首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Motion of the wrist bones is complicated and difficult to measure. Noninvasive measurement of carpal kinematics using medical images has become popular This technique is difficult and most investigators employ custom software. The objective of this paper is to describe a validated methodology for measuring carpal kinematics from computed tomography (CT) scans using commercial software. Four cadaveric wrists were CT imaged in neutral, full flexion, and full extension. A registration block was attached to the distal radius and used to align the data sets from each position. From the CT data, triangulated surface models of the radius, lunate, and capitate bones were generated using commercial software. The surface models from each wrist position were read into engineering design software that was used to calculate the centroid (position) and principal mass moments of inertia (orientation) of (1) the capitate and lunate relative to the fixed radius and (2) the capitate relative to the lunate. These data were used to calculate the helical axis kinematics for the motions from neutral to extension and neutral to flexion. The kinematics were plotted in three dimensions using a data visualization software package. The accuracy of the method was quantified in a separate set of experiments in which an isolated capitate bone was subjected to two different known rotation/translation motions for ten trials each. For comparison to in vivo techniques, the error in distal radius surface matching was determined using the block technique as a gold standard. The motion that the lunate and capitate underwent was half that of the overall wrist flexion-extension range of motion. Individually, the capitate relative to the lunate and the lunate relative to the radius generally flexed or extended about 30 deg, while the entire wrist (capitate relative to radius) typically flexed or extended about 60 deg. Helical axis translations were small, ranging from 0.6 mm to 1.8 mm across all motions. The accuracy of the method was found to be within 1.4 mm and 0.5 deg (95% confidence intervals). The mean error in distal radius surface matching was 2.4 mm and 1.2 deg compared to the use of a registration block. Carpal kinematics measured using the described methodology were accurate, reproducible, and similar to findings of previous investigators. The use of commercially available software should broaden the access of researchers interested in measuring carpal kinematics using medical imaging.  相似文献   

2.
An in-vivo approach to the measurement of three-dimensional motion patterns of carpal bones in the wrist may have future diagnostic applications, particularly for ligament injuries of the wrist. Static methods to measure carpal kinematics in-vivo only provide an approximation of the true kinematics of the carpal bones. This study is aimed at finding the difference between dynamically and statically acquired carpal kinematics.For eight healthy subjects, static and a dynamic measurements of the carpal kinematics were performed for a flexion–extension and a radio–ulnar deviation movement. Dynamic scans were acquired by using a four-dimensional X-ray imaging system during an imposed cyclic motion. To assess static kinematics of the wrists, three-dimensional rotational X-ray scans were acquired during step-wise flexion–extension and radio–ulnar deviation. The helical axis rotations and the rotation components. i.e. flexion–extension, radio–ulnar deviation and pro–supination were the primary parameters. Linear mixed model statistical analysis was used to determine the significance of the difference between the dynamically and statically acquired rotations of the carpal bones.Small and in most cases negligible differences were observed between the dynamic motion and the step-wise static motion of the carpal bones. The conclusion is that in the case of individuals without any pathology of the wrist, carpal kinematics can be studied either dynamically or statically. Further research is required to investigate the dynamic in-vivo carpal kinematics in patients with dynamic wrist problems.  相似文献   

3.
The eight small and complexly shaped carpal bones of the wrist articulate in six degrees of freedom with each other and to some extent with the radius and the metacarpals. With the increasing number and sophistication of studies of the carpus, a standardized definition for a coordinate system for each the carpal bones would aid in the reporting and comparison of findings. This paper presents a method for defining and constructing a coordinate system specific to each of the eight carpal bones based upon the inertial properties of the bone, derived from surface models constructed from three-dimensional (3-D) medical image volumes. Surface models from both wrists of 5 male and 5 female subjects were generated from CT image volumes in two neutral wrist positions (functional and clinical). An automated algorithm found the principal inertial axes and oriented them according to preset conditions in 85% of the bones, the remaining bones were corrected manually. Six of the eight carpal bones were significantly more extended in the functional neutral position than in the clinical neutral position. Gender had no significant effect on carpal bone posture in either wrist position. Correlations between the 3-D carpal posture and the commonly used 2-D clinical radiographic carpal angles are established. 3-D coordinate systems defined by the anatomy of the carpal bone, such as the ones presented here, are necessary to completely describe 3-D changes in the posture of the carpal bones.  相似文献   

