首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid solid phase assay for detection of single HLA-antigens on platelets was developed. The platelets were attached to the surface of polystyrene microtitre plate wells by means of a sodium carbonate buffer and centrifugation. Uncovered areas were blocked by a gelatin blocking buffer. After incubation with commercially available anti-HLA-sera the bound anti-HLA-specific antibodies directed against HLA-antigens present on the platelets were made visible by anti-IgG-coated indicator red cells and a brief centrifugation. A positive result, meaning the presence of an HLA-antigen, was indicated by a slight red cell adherence over the reaction surface. In the absence of the HLA-antigen no binding occurred and the indicator red cells formed a small red disc-like pellet.  相似文献   

2.
The sequence encoding an E2 main antigen glycoprotein of the C strain of classical swine fever virus (CSFV) was highly expressed in the host cell E. coli BL21-CodonPlus (DE3)-RIL using the pGEX-4T-1 expression vector and the soluble recombinant product was purified with Glutathione Sepharose TM<'4B> by centrifugation. The soluble recombinant protein showed good immune reactions and was confirmed by Western blot using anti-CSFV-specific antibodies. Then an indirect ELISA with the purified E2 protein as the coating antigen was established to detect antibody against CSFV. The result revealed that the optimal concentration of coated antigen was 0.6 μg/well and the optimal dilution of serum was 1:80. The positive cut-off value of this ELISA assay was OD<,tested serum>/OD<,negative serum>≥2.1- The E2-ELISA method was evaluated by comparison with the indirect hemagglutination test (IHAT). When a total of 100 field serum samples were tested the sensitivity and specificity were 90.3% and 94.7% respectively. Specificity analysis showed that there were no cross-reactions between BVD serum and the purified E2 protein in the E2-ELISA.  相似文献   

3.
Leukocyte oxidative function was investigated in a more physiological milieu than currently used in the chemiluminescence (CL) technique. Heparinized blood was mixed with 6% dextran-T70 (9:1) and the leukocyte-rich plasma obtained without centrifugation was used for the CL experiments (phagocyte count was adjusted to 0.7 × 106/mL with Hanks' buffer) (method A). In this medium, phagocytes responded to stimulation by opsonized zymosan, producing strong luminescence in the presence of 0.5 m? mol/L MCLA. CL was inhibited by superoxide dismutase, suggesting that the luminescence reaction was attributable to O. Granulocytes were also prepared by the usual method involving centrifugation and were then suspended in plasma (method B). Oxidative function of phagocytes prepared by the two methods was studied together with whole blood as aliquots diluted with Hanks' buffer up to a factor of 1000. Luminescence reached a peak value at a dilution factor of 16, but at very high dilutions luminescence decreased sharply. Significantly higher luminescence values were obtained with samples from method A. Luminescence of whole blood peaked at a dilution factor of 248 but it was less than the value obtained using samples prepared by method A or B. As samples prepared by method A contain all the leukocyte populations, platelets, residual red cells and plasma proteins, the assay of leukocyte-generated reactive oxygens using CL is attained in more physiological conditions than method B in which leukocytes may be damaged owing to repeated centrifugation and hypotonic shock.  相似文献   

4.
Modified counter immunoelectrophoresis was standardized with respect to dilution of tissue culture antigen and indicator serum, the incubation time for neutralization and the effect of an electric current. The technique was found to be sensitive enough to detect a minimum level of antibodies (0.5 IU/ml) by using a 16 mA current per slide for 2 h, indicator serum of 15 IU/ml and the use of an antigen at a concentration of 1:35. Above all, the incubation period did not affect the neutralization of the virus. The test was also applied to the detection of rabies-specific antibody levels in 73 human sera. The test was found to be simple, quick and economical for titration of rabies antibodies.  相似文献   

