首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To study impaction versus impingement for the collection and recovery of viable airborne microorganisms, three new bioaerosol samplers have been designed and built. They differ from each other by the medium onto which the bioaerosol particles are collected (glass, agar, and liquid) but have the same inlet and collection geometries and the same sampling flow rate. The bioaerosol concentrations recorded by three different collection techniques have been compared with each other: impaction onto a glass slide, impaction onto an agar medium, and impingement into a liquid. It was found that the particle collection efficiency of agar slide impaction depends on the concentration of agar in the collection medium and on the sampling time, when samples are collected on a nonmoving agar slide. Impingement into a liquid showed anomalous behavior with respect to the sampling flow rate. Optimal sampling conditions in which all three new samplers exhibit the same overall sampling efficiency for nonbiological particles have been established. Inlet and collection efficiencies of about 100% have been achieved for all three devices at a sampling flow rate of 10 liters/min. The new agar slide impactor and the new impinger were then used to study the biological factors affecting the overall sampling efficiency. Laboratory experiments on the total recovery of a typical environmental microorganism, Pseudomonas fluorescens ATCC 13525, showed that both sampling methods, impaction and impingement, provided essentially the same total recovery when relatively nonstressed microorganisms were sampled under optimal sampling conditions. Comparison tests of the newly developed bioaerosol samplers with those commercially available showed that the incorporation of our research findings into the design of the new samplers yields better performance data than data from currently available samplers.  相似文献   

2.
As a bioaerosol sampling standard, Andersen type impactor is widely used since its invention in 1950s, including the investigation of the anthrax attacks in the United States in 2001. However, its related problems such as impaction and desiccation stress as well as particle bounce have not been solved. Here, we improved its biological collection efficiencies by plating a mineral oil layer (100 µL) onto the agar plate. An Andersen six-stage sampler and a BioStage impactor were tested with mineral-oil-spread agar plates in collecting indoor and outdoor bacterial and fungal aerosols. The effects of sampling times (5, 10 and 20 min) were also studied using the BioStage impactor when sampling environmental bioaerosols as well as aerosolized Bacillus subtilis (G+) and Escherichia coli (G-). In addition, particle bounce reduction by mineral-oil-plate was also investigated using an optical particle counter (OPC). Experimental results revealed that use of mineral-oil-spread agar plate can substantially enhance culturable bioaerosol recoveries by Andersen type impactors (p-values<0.05). The recovery enhancement was shown to depend on bioaerosol size, type, sampling time and environment. In general, more enhancements (extra 20%) were observed for last stage of the Andersen six-stage samplers compared to the BioStage impactor for 10 min sampling. When sampling aerosolized B. subtilis, E. coli and environmental aerosols, the enhancement was shown to increase with increasing sampling time, ranging from 50% increase at 5 min to ∼100% at 20 min. OPC results indicated that use of mineral oil can effectively reduce the particle bounce with an average of 66% for 10 min sampling. Our work suggests that enhancements for fungal aerosols were primarily attributed to the reduced impaction stress, while for bacterial aerosols reduced impaction, desiccation and particle bounce played major roles. The developed technology can readily enhance the agar-based techniques including those high volume portable samplers for bioaerosol monitoring.  相似文献   

3.
The fluid dynamic data in Andersen cascade impactor (ACI) are still lacking. Airflows and those affected parameters can be predicted in a preseparator and Andersen cascade impactor (ACI) by computational modeling. This study developed a validated computational fluid dynamic (CFD) model of an ACI and investigated the effects of the preseparator on the CFD parameters. Validation of the computational nozzle velocity for each of the stage 0 to stage 5 of the ACI stages was found to be within a 3.56% error. The flow field indicated that the preseparator accelerated the airflow velocity at the induction tube from 1.13 to 3.71 ± 0.09 m/s and 2.40 to 8.68 ± 0.16 m/s (at 28.3 and 60 L/min of flow rate, respectively). The preseparator produced a nozzle''s wall shear stress ranged from 0.08 to 0.34 Pa on a collection plate, while the ex-preseparator spread wall shear from the plate''s center was in a range of 0.11 to 0.37 Pa (at 28.3 L/min of flow rate). Moreover, the nozzle velocities increased along the distance from the middle of the collection plate to the periphery. The CFD explained the airflow of the preseparator equipped model by accelerating the airflow along the inlet port to maximize the trapping of desirable particles and the generation of a smooth wall shear stress at the collection plate to reduce the particle re-entrainment. While, the ex-preseparator generated an airflow that resulted in a higher wall shear stress occurring on the lower stages.Key words: ACI, flow field, preseparator, wall shear stress  相似文献   

