1.
Sentinel lymph node biopsy might replace complete axillary dissection for staging of the axilla in clinically N0 breast cancer patients and represent a significant advantage as a minimally invasive procedure, considering that about 70% of patients are found to be free from metastatic disease, yet axillary node dissection can lead to significant morbidity. In our Institute, Radioguided Occult Lesion Localization is the standard method to locate non-palpable breast lesions and the gamma probes is very effective in assisting intra-operative localization and removal, as in sentinel node biopsy. The rapid spread of sentinel lymph node biopsy has led to its use in clinical settings previously considered contraindications to sentinel lymph node biopsy.In this contest, we evaluated in a large group of patients possible factors affecting sentinel node detection and the reliability of sentinel lymph node biopsy carried out after large excisional breast biopsy. Our data confirm that a previous breast surgery does not prohibit efficient sentinel lymph node localization and sentinel lymph node biopsy can correctly stage the axialla in these patients.  相似文献   

2.
The sentinel lymph node (SLN) is considered to be the first axillary node that contains malignant cells in metastatic breast tumors, and its positivity is currently used in clinical practice as an indication for axillary lymph node dissection. Therefore, accurate evaluation of the SLN for the presence of breast metastatic cells is essential. The main aim of our study is to characterize the genomic changes present in the SLN metastatic samples with the ultimate goal of improving the predictive value of SLN evaluation. Twenty paired samples of SLN metastases and their corresponding primary breast tumors (PBT) were investigated for DNA copy number changes using comparative genomic hybridization (CGH). Non-random DNA copy number changes were observed in all the lesions analyzed, with gains being more common than losses. In 75% of the cases there was at least one change common to both PBT and SLN. The most frequent changes detected in both lesions were gains of 1pter-->p32, 16, 17, 19, and 20 and losses of 6q13-->q23 and 13q13-->q32. In the PBT group, alterations on chromosomes 1, 16, and 20 were the most frequent, whereas chromosomes 1, 6, and 19 were the ones with the highest number of changes in the SLN metastatic group. A positive correlation was found between the DNA copy number changes per chromosome in each of the groups. Our findings indicate the presence of significant DNA copy number changes in the SLN metastatic lesions that could be used in the future as additional markers to improve the predictive value of SLN biopsy procedure.  相似文献   

3.
OBJECTIVE: Sentinel lymph node (SLN) biopsy is a new component of the surgical treatment of breast cancer that accurately predicts axillary status. In this study the authors evaluated the accuracy of intraoperative imprint cytology (IC) in comparison with definitive histologic evaluation of SLN in breast cancer patients. METHODS: A total 413 women with breast carcinoma and clinically negative axillary nodes underwent breast surgery and SLN biopsy. Mapping of SLN involved injection of (99m)Technecium labelled human albumin nanocolloid particles and Patent Blue dye. At the Department of Pathology, SLNs were bisected along its major axis. Both halves were imprinted 2-4 times on the slides and immediate staining with Hemacolor (Merck Germany) was performed for intraoperative examination. Imprint node negative women underwent no further surgery, while node positive women proceeded to full axillary clearance. Histological analysis of the SLN involved serial sectioning of the whole node with H&E and immunostaining for cytokeratin. RESULTS: Definitive histology revealed metastases (pN+) in 159/413 patients (38.5%): 69 (16.7%) macro metastases, 57 (13.8%) micro metastases, and 33 (8%) women with only isolated IHC positive cells or positive cell groups smaller than 0.2 mm (pNO sn+). The other 254 women had negative SLN biopsy. Imprint cytology detected 54/69 macro metastases, and 4/57 micro metastases. In the group with negative SLN (254), 2 cases were 'false positives'. CONCLUSIONS: Imprint of SLN biopsy can identify a negative axilla with high accuracy (specificity 99.2%). Overall sensitivity is only 36.5%, but macrometastases are detected in 77% which is important for performing ALDN in one session with operation of primary tumour.  相似文献   

