首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Correlative fluorescence light microscopy and electron microscopy allows the imaging of spatial distributions of specific biomolecules in the context of cellular ultrastructure. Recent development of super-resolution fluorescence microscopy allows the location of molecules to be determined with nanometer-scale spatial resolution. However, correlative super-resolution fluorescence microscopy and electron microscopy (EM) still remains challenging because the optimal specimen preparation and imaging conditions for super-resolution fluorescence microscopy and EM are often not compatible. Here, we have developed several experiment protocols for correlative stochastic optical reconstruction microscopy (STORM) and EM methods, both for un-embedded samples by applying EM-specific sample preparations after STORM imaging and for embedded and sectioned samples by optimizing the fluorescence under EM fixation, staining and embedding conditions. We demonstrated these methods using a variety of cellular targets.  相似文献   

2.
After terrorists attacked the United States in 2001, the appearance of letters and other objects containing powdery substances with unknown potentials for biological threat focused attention on the speed, sensitivity, and reliability of diagnostic methods. This study summarizes the abilities and limitations of real-time PCR, electron microscopy (EM), and virus isolation when used to detect potential bioweapons. In particular, we investigated the inhibitory influences of different common household products present in environmental specimens on PCR yield, EM detection, and virus isolation. We used vaccinia virus as a model for orthopoxviruses by spiking it into specimens. In the second part of the study, we describe modifications of diagnostic methods to overcome inhibitory effects. A variety of PCR amplification enhancers, DNA extraction protocols, and applications of internal controls were evaluated to improve diagnostic simplicity, speed, and reliability. As a result, we strongly recommend using at least two different frontline techniques in parallel, e.g., EM and PCR. A positive result obtained by any one of these techniques should be followed by a biological method to confirm the putative diagnosis. Confirmatory methods include virus isolation followed by an agent-specific immunofluorescence assay to confirm the presence of replication-competent particles.  相似文献   

3.
The utility of electron microscopy (EM) applied to fine needle aspiration (FNA) biopsy specimens was analyzed in order to determine the role and the diagnostic contribution of the EM examination. A rapid stain (Diff-Quik) was used to obtain a preliminary diagnostic impression and to assure the adequacy of the EM specimen for problematic cases. Our experience suggests that EM is being relied upon with greater frequency in the study of FNA specimens because it is an accurate and cost-effective diagnostic procedure. The use of a rapid interpretation (Diff-Quik stain) enhances the quality of the EM specimen and, as in surgical pathology, the EM examination increases the accuracy and specificity of the FNA biopsy diagnosis.  相似文献   

4.
Electron microscopy(EM) should be used in the front line for detection of agents in emergencies and bioterrorism,on accounts of its speed and accuracy.However,the number of EM diagnostic laboratories has decreased considerably and an increasing number of people encounter difficulties with EM results.Therefore,the research on viral structure and morphology has become important in EM diagnostic practice.EM has several technological advantages,and should be a fundamental tool in clinical diagnosis of viruses,particularly when agents are unknown or unsuspected.In this article,we review the historical contribution of EM to virology,and its use in virus differentiation,localization of specific virus antigens,virus-cell interaction,and viral morphogenesis.It is essential that EM investigations are based on clinical and comprehensive pathogenesis data from light or confocal microscopy.Furthermore,avoidance of artifacts or false results is necessary to exploit fully the advantages while minimizing its limitations.  相似文献   

5.
成人腹泻轮状病毒ELISA方法的建立和应用   总被引:1,自引:0,他引:1  
本文通过特异性试验、阻断试验、交叉试验、敏感度试验和重复性试验,建立了成人腹泻轮状病毒一酶联免疫吸附试验法(ADRV—ELISA)。应用此法检测了全国20多个省区202份病人腹泻标本,检出率为91%。采用本ELISA、核酸电泳、电镜三种方法对48份病人腹泻标本进行了双盲法检测比较,结果三种方法的阳性检出率分别为100%、85.4%、56.25%(P<0.05)。实验结果表明,本ELISA应用于检测成人腹泻轮状病毒(ADRV),具有敏感度高。特异性强等优点。  相似文献   

6.
In the past, ultrastructural studies on chromosome morphology have been carried out using light microscopy, scanning electron microscopy and transmission electron microscopy of whole mounted or sectioned samples. Until now, however, it has not been possible to use all of these techniques on the same specimen. In this paper we describe a specimen preparation method that allows one to study the same chromosomes by transmission, scanning-transmission and scanning electron microscopy, as well as by standard light microscopy and confocal microscopy. Chromosome plates are obtained on a carbon coated glass slide. The carbon film carrying the chromosomes is then transferred to electron microscopy grids, subjected to various treatments and observed. The results show a consistent morphological correspondence between the different methods. This method could be very useful and important because it makes possible a direct comparison between the various techniques used in chromosome studies such as banding, in situ hybridization, fluorescent probe localization, ultrastructural analysis, and colloidal gold cytochemical reactionsAbbreviations CLSM confocal laser scanning microscope - EM electron microscopy - kV kilovolt(s) - LM light microscope - SEM scanning electron microscope - STEM scanning-transmission electron microscope - TEM transmission electron microscope  相似文献   