5.
Monoclonal antibodies against the cell surface were produced by immunizing mice with endometrial scrapings prepared from 6-day pregnant rabbits. Spleen cells from an immune mouse were fused with myeloma cells and cultured by standard hybridoma technology methods. Hybridoma supernatants were screened for reaction with the apical epithelial surface by immunohistochemistry on frozen sections of uterus from 6-day pregnant rabbits, and positive colonies were cloned by limiting dilution. Ascites fluid was produced in mice from hybridoma clones that gave a consistent pattern of apical epithelial surface staining through 6 sub-clonings. Antibodies in the ascites fluid were tested by immunohistochemistry on frozen sections of uterus, oviduct, lung, liver and kidney from nonpregnant or 6-day pregnant rabbits. At a dilution of 1:5000, the antibodies recognized an antigen that was specific to the apical surface of luminal but not glandular epithelium of the 6-day pregnant uterus and could not be detected in the nonpregnant uterine epithelium. At higher concentrations of antibody (1:100 to 1:1000), crossreaction was seen with antigens in stromal and myometrial cells of pregnant and nonpregnant uterus. At a dilution of 1:5000, the antibody also crossreacted with some components of lung, liver and kidney but without discriminating between the two reproductive states. In the oviduct, staining of the surface epithelium was specific to the pregnant state. We conclude that this monoclonal antibody has a high affinity for a luminal epithelial cell surface antigen in the reproductive tract of the pregnant rabbit and shows multiple organ reactivity with other tissues that is not affected by pregnancy. This antigen will provide a useful cell surface marker of epithelial differentiation in the progestational reproductive tract.  相似文献   

6.
An IF–test modified to increase sensitivity was used to detect the presence of Babesia divergens specific IgM antibodies. It consisted of three steps: (1) the incubation of Babesia antigen with test serum, followed by; (2) its incubation with protein A; and (3) the addition of rabbit anti-bovine IgM bound to protein A, which was bound with FITC. Compared to the conventional IF–technique, this modified IF-technique detected bovine anti-Babesia-IgM in test serum at a two–fold lower dilution and with a diminished background staining. This modified IF-technique improves the possibilities for studying class Μ antibody in the serum of cattle which have been infected with B. divergens. It is possible to determine whether a calf s antibody response is due to maternally transmitted antibodies or actively acquired antibodies by determining the presence of each of the classes of immunoglobulin against B. divergens present in the calf s serum.  相似文献   

7.
The pathogenesis and tissue damage that accompanies destruction of platelets in immune thrombocytopenias (IT) is still not understood very well and in addition to platelets, other cells (e.g. endothelial cells, CD34+ hematopoietic stem/progenitors) may also become affected. Based on our previous work that platelet antigens (e.g., CD41) may be transferred by platelet-derived microvesicles (PMV) to the surface of other cells, we asked if platelet derived-antigens, especially those that are involved in the formation of anti-platelet antibodies in IT (e.g., against antigen HPA 1 a) could be also transferred by similar mechanism. To address this issue normal human CD34+ cells, human umbilical vein-endothelial cells (HUVEC) and monocytic cell line THP-1 were incubated with PMV derived from HPA1a+ donors. We noticed that the HPA1a antigen is highly expressed on PMV-derived from the HPAla positive platelets and is transferred in PMV-dependent manner to the surface of CD34+ cells, HUVEC and monocytic THP-1 cells. These cells covered with HPA1a positive PMV but not by PMV derived from HPAla negative platelets reacted with anti-HPA1a antibodies derived from the alloimmunized pregnant women. More importantly, human hematopoietic cells that were preincubated with HPA1a+ PMV and subsequently exposed to anti-HPA 1 a serum and human NK cells, become subject to elimination by antibody dependent cell cytotoxicity ADCC. Thus, we postulate that PMV-dependent transfer of antigens may playing an important role in "expanding" the population of target cells that may be affected by anti-platelet antibodies and explain several pathologies that accompany IT (e.g. damage of endothelium, cytopenias).  相似文献   

8.
The numbers of antigen-reactive antibody-secreting cells, levels of parasite antigen-specific serum antibodies and numbers of red blood cells staining positive for surface immunoglobulin were determined for susceptible and resistant mouse strains following infection with Plasmodium yoelii 17x. As a control, these parameters also were measured using antigen prepared from normal red blood cells. The relatively susceptible C57BL/6 mice produced more antigen-specific antibody-secreting cells and had higher levels of immunoglobulin positive red blood cells than did DBA/2 mice, but the DBA/2 mice had more antigen-specific IgG in their sera. Both mouse strains possessed cells secreting antibody reactive with soluble normal red blood cell antigen; however, C57BL/6 mice had more IgG positive unparasitized RBC than did DBA/2 mice. Despite possessing fewer antibody positive normal RBC, DBA/2 mice had significantly higher levels of serum antibodies that reacted with soluble red blood cell antigen. These data indicate that levels of serum antibody may not reflect the amounts of antibody produced and that use of any single assay to assess the magnitude of the antibody response may give rise to misleading results.  相似文献   