4.
目的:探讨胃癌术中前哨淋巴结(sentinel lymph node,SLN)定位检测的可行性及其临床意义。方法:使用亚甲蓝对40例胃癌患者行前哨淋巴结术中标识活检,随后行D2或D2以上手术。结果:40例胃癌患者中,38例找到前哨淋巴结,检出率为38/40(95%),有32例存在SLN转移,8例SLN为唯一转移部位,且均为T1、T2期。由SLN的病理学状态来预测胃周围淋巴结转移情况的敏感性为32/34(94.12%),特异性为4/4(100%),假阴性率为2/34(5.88%),准确率为34/38(89.47%),其中假阴性的2例,肿瘤都处于T4期。结论:胃癌SLN定位及活检技术能较准确反映早期胃癌的淋巴结转移状况,但对进展期胃癌而言假阴性率较高,对胃癌整个区域淋巴结状态预测的可靠性和可行性尚需进一步验证。  相似文献   

5.
目的:探讨胃癌术中前哨淋巴结(sentinel lymph node,SLN)定位检测的可行性及其临床意义。方法:44t用亚甲蓝对40例胃癌患者行前哨淋巴结术中标识活检,随后行D2或D2以上手术。结果:40例胃癌患者中,38例找到前哨淋巴结,检出率为38/40(95%),有32例存在SLN转移,8例SLN为唯一转移部位,且均为T1、T2期。由SLN的病理学状态来预测胃周围淋巴结转移情况的敏感性为32/34(94.12%),特异性为4/4(100%),假阴性率为2/34(5.88%),准确率为34/38(89.47%),其中假阴性的2例,肿瘤都处于T4期。结论:胃癌SLN定位及活检技术能较准确反映早期胃癌的淋巴结转移状况,但对进展期胃癌而言假阴性率较高,对胃癌整个区域淋巴结状态预测的可靠性和可行性尚需进一步验证。  相似文献   

6.
目的:探讨吲哚菁绿(indocyanine green,ICG)联合亚甲蓝在乳腺癌前哨淋巴结活检(sentinel lymph node biopsy,SLNB)中的临床应用价值。方法:共入组39例乳腺癌患者,在光学分子影像手术导航系统(surgical navigation system,SNS)的引导下,使用ICG联合亚甲蓝实施SLNB。快速冰冻病理证实前哨淋巴结(sentinel lymph node,SLN)转移者,即刻行腋窝淋巴结清扫(axillary lymph node dissection,ALND);SLN阴性者免于ALND。结果:联合法实施SLNB检出率95%,成功检出SLN125个,平均检出3.2个SLN,准确率95.0%,灵敏度100%,假阴性率0%;蓝染法检出率87.2%,成功检出SLN71个,平均检出1.8个SLN,准确率89.7%,灵敏度93.7%,假阴性率为6.3%;统计结果采用x2检验,检验结果具有统计学意义。结论:ICG联合亚甲蓝实施乳腺癌SLNB成功率高,假阴性率低,临床效果不亚于亚甲蓝,是实施SLNB的新方法。  相似文献   

7.
A. Schiettecatte, C. Bourgain, C. Breucq, N. Buls, V. De Wilde and J. de Mey
Initial axillary staging of breast cancer using ultrasound‐guided fine needle aspiration: a liquid‐based cytology study Objective: To evaluate the preoperative detection of axillary metastasis combining ultrasound (US)‐guided fine needle aspiration cytology (FNAC) and liquid‐based cytology (Surepath®) to reduce sentinel node procedures. Methods: In total, 148 patients with clinically negative lymph nodes and no preoperative therapy were included. All patients underwent preoperative ultrasound of the axilla with FNAC if suspicious lymph nodes were found. Complete axillary lymph node dissection was performed at primary surgery when FNAC was positive. All other patients underwent a sentinel node procedure. Results: US‐guided FNAC of the axilla revealed metastasis in 34 (23.0%) of the 148 patients. These 34 patients were 53.1% of all patients (n = 64) with proven axillary lymph node involvement. In 66 patients (44.6%), both ultrasound and histopathology were negative. Overall sensitivity of US‐guided FNAC was 50.0%, specificity 100%, positive predictive value 100% and negative predictive value 70.2%. In T1 tumours, all patients referred for sentinel node procedure were node‐negative. The correlation between malignant FNAC and histopathology was 100%. US‐guided liquid‐based FNAC in patients with no clinically positive lymph nodes reduced the necessity for a sentinel node procedure by 23.0%. Conclusions: We advocate that US‐guided fine needle aspiration (FNA) combined with liquid‐based cytology of axillary lymph nodes should be included in the preoperative staging of breast cancer.  相似文献   