7.
Liquid-electron microscopy (EM), the room temperature correlate to cryo-EM, is an exciting new technique delivering real-time data of dynamic reactions in solution. Here, we explain how liquid-EM gained popularity in recent years by examining key experiments conducted on viral assemblies and host–pathogen interactions. We describe developing workflows for specimen preparation, data collection, and computing processes that led to the first high-resolution virus structures in a liquid environment. Equally important, we review why liquid-electron tomography may become the next big thing in biomedical research due to its ability to monitor live viruses entering cells within seconds. Taken together, we pose the idea that liquid-EM can serve as a dynamic complement to current cryo-EM methods, inspiring the “real-time revolution” in nanoscale imaging.  相似文献   

8.
Single particle electron microscopy (EM) is an increasingly important tool for the structural analysis of macromolecular complexes. The main advantage of the technique over other methods is that it is not necessary to precede the analysis with the growth of crystals of the sample. This advantage is particularly important for membrane proteins and large protein complexes where generating crystals is often the main barrier to structure determination. Therefore, single particle EM can be employed with great utility in the study of large membrane protein complexes. Although the construction of atomic resolution models by single particle EM is possible in theory, currently the highest resolution maps are still limited to approximately 7-10A resolution and 15-30 A resolution is more typical. However, by combining single particle EM maps with high-resolution models of subunits or subcomplexes from X-ray crystallography and NMR spectroscopy it is possible to build up an atomic model of a macromolecular assembly. Image analysis procedures are almost identical for micrographs of soluble protein complexes and detergent solubilized membrane protein complexes. However, electron microscopists attempting to prepare specimens of a membrane protein complex for imaging may find that these complexes require different handling than soluble protein complexes. This paper seeks to explain how high-quality specimen grids of membrane protein complexes may be prepared to allow for the determination of their structure by EM and image analysis.  相似文献   

9.
Nucleocytoplasmic large DNA viruses are a steadily growing group of viruses that infect a wide range of hosts and are characterized by large particle dimensions and genome sizes. Understanding how they enter into the host cell and deliver their genome in the cytoplasm is therefore particularly intriguing. Here, we review the current knowledge on the entry of two of the best-characterized nucleocytoplasmic large DNA viruses: the poxvirus Vaccinia virus (VACV) and the giant virus Mimivirus. While previous studies on VACV had proposed both direct fusion at the plasma membrane and endocytosis as entry routes, more recent biochemical and morphological data argue for macropinocytosis as well. Notably, direct imaging by electron microscopy (EM) also supported the existence of parallel ways of entry for VACV. Instead, all the giant viruses studied so far only enter cells by phagocytosis as observed by EM, and we discuss the mechanisms for opening of the particle, fusion of the viral and phagosomal membranes and genome delivery via a unique portal, specific for each giant virus. VACV core uncoating, in contrast, remains a morphologically ill-defined process. We argue that correlated light and electron microscopy methods are required to study VACV entry and uncoating in a direct and systematic manner. Such EM studies should also address whether entry of single particles and viral aggregates is different and thus provide an explanation for the different modes of entry described in the literature.  相似文献   

10.
The replication of HIV‐1, like that of all viruses, is intimately connected with cellular structures and pathways. For many years, bulk biochemical and cell biological methods were the main approaches employed to investigate interactions between HIV‐1 and its host cell. However, during the past decade advancements in fluorescence imaging technologies opened new possibilities for the direct visualization of individual steps occurring throughout the viral replication cycle. Electron microscopy (EM) methods, which have traditionally been employed for the study of viruses, are complemented by fluorescence microscopy (FM) techniques that allow us to follow the dynamics of virus–cell interaction. Subdiffraction fluorescence microscopy, as well as correlative EM/FM approaches, are narrowing the fundamental gap between the high structural resolution provided by EM and the high temporal resolution and throughput accomplished by FM. The application of modern microscopy to the study of HIV‐1–host cell interactions has provided insights into the biology of the virus which could not easily, or not at all, have been gained by other methods. Here, we review how modern fluorescence imaging techniques enhanced our knowledge of the dynamic and structural changes involved in HIV‐1 particle formation.   相似文献   