4.
The use of registration techniques to determine motion transformations noninvasively has become more widespread with the increased availability of the necessary software. In this study, three surface registration techniques were used to generate carpal bone kinematic results from a single cadaveric wrist specimen. Surface contours were extracted from specimen computed tomography volume images of the forearm, carpal, and metacarpal bones in four arbitrary positions. Kinematic results from each of three registration techniques were compared with results derived from multiple spherical markers fixed to the specimen. Kinematic accuracy was found to depend on the registration method and bone size and shape. In general, rotation errors of the capitate and scaphoid were less than 0.5 deg for all three techniques. Rotation errors for the other bones were generally less than 2 deg, although error for the trapezoid was greater than 2 deg in one technique. Translation errors of the bones were generally less than 1 mm, although errors of the trapezoid and trapezium were greater than 1 mm for two techniques. Tradeoffs existed in each registration method between image processing time and overall kinematic accuracy. Markerless bone registration (MBR) can provide accurate measurements of carpal kinematics and can be used to study the noninvasive, three-dimensional in vivo kinematics of the wrist and other skeletal joints.  相似文献   

5.
The measurement of relative motion between two moving bones is commonly accomplished for in vitro studies by attaching to each bone a series of either passive or active markers in a fixed orientation to create a rigid body (RB). This work determined the accuracy of motion between two RBs using an Optotrak optical motion capture system with active infrared LEDs. The stationary noise in the system was quantified by recording the apparent change in position with the RBs stationary and found to be 0.04 degrees and 0.03 mm. Incremental 10 degrees rotations and 10-mm translations were made using a more precise tool than the Optotrak. Increasing camera distance decreased the precision or increased the range of values observed for a set motion and increased the error in rotation or bias between the measured and actual rotation. The relative positions of the RBs with respect to the camera-viewing plane had a minimal effect on the kinematics and, therefore, for a given distance in the volume less than or close to the precalibrated camera distance, any motion was similarly reliable. For a typical operating set-up, a 10 degrees rotation showed a bias of 0.05 degrees and a 95% repeatability limit of 0.67 degrees. A 10-mm translation showed a bias of 0.03 mm and a 95% repeatability limit of 0.29 mm. To achieve a high level of accuracy it is important to keep the distance between the cameras and the markers near the distance the cameras are focused to during calibration.  相似文献   

6.
Measurements of in-vitro carpal kinematics of the wrist provide valuable biomechanical data. Tendon loading is often applied during cadaver experiments to simulate natural stabilizing joint compression in the wrist joint. The purpose of this study was to investigate the effect of tendon loading on carpal kinematics in-vitro.A cyclic movement was imposed on 7 cadaveric forearms while the carpal kinematics were acquired by a 4-dimensional rotational X-ray imaging system. The extensor- and flexor tendons were loaded with constant force springs of 50 N, respectively. The measurements were repeated without a load on the tendons. The effect of loading on the kinematics was tested statistically by using a linear mixed model.During flexion and extension, the proximal carpal bones were more extended with tendon loading. The lunate was on the average 2.0° (p=0.012) more extended. With tendon loading the distal carpal bones were more ulnary deviated at each angle of wrist motion. The capitate was on the average 2.4° (p=0.004) more ulnary deviated.During radioulnar deviation, the proximal carpal bones were more radially deviated with the lunate 0.7° more into radial deviation with tendon loading (p<0.001). Conversely, the bones of distal row were more flexed and supinated with the capitate 1.5° more into flexion (p=0.025) and 1.0° more into supination (p=0.011).In conclusion, the application of a constant load onto the flexor and extensor tendons in cadaver experiments has a small but statistically significant effect on the carpal kinematics during flexion–extension and radioulnar deviation.  相似文献   