4.
The preseparator of an Andersen impactor with different coating treatments for a range of particle-size distributions was evaluated. Limited theoretical simulations constrained by simplifying assumptions of the airflow fields in the preseparator and upper stages of an 8-stage Andersen impactor were used to reveal low-velocity and high-pressure regions for potential deposition. These regions were then sampled in subsequent particle deposition experiments. Disodium fluorescein aerosols were sampled with different coating treatments of the preseparator floor. Particles collected at impactor stages determined particle size distributions. Stage deposition was compared between different preseparator treatments (buffer and silicon oil). Collection efficiency in the preseparator followed the pattern buffer >silicon oil >untreated. Statistical differences (P>0.05) were noted in collection efficiency of large particles (45 μm-75 μm) in the preseparator. The mass median aerodynamic diameters and geometric standard deviations showed some statistical differences when different preseparator treatments for large particles were used; therefore, preseparator coating was shown to influence performance and thereby estimates of particle size by intertial impaction.  相似文献   

5.
Most studies focusing on detecting microorganisms in air by polymerase chain reaction (PCR) have used a liquid impinger to sample bioaerosols, mainly because a liquid sample is easy to be processed by PCR analysis. Nevertheless, the use of multiple-hole impactors for the analysis of bioaerosols by PCR has not been reported despite its great utility in culture analysis. In this study we have modified the impaction onto an agar surface sampling method to impaction onto a liquid medium using the MAS-100 air sampler (Merck) (single-stage multiple-hole impactor). To evaluate the recovery of airborne microorganisms of both sampling methods, a suspension containing Escherichia coli was artificially aerosolized and bioaerosols were collected onto Tergitol-7 agar and phosphate-buffered saline (PBS) with the MAS-100. A linear regression analysis of the results showed a strong positive correlation between both sampling methods (r = 0.99, slope 0.99, and y intercept 0.07). Afterwards, the method of impingement into a liquid medium was used to study airborne Legionella pneumophila by PCR. A total of 64 samples were taken at a wastewater treatment plant, a chemical plant, and an office building and analyzed by culture and PCR. Results showed that three samples were positive both by PCR and plate culture, and that nine samples negative by plate culture were positive by PCR, proving that L. pneumophila was present in bioaerosols from these three different environments. The results demonstrate the utility of this single-stage multiple-hole impactor for sampling bioaerosols, both by culture and by PCR.  相似文献   

6.
The abbreviated impactor measurement concept is a potential improvement to the labor-intensive full-resolution cascade impactor methodology for inhaler aerosol aerodynamic particle size distribution (APSD) measurement by virtue of being simpler and therefore quicker to execute. At the same time, improved measurement precision should be possible by eliminating stages upon which little or no drug mass is collected. Although several designs of abbreviated impactor systems have been developed in recent years, experimental work is lacking to validate the technique with aerosols produced by currently available inhalers. In part 1 of this two-part article that focuses on aerosols produced by pressurized metered dose inhalers (pMDIs), the evaluation of two abbreviated impactor systems (Copley fast screening Andersen impactor and Trudell fast screening Andersen impactor), based on the full-resolution eight-stage Andersen nonviable cascade impactor (ACI) operating principle, is reported with a formulation producing dry particles. The purpose was to investigate the potential for non-ideal collection behavior associated with particle bounce in relation to internal losses to surfaces from which particles containing active pharmaceutical ingredient are not normally recovered. Both abbreviated impactors were found to be substantially equivalent to the full-resolution ACI in terms of extra-fine and fine particle and coarse mass fractions used as metrics to characterize the APSD of these pMDI-produced aerosols when sampled at 28.3 L/min, provided that precautions are taken to coat collection plates to minimize bounce and entrainment.  相似文献   

