fluorescence emission is nearly isotropic in space. With typical optical components the collection efficiency is 1% or less. In this preliminary report, we describe a novel approach to transforming the normally isotropic emission into directional emission with a collection efficiency near 50%. This can be accomplished for fluorophores located near a semi-transparent silver film on a glass substrate. The emission couples with the surface plasmon resonance on the silver surface and enters the transparent substrate at a sharply defined angle, the surface plasmon angle for the emission wavelength. We estimate that 40-70% of the total emission enters the substrate at the plasmon angle and can thus be directed towards a detector. Background emission from fluorophores distant from the silver does not couple with the plasmon and is not detected. Different emission wavelengths couple at different angles allowing spectral discrimination without additional optics. Surface plasmon-coupled emission represents a new technology which can be used for high detection efficiency with microfluidic and/or surface-bound assay formats.  相似文献   

6.
We present a new approach for performing fluorescence immunoassay in whole blood using fluorescently labeled anti-rabbit immunoglobulin G (IgG) on a silver surface. This approach, which is based on surface plasmon-coupled emission (SPCE), provides increased sensitivity and substantial background reduction due to exclusive selection of the signal from the fluorophores located near a bioaffinity surface. This article describes the effect of an optically dense sample matrix, namely human whole blood and serum, on the intensity of the SPCE. An antigen (rabbit IgG) was adsorbed to a slide covered with a thin silver metal layer, and the SPCE signal from the fluorophore-labeled anti-rabbit antibody, binding to the immobilized antigen, was detected. The effect of the sample matrix (buffer, human serum, or human whole blood) on the end-point immunoassay SPCE signal was studied. It was demonstrated that the kinetics of binding could be monitored directly in whole blood or serum. The results showed that human serum and human whole blood attenuate the SPCE end-point signal and the immunoassay kinetic signal only approximately two- and threefold, respectively, as compared with buffer, resulting in signals that are easily detectable even in whole blood. The high optical absorption of the hemoglobin can be tolerated because only fluorophores within a couple of hundred nanometers from the metallic film contribute to SPCE. Excited fluorophores outside the 200-nm layer do not contribute to SPCE, and their free space emission is not transmitted through the opaque metallic film into the glass substrate. We believe that SPCE has the potential of becoming a powerful approach for performing immunoassays based on surface-bound analytes or antibodies for many biomarkers directly in dense samples such as whole blood with no need for washing steps.  相似文献   

7.
High-sensitivity detection schemes are of great interest for a number of applications. Unfortunately, such schemes are usually high-cost. We demonstrate a low-cost approach to a high-sensitivity detection scheme based on surface plasmon-coupled emission (SPCE). The SPCE of a monomolecular layer of green fluorescent protein (GFP) is reported here. The protein was electrostatically attached to a thin, SiO(2)-protected silver film deposited on a quartz substrate. The visible, directional emission of GFP was observed at a sharp, well-defined angle of 47.5 degrees from the normal to the coupling prism, and the spectrum corresponded to that of GFP. The SPCE resulting from the reverse Kretschmann configuration showed a 12-fold enhancement over the free space fluorescence. The directional emission was 97% p-polarized. The directionality and high polarization can be coupled with the intrinsic spectral resolution of SPCE to be used in the design miniaturized spectrofluorometers. The observation of SPCE in the visible region of the spectrum from a monolayer of protein opens up new possibilities in protein-based sensing.  相似文献   

8.
We report theoretical predictions and experimental observations of the reduced detection volume with the use of surface-plasmon-coupled emission (SPCE). The effective fluorescence volume (detection volume) in SPCE experiments depends on two near-field factors: the depth of evanescent wave excitation and a distance-dependent coupling of excited fluorophores to the surface plasmons. With direct excitation of the sample (reverse Kretschmann excitation) the detection volume is restricted only by the distance-dependent coupling of the excitation to the surface plasmons. However, with the excitation through the glass prism at surface plasmon resonance angle (Kretschmann configuration), the detection volume is a product of evanescent wave penetration depth and distance-dependent coupling. In addition, the detection volume is further reduced by a metal quenching of excited fluorophores at a close proximity (below 10nm). The height of the detected volume size is 40-70nm, depending on the orientation of the excited dipoles. We show that, by using the Kretschmann configuration in a microscope with a high-numerical-aperture objective (1.45) together with confocal detection, the detection volume can be reduced to 1-2attoL. The strong dependence of the coupling to the surface plasmons on the orientation of excited dipoles can be used to study the small conformational changes of macromolecules.  相似文献   