11.
In microbiology, and in particular in virus research, electron microscopy (EM) is an important tool, offering a broad approach for investigating viral structure throughout their intracellular and extracellular life cycles. Currently, molecular tools and rapid developments in advanced light microscopy dominate the field and supply an enormous amount of information concerning virus biology. In recent years, numerous fascinating high-resolution EM structures obtained by single-particle electron cryo microscopy (cryo-EM) were revealed for viral particles that possess icosahedral symmetry. However, no comprehensive three-dimensional analysis of complex viruses or viruses within cells has yet been achieved using EM. Recent developments in electron cryo-tomography render this a proficient tool for the analysis of complex viruses and viruses within cells in greater detail.  相似文献   

12.
We used low-temperature, high-resolution scanning electron microscopy (cryo-HRSEM) to visualize surface structures on individual reovirus particles. Both intact virions and two forms of subvirion particles—infectious subvirion particles and cores—were examined, and despite some distortion of particles during specimen preparation and viewing in the microscope, the images obtained by cryo-HRSEM exhibited a level of interpretable detail not routinely achieved by other methods without image averaging. Cryo-HRSEM images of discrete reovirus particles were used to characterize and confirm features of the outer protein capsid of this virus by comparison with image reconstructions previously derived from cryotransmission electron microscopy. Distinct surface features attributable to each of the four outer-capsid proteins were identified. In addition, cryo-HRSEM images confirmed that significant changes occur on the surfaces of individual reovirus particles during disassembly and entry of cells and that the reovirus outer capsid is organized as a left-handed T=13 icosahedron. Several unique capabilities and potential uses suggest that cryo-HRSEM has a place alongside other, more established methods for molecular characterizations of virus particles.  相似文献   

13.
Virus structures are megadalton nucleoprotein complexes with an exceptional variety of protein-protein and protein-nucleic-acid interactions. Three-dimensional crystal structures of over 70 virus capsids, from more than 20 families and 30 different genera of viruses, have been solved to near-atomic resolution. The enormous amount of information contained in these structures is difficult to access, even for scientists trained in structural biology. Virus Particle Explorer (VIPER) is a web-based catalogue of structural information that describes the icosahedral virus particles. In addition to high-resolution crystal structures, VIPER has expanded to include virus structures obtained by cryo-electron microscopy (EM) techniques. The VIPER database is a powerful resource for virologists, microbiologists, virus crystallographers and EM researchers. This review describes how to use VIPER, using several examples to show the power of this resource for research and educational purposes.  相似文献   

14.
Viruses have unique morphology and are therefore good candidates for negative staining. Negative staining with phosphotungstic acid (PTA) or uranyl acetate has facilitated the detection of many viruses in clinical specimens. Enhancement procedures have included the use of centrifugation and agar diffusion for concentrating virus particles, the use of solid phase capture reagents to trap virus particles and the use of secondary antibodies and electron dense markers to help visualize them. Techniques currently in use and employing negative staining include direct EM, immune electron microscopy (IEM), solid phase immune electron microscopy (SPIEM), colloidal gold-labeled protein A (PAG), solid phase IEM employing a second decorator antibody (SPIEMDAT), and solid phase IEM using colloided gold-labeled secondary antibodies (SPEIMDAGT). IEM methods assist with the detection of small viruses or viruses present in low numbers while PAG offers increased sensitivity over direct EM and IEM. In our experience the serum-in-agar (SIA) method is the most sensitive of the PAG IEM techniques for detection of rotavirus particles in clinical specimens. SPIEMDAT enhances the detection of small viruses which are often missed by other techniques due to background staining in specimens. SPEIMDAGT employing colloidal gold-labeled secondary antibody has increased sensitivity and offers the advantage of detecting viral antigen when whole virus particles are not visible. IEM techniques have recently been used for typing viruses using either monospecific antisera or monoclonal antibodies and colloidal gold-labeled secondary antibody.  相似文献   

15.
Electron microscopy (EM) allows fast visualization of viruses in a wide range of clinical specimens. Viruses are grouped into families based on their morphology. Viruses from various families look distinctly and these morphological variances are the basis for identification of viruses by EM. The identification to the family level is often sufficient for the clinician or recognition of an unknown infectious agent. Diagnostic EM has two advantages over enzyme-linked immunosorbent assay and nucleic acid amplification tests. After a simple and fast negative staining, EM allows fast morphological identification and differential diagnosis of infectious agents contained in the specimen without the need for special considerations and/or reagents. Nevertheless, EM has the disadvantage of being unsuitable as a screening method.  相似文献   