9.
M Takayama  A Oya 《Biken journal》1981,24(3):109-118
A one-point serum dilution method for determination of neutralizing antibody in human sera to varicella-zoster (V-Z) virus instead of the serial serum dilution method was investigated. Focus counting was performed under a microscope on day 5 to 6 after inoculation of V-Z virus into 6-well plastic trays in which human embryonic lung cells were grown. A table was constructed to estimate the ND50 titers by the per cent reduction of the focus count from the control at only one dilution of test sera. The estimated ND50 values agreed well with those determined by the serial serum dilution method. Test sera showed a slight nonspecific reactivity at low serum dilutions, but reliable results could usually be obtained at a serum dilution of 1:8 or more. This method, which saves materials and labor, was applied to the quantification of neutralizing antibody against V-Z virus in human sera with satisfactory accuracy and reproducibility.  相似文献   

10.
K Toba  E F Winton  R A Bray 《Cytometry》1992,13(1):60-67
We have developed an improved technique for triple staining that permits the simultaneous flow cytofluorometric analysis of cell surface antigens, bromodeoxyuridine incorporation into DNA, and DNA quantification using 7-amino-actinomycin D. PHA-activated human peripheral blood lymphocytes were incubated with bromodeoxyuridine and stained for cell surface phenotype with phycoerythrin-labeled monoclonal antibodies. Stained cells were fixed serially with 1% paraformaldehyde and 45% ethanol. Fixed cells were sequentially stained with an anti-BrdUrd monoclonal antibody followed by a FITC-conjugated goat anti-mouse antibody and incubated with 7-amino-actinomycin D. Hypotonic buffer was employed for all procedures after fixation. Stained-fixed cells were analyzed by flow cytofluorometry for simultaneous green (525 nm), orange (570 nm), and red (greater than 650 nm) fluorescence. Utilizing this staining technique, we were able to analyze simultaneously cell phenotype, DNA synthesis, and total cellular DNA content with single laser excitation.  相似文献   

11.
Immunoadsorbents consisting of rabbit anti-DR antibodies bound to Staphylococcus aureus were used to bind DR antigens from NP40 cellular extracts of cultured B lymphoid cells. When injected into rabbits, these DR antibody absorbents elicited the production of antibodies that were shown by both serologic and immunochemical techniques to react specifically with the DR antigen molecule. A rosette inhibition assay with B lymphoid cells and anti-DR xenoantisera was used to detect DR antigens in human serum. DR serum antigens could be found in an enriched preparation of serum lipoproteins obtained by centrifugation in KBr. In addition, sera from some patients with neoplastic diseases contained higher levels of DR serum antigens than those found in normal individuals.  相似文献   

12.
RGNTF单抗与多抗的特性和抑制作用(简报)   总被引:1,自引:0,他引:1  
We have immunized Balb/c mice and rabbits with a minute quantity of a 30 kD neuronotrophic factor which was isolated from the extract of newborn rat tectum (Te) by Phast System gel electrophoresis. Splenic cells from the immunized mice were hybridized with NS-1 mouse myeloma cells. Three clones were selected from 576 wells of hybridomas and were capable of secreting monoclonal antibodies specific to the retinal ganglion neuronotrophic factor (RGNTF-MAbs), namely A1, D3 and E8. Subtyping of the three monoclonal antibodies revealed that A1 and D3 are IgG3 and E8 is IgM. They maintained secreting antibodies even after six months of culturing in vitro. In order to determine the specificities of these antibodies, we have used their ascites fluids containing antibodies at a different dilutions to study their effects on the survival of retinal ganglion cells in vitro. The results indicated that at the dilution ranges of 1:250 to 2000, all three monoclonal antibodies exhibited inhibition on the survival of retinal ganglion cells and the inhibition increased with increases in antibody concentrations; especially at a dilution of 1:250, the E8 monoclonal antibody reaching 70% inhibition and A1 and D3 reaching 66% and 62% inhibition, respectively. Polyclonal antibodies from rabbits exhibited similar but weaker results of inhibition. We can conclude that the monoclonal and polyclonal antibodies can specifically inhibit the activity of the 30 kD retinal ganglion neuronotrophic factor.  相似文献   