9.
We used a new method, polarization sensing, to monitor the concentration of the fluorophore rhodamine 800 in an intralipid suspension and in chicken tissue. Rhodamine 800 (Rh800) could be excited at 648 nm using a laser pointer. We developed a simple device for measuring the combined emission from a highly polarized reference film and the unpolarized or orthogonally polarized emission of Rh800 from the scattering intralipid or tissue. The concentration of Rh800 in this medium was revealed by large changes in the polarization (P) with values of P ranging from 0.8 to -0.9. It is possible to vary the sensitive Rh800 concentration range by variation of the detected emission wavelengths, orientation of the excitation polarizer, or fluorophore concentration in the reference film. Polarization sensing of fluorophores in tissue requires only steady-state detection, and can be accomplished with simple and/or portable electronics. Such devices may find use in electronic detection of ingested medicines based on transdermal detection of nontoxic long-wavelength fluorophores.  相似文献   

10.
We report the deposition of highly uniform thin silver films on plastic materials using a wet-chemistry method, suitable for surface plasmon-coupled emission (SPCE). This approach is reproducible for diverse low-cost applications and versatile to generate silver surfaces on various plastics substrates. An oxygen plasma pretreatment of the plastic provides for rapid silvering, leading to a 47-nm-thick continuous film for SPCE applications. The surface smoothness and thickness of the films have been estimated using atomic force microscope. The higher refractive index of polycarbonate, resulted in an SPCE angle of θ F = 470 for Rhodamine B, compared to glass (θ F = 500). The current study presents details on film deposition conditions, appropriate choice of index matching fluids, substrates, and light sources that play a vital role to augment SPCE emission intensity.  相似文献   

11.
Wang L  Gaigalas AK  Reipa V 《BioTechniques》2005,38(1):127-132
The absorption and emission spectra were measured for Cy5 and Alexa 488 fluorophores confined on a glass surface. The data were obtained using fluorometry and spectroscopic ellipsometry. Red shifts of the surface-immobilized fluorophore absorption spectra relative to the fluorophore spectra in aqueous solution were observed using both methods. We interpret these red shifts in terms of a change in the polarizability and polarity of the effective solvent. A formula is given that can be used to estimate expected shifts in absorption and emission maxima for surface-immobilized fluorophores. Spectroscopic ellipsometry measurements provide identification of the fluorophores confined on a glass surface. These results suggest that the design of microarray detection systems should be based on the optical properties of fluorophores attached to the surface and not on the optical properties of fluorophores in solution.  相似文献   

12.
Förster resonant energy transfer (FRET) measurements are widely used to obtain information about molecular interactions and conformations through the dependence of FRET efficiency on the proximity of donor and acceptor fluorophores. Fluorescence lifetime measurements can provide quantitative analysis of FRET efficiency and interacting population fraction. Many FRET experiments exploit the highly specific labelling of genetically expressed fluorescent proteins, applicable in live cells and organisms. Unfortunately, the typical assumption of fast randomization of fluorophore orientations in the analysis of fluorescence lifetime‐based FRET readouts is not valid for fluorescent proteins due to their slow rotational mobility compared to their upper state lifetime. Here, previous analysis of effectively static isotropic distributions of fluorophore dipoles on FRET measurements is incorporated into new software for fitting donor emission decay profiles. Calculated FRET parameters, including molar population fractions, are compared for the analysis of simulated and experimental FRET data under the assumption of static and dynamic fluorophores and the intermediate regimes between fully dynamic and static fluorophores, and mixtures within FRET pairs, is explored. Finally, a method to correct the artefact resulting from fitting the emission from static FRET pairs with isotropic angular distributions to the (incorrect) typically assumed dynamic FRET decay model is presented.   相似文献   

13.
Metallic surfaces can have unusual effects on fluorophores such as increasing or decreasing the rates of radiative decay and the rates of resonance energy transfer (RET). In the present article we describe the effects of metallic silver island films on the emission spectra, lifetimes, and energy transfer for several fluorophores. The fluorophores are not covalently coupled to the silver islands so that there are a range of fluorophore-to-metal distances. We show that proximity of fluorophores to the silver islands results in increased fluorescence intensity, with the largest enhancement for the lowest-quantum-yield fluorophores. Importantly, the metal-induced increases in intensity are accompanied by decreased lifetimes and increased photostability. These effects demonstrate that the silver islands have increased the radiative decay rates of the fluorophore. For solvent-sensitive fluorophores the emission spectra shifted to shorted wavelengths in the presence of the silver islands, which is consistent with a decrease of the apparent lifetime for fluorophores near the metal islands. We also observed an increased intensity and blue spectral shift for the protein human glyoxalase, which displays a low quantum yield for its intrinsic tryptophan emission. In this case the blue shift is thought to be due to increased emission from a buried low-quantum-yield tryptophan residue. Increased intensities were also observed for the intrinsic emission of the nucleic acid bases adenine and thymine and for single-stranded 15-mers poly(T) and poly(C). And finally, we observed increased RET for donors and acceptors in solution and when bound to double-helical DNA. These results demonstrate that metallic particles can be used to modify the emission from intrinsic and extrinsic fluorophores in biochemical systems.  相似文献   