7.
Simple Liquid Scrubber for Large-Volume Air Sampling   总被引:3,自引:3,他引:0       下载免费PDF全文
A new large-volume air sampler called the "simple liquid scrubber" is described. It can recover a high percentage of microorganisms from large volumes of air, up to 950 liters/min, and concentrate them into a small volume of liquid at a ratio of about 400,000 to 1. The principle of operation of the scrubber is based on the production of a fine mist in a rapidly moving airstream with ultimate collection of the airborne particles by impingement into the film of liquid formed upon impaction of the mist droplets on the scrubber walls. The scrubber compared favorably with the all-glass impinger (AGI-30) and the slit sampler in tests with the normal flora and with experimental aerosols of Bacillus subtilis var. niger spores.  相似文献   

8.
An efficient method was developed for media separation and cell collection for eukaryotic cells growing in suspension. The method is based on tangential flow microfiltration using an open channel arrangement in a hollow fiber configuration. Best results (highest processing flux rate) for polysulfone hollow fibers were obtained using fibers with internal diameter of 0.75 mm, 0.45 mum pore size, and a cell suspension flow at a shear rate of 14000 s(-1) (0.032 L/min per fiber). A flux rate of 500 L/m(2) h can be obtained by maintaining the surface area/cell ratio at 0.05 m(2)/10 L of cells at a concentration of 2.5 x 10(6) cells/mL. Forty liters of infected insect cells can be concentrated 10 times in 20 min without affecting cell viability. (c) 1995 John Wiley & Sons, Inc.  相似文献   

9.
Fine particle dose (FPD) is a critical quality attribute for orally inhaled products (OIPs). The abbreviated impactor measurement (AIM) concept simplifies its measurement, provided there is a validated understanding of the relationship with the full resolution pharmacopoeial impactor (PIM) data for a given product. This multi-center study compared fine particle dose determined using AIM and PIM for five dry powder inhaler (DPIs) and two pressurized metered-dose inhaler (pMDI) products, one of which included a valved holding chamber (VHC). Reference measurements of FPDPIM were made by each organization using either the full-resolution Andersen 8-stage non-viable impactor (ACI) or Next Generation Impactor (NGI). FPDAIM was determined for the same OIP(s) with their choice of abbreviated impactor (fast screening impactor (FSI), fast screening Andersen (FSA), or reduced NGI (rNGI)). Each organization used its validated assay method(s) for the active pharmaceutical ingredient(s) (APIs) involved. Ten replicate measurements were made by each procedure. The upper size limit for FPDAIM varied from 4.4 to 5.0 μm aerodynamic diameter, depending upon flow rate and AIM apparatus; the corresponding size limit for FPDPIM was fixed at 5 μm in accordance with the European Pharmacopoeia. The 90% confidence interval for the ratio [FPDAIM/FPDPIM], expressed as a percentage, was contained in the predetermined 85–118% acceptance interval for nine of the ten comparisons of FPD. The average value of this ratio was 105% across all OIPs and apparatuses. The findings from this investigation support the equivalence of AIM and PIM for determination of FPD across a wide range of OIP platforms and measurement techniques.  相似文献   

