共查询到20条相似文献,搜索用时 0 毫秒
1.
Kok RM Smith DE Dainty JR Van Den Akker JT Finglas PM Smulders YM Jakobs C De Meer K 《Analytical biochemistry》2004,326(2):129-138
We describe a liquid chromatography (LC) tandem mass spectrometry (MS-MS) method for the determination of 5-methyltetrahydrofolic acid (5-methylTHF) and folic acid concentrations and enrichments in human plasma. It was used to study absorption and initial metabolism in five volunteers with two simultaneously administered oral test doses ([(13)C(6)]folic acid in capsules and [(2)H(2)]folic acid in a drink). [(13)C(5)]5-methylTHF and [(2)H(4)]folic acid were used as internal standards. Plasma samples (2 ml) were purified using folate binding protein affinity columns, followed by a concentration step. After LC separation, folates were detected using positive electrospray ionization MS-MS under multiple reaction monitoring conditions. Calibrations were linear for 5-methylTHF over the range 1.2 x 10(-11) (=limit of detection) to 3.2 x 10(-7)mol/L and for folic acid over the range 5 x 10(-10) (=limit of detection) to 4.5 x 10(-8)mol/L. For 5-methylTHF concentration in plasma, intraassay coefficient of variation was within 8.6% (and for unlabeled 5-methylTHF it was within 2.8%) and interassay coefficient of variation was within 9.0%. For folic acid concentrations these coefficient of variations were within 7.5% and within 6.5%, respectively. The [(13)C(6)] and [(2)H(2)] isotopomers of folic acid and 5-methylTHF were measured in the plasma of each volunteer for 8h. After accounting for the time delay due to capsule opening, the modeling results showed no significant differences in absorption time, first pass effect, and elimination rate in the folic acid test doses in capsule or drink. We conclude that LC-MS-MS offers increased sensitivity for quantification of plasma concentrations and enrichments of 5-methylTHF and folic acid and is applicable to stable-isotope studies in humans. 相似文献
2.
Wang Z Wang M Tong W 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(31):3259-3266
In the field of proteomic investigation, the analysis of membrane proteins still faces many technical challenges. A fundamental question in this puzzle is how to maintain a proper solvent environment to allow the hydrophobic proteins to remain solubilized. We propose that the denaturation of membrane proteins in a highly concentrated urea solution enables them to be ionized such that ionic exchange chromatography can be employed to separate them. The membrane proteins prepared from the mouse liver were dissolved in 6M guanidine hydrochloride, 20mM Tris-HCl, pH 9.0, and loaded onto a tandem chromatography apparatus coupled with Q-Sepharose FF and Sephacryl S-200HR. These columns were able to adsorb 97.87% of the membrane protein preparations. Using a linear NaCl (0-1.0M) gradient, the bound proteins were eluted out at 0.1-1.0M NaCl, and examined by SDS-PAGE. Furthermore the protein bands underwent excision and digestion with trypsin, followed by reverse-phase chromatography for the separation of the digested peptides and ionic-trap mass spectrometry for the identification of the proteins. From the SDS-PAGE gels, the overlap between proteins from neighboring bands was only 21.34%, indicating that the anionic-size exclusion coupling chromatography efficiently separated these membrane proteins. Of a total of 392 proteins identified, 306 were membrane proteins or membrane-associated proteins. Based on the calculation of hydrophobicity, the GRAVY scores of 83 proteins are greater than, or equal to, 0.00. Taking all of this evidence together, our results revealed that this approach is satisfactory for studies on the membrane proteome from the mouse liver. 相似文献
3.