8.
摘要 目的:探究对初诊腋窝淋巴结阳性乳腺癌行新辅助化疗患者开展腋窝前哨淋巴结活检的临床意义。方法:选择2017年1月至2020年10月于我院接受改良根治术或保乳术治疗的100例初诊腋窝淋巴结阳性乳腺癌患者,将其中50例病理检测II B、III期行4~8个疗程新辅助化疗后实施前哨淋巴结活检患者设为研究组,将50例I、II A期直接行前哨淋巴结活检患者设为对照组,对比两组患者前哨淋巴结检出率、准确率、假阴性率和灵敏度,同时就患者病理特征与前哨淋巴结检出率的相关性开展分析。结果:(1)比较显示研究组患者与对照组患者在前哨淋巴结检出数、前哨淋巴结检出率以及前哨淋巴结假阴性率方面组间差异不大(P>0.05);(2)病理学特征分析显示肿瘤直径以及临床N分期同新辅助化疗后患者前哨淋巴结检出阳性率密切相关(P<0.05)。结论:对初诊腋窝淋巴结阳性行新辅助化疗乳腺癌患者实施前哨淋巴结活检具有较显示的临床意义,能够较好的预测患者腋窝淋巴结状况,同时化疗前肿瘤直径、临床N分期是影响前哨淋巴结检出率的重要影响因素。  相似文献   

9.
ObjectivesUntil now, the effectiveness of sentinel lymph-node biopsy (SLNB) has only been demonstrated for the detection of axillary lymphatic involvement in early breast cancer (cT1N0). The purpose of this study was to evaluate whether the detection of an extra-axillary internal mammary sentinel lymph node (SLN), using peritumoral injection of radiolabelled nanocolloids (NC), can lead to a modification in management for these patients.Materials and methodsA total of 538 consecutives SLNB was analysed from a cohort of 529 patients. Peri- and infratumoral injections of radiolabelled NC were made under ultrasound control.ResultsA SLN was identified on 524 occasions, 147 (28.1%) of which were located in the internal mammary chain (IMC). In 10 cases, the SLN in the IMC was not associated with an axillary SLN. One hundred and thirty-five surgical biopsies of the IMC SLN were performed without significant morbidity. Sixteen patients demonstrated local involvement of an IMC SLN, which on seven occasions was isolated to this region. For six of these patients, the finding of SLN involvement led to a recommendation for adjuvant chemotherapy. For 308 patients, for lack of IMC involvement, the adjuvant IMC radiotherapy could have been avoided (i.e.: 95% of the theoretical indications for adjuvant radiotherapy).ConclusionsPeritumoral injection of radiolabelled NC, associated with a systematic IMC SLN biopsy, enabled the rationalisation of management in patients with stage cT1 breast cancer and did not affect the usual performance of the technique nor led to a significant increase in morbidity. The long-term survival and morbidity outcomes of these therapeutic modifications, particularly with regards to radiotherapy, will need to be demonstrated.  相似文献   