13.
This paper describes an automated apparatus combining Rosenfield's and Lalezari's antibody screening and identification basic technics. PVP bromelin and low ionic strength acid polybren channels are used; agglutinates are decanded; the remaining cells are hemolyzed and the optical density is then measured through a colorimeter and recorded on a chart; speed is of 40 samples an hour. This machine was also used for irregular antibody screening and identification. Sensitivity is shown to be equal to that of manual technics for ABO, Lewis, Lutheran as well as K, S, M, Kpb, Xga, U and Vel antibodies detection. Nevertheless, a much greater sensitivity is achieved (titers 3 to 10 times higher) than by manual technics for Rh, -k, S, Fya antibodies detection. Polybren channel is suitable for anti-Rh, Duffy, I and M (human detection; bromelin channel however, has a greater sensitivity for other specificities. Anti-M and anti-N sera from rabbits were shown to be non specific when using this machine. Over almost 15 000 sera tested, no antibody (detected by manual techniques) escaped the automated screening. This antibody detection machine was applied to compatibility tests prior to transfusion. (21 480 units were tested. aimed to be transfused to 5 611 patients). A third, PVP without bromelin, was set in parallel in order not to let escape any anti-M, even a weak one. The sera distributor was slaved to the cells distributor so that the whole procedure was automated. Furthermore, each serum was tested against red cells to be transfused, but also against the patient's own red cells to be transfused, but also against the patient's own red cells and against two selected red cells panels, so as to ensure irregular antibody detection at the same time. Using this machine, 3 to 4% of the cell samples were rejected, i.e. more than with usual techniques. All manually detected antibodies were identified, but also some others, which showed only weak reactions by classical techniques. Total results can be obtained within 20 to 30 minutes, which is quite rapid, compared to techniques using for example antiglobulin tests.  相似文献   

14.
15.
This study describes a RNA aptamer-based biochip with high affinity and specificity for C-reactive protein (CRP). CRP, which exists in concentrations of 1-3mg/l in the serum of healthy patients, has been identified as a reliable biomarker for inflammation and as a potential marker for sepsis and tissue necrosis. The CRP-specific aptamer was covalently immobilized with its 5'-end on ARChip Epoxy. The detection of bound CRP was carried out optically using labelled secondary antibody in a sandwich format. Assay conditions were optimized with respect to the CRP binding buffer (buffer system, pH and additives) and Ca(2+) concentration (10 mM). Moreover, two sandwich immunoassay formats were tested, the one using dye-labelled antibodies and the other with biotin-modified antibodies/Dy647-labelled streptavidin. In comparison with an antibody-based chip assay, the aptamer chip is superior in terms of CRP measuring range (10 microg/l to 100mg/l) in human serum whereas antibody-based chips result in superior data reproducibility (CV of 8-15%). In contrast to antibody chips, aptamer microarrays provide the unique potential of detecting CRP in serum samples of low risk patients (1-3mg/l) as well as high risk patients (>500 mg/l), furthermore elevated CRP levels (20-350 mg/l) with acceptable recovery (70-130%) by including only one serum sample dilution step (1:100) for the complete measuring range.  相似文献   