Harazono A Kawasaki N Itoh S Hashii N Ishii-Watabe A Kawanishi T Hayakawa T 《Analytical biochemistry》2006,348(2):259-268
Ceruloplasmin has ferroxidase activity and plays an essential role in iron metabolism. In this study, a site-specific glycosylation analysis of human ceruloplasmin (CP) was carried out using reversed-phase high-performance liquid chromatography with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). A tryptic digest of carboxymethylated CP was subjected to LC-ESI-MS/MS. Product ion spectra acquired data-dependently were used for both distinction of the glycopeptides from the peptides using the carbohydrate B-ions, such as m/z 204 (HexNAc) and m/z 366 (HexHexNAc), and identification of the peptide moiety of the glycopeptide based on the presence of the b- and y-series ions derived from the peptide. Oligosaccharide composition was deduced from the molecular weight calculated from the observed mass of the glycopeptide and theoretical mass of the peptide. Of the seven potential N-glycosylation sites, four (Asn119, Asn339, Asn378, and Asn743) were occupied by a sialylated biantennary or triantennary oligosaccharide with fucose residues (0, 1, or 2). A small amount of sialylated tetraantennary oligosaccharide was detected. Exoglycosidase digestion suggested that fucose residues were linked to reducing end GlcNAc in biantennary oligosaccharides and to reducing end and/or alpha1-3 to outer arms GlcNAc in triantennary oligosaccharides and that roughly one of the antennas in triantennary oligosaccharides was alpha2-3 sialylated and occasionally alpha1-3 fucosylated at GlcNAc. 相似文献
4.
Protein labeling by iTRAQ: a new tool for quantitative mass spectrometry in proteome research 总被引:3,自引:0,他引:3
A novel, MS-based approach for the relative quantification of proteins, relying on the derivatization of primary amino groups in intact proteins using isobaric tag for relative and absolute quantitation (iTRAQ) is presented. Due to the isobaric mass design of the iTRAQ reagents, differentially labeled proteins do not differ in mass; accordingly, their corresponding proteolytic peptides appear as single peaks in MS scans. Because quantitative information is provided by isotope-encoded reporter ions that can only be observed in MS/MS spectra, we analyzed the fragmentation behavior of ESI and MALDI ions of peptides generated from iTRAQ-labeled proteins using a TOF/TOF and/or a QTOF instrument. We observed efficient liberation of reporter ions for singly protonated peptides at low-energy collision conditions. In contrast, increased collision energies were required to liberate the iTRAQ label from lysine side chains of doubly charged peptides and, thus, to observe reporter ions suitable for relative quantification of proteins with high accuracy. We then developed a quantitative strategy that comprises labeling of intact proteins by iTRAQ followed by gel electrophoresis and peptide MS/MS analyses. As proof of principle, mixtures of five different proteins in various concentration ratios were quantified, demonstrating the general applicability of the approach presented here to quantitative MS-based proteomics. 相似文献
5.
A facile proteomic quantification method, fluorescent labeling absolute quantification (FLAQ), was developed. Instead of using MS for quantification, the FLAQ method is a chromatography-based quantification in combination with MS for identification. Multidimensional liquid chromatography (MDLC) with laser-induced fluorescence (LIF) detection with high accuracy and tandem MS system were employed for FLAQ. Several requirements should be met for fluorescent labeling in MS identification: Labeling completeness, minimum side-reactions, simple MS spectra, and no extra tandem MS fragmentations for structure elucidations. A fluorescence dye, 5-iodoacetamidofluorescein, was finally chosen to label proteins on all cysteine residues. The fluorescent dye was compatible with the process of the trypsin digestion and MALDI MS identification. Quantitative labeling was achieved with optimization of reacting conditions. A synthesized peptide and model proteins, BSA (35 cysteines), OVA (five cysteines), were used for verifying the completeness of labeling. Proteins were separated through MDLC and quantified based on fluorescent intensities, followed by MS identification. High accuracy (RSD% < 1.58) and wide linearity of quantification (1-10(5) ) were achieved by LIF detection. The limit of quantitation for the model protein was as low as 0.34 amol. Parts of proteins in human liver proteome were quantified and demonstrated using FLAQ. 相似文献
6.