10.
ABSTRACT: BACKGROUND: It is not clear if sentinel lymph node (SLN) mapping can improve outcomes in patients with colorectal cancers. The purpose of this study was to determine the prognostic values of ex vivo sentinel lymph node (SLN) mapping and immunohistochemical (IHC) detection of SLN micrometastasis in colorectal cancers. METHODS: Colorectal cancer specimens were obtained during radical resections and the SLN was identified by injecting a 1% isosulfan blue solution submucosally and circumferentially around the tumor within 30 min after surgery. The first node to stain blue was defined as the SLN. SLNs negative by hematoxylin and eosin (HE) staining were further examined for micrometastasis using cytokeratin IHC. RESULTS: A total of 54 patients between 25 and 82 years of age were enrolled, including 32 males and 22 females. More than 70% of patients were T3 or above, about 86% of patients were stage II or III, and approximately 90% of patients had lesions grade II or above. Sentinel lymph nodes were detected in all 54 patients. There were 32 patients in whom no lymph node micrometastasis were detected by HE staining and 22 patients with positive lymph nodes micrometastasis detected by HE staining in non-SLNs. In contrast only 7 SLNs stained positive with HE. Using HE examination as the standard, the sensitivity, non-detection rate, and accuracy rate of SLN micrometastasis detection were 31.8% (7/22), 68.2% (15/22), and 72.2%, respectively. Micrometastasis were identified by ICH in 4 of the 32 patients with HE-negative stained lymph nodes, resulting in an upstaging rate 12.5% (4/32). The 4 patients who were upstaged consisted of 2 stage I patients and 2 stage II patients who were upstaged to stage III. Those without lymph node metastasis by HE staining who were upstaged by IHC detection of micrometastasis had a significantly poorer disease-free survival (p = 0.001) and overall survival (p = 0.004). CONCLUSION: Ex vivo localization and immunohistochemical detection of sentinel lymph node micrometastasis in patients with colorectal cancer can upgrade tumor staging, and may become a factor affecting prognosis and guiding treatment.  相似文献   

11.
To determine the performance of intraoperative one-step nucleic acid amplification (OSNA) assay in detecting sentinel lymph node metastases compared to postoperative histology taking into account breast cancer molecular classification and to evaluate whether the level of cytokeratin 19 mRNA copy number may be useful in predicting the likelihood of a positive axillary lymph node dissection. OSNA assay was performed in a prospective series of 903 consecutive sentinel lymph nodes from 709 breast cancer patients using 2 alternate slices of each sentinel lymph node. The remaining 2 slices were investigated by histology. Cytokeratin 19 mRNA copy number, which distinguishes negative cases (<250 copies), micrometastases (+, ≥250≤5000 copies) and macrometastases (++, >5000 copies), was compared to axillary lymph node dissection status and to the biological tumor profile. Concordance between OSNA and histopathology was 95%, specificity 95% and sensitivity 93%. Multiple Corresponce Analysis and logistic regression evidenced that positive axillary lymph node dissection was significantly associated with a higher cytokeratin 19 mRNA copy number (>5000; p<0.0001), HER2 subtype (p = 0.007) and lymphovascular invasion (p<0.0001). Conversely, breast cancer patients with cytokeratin 19 mRNA copy number <2000 mostly presented a luminal subtype and a negative axillary lymph node dissection. We confirmed that OSNA assay can provide standardized and reproducible results and that it represents a fast and quantitative tool for intraoperative evaluation of sentinel lymph node. Omission of axillary lymph node dissection could be proposed in patients presenting a sentinel lymph node with a cytokeratin 19 mRNA copy number <2000 and a Luminal tumor phenotype.  相似文献   

12.
目的:分析乳腺导管原位癌的前哨淋巴结临床及病理特征,探讨乳腺导管原位癌患者实施前哨淋巴结活检的指征。方法:回顾性分析2002年10月到2010年11月期间诊断为乳腺导管原位癌并行前哨淋巴结活检的46例患者的的前哨淋巴结状态及其与其他临床及病理特征的关系。结果:患者的年龄、肿瘤大小、检出SLN数、肿瘤分级、切缘状态、DCIS类型、是否伴随坏死均无显著统计学意义(P0.05)。可能与乳腺导管原位癌患者前哨淋巴结阳性的几个因素为:年龄41岁-69岁、肿瘤大小1.1 cm-5.0cm、切缘状态未知、肿瘤坏死伴随或未知、肿瘤分级Ⅰ级以上或未知。结论:以下几个因素可能对预测DCIS患者可能出现SLN阳性提供帮助,临床在遇到出现这些因素的DCIS患者需慎重考虑其治疗策略,这些因素包括:年龄41岁-69岁、肿瘤大小1.1cm-5.0 cm、切缘状态未知、肿瘤坏死伴随或未知、肿瘤分级Ⅰ级以上或未知。  相似文献   