7.
A digital database of wrist bone anatomy and carpal kinematics   总被引:2,自引:0,他引:2  
The skeletal wrist consists of eight small, intricately shaped carpal bones. The motion of these bones is complex, occurs in three dimensions, and remains incompletely defined. Our previous efforts have been focused on determining the in vivo three-dimensional (3-D) kinematics of the normal and abnormal carpus. In so doing we have developed an extensive database of carpal bone anatomy and kinematics from a large number of healthy subjects. The purpose of this paper is to describe that database and to make it available to other researchers. CT volume images of both wrists from 30 healthy volunteers (15 males and 15 females) were acquired in multiple wrist positions throughout the normal range of wrist motion. The outer cortical surfaces of the carpal bones, radius and ulna, and proximal metacarpals were segmented and the 3-D motion of each bone was calculated for each wrist position. The database was constructed to include high-resolution surface models, measures of bone volume and shape, and the 3-D kinematics of each segmented bone. The database does not include soft tissues of the wrist. While there are numerous digital anatomical databases, this one is unique in that it includes a large number of subjects and it contains in vivo kinematic data as well as the bony anatomy.  相似文献   

8.
A novel computational model of the wrist that predicts carpal bone motion was developed in order to investigate the complex kinematics of the human wrist.This rigid body spring model (RBSM) of the wrist was built using surface models of the eight carpal bones, the bases of the five metacarpal bones, and the distal parts of the ulna and radius, all obtained from computed tomography (CT) scans of a cadaver upper limb. Elastic contact conditions between the rigid bodies modeled the influence of the cartilage layers, and ligamentous structures were constructed using nonlinear, tension-only spring elements. Motion of the wrist was simulated by applying forces to the tendons of the five main wrist muscles modeled.Three wrist motions were simulated: extension, ulnar deviation and radial deviation. The model was tested and tuned by comparing the simulated displacement and orientation of the carpal bones with previously obtained CT-scans of the same cadaver arm in deviated (45°ulnar and 15°radial), and extended (57°) wrist positions. Simulation results for the scaphoid, lunate, capitate, hamate and triquetrum are presented here and provide credible prediction of carpal bone movement. These are the first reported results of such a model. They indicate promise that this model will assist in future wrist kinematics investigations. However, further optimization and validation are required to define and guarantee the validity of results.  相似文献   

9.
Present data on carpal kinematics and carpal ligament behaviour are limited to flexion and deviation movements of the hand. These motions do not represent all the wrist-joint motions which are important for the activities of daily living. The goal of this project was to obtain insight into carpal kinematics and carpal ligament behaviour during motions of the hand covering the full range of motion of the wrist joint.

The carpals and the ligaments of four wrist-joint specimens were provided with radiopaque markers. These joints were subjected to Röntgenstereophotogrammetric experimentation in a large number of hand positions to determine carpal positions and ligament lengths. The movements of the carpal bones were described by means of finite helical axes (FHA).

It was found that the movements of the carpals in the distal row closely resemble those of the hand. Conversely, the motions of the carpals of the proximal row appeared not to be directly proportional to the hand motions and exhibited clear out-of-plane movements. Furthermore, it could be shown that movements of the hand into the ulnodorsal quadrant of the full range of hand motion corresponds to larger helical rotations and translations for most of the carpals than when the hand was moved into any other quadrant. The maximal ligament length changes determined did not exceed the length changes reported for pure flexion and pure deviation movements of the hand.  相似文献   


10.
In this paper, an alternative method is presented to convert computed tomography (CT)-scans into 3D biomodels. The CT-data of an equine spine was converted into TIF format to work with it in a 2D CAD program. Then the bony structure has been marked manually with closed splines and saved as IGS files for the next procedure with 3D CAD software to create virtual biomodels of every single bone. Therefore, the different layers of the CT-scans were positioned in correct distance and then a closed surface was created to cover all spline-curves. Finally, the cover was filled up with material to create a solid part.This method can be recommended as an alternative way, if CAD software is available only. Especially, if it is necessary to add extra artificial spline-curves to split two or more bones which were unnaturally grown together, working with 3D CAD software is the right solution.  相似文献   

