首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A high-performance liquid chromatographic method for the determination of metformin, an oral antidiabetic agent, in plasma is described. Plasma samples containing the internal standard, phenformin, are eluted through Amprep extraction columns before injection into the chromatographic column, packed with μBondapak phenyl. The eluent is monitored at 236 nm. At a mobile phase flow-rate of 1.35 ml/min, the retention times of metformin and phenformin are 2.8 and 5.6 min, respectively. The intra-day coefficients of variation are 1.5 and 4.3% at metformin concentrations of 0.05 and 1 mg/l, respectively.  相似文献   

2.
A simple, selective and sensitive high-performance liquid chromatographic method with spectrophotometric detection was developed for the determination of antihyperglycemic agent metformin in human plasma using a novel sample extraction procedure. Liquid-liquid extraction of metformin and ranitidine (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (50:50, v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a silica column (250 mmx4.6 mm, 5 microm) under isocratic elution with acetonitrile-40 mM aqueous sodium dihydrogen phosphate (25:75, v/v), pH 6. The limit of quantification (LOQ) was 15.6 ng/ml and the calibration curves were linear up to 2000 ng/ml. The mean absolute recoveries for metformin and internal standard using the present extraction procedure were 98 and 95%, respectively. The intra- and inter-day coefficient of variation and percent error values of the assay method were all less than 8.3%.  相似文献   

3.
A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of metformin in human plasma. The method entailed direct injection of the plasma sample after deproteination using perchloric acid. The mobile phase comprised 0.01 M potassium dihydrogen orthophosphate (pH 3.5) and acetonitrile (60:40, v/v). Analyses were run at a flow-rate of 1.0 ml/min with the detector operating at a detection wavelength of 234 nm. The method is specific and sensitive, with a quantification limit of approximately 60 ng/ml and a detection limit of 15 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery value was about 97%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The calibration curve was linear over a concentration range of 62.5–4000 ng/ml.  相似文献   

4.
A simple, selective, sensitive and precise high-performance liquid chromatographic plasma assay for the hypoglycemic agent metformin is described. Acidified samples of plasma were deproteinated with acetonitrile, washed with dichloromethane and the resulting supernatant injected. Chromatography was performed at 40°C by pumping a mobile phase of acetonitrile (250 ml) in pH 7, 0.03 M diammonium hydrogen phosphate buffer (750 ml) at a flow-rate of 1 ml/min through a silica column. Metformin and the internal standard (atenolol) were detected at 240 nm and were eluted 7.8 and 6.8 min, respectively, after injection. No endogenous substances were found to interfere. Calibration curves were linear (r>0.999) from 10 to 2000 ng/ml. The absolute recovery of both metformin and atenolol was greater than 76%. The detection limit and limit of quantitation were 2.5 and 10 ng/ml, respectively. The intra- and inter-day precision (C.V.) was 12%, or less, and the accuracy was within 6.2% of the nominal concentration. This method is suitable for clinical investigation and monitoring metformin concentration.  相似文献   

5.
A simple, sensitive and rapid high-performance liquid chromatographic (HPLC) procedure to determine total serum acyclovir concentrations is described. The assay involves a heat inactivation step at 56°C to prevent risk of infection, ultrafiltration as a pretreatment step prior to ion-pair reversed-phase liquid chromatography using guanosine as internal standard, and ultraviolet detection at 254 nm. This method has excellent recovery (97–100%), linearity (0.5–100 mg/l) and precision (1.2–8.0% coefficient of variation). The detection limit is 50 μg/l. The assay proved to be suitable for therapeutic drug monitoring of acyclovir.  相似文献   

6.
A new HPLC assay using UV detection (200 nm) was developed to determine ethambutol (EMB) concentrations in plasma. Following extraction (0.1 ml plasma) with chloroform, EMB and octylamine (used as internal standard) were derivatized with phenylethylisocyanate. Quantitation in plasma was achieved at 200 nm. There were no interferences from endogenous compounds. Intra- and inter-day variabilities were lower than 5.2 and 7.6%, respectively. The limit of quantitation of the method was 0.2 μg/ml. In plasma, ethambutol was found to be stable for at least one month when samples were stored at −20°C. This assay was applied to the therapeutic monitoring of EMB concentrations in 19 patients suffering from tuberculosis.  相似文献   