13.
BACKGROUND: Preoperative lymphoscintigraphy is one of the three methods of evaluating sentinel nodes in patients with breast cancer; however, it has been reported to have a high false negative rate. CASE PRESENTATIONS: We report here two cases where the preoperative lymphoscintigraphy was found to be fallacious. A 44-year-old female with T2N0 breast cancer underwent preoperative lymphoscintigraphy with Tc99 sulfur colloid which failed to show any uptake in axilla or internal mammary chain. Intraoperative scintigraphy with blue dye and hand held gamma probe identified sentinel lymph node in axilla. Another patient with T2N0 lesion underwent preoperative lymphoscintigraphy which showed a sentinel lymph node in axilla and another in supraclevicular fossa. Intraoperative scintigraphy failed to show supraclevicular node however axillary node was correctly identified. CONCLUSION: These two cases further strengthen the need to carry out triple test in identification of sentinel lymph node in patients with breast cancer. It also demonstrates the fallacies of preoperative lymphoscintigraphy.  相似文献   

14.
BACKGROUND: Lymph node metastasis status is a prognostic factor for further lymph node involvement and for patient survival in breast cancer patients. Frozen section analysis of lymph nodes is a reliable method for detection of macro-metastases. However, this method is far less effective in detecting micro-metastases, requesting improved diagnostic procedures. METHODS: We investigated expression and truncation of ezrin in (i) sentinel lymph node metastases, (ii) unaffected axillary lymph nodes, (iii) primary breast tumors, and (iv) healthy glandular breast tissues using 2D gel electrophoresis, SDS-PAGE, and mass spectrometry in addition to Western blotting. RESULTS: Full-length ezrin (E1; amino acids 1–586) is present in all four investigated tissues. Two truncated ezrin forms, one missing about the first hundred amino acids (E2a) and the other lacking about 150 C-terminal amino acids (E2b) were detectable in primary tumor tissues and in sentinel lymph node metastases but not in glandular tissues. Strikingly, an ezrin truncation (E3) which consists approximately of amino acids 238–586 was found strongly expressed in all sentinel lymph node metastases. Moreover, an N-terminal ezrin fragment (E4) that consists approximately of amino acids 1–273 was identified in sentinel lymph node metastases as well. CONCLUSIONS: We show for the first time the existence of tissue-dependent specific ezrin truncations. The distinguished strong Western blot staining of ezrin E3 in sentinel lymph node metastases underlines its capability to substantiate the occurrence of lymph node (micro)metastases in breast cancer patients.  相似文献   

15.
The indication of neoadjuvant chemotherapy has been recently extended; it is now applied not only in locally advanced breast cancer but in primarily resecable tumours as well, in order to promote breast conservation. Based on recent clinical results, the reconsideration of traditional lymph node dissection in axillary staging is timely in patients receiving neoadjuvant chemotherapy. Precise axillary staging needs surgical removal of lymph nodes. Based on prospective randomised trials, sentinel lymph node biopsy appears to be appropriate for axillary staging even in tumours requiring neoadjuvant treatment. The extended indication of sentinel lymph node biopsy raises several questions and problems. In the present paper the authors review the results and possible limitations of sentinel lymph node biopsy in relation to neoadjuvant chemotherapy.  相似文献   

16.
Axillary clearance provides important prognostic information but is associated with significant morbidity. Sentinel node biopsy can provide staging .141 patients with node negative early breast cancers-tumour size less than 1.5 cm measured clinically or by imaging had guided axillary sampling (sentinel lymph node biopsy in combination with axillary sampling). Four node axillary sampling improved the detection rate of axillary node metastases by 13.6% as compared to blue dye sentinel node biopsy alone. Positive sampled nodes strongly indicated the likelihood of further metastatic being revealed by axillary dissection (67%). Negative sampled nodes in combination with a positive sentinel node biopsy were associated with a much lower rate of further nodal involvement in the axillary clearance (8%).  相似文献   

17.