10.
The abbreviated impactor measurement (AIM) concept is a potential solution to the labor-intensive full-resolution cascade impactor (CI) methodology for inhaler aerosol aerodynamic particle size measurement. In this validation study, the effect of increasing the internal dead volume on determined mass fractions relating to aerodynamic particle size was explored with two abbreviated impactors both based on the Andersen nonviable cascade impactor (ACI) operating principle (Copley fast screening Andersen impactor [C-FSA] and Trudell fast screening Andersen impactor [T-FSA]). A pressurized metered dose inhaler-delivered aerosol producing liquid ethanol droplets after propellant evaporation was chosen to characterize these systems. Measures of extrafine, fine, and coarse particle mass fractions from the abbreviated systems were compared with corresponding data obtained by a full-resolution ACI. The use of liquid ethanol-sensitive filter paper provided insight by rendering locations visible where partly evaporated droplets were still present when the “droplet-producing” aerosol was sampled. Extrafine particle fractions based on impactor-sized mass were near equivalent in the range 48.6% to 54%, comparing either abbreviated system with the benchmark ACI-measured data. The fine particle fraction of the impactor-sized mass determined by the T-FSA (94.4 ± 1.7%) was greater than using the C-FSA (90.5 ± 1.4%) and almost identical with the ACI-measured value (95.3 ± 0.4%). The improved agreement between T-FSA and ACI is likely the result of increasing the dead space between the entry to the induction port and the uppermost impaction stage, compared with that for the C-FSA. This dead space is needed to provide comparable conditions for ethanol evaporation in the uppermost parts of these impactors.  相似文献   

11.
Considerable research has been directed toward the development of rapid methods for the identification of air-borne microorganisms. The application of the fluorescent antibody technique (FAT) coupled with the impaction of contaminated air onto glass slides affords a rapid and specific method for the identification of air-borne Pasteurella tularensis. Early experiments presented problems of cross-reaction with organisms other than P. tularensis. These cross-reactions are eliminated by specific adsorption and proper dilution of the conjugate. A series of experiments conducted under rigidly controlled laboratory conditions indicates that fewer than ten viable P. tularensis per slide can be detected by this method. Time of impaction as well as the presence of large concentrations of other microorganisms did not alter this number. Calculations indicate that a concentration as low as one viable organism per 5 liters of air can be detected.  相似文献   

12.
Bacterial air sampling in an animal care laboratory showed that dense aerosols are generated during cage changing and cage cleaning. Reyniers and Andersen sampling showed that the airborne bacteria numbered 50 to 200 colony-forming units (CFU)/ft3 of air. Of the viable particles collected by Andersen samplers, 78.5% were larger than 5.5 μm. A low velocity laminar air flow system composed of high-efficiency particulate air (HEPA) filters and a ceiling distribution system maintained the number of airborne viable particles at low levels, generally less than 2 CFU/ft3. Vertical air flow of 15 ft/min significantly reduced the rate of airborne infection by a strain of Proteus mirabilis. Other factors shown to influence airborne infection included type of cage utilized, the use of bedding, the distance between cages, and the number of animals per cage.  相似文献   

13.
A protocol for bioaerosol collection was developed that provides not only accurate predictions of fungal concentration, but also improves species recovery. Random transfer of a subset of 50 of the 400 impaction points from Andersen single-stage bioaerosol sampling plates results in subcultures that are accurate predictors of fungal concentration (CFU/m3), when compared to duplicate untouched Andersen plates. A linear regression model was developed to estimate CFU/m3 from the colonies counted on the Random-50 plates. The random transfer to five plates (“Random-50” plates), allows large numbers of fungi to be recovered and identified, including slow-growing fungi that otherwise would be masked by fast-growing fungi.  相似文献   

14.
We have developed a new application of the fluorescence photobleaching recovery (FPR) technique for instantaneous measurement of volume flow rates at any axial position along isolated perfused kidney tubules. The method requires fast data acquisition of emitted fluorescence through a photomultiplier (time resolution, 0.5 ms) coupled with differential interference contrast microscopy to measure luminal diameters accurately. While the tubule is perfused in vitro with an impermeant fluorophore (fluorescein sulfonate), a 20-ms bleach pulse reduces the fluorescence in the observation region by 20-25%. Fluorescence recovery is a direct function of perfusate velocity; diffusion plays no significant role in the early phase of recovery. A fluid dynamics approach to data analysis shows that fractional recovery increases linearly with time until t = L/2vm, where L is the length of the observation window and vm is the mean axial velocity. Practically, a linear regression analysis of the early recovery phase allows measurement of vm of up to 0.14 cm/s, i.e., a 40-nl/min flow rate in a 25-microns-diameter tubule. Calibration experiments in small glass tubes perfused at predetermined flow rates demonstrated good accuracy (within 10%) and reproducibility (coefficient of variation, 8.7%). In rat inner medullary collecting ducts microperfused at 4-40 nl/min, the correlation with a standard fluid collection method was excellent (r2 greater than 0.97). The method should also be suitable for the direct measurement of fluid flow rate in kidney tubules or blood vessels microperfused in vivo.  相似文献   