14.
M Irving 《Biophysical journal》1996,70(4):1830-1835
Steady-state fluorescence polarization measurements provide a relatively simple method for investigating the orientation of molecular components in ordered biological systems. However, the observed fluorescence polarization ratios also depend on any mobility of the fluorophores on the time scale of the fluorescence lifetime. Such mobility commonly arises from incomplete immobilization of a fluorescent probe on the macromolecule of interest. A theoretical formalism is presented for the interpretation of steady-state fluorescence polarization ratios in the presence of such rapid fluorophore motion. It is assumed that the fluorophores move freely within a cone between absorption and emission of a photon. Only one new parameter is introduced to describe fluorophore motion, the semi-angle of the cone, and this can be measured in separate experiments on an isotropic system. The fluorophore orientations are assumed to have cylindrical symmetry, but the symmetry axis need not be in the same plane as the center axes of the absorption and emission cones. This geometry applies to muscle and other biological fibers.  相似文献   

15.
The decay of evanescent field intensity beyond a dielectric interface depends upon beam incident angle, enabling the 3-d distribution of fluorophores to be deduced from total internal reflection fluorescence microscopy (TIRFM) images obtained at multiple incident angles. Instrumentation was constructed for computer-automated multiple angle-TIRFM (MA-TIRFM) using a right angle F2 glass prism (n(r) 1.632) to create the dielectric interface. A laser beam (488 nm) was attenuated by an acoustooptic modulator and directed onto a specified spot on the prism surface. Beam incident angle was set using three microstepper motors controlling two rotatable mirrors and a rotatable optical flat. TIRFM images were acquired by a cooled CCD camera in approximately 0.5 degree steps for >15 incident angles starting from the critical angle. For cell studies, cells were grown directly on the glass prisms (without refractive index-matching fluid) and positioned in the optical path. Images of the samples were acquired at multiple angles, and corrected for angle-dependent evanescent field intensity using "reference" images acquired with a fluorophore solution replacing the sample. A theory was developed to compute fluorophore z-distribution by inverse Laplace transform of angle-resolved intensity functions. The theory included analysis of multiple layers of different refractive index for cell studies, and the anisotropic emission from fluorophores near a dielectric interface. Instrument performance was validated by mapping the thickness of a film of dihexyloxacarbocyanine in DMSO/water (n(r) 1.463) between the F2 glass prism and a plano-convex silica lens (458 mm radius, n(r) 1.463); the MA-TIRFM map accurately reproduced the lens spherical surface. MA-TIRFM was used to compare with nanometer z-resolution the geometry of cell-substrate contact for BCECF-labeled 3T3 fibroblasts versus MDCK epithelial cells. These studies establish MA-TIRFM for measurement of submicroscopic distances between fluorescent probes and cell membranes.  相似文献   

16.
荧光共振能量转移(fluorescenceresonanceenergytransfer,FRET),是指能量从一种受激发的荧光基团(fluorophore)以非辐射的方式转移到另一种荧光基团的物理现象.FRET的能量转移效率是两个荧光基团间距离的函数,并对此距离十分敏感,它的有效响应距离一般在1~10nm之间,因而可被用于测定原子间及分子间的距离.这一特点使FRET技术在大分子构象变化、大分子之间相互作用、细胞信号通路等研究中发挥重要作用,成为生物医学研究中的重要方法.但细胞内的生物学过程常常涉及多于两个的大分子间相互作用,二色荧光基团的FRET技术不能满足这种生物学研究的需求.最近,两个研究小组在这方面取得突破,建立了分别基于共聚焦显微镜和流式细胞仪的三色荧光级联FRET技术.这一技术的出现将会极大地促进生物学及相关研究领域的发展.  相似文献   

17.
We demonstrate directional enhanced fluorescence emission from fluorophores located above gold wire gratings. In contrast to previous studies on corrugated films, efficient coupling was recorded for multiple plasmon modes associated with both the active and substrate side of the wires. This difference is likely due to the subtle differences in how light interacts with corrugated films versus metal films with periodic subwavelength slots. For corrugated films, coupling between modes on opposite sides of the grating are out of phase, and therefore plasmon modes on the opposite side of the grating are only weakly excited. For wire gratings, transmission and reflection features have been modeled well with a dynamical diffraction model that includes surface plasmons, which allows for efficient coupling to surface plasmon modes on both sides of the grating. We also compared the two mechanisms for fluorescent enhancement, namely the intense electromagnetic field associated with surface plasmons and excited fluorophores radiating via surface plasmon modes. We found the latter mechanism clearly dominant.  相似文献   