11.
The shape and size of insertion sites associated to the relevant carpal ligaments are given in terms of outlines and surface areas. The sites are reconstructed as areas on the contours of the carpal bones with the use of three-dimensional reconstruction of serially sectioned wrists. The computer-models of the wrist-joint show accurately the sofar uncharted three-dimensional orientations of the insertions. The documentation of the surface areas is a first approach to the quantitative analysis of the bone-ligament complex of the wrist-joint. This is needed in future studies about the role of the ligament behavior in wrist-joint motion.  相似文献   

12.
It has previously been shown that the articulation of the scaphotrapezio-trapezoidal (STT) joint can be modeled such that the trapezoid and trapezium are tightly linked and move together on a single path relative to the scaphoid during all directions of wrist motion. The simplicity of such a model is fascinating, but it leaves unanswered why two distinct carpal bones would have a mutually articulating surface if there were no motion between them, and how such a simplistic model of STT joint motion translates into the more complex global carpal motion. We performed an in vivo analysis of the trapezoids and trapeziums of 10 subjects (20 wrists) using a markerless bone registration technique. In particular, we analyzed the centroid spacing, centroid displacements, kinematics, and postures of the trapezoid and trapezium relative to the scaphoid. We found that, on a gross level, the in vivo STT motion was consistent with that reported in vitro. In addition, we found that the magnitude of trapezoid and trapezium motion was dependent upon the direction of wrist motion. However, we also found that when small rotations and displacements are considered there were small but statistically significant relative motions between the trapezoid and trapezium (0.4 mm in maximum flexion, 0.3 mm in radial deviation and at least 10 degrees in flexion extension and ulnar deviation) as well as slight off-path rotations. The results of this study indicate that the STT joint should be considered a mobile joint with motions more complex than previously appreciated.  相似文献   

13.
The foot consists of many small bones with complicated joints that guide and limit motion. A variety of invasive and noninvasive means [mechanical, X-ray stereophotogrammetry, electromagnetic sensors, retro-reflective motion analysis, computer tomography (CT), and magnetic resonance imaging (MRI)] have been used to quantify foot bone motion. In the current study we used a foot plate with an electromagnetic sensor to determine an individual subject's foot end range of motion (ROM) from maximum plantar flexion, internal rotation, and inversion to maximum plantar flexion, inversion, and internal rotation to maximum dorsiflexion, eversion, and external rotation. We then used a custom built MRI-compatible device to hold each subject's foot during scanning in eight unique positions determined from the end ROM data. The scan data were processed using software that allowed the bones to be segmented with the foot in the neutral position and the bones in the other seven positions to be registered to their base positions with minimal user intervention. Bone to bone motion was quantified using finite helical axes (FHA). FHA for the talocrural, talocalcaneal, and talonavicular joints compared well to published studies, which used a variety of technologies and input motions. This study describes a method for quantifying foot bone motion from maximum plantar flexion, inversion, and internal rotation to maximum dorsiflexion, eversion, and external rotation with relatively little user processing time.  相似文献   

14.
Understanding the kinematics of the carpus is essential to the understanding and treatment of wrist pathologies. However, many of the previous techniques presented are limited by non-functional motion or the interpolation of points from static images at different postures. We present a method that has the capability of replicating the kinematics of the wrist during activities of daily living using a unique mechanical testing system. To quantify the kinematics of the carpal bones, we used bone pin-mounted markers and optical motion capture methods. In this paper, we present a hammering motion as an example of an activity of daily living. However, the method can be applied to a wide variety of movements. Our method showed good accuracy (1.0–2.6°) of in vivo movement reproduction in our ex vivo model. Most carpal motion during wrist flexion–extension occurs at the radiocarpal level while in ulnar deviation the motion is more equally shared between radiocarpal and midcarpal joints, and in radial deviation the motion happens mainly at the midcarpal joint. For all rotations, there was more rotation of the midcarpal row relative to the lunate than relative to the scaphoid or triquetrum. For the functional motion studied (hammering), there was more midcarpal motion in wrist extension compared to pure wrist extension while radioulnar deviation patterns were similar to those observed in pure wrist radioulnar deviation. Finally, it was found that for the amplitudes studied the amount of carpal rotations was proportional to global wrist rotations.  相似文献   