15.
Exposure to airborne microorganisms in indoor environments may result in infectious disease or elicit an allergic or irritant response. Air handling system components contaminated by fungi have been implicated in the dispersal of spores into the indoor environment, thereby serving as a route of exposure to occupants. This study was conducted to provide quantitative data on the dispersal of spores from fungal colonies growing on three types of duct material. Galvanized metal, rigid fibrous glass ductboard, and fiberglass duct liner were soiled and contaminated with a known concentration of Penicillium chrysogenum spores. The duct materials were incubated in humidity chambers to provide a matrix of growing, sporulating fungal colonies at a contamination level of 109 colony forming units (CFU) per duct section, consistent for all materials. For each experiment a contaminated duct section was inserted into the air handling system of an experimental room, and the air handling system was operated for three 5-minute cycles with an air flow of 4.2 m3 min–1. The duct air velocity was approximately 2.8 m sec–1. The airborne concentration of culturable P. chrysogenum spores (CFU m–3), total P. chrysogenum spores (spores m–3), and total P. chrysogenum-sized particles (particles m–3) were measured in the room using Andersen single-stage impactor samplers, Burkard slide impactor samplers, and an aerodynamic particle sizer, respectively. The highest airborne concentrations (104 CFU m–3; 105 spores m–3; 104 particles m–3) were measured during the first operating cycle of the air handling system for all duct materials with decreasing airborne concentrations measured during the second and third cycles. There was no significant difference in spore dispersal from the three contaminated duct materials. These data demonstrate the potential exposure for building occupants to high concentrations of spores dispersed from fungal colonies on air handling system duct materials during normal operation of the system.  相似文献   

16.
The MIC of 1,10-phenanthroline for 35 Pseudomonas aeruginosa strains was 128 micrograms/ml, whereas 32 micrograms or less per ml inhibited all other microorganisms tested. On the basis of these results, a selective agar for P. aeruginosa which contained 15 g of Trypticase soy broth (BBL Microbiology Systems), 15 g of agar, and 0.1 g of phenanthroline per liter was formulated. Forty-four P. aeruginosa strains yielded a mean efficiency of plating on this medium of 79% of the counts obtained on Trypticase soy agar, which was significantly higher than that obtained with pseudomonas isolation agar or Pseudosel agar. Pseudomonas cepacia, Pseudomonas fluorescens, Pseudomonas putida, Pseudomonas stutzeri, representatives of 13 other genera (including gram-negative rods, gram-positive rods, and cocci), and a yeast were not recovered within 48 h at 35 degrees C when approximately 10(7) CFU were plated on this medium. Only small colonies from one strain each of P. fluorescens and P. putida could be seen at 3 and 7 days, respectively, and they had an efficiency of plating of only less than 0.001%. When 10(7) CFU of either of these strains was plated with 10(2) CFU of P. aeruginosa, it did not interfere with the quantitative recovery of P. aeruginosa.  相似文献   