16.
McDonald KL  Auer M 《BioTechniques》2006,41(2):137, 139, 141 passim
Structural cell biology, which we define as electron microscopic analysis of intact cells, suffered a loss of interest and activity following the advances in light microscopy beginning in the 1990s. Interestingly, it is the wealth of detailed observation in the light microscope that is one of the driving forces for the current renewed interest in electron microscopy (EM). A great many cellular details are simply beyond the resolving power of the light microscope. In this article, we describe how electron microscopists are responding to the demands for better preservation of cells and for ways to view cell ultrastructure in three dimensions at high resolution. We discuss how low temperature methods, especially high-pressure freezing and freeze substitution, reduce the artifacts of conventional EM specimen preparation. We also give a brief introduction to cellular electron tomography, a powerful analytical method that can give near-atomic resolution of cell ultrastructure in three-dimensional (3-D) models.  相似文献   

17.
The outcome of three-dimensional (3D) reconstructions in single particle electron microscopy (EM) depends on a number of parameters. We have used the well-characterized structure of the transferrin (Tf)-transferrin receptor (TfR) complex to study how specimen preparation techniques influence the outcome of single particle EM reconstructions. The Tf-TfR complex is small (290kDa) and of low symmetry (2-fold). Angular reconstitution from images of vitrified specimens does not reliably converge on the correct structure. Random conical tilt reconstructions from negatively stained specimens are reliable, but show variable degrees of artifacts depending on the negative staining protocol. Alignment of class averages from vitrified specimens to a 3D negative stain reference model using FREALIGN largely eliminated artifacts in the resulting 3D maps, but not completely. Our results stress the need for critical evaluation of structures determined by single particle EM.  相似文献   

18.
Single particle electron microscopy (EM), of both negative stained or frozen hydrated biological samples, has become a versatile tool in structural biology 1. In recent years, this method has achieved great success in studying structures of proteins and macromolecular complexes 2, 3. Compared with electron cryomicroscopy (cryoEM), in which frozen hydrated protein samples are embedded in a thin layer of vitreous ice 4, negative staining is a simpler sample preparation method in which protein samples are embedded in a thin layer of dried heavy metal salt to increase specimen contrast 5. The enhanced contrast of negative stain EM allows examination of relatively small biological samples. In addition to determining three-dimensional (3D) structure of purified proteins or protein complexes 6, this method can be used for much broader purposes. For example, negative stain EM can be easily used to visualize purified protein samples, obtaining information such as homogeneity/heterogeneity of the sample, formation of protein complexes or large assemblies, or simply to evaluate the quality of a protein preparation.In this video article, we present a complete protocol for using an EM to observe negatively stained protein sample, from preparing carbon coated grids for negative stain EM to acquiring images of negatively stained sample in an electron microscope operated at 120kV accelerating voltage. These protocols have been used in our laboratory routinely and can be easily followed by novice users.  相似文献   

19.
The recently developed correlative super-resolution fluorescence microscopy (SRM) and electron microscopy (EM) is a hybrid technique that simultaneously obtains the spatial locations of specific molecules with SRM and the context of the cellular ultrastructure by EM. Although the combination of SRM and EM remains challenging owing to the incompatibility of samples prepared for these techniques, the increasing research attention on these methods has led to drastic improvements in their performances and resulted in wide applications. Here, we review the development of correlative SRM and EM (sCLEM) with a focus on the correlation of EM with different SRM techniques. We discuss the limitations of the integration of these two microscopy techniques and how these challenges can be addressed to improve the quality of correlative images. Finally, we address possible future improvements and advances in the continued development and wide application of sCLEM approaches.  相似文献   

20.
《Biophysical journal》2020,118(3):708-719
Blotting has been the standard technique for preparing aqueous samples for single-particle electron cryo-microscopy for over three decades. This technique removes the excess solution from a transmission electron microscope grid by pressing absorbent filter paper against the specimen before vitrification. However, this standard technique produces vitreous ice with inconsistent thickness from specimen to specimen and from region to region within the same specimen, the reasons for which are not understood. Here, high-speed interference contrast microscopy is used to demonstrate that the irregular pattern of fibers in the filter paper imposes tortuous, highly variable boundaries during the removal of excess liquid from a flat, hydrophilic surface. As a result, aqueous films of nonuniform thickness are formed while the filter paper is pressed against the substrate. This pattern of nonuniform liquid thickness changes again after the filter paper is pulled away, but the thickness still does not become completely uniform. We suggest that similar topographical features of the liquid film are produced during the standard technique used to blot EM grids and that these manifest in nonuniform ice after vitrification. These observations suggest that alternative thinning techniques, which do not rely on direct contact between the filter paper and the grid, may result in more repeatable and uniform sample thicknesses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号