Calvo E Pucciarelli MG Bierne H Cossart P Albar JP García-Del Portillo F 《Proteomics》2005,5(2):433-443
Genome analyses have revealed that the Gram-positive bacterial species Listeria monocytogenes and L. innocua contain a large number of genes encoding surface proteins predicted to be covalently bound to the cell wall (41 and 34, respectively). The function of most of these proteins is unknown and they have not even been identified biochemically. Here, we report the first characterization of the Listeria cell wall proteome using a nonelectrophoretic approach. The material analyzed consisted of a peptide mixture obtained from a cell wall extract insoluble in boiling 4% SDS. This extract, containing peptidoglycan (intrinsically resistant to proteases) and strongly associated proteins, was digested with trypsin in a solution with 0.01% SDS, used to favor protein digestion throughout the peptidoglycan. The resulting complex peptide mixture was fractionated and analyzed by two-dimensional nanoliquid chromatography coupled to ion-trap mass spectrometry. A total of 30 protein species were unequivocally identified in cell wall extracts of the genome strains L. monocytogenes EGD-e (19 proteins) and L. innocua CLIP11262 (11 proteins). Among them, 20 proteins bearing an LPXTG motif recognized for covalent anchoring to the peptidoglycan were identified. Other proteins detected included peptidoglycan-lytic enzymes, a penicillin-binding protein, and proteins bearing an NXZTN motif recently proposed to direct protein anchoring to the peptidoglycan. The marked sensitivity of the method makes it highly attractive in the post-genome era for defining the cell wall proteome in any bacterial species. This information will be useful to study novel protein-peptidoglycan associations and to rapidly identify new targets in the surface of important bacterial pathogens. 相似文献
7.
An electrospray mass spectrometric method for the quantification of the depolarizing neuromuscular blocking agent succinylcholine (SUX) is described. An extraction method compatible with direct infusion inlet was developed and leads to an analysis cycle time of 7--8 min instead of 25 min that would be required for HPLC inlet. SUX was extracted from human plasma on C1 solid-phase cartridges and was analyzed using positive ion electrospray tandem mass spectrometry (ESI-MS/MS). SUX plasma concentrations were determined by a stable isotope dilution assay using hexadeuterosuccinylcholine diiodide (SUXd6) as the internal standard. The calibration curve was prepared using the ratio of intensities of the major product ions in the collision-induced dissociation spectrum for known concentration ratios of SUX and SUXd6 in plasma. Calibration curves for the quantification were linear from 25 to 4000 ng/ml. For intraday precision, CV were < or =6% and accuracy ranged from 98 to 103%. For the interday precision, CV were < or =10% and accuracy ranged from 90 to 102%. This method is specific, sensitive, reproducible, and practical in a clinical setting. 相似文献
8.
Schreiber D Harlfinger S Nolden BM Gerth CW Jaehde U Schömig E Klosterkötter J Giuffrida A Astarita G Piomelli D Markus Leweke F 《Analytical biochemistry》2007,361(2):162-168
We developed a new selective liquid chromatography-electrospray ionization-tandem mass spectrometry method for the identification and quantification of anandamide (AEA), an endogenous cannabinoid receptor ligand, and other bioactive fatty acid ethanolamides (FAEs) in biological samples. Detection limit (0.025 pmol for AEA and 0.1 pmol for palmitoylethanolamide (PEA) and oleoylethanolamide (OEA)) and quantification limit (0.2 pmol for AEA and 0.4 pmol for OEA and PEA) were in the high fmol to low pmol range for all analytes. Linear correlations (r(2)=0.99) were observed in the calibration curves for standard AEA over the range of 0.025-25 pmol and for standard PEA and OEA over the range of 0.1-500 pmol. This method provides a time-saving and sensitive alternative to existing methods for the analysis of FAEs in biological samples. 相似文献
9.