17.
The MIC of 1,10-phenanthroline for 35 Pseudomonas aeruginosa strains was 128 micrograms/ml, whereas 32 micrograms or less per ml inhibited all other microorganisms tested. On the basis of these results, a selective agar for P. aeruginosa which contained 15 g of Trypticase soy broth (BBL Microbiology Systems), 15 g of agar, and 0.1 g of phenanthroline per liter was formulated. Forty-four P. aeruginosa strains yielded a mean efficiency of plating on this medium of 79% of the counts obtained on Trypticase soy agar, which was significantly higher than that obtained with pseudomonas isolation agar or Pseudosel agar. Pseudomonas cepacia, Pseudomonas fluorescens, Pseudomonas putida, Pseudomonas stutzeri, representatives of 13 other genera (including gram-negative rods, gram-positive rods, and cocci), and a yeast were not recovered within 48 h at 35 degrees C when approximately 10(7) CFU were plated on this medium. Only small colonies from one strain each of P. fluorescens and P. putida could be seen at 3 and 7 days, respectively, and they had an efficiency of plating of only less than 0.001%. When 10(7) CFU of either of these strains was plated with 10(2) CFU of P. aeruginosa, it did not interfere with the quantitative recovery of P. aeruginosa.  相似文献   

18.
The purpose of this study was to resolve an anomalously high measure of extra-fine particle fraction (EPF) determined by the abbreviated cascade impactor possibly relevant for human respiratory tract (AIM-HRT) in the experiment described in Part 1 of this two-part series, in which the relative precision of abbreviated impactors was evaluated in comparison with a full resolution Andersen eight-stage cascade impactor (ACI). Evidence that the surface coating used to mitigate particle bounce was laterally displaced by the flow emerging from the jets of the lower stage was apparent upon microscopic examination of the associated collection plate of the AIM-HRT impactor whose cut point size defines EPF. A filter soaked in surfactant was floated on top of this collection plate, and further measurements were made using the same pressurized metered-dose inhaler-based formulation and following the same procedure as in Part 1. Measures of EPF, fine particle, and coarse particle fractions were comparable with those obtained with the ACI, indicating that the cause of the bias had been identified and removed. When working with abbreviated impactors, this precaution is advised whenever there is evidence that surface coating displacement has occurred, a task that can be readily accomplished by microscopic inspection of all collection plates after allowing the impactor to sample ambient air for a few minutes.  相似文献   

19.
Bioaerosol concentrations inside one naturally ventilated and one mechanically ventilated swine finishing barn were assessed by sampling air using membrane filtration and impaction (six-stage Andersen sampler), and assayed by culture method. The barns, located on the same commercial farm in northeast Kansas, did not show any significant difference (p > 0.05) in concentrations of total and respirable airborne microorganisms. The overall mean total concentrations inside the two barns were 6.6 × 104 colony forming units (CFU)/m3 (SD = 3.8 × 104 CFU/m3) as measured by filtration and 8.6 × 104 CFU/m3 (SD = 5.1 × 104 CFU/m3) by impaction. The overall mean respirable concentrations were 9.0 × 103 CFU/m3 (SD = 4.1 × 103 CFU/m3) measured by filtration and 2.8 × 104 CFU/m3 (SD = 2.2 × 104 CFU/m3) by impaction. Total and respirable CFU concentrations measured by impaction were significantly (p < 0.05) higher than that by filtration. The persistent strains of microorganisms were various species of the following genera: Staphylococcus, Pseudomonas, Bacillus, Listeria, Enterococcus, Nocardia, Lactobacillus, and Penicillium. It appears that filtration sampling can be used for a qualitative survey of bioaerosols in swine barns while the Andersen sampler is suitable for both quantitative and qualitative assessments. Received: 2 April 2001 / Accepted: 13 June 2001  相似文献   

20.
The effectiveness of installed air contamination control systems for removal of airborne microorganisms was determined. Seven separate systems were challenged with aerosolized T1 bacteriophage. Air samples were collected with Andersen samplers containing agar plates that had been swabbed with susceptible Escherichia coli. The advantages of using bacteriophage for testing air-handling systems are discussed. The air systems employed both filtration and ultraviolet irradiation and air-flow rates varied from 600 to 18,000 ft3/min. Reduction rates of airborne bacteriophage passing through the various air systems ranged from 99.8 to 99.99%.  相似文献   