15.
In this study, a novel rapid prototyping technology was used to fabricate scaphoid and lunate bone prostheses, two carpal bones that are prone to avascular necrosis. Carpal prostheses were fabricated with an Envisiontec Perfactory® SXGA stereolithography system using Envisiontec eShell 200 photocurable polymer. Fabrication was guided using 3-D models, which were generated using Mimics software (Materialise NV, Leuven, Belgium) from patient computer tomography data. The prostheses were fabricated in a layer-by-layer manner; ∼ 50-μm thick layers were observed in the prostheses. Hardness and Young's modulus values of polymerized eShell 200 material were 93.8 ± 7.25 MPa and 3050 ± 90 MPa, respectively. The minimum compressive force required for fracture was 1360 N for the scaphoid prosthesis and 1248 N for the lunate prosthesis. Polymerized Envisiontec eShell material exhibited high human neonatal epidermal keratinocyte cell viability rate in an MTT assay. The results of this study indicate that small bone prostheses fabricated by stereolithography using eShell 200 polymer may have suitable geometry, mechanical properties, and cytocompatibility properties for in vivo use.  相似文献   

16.
One of the main events in the history of our species has been our expansion out of Africa. A clear signature of this expansion has been found on global patterns of neutral genetic variation, whereby a serial founder effect accompanied the colonization of new regions, in turn creating a wilhin-pupulation decrease in neutral genetic diversity with increasing distance from Africa. This same distinctive pattern has also been described for cranial and dental morphological variation in human populations distributed across the globe. Here, we used a data set of postcranial linear measurements for 30 globally distributed human populations, and a climatic data set of minimum annual temperature, maximum annual temperature, and precipitation in order to separate for the first time the relative effect of neutral demographic processes and climatic selection on four long (limb) bones (femur, tibia, radius, and humerus) versus the pelvic bones of the human appendicular skeleton. We implemented a stepwise regression procedure in which phenotypic variance is assumed to be affected by the iterative founder events that accompanied human expansion from Africa, as well as by climate. This model included, as independent factors, geographic distance from central Africa, the three climatic variables, and all possible interactions between the three climatic variables. We excluded all nonsignificant factors by backward stepwise elimination with the aim of identifying the minimal model significantly explaining variation in the phenotypic data. Our results indicate a sharp difference in the way the pelvis and the limb bones reflect the neutral signature of the out-of-Africa expansion. Consistent with previous analyses of the cranium and dentition, pelvic shape variation shows a significant within-population decrease with increasing distance from Africa. However, no such pattern could be found in the long bones. Rather, in the case of both the tibia and the femur, a significant relationship between population-level variance and minimum temperature was demonstrated. Hence, in the case of these limb bones, it is probable that the effects of climatic selection have obliterated the demographic signature of human dispersal from Africa. Our finding mat pelvic variation exhibits the neutral effects of demographic history suggests that consideration of this skeletal element might be used to shed light on factors of human population history, just as the cranium has done.  相似文献   