Bifidobacteria are Gram-positive prokaryotes that naturally colonize the human gut where they exert several health-promoting effects. The present paper reports the use of a strong cation exchange-reversed-phase-tandem mass spectrometry strategy to catalogue the most abundantly expressed proteins of a probiotic Bifidobacterium infantis strain. A global view of the B. infantis proteome was obtained. The bimodal representation of the proteins identified by mass spectrometry provides the first theoretical two-dimensional map of protein distribution for this organism. Among the 136 proteins identified by multidimensional protein identification technology (MudPIT) analysis, 118 showed the highest similarity with the translated sequences of B. longum genome, two proteins were similar to other Bifidobacterium species and the remaining 16 were similar to different genera. Specific biological activities have been assigned to 115 identified proteins, whereas 21 have been referred to the group of hypothetical proteins. The MudPIT approach allowed us to identify high mass and basic isoelectric point proteins that are generally challenging to visualize using the traditional two-dimensional electrophoresis technique. Redundancy in peptide and protein identification using the double chromatography technique was also evaluated. 相似文献
10.
The newly developed SMART Digest™ kit was applied for the sample preparation of human immunoglobulin G1 (hIgG1) in rat serum prior to qualitative and quantitative analyses by liquid chromatography tandem mass spectrometry (LC–MS/MS). The sequence coverages obtained for the light and heavy chains of hIgG1A were 50 and 76%, respectively. The calibration curve was linear from 1.00 to 1000 μg/ml for three of four generic peptides. Overall, the SMART Digest™ kit resulted in similar quantitative data (linearity, sensitivity, accuracy, and precision) compared with the pellet digestion protocol. However, the SMART Digest™ required only 2 h of sample preparation with fewer reagents. 相似文献
11.
Sahasranaman S Tang Y Biniasz D Hochhaus G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,819(1):175-179
A robust, rapid, selective and sensitive liquid chromatography-negative atmospheric pressure chemical ionization (LC-(APCI(-))-MS-MS) method has been developed for the quantification of mometasone furoate (MF) in human plasma utilizing a solid-phase extraction clean-up step and 13C-fluticasone propionate as internal standard. The intra- and inter-day coefficients of variation were < or = 15% and the lower limit of quantification (LLOQ) was 15 pg/ml. This method is ideally suited for pharmacokinetic investigations of low MF levels following inhalation of MF. 相似文献
12.
Quantitative analysis of tissue folate using ultra high-performance liquid chromatography tandem mass spectrometry 总被引:1,自引:0,他引:1
The tissue distribution of folate in its numerous coenzyme forms may influence the development of disease at different sites. For instance, the susceptibility of human colonic mucosa to localized folate deficiency may predispose to the development of colorectal cancer. We report a sensitive and robust ultra high-performance liquid chromatography (UHPLC) tandem mass spectrometry method for quantifying tissue H4folate, 5-CH3-H4folate, 5-CHO-H4folate, folic acid, and 5,10-CH+-H4folate concentration. Human colonic mucosa (20–100 mg) was extracted using lipase and conjugase enzyme digestion. Rapid separation of analytes was achieved on a UHPLC 1.9-μm C18 column over 7 min. Accurate quantitation was performed using stable isotopically labeled (13C5) internal standards. The instrument response was linear over physiological concentrations of tissue folate (R2 > 0.99). Limits of detection and quantitation were less than 20 and 30 fmol on column, respectively, and within- and between-run imprecision values were 6–16%. In colonic mucosal samples from 73 individuals, the average molar distribution of folate coenzymes was 58% 5-CH3-H4folate, 20% H4folate, 18% formyl-H4folate (sum of 5-CHO-H4folate and 5,10-CH+-H4folate), and 4% folic acid. This assay would be useful in characterizing folate distribution in human and animal tissues as well as the role of deregulated folate homeostasis on disease pathogenesis. 相似文献
13.