18.
Several studies have shown that hypoxia induces alterations in the lipid membranes of many cell types. The mechanism of these changes might consist in membrane lipid peroxidation. Lipid peroxidation in erythrocytes and spleen is easily detected by measurement of the concentration of fluorescent end-products. Exposure of rats to hypoxia for various time periods induced formation of lipophilic fluorescent products both in erythrocytes and spleen. A new kind of fluorophore was found in chloroform extracts from erythrocytes with excitation maximum at 270 nm and emission maximum at 310 nm. Additionally, two minor fluorophores were observed, emitting at 360 nm and in the region of 415-440 nm. Only one type of fluorophore was detected in spleen, emitting at 445 nm after excitation at 315 nm. The concentration of fluorophores was dependent on the time of hypoxic exposure both in erythrocytes and spleen. In erythrocytes there was a decrease of the predominant fluorophore after 3 hours (54%, P < 0.05) and 21 days (54%, P < 0.05) of hypoxia in relation to normoxic controls, accompanied by changes in spectral patterns of tridimensional fluorescence spectra. There was also a significant increase in the concentration of fluorophore in spleen (to 164%, P < 0.05, after 3 h, and to 240%, P < 0.05, after 21 days). The fluorophores, both in erythrocytes and spleen, were resolved into several distinct fractions with HPLC. The presented results support the hypothesis of hypoxia-induced lipid peroxidation and create a basis for further characterization of the fluorescent products.  相似文献   

19.
We present a novel approach to the enhancement of surface plasmon-coupled emission (SPCE) using surface plasmon excitation in a bimetal (Ag/Au) layer and we validate the enhancement by presenting the results of a model human IgG immunoassay. Theoretical calculations using Fresnel's equations have been carried out to determine the optimum bimetallic composition and the resulting electric field enhancement. Signal enhancement of SPCE was confirmed using a range of bimetallic layers which were deposited on the surface of a high collection efficiency polymer array biochip and subsequently immobilized with Alexa Fluor 647 labeled anti-human IgG. The bimetallic film of Ag/Au (36/10nm) was determined as an optimum substrate for maximum SPCE signal which was a compromise between the long-term stability of the metal layer and the optimized evanescent field enhancement. An enhanced dose-dependent response was also demonstrated which was ~3 times greater than that detected with a pure gold layer. A human IgG immunoassay showed a dose-dependent response yielding a limit of detection of 1pg/ml by the 3σ rule. The improved performance of the bimetal layer compared to that of an assay carried out on a pure gold layer is attributed to the enhanced evanescent field intensity of surface plasmons in the bimetal combination which excites more fluorescence hence producing an enhanced SPCE signal. This result demonstrates the potential of the SPCE-based array biochips as a sensitive and high-throughput analysis platform for biomolecular interactions.  相似文献   

20.
Muscle contraction results from interactions between actin and myosin cross-bridges. Dynamics of this interaction may be quite different in contracting muscle than in vitro because of the molecular crowding. In addition, each cross-bridge of contracting muscle is in a different stage of its mechanochemical cycle, and so temporal measurements are time averages. To avoid complications related to crowding and averaging, it is necessary to follow time behavior of a single cross-bridge in muscle. To be able to do so, it is necessary to collect data from an extremely small volume (an attoliter, 10(-18) liter). We report here on a novel microscopic application of surface plasmon-coupled emission (SPCE), which provides such a volume in a live sample. Muscle is fluorescently labeled and placed on a coverslip coated with a thin layer of noble metal. The laser beam is incident at a surface plasmon resonance (SPR) angle, at which it penetrates the metal layer and illuminates muscle by evanescent wave. The volume from which fluorescence emanates is a product of two near-field factors: the depth of evanescent wave excitation and a distance-dependent coupling of excited fluorophores to the surface plasmons. The fluorescence is quenched at the metal interface (up to approximately 10 nm), which further limits the thickness of the fluorescent volume to approximately 50 nm. The fluorescence is detected through a confocal aperture, which limits the lateral dimensions of the detection volume to approximately 200 nm. The resulting volume is approximately 2 x 10(-18) liter. The method is particularly sensitive to rotational motions because of the strong dependence of the plasmon coupling on the orientation of excited transition dipole. We show that by using a high-numerical-aperture objective (1.65) and high-refractive-index coverslips coated with gold, it is possible to follow rotational motion of 12 actin molecules in muscle with millisecond time resolution.  相似文献   