7.
A rapid and simple high-performance liquid chromatographic (HPLC) assay for the determination of metformin in human plasma and breast milk is described. After proteins were precipitated with acetonitrile, metformin and the internal standard buformin were resolved on a cation-exchange column and detected by UV detection at 236 nm. Standard curves were linear over the concentration range 20.0-4000 microg/l. Intra- and inter-day coefficients of variation were <9.0% and the limit of quantification was around 20 microg/l.  相似文献   

8.
An isocratic reversed-phase high-performance liquid chromatographic method was developed to determine free didanosine concentrations in human serum. An ultrafiltration technique was used to recover didanosine from the samples. Didanosine was analyzed using a 150 mm × 3.9 mm I.D. Nova-Pak phenyl column and a mobile phase of 0.02 M sodium citrate (pH 5)-isopropanol (97.5:2.5, v/v) with detection set at 250 nm. Linearity was verified from 25 to 3000 ng/ml. The limit of detection at a signal-to-noise ratio of 3 was 25 ng/ml. The mean recovery of didanosine added to serum at 50, 100, 250 and 750 ng/ml was 97.4%, 97.3%, 92.9% and 95.4%, respectively. A within-day variation of 3.6% at 50 ng/ml and 1.7% at 250 ng/ml, and a day-to-day variation of 9.3% at 50 ng/ml and 3.6% at 230 ng/ml were found. Stability studies indicated that didanosine is stable in serum for at least 8.5 months at 20°C, 4°C and −20°C.  相似文献   

9.
Interference with the UV absorbance of medrogestone by endogenous steroids in plasma was prevented by reacting plasma with oxalyl chloride. The reduction of interference was effective when oxalyl chloride was in the range 10–50 μl/ml plasma. Reaction of oxalyl chloride with plasma for 10 min could reduce interference approximately 5.5-fold, and there was no significant reduction after 30 min. The limit of quantitative concentration for medrogestone in HPLC was 1 ng/ml. The standard curves were linear with the correlation coefficient greater than 0.999 in the range of 1–30 ng/ml. The coefficients of variation of both intra- and inter-day mean values were <12% and <10% of the actual values, respectively. The developed method for plasma sample preparation and the evaluated HPLC condition were further applied to an in vivo pharmacokinetic study.  相似文献   

10.
A rapid and simple method for determination of the novel antiepileptic compound gabapentin [1-(aminomethyl)cyclohexaneacetic acid] in plasma is described. Blank human plasma was spiked with gabapentin (1.0–10.0 μg/ml) and internal standard [1-(aminomethyl)-cycloheptaneacetic acid; 5.0 μg/ml]. Individual samples were treated with 2 M perchloric acid, centrifuged and then derivatised with o-phthalaldehyde-3-mercaptopropionic acid. Separation was achieved on a Beckman Ultrasphere 5 μm reversed-phase column with mobile phase consisting of 0.33 M acetate buffer (pH 3.7; containing 100 mg/l EDTA)-methanol-acetonitrile (40:30:30, v/v). Eluents were monitored by fluorescence spectroscopy with excitation and emission wavelengths of 330 and 440 nm, respectively. The calibration curve for gabapentin in plasma was linear (r=0.9997) over the concentration range 1.0–10.0 μg/ml. Recovery was seen to be 90%. The inter- and intra-assay variations for three different gabapentin concentrations were 10% throughout. The lower limit of quantitation was found to be 0.5 μg/ml. Chromatography was unaffacted by a range of commonly employed antiepileptic drugs or selected amino acids.  相似文献   

11.
A sensitive method for the determination of boldine in blood plasma is described. The procedure involves a direct pH-buffered chloroform extraction of boldine from blood plasma, followed by its assay under isocratic conditions by HPLC with UV detection. The extraction recovery is excellent, and sensitivity and precision of the method are very high, when applied to plasma samples containing pharmacologically relevant concentrations of boldine.  相似文献   

12.
13.
14.
15.
An assay has been developed and validated for the routine monitoring of mivacurium in plasma. It consists of liquid-liquid extraction with dichloromethane and high-performance liquid chromatography with fluorometric detection (excitation and emission wavelengths 220 nm and 320 nm, respectively). A Spherisorb C1 5 μm column and a mobile phase containing acetonitrile, KH2PO4 and methanol are used. At a flow-rate of 1 ml/min, a concentration gradient is applied. The detection limit is approximately 1 ng/ml in plasma. For the separation of stereoisomeres, the Spherisorb SCX 10 μm column and acetonitrile-Na2SO4 as a mobile phase can be used. The assay shows good linearity over the range 1–1000 ng/ml. The accuracy and precision allows the utilisation in clinical pharmacokinetic studies.  相似文献   

16.
17.
18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号