Gaucher SP Taylor SW Fahy E Zhang B Warnock DE Ghosh SS Gibson BW 《Journal of proteome research》2004,3(3):495-505
Recent evidence suggests that mitochondria are closely linked with the aging process and degenerative disorders such as Alzheimer's disease and Parkinson's disease. Thus, there has been increasing interest in cataloging mitochondrial proteomes to identify potential diagnostic and therapeutic targets. We have previously reported results of a one-dimensional electrophoresis/liquid chromatography MS/MS study to characterize the proteome of normal human heart mitochondria (Taylor et al. Nat. Biotechnol. 2003, 21, 281-286). We now report two subsequent studies where multidimensional liquid chromatography MS/MS was investigated as an alternative means for characterizing the same sample. 相似文献
14.
An online sample extraction chiral bioanalytical method was developed and validated for the quantification of terbutaline, a beta2-selective adrenoceptor agonist, spiked into human plasma by using two extraction columns and a chiral stationary phase (CSP) in conjunction with liquid chromatography tandem mass spectrometry (LC-MS/MS). In this method, two Oasis HLB extraction columns were used in parallel for plasma sample purification and a Chirobiotic T CSP was used for enantiomeric separation. Atmospheric pressure chemical ionization MS/MS was employed in multiple reaction monitoring mode for the detection and quantification. Subsequent to the addition of an internal standard solution, the plasma samples were directly injected onto the system for extraction and analysis. This method allowed the use of one of the extraction columns for purification while the other was being equilibrated. Hence, the time required for reconditioning the extraction columns did not contribute to the total analysis time per sample, which resulted in a shorter run time and higher throughput. A lower limit of quantification of 1.0 ng/mL was achieved using only 50 microliter of human plasma. The method was validated with a dynamic range of 1.0-200 ng/mL. The intra- and interday precision was no more than 11% CV and the assay accuracy was between 94-106%. 相似文献
15.
Proteomics can be thought of as an attempt to understand the information encoded in genomic sequences from the perspective
of proteins; i.e. the structure, function and regulation of biological processes at the protein level. In practice it stands
in stark contrast to the hypothesis-driven serial approach practiced in the last century that was so successful for protein
chemists and is built on the basic understanding of protein physicochemical properties developed during that era. Proteomics
attempts to study biological processes comprehensively or globally by systematic parallel analysis of proteins expressed in
a cell. While there are many analytical techniques in use and under development in proteomics, mass spectrometry is currently
one of the field's most important discovery-based tools. This article will review some of the current approaches for qualitative
and quantitative uses of tandem mass spectrometry in the field of proteomics specifically avoiding a discussion of the use
of gel electrophoresis prior to mass spectrometry.
Electronic Publication 相似文献
16.
Kagedan D Lecker I Batruch I Smith C Kaploun I Lo K Grober E Diamandis EP Jarvi KA 《Clinical proteomics》2012,9(1):2
Background
Prostatitis is an inflammation of the prostate gland which affects approximately 10% of men. Despite its frequency, diagnosing prostatitis and monitoring patient response to treatment remains frustrating. As the prostate contributes a substantial percentage of proteins to seminal plasma, we hypothesized that a protein biomarker of prostatitis might be found by comparing the seminal plasma proteome of patients with and without prostatitis. 相似文献17.
The measurement of 5-methyltetrahydrofolic acid (5 MT) blood levels is one of several factors used to diagnose folate deficiency in humans. 5 can be selectively purified from either human plasma or human serum via solid-phase extraction procedures and specifically detected and quantified in the extracts with liquid chromatography/isotope-dilution electrospray-ionization mass spectrometry. Two different, yet complementary, solid-phase extraction-liquid chromatography/mass spectrometry methods have been developed and applied to the quantification of 5 MT from such extracts. One method utilizes the high-affinity folate-binding protein from cow's milk coupled with multiple-reaction-monitoring-mode tandem mass spectrometry while the other method utilizes reversed-phase C(18) extraction followed by selected-ion-monitoring-mode mass spectrometry. The accuracy of each method is assessed through a comparative determination of 5 MT levels in homogenous plasma and serum pools. Additionally, each method is compared and evaluated against the "total folate" results provided by routine radioassay and microbiological assay determinations. On the basis of the experimental data presented in this report, it is suggested that both methods have the capacity to serve as potential reference methods for the quantification of circulating 5MT in plasma or serum. 相似文献
18.