16.
Summary The effect of microwave antigen retrieval on the immunostaining of human duodenal endocrine cells in formaldehyde-fixed, paraffin-embedded material was investigated. The sections were immunostained by the avidin-biot in complex (ABC) and immunogold-silver autometallography (IGSS) methods with and without prior microwave treatment. Dilutions of up to 1:30 000 of the following antisera/antibodies were used: anti-chromogranin A, anti-chromogranin AB, anti-secretin, anti-gastrin, anti-gastric inhibitory polypeptide, anti-somatostatin and anti-serotonin. The detection threshold for all the antibodies was lower after antigen retrieval, and the primary antibody could be used in higher dilutions. The dilutions varied for different antibodies and were between two and ten times the optimal dilution without antigen retrieval. At extremely high dilutions of, or without, the primary antibody, non-specific staining of some lymphocytes and the mucus of some goblet cells was observed when the avidin method was applied, but not with the immunogold technique. This phenomenon was not observed when optimal dilution or a lower dilution was used. This seems to have been caused by the binding of the avidin-biotin complex to epitopes in these structures unmasked by microwave treatment when competition with specific binding sites was absent. This revised version was published online in November 2006 with corrections to the Cover Date.  相似文献   

17.
The mixed hemadsorption (MHA) reaction detects antibodies reactive with cell surface antigens by means of antiglobulin-coated indicator erythrocytes. We have developed a radioisotopic modification which employs sheep erythrocytes (SRBC) that have been prelabeled with technetium-99m (99mTc), a high specific acitivity metastable gamma-emitter of short half life. The 99mTc MHA reaction was performed on human and murine cells cultured in Micro-test II plated with six replicate wells per serum dilution. Antibody activity in species-specific xenoantisera and mono- and polyspecific alloantisera was detected in high titer. The sensitivity of 99mTc micro-mixed hemadsorption was 2 times that of the visual assessment of mixed hemadsorption, 100 to 200 times that of the 125-I-mixed antiglobulin reaction and 500 to 1000 times more sensitive than indirect immunofluorescence. The assay system was applied successfully to confirm the species of origin of a panel of previously karyotyped human and mouse cell lines. Our results indicate that the 99mTc micro-mixed hemadsorption method is a rapid, sensitive, quantitative test for the detection of cell surface antigens and membrane reactive antibodies.  相似文献   

18.
The enzyme-linked immunosorbent assay (ELISA) has been used for detection of antibodies against Mycoplasma pneumoniae. The results of ELISA and its sensitivity compared with other serological methods, such as complement fixation (CF), metabolic inhibition (MI), mycoplasmacidal test (MC), and radioimmunoprecipitation (RIP) are reported. ELISA and MC showed greater sensitivity than CF and MI, while RIP showed serum titer two- to 16-fold higher. ELISA was specific as determined using other human mycoplasma. A simplified method based on the determination of ELISA antibody end-point titer by a single serum dilution has been proposed. ELISA presented several advantages: sensitivity, rapidity, and low cost and, if adequately standardized, could become a reliable method for the serodiagnosis of M. pneumoniae infection.  相似文献   

19.
The susceptibility to lysis by antibody and complement was examined in four human cell lines. The cells were infected with herpes simplex virus type 1 and lysis was assessed by the 51Cr release test by using antibodies to herpes simplex virus and guinea pig serum as a source of complement. The four cell lines were found to differ in their susceptibility to lysis, although virus replication was readily demonstrated in the different cell lines. By indirect immunofluorescence, no differences in the expression of virus antigens at the surface of the cells could be found between the different cell lines. Treatment of cells with neuraminidase markedly enhanced the sensitivity of the cells which were relatively insensitive to lysis. The enhancement of susceptibiltiy to lysis by neuraminidase occurred if cells were treated before reaction of the cells with antibody and if the cells were reacted with antibody before treatment with the enzyme. No enhancement was observed when cells were reacted with antibody and complement before neuraminidase treatment. Neuraminidase treatment did not seem to enhance appreciably the quantity of antibody which reacted at the cell surface. The observations suggest that surface properties of certain cells render the cells resistant to lysis by antibody and complement and that the resistance to lysis can be abrogated by treating the cells with neuraminidase.  相似文献   

20.
[背景]副猪嗜血杆菌(Haemophilusparasuis,HPS)是猪革拉瑟氏病(Glasser's Disease)的病原体,抗生素治疗和疫苗接种对于防控该病效果不明显,建立快速、准确的抗体检测方法尤为重要.[目的]利用表达纯化的HPS转铁结合蛋白A(TbpA)建立检测HPS抗体的间接酶联免疫吸附试验(ELISA...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号