17.
Anatomical differences among squirrels are usually most evident in the comparison of flying squirrels and nongliding squirrels. This is true of wrist anatomy, probably reflecting the specializations of flying squirrels for the extension of the wing tip and control of it during gliding. In the proximal row of carpals of most squirrels, the pisiform articulates only with the triquetrum, but in flying squirrels there is also a prominent articulation between the pisiform and the scapholunate, providing a more stable base for the styliform cartilage, which supports the wing tip. In the proximal wrist joint, between these carpals and the radius and ulna, differences in curvature of articular surfaces and in the location of ligaments also correlate with differences in degree and kind of movement occurring at this joint, principally reflecting the extreme dorsal flexion and radial deviation of the wrist in flying squirrels when gliding. The distal wrist joint, between the proximal and distal rows of carpals, also shows most variation among flying squirrels, principally in the articulations of the centrale with the other carpal bones, probably causing the distal row of carpal bones to function more like a single unit in some animals. There is little variation in wrist musculature, suggesting only minor evolutionary modification since the tribal radiation of squirrels, probably in the early Oligocene. Variation in the carpal bones, particularly the articulation of the pisiform with the triquetrum and the scapholunate, suggests a different suprageneric grouping of flying squirrels than previously proposed by McKenna (1962) and Mein (1970). J. Morphol. 246:85-102, 2000. Published 2000 Wiley-Liss, Inc.  相似文献   

18.
The scaphoid is the most frequently fractured of the carpal bones [Taleisnik, J., The Wrist, Churchill Livingstone, New York (1985)]. This project was undertaken to qualitatively evaluate the strain in the scaphoid during wrist motion using a newly developed strain gage method. Strain gage resettes were mounted within the scaphoid and the range of motion of the hand was monitored using a custom designed electrogoniometer and data acquisition system. Ten specimens were utilized for this study. Results indicated that supination/pronation (S/P) of the forearm did not affect the strain in the scaphoid. A map of the strain in the waist of the scaphoid, as a function of flexion/extension (F/E) and radial/ulnar deviation (R/U), was generated. The contour plot of scaphoid strain vs range of motion (ROM) shows a valley where strains are low. Minimum scaphoid strain was found near neutral F/E and 15° of ulnar deviation.  相似文献   

19.
To examine whether the bone mineral density (BMD) decreases uniformly with aging in any spongy bones, the authors investigated age-related changes of BMD in the calcaneus, talus, and scaphoid bone. After the ordinary dissection by medical students was finished, calcanei, tali, and scaphoid bones were resected from the subjects, and BMDs were measured by dual-energy X-ray absorptiometry. Their BMDs seemed to decrease gradually with aging in the calcanei, tali, and scaphoid bones. It was found that there were statistically significant relationships between age and BMD in the men’s and women’s scaphoid bones, women’s tali, and women’s calcanei, but not in the men’s tali and calcanei. It should be noted that there were significant relationships between age and BMD in both men’s and women’s scaphoid bones. In regard to relationship in BMD between the bones of the upper and lower limbs in individuals, it was found that the relationship between the calcaneus and talus was higher than that between the calcaneus and scaphoid bone. This suggests that there is a higher relationship in BMD between the two tarsal bones compared with that between the tarsal and carpal bones.  相似文献   

20.
The mammalian Carpus is a complex of several small bones with multiple interactions during walking. Therefore, it is highly probable that different mammalian families developed distinctive constellations in their Carpi, which could be useful for biometric identification of phylogenetic groupings. The carpal bones of nineteen extant ruminant species (nine bovid, nine cervid, and one moschid) have been investigated to search for biometric traits which are diagnostic for the three families. Additionally, we searched for diverging functional adaptations in the carpal constellations. Therefore, measurements have been taken from the five main carpals, which are carrying the body weight. As a sesamoid bone, Os carpi accessorium was excluded. After transformation of the data into their natural logarithms, multivariate methods of factor analyses and discriminant analyses were performed for each bone. Bivariate plots of the factor scores allowed a clear separation of bovids and cervids. The only one species of the Moschidae (Moschus moschiferus) lies closer to the cervids than to the bovids. The grouping is due to phylogenetic relationships and not due to functional differences in the groups or differing habitat preferences. Generally, the carpals of cervids are more slender and higher in contrast to the bulky and flat carpals in bovids. This approach could be used to assign isolated carpal bones found in fossil sites to their ruminant family.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号