We describe an improved assay for platelet-activating factor (PAF; 1-O-alkyl-2-acetyl-sn-glycero-3-phosphocholine) using HPLC-tandem mass spectrometry (LC-MS/MS). The present method can readily detect as little as 1 pg (1.9 fmol) of PAF, a significant improvement over previously described LC-MS/MS methods, and gives a linear response up to 1,000 pg of PAF. Our method also overcomes the artifacts from isobaric lipids that have limited the usefulness of certain existing LC-MS/MS assays for PAF. In the course of these studies, we detected three novel lipid species in human neutrophils. One of the novel lipids appears to be a new molecular species of PAF, and the other two have chromatographic and mass spectrometric properties consistent with stearoyl-formyl-glycerophosphocholine and oleoyl-formyl-glycerophosphocholine. These observations identify previously unknown potential interferences in the measurement of PAF by LC-MS/MS. Moreover, our data suggest that the previously described palmitoyl-formyl-glycerophosphocholine is not unique but rather is a member of a new and poorly understood family of formylated lipids. 相似文献
19.
Human saliva contains a large number of proteins and peptides (salivary proteome) that help maintain homeostasis in the oral cavity. Global analysis of human salivary proteome is important for understanding oral health and disease pathogenesis. In this study, large-scale identification of salivary proteins was demonstrated by using shotgun proteomics and two-dimensinal gel electrophoresis-mass spectrometry (2-DE-MS). For the shotgun approach, whole saliva proteins were prefractionated according to molecular weight. The smallest fraction, presumably containing salivary peptides, was directly separated by capillary liquid chromatography (LC). However, the large protein fractions were digested into peptides for subsequent LC separation. Separated peptides were analyzed by on-line electrospray tandem mass spectrometry (MS/MS) using a quadrupole-time of flight mass spectrometer, and the obtained spectra were automatically processed to search human protein sequence database for protein identification. Additionally, 2-DE was used to map out the proteins in whole saliva. Protein spots 105 in number were excised and in-gel digested; and the resulting peptide fragments were measured by matrix-assisted laser desorption/ionization-mass spectrometry and sequenced by LC-MS/MS for protein identification. In total, we cataloged 309 proteins from human whole saliva by using these two proteomic approaches. 相似文献
20.
Tang C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2010,878(31):3317-3322
A sensitive, simple and feasible method has been developed and validated for the simultaneous determination of three diastereoisomers of hexabromocyclododecane (HBCD) in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS). The simple pretreatment generally involved protein precipitation with methanol (MeOH). The separation was performed with a C18 reverse phase column. The mobile phases were 5mM ammonium acetate (NH(4)AC) in water and acetonitrile (ACN). The mass spectrometer was operated using negative electrospray ionization (ESI) source and the data acquisition was carried out with multiple reaction monitoring (MRM) mode. The analyte quantifications were performed by external standard method with matrix-matched calibration curves. The method was partially validated with the evaluations of accuracy, precision, linearity, limit of quantification (LOQ), limit of detection (LOD), recovery, matrix effect and carryover effect. With the present method, the intra-batch accuracies were 94.7-104.3%, 91.9-109.3% and 89.8-105.0% for α-, β- and γ-HBCD, respectively. And the inter-batch accuracies were ranged from 94.2% to 109.7%. Both intra-batch and inter-batch precisions (relative standard deviation, RSD, %) of the analytes were no more than 11.2%. The recoveries were from 79.0% to 108.9% and the LOQ was 10pg/mL for each diastereoisomer. The linear range was 10-10,000pg/mL with the linear correlation coefficient R(2)>0.996. No significant matrix effect and carryover effect of the analytes were observed in this study. This method is in possession of sufficient resolution, high sensitivity as well as selectivity and convenient to be applied to the trace determination of HBCDs in human plasma. 相似文献