Background

One of the most exciting and talked about new surgical techniques in breast cancer surgery is the sentinel lymph node biopsy. It is an alternative procedure to standard axillary lymph node dissection, which makes possible less invasive surgery and side effects for patients with early breast cancer that wouldn't benefit further from axillary lymph node clearance. Sentinel lymph node biopsy helps to accurately evaluate the status of the axilla and the extent of disease, but also determines appropriate adjuvant treatment and long-term follow-up. However, like all surgical procedures, the sentinel lymph node biopsy is not appropriate for each and every patient.

Methods

In this article we review the absolute and relative contraindications of the procedure in respect to clinically positive axilla, neoadjuvant therapy, tumor size, multicentric and multifocal disease, in situ carcinoma, pregnancy, age, body-mass index, allergies to dye and/or radio colloid and prior breast and/or axillary surgery.

Results

Certain conditions involving host factors and tumor biologic characteristics may have a negative impact on the success rate and accuracy of the procedure. The overall fraction of patients unsuitable or with multiple risk factors that may compromise the success of the sentinel lymph node biopsy, is very small. Nevertheless, these patients need to be successfully identified, appropriately advised and cautioned, and so do the surgeons that perform the procedure.

Conclusion

When performed by an experienced multi-disciplinary team, the SLNB is a highly effective and accurate alternative to standard level I and II axillary clearance in the vast majority of patients with early breast cancer.  相似文献   

18.
The sentinel lymph node (SLN) concept has become a standard of care for patients with breast cancer and melanoma, yet its clinical application to other cancer types has been somewhat limited. This is mainly due to the reduced accuracy of conventional SLN mapping techniques (using blue dye and/or radiocolloids as lymphatic tracers) in cancer types where lymphatic drainage is more complex, and SLNs are within close proximity to other nodes or the tumour site. In recent years, many novel techniques for SLN mapping have been developed including fluorescence, x-ray, and magnetic resonant detection. Whilst each technique has its own advantages/disadvantages, the role of targeted contrast agents (for enhanced retention in the SLN, or for immunostaging) is increasing, and may represent the new standard for mapping the SLN in many solid organ tumours. This review article discusses current limitations of conventional techniques, limiting factors of nanoparticulate based contrast agents, and efforts to circumvent these limitations with modern tracer architecture.  相似文献   

19.
For patients with invasive breast cancer, if the results of an axillary sentinel node biopsy are determined to be positive after permanent pathologic examination, the current recommendation is to perform a complete axillary node dissection. Subsequent axillary surgery may compromise the blood supply to an immediate autologous breast reconstruction. The purpose of this study was to determine which clinicopathologic factors in clinically node-negative breast cancer patients may be associated with an increased risk of positive axillary nodes. Identification of these factors will allow surgeons to modify their approach to immediate autologous breast reconstruction in these high-risk patients. The relationship between presenting clinicopathologic characteristics and the incidence of axillary metastases was analyzed by chi-square test and multivariate analysis in 167 patients with invasive breast cancer and a clinically negative axilla who underwent modified radical mastectomy with an immediate free transverse rectus abdominis musculocutaneous (TRAM) flap reconstruction. Axillary nodal metastases were found in 35 percent of clinically node-negative breast cancer patients. Multivariate analysis showed that patient age of 50 years or younger (p = 0.019), T2 tumor stage or greater (p = 0.031), and presence of lymphovascular invasion on the initial biopsy specimen (p < 0.001) were independent predictors of axillary metastases in clinically node-negative patients. Based on these results, the authors propose an algorithm for decision making in clinically node-negative breast cancer patients who desire autologous breast reconstruction and sentinel lymph node biopsy. Options for immediate autologous breast reconstruction in patients undergoing mastectomy and axillary sentinel lymph node biopsy that may minimize the risk of vascular damage on reoperation include the use of the internal mammary artery and vein as recipient vessels for a free TRAM flap or a pedicled TRAM flap. If an axillary-based blood supply is used, the authors are considering the use of cadaveric dermis to isolate the pedicle of the flap away from the remaining axillary contents. New developments in breast cancer diagnosis and treatment necessitate a team approach, with increased communication between the breast surgeon and the plastic surgeon in planning surgery for these patients.  相似文献   

20.