首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
双水相体系逆流色谱技术结合了逆流色谱的高效率、高制备量以及双水相体系适于蛋白质分离的特点,因此在蛋白质的分离方面具有独特的应用价值。本文综述了近年来基于正交轴逆流色谱仪器的双水相体系逆流色谱技术在多种蛋白质分离中的应用。并对一些新兴的蛋白质逆流色谱分离技术及新型逆流色谱柱分离系统进行了介绍。  相似文献   

2.
A method which involves the combination of pH-zone-refining counter-current chromatography (pH-zone-refining CCC) and conventional high-speed counter-current chromatography (HSCCC) was established for the preparative separation of alkaloids from the crude extracts of Stephania kwangsiensis. pH-zone-refining CCC was first performed with the solvent system composed of n-hexane-ethyl acetate-methanol-water (3:7:1:9, v/v), where triethylamine (10 mM) was added to the upper organic stationary phase as a retainer and hydrochloric acid (5 mM) to the aqueous mobile phase as an eluter. From 2.0 g of crude extract, 370 mg of sinoacutine and 600 mg of a mixture of three other alkaloids were obtained. Then, the mixture was further separated by conventional HSCCC with the solvent system composed of n-hexane-ethyl acetate-methanol-water (7:3:6:4, v/v), yielding 42 mg of (-)-crebanine, 50 mg of (-)-stephanine and 30 mg of l-romerine from 150 mg mixture of three other alkaloids, respectively. The purities of the four compounds were all over 98% as determined by HPLC, and the chemical structures of the four compounds were confirmed by positive ESI-MS and (1)H NMR data. Results of the present study successfully indicated that this method was efficient for the preparative separation of alkaloids from natural plants.  相似文献   

3.
Biosynthesis of polyketide antibiotics, such as erythromycin A (EA), can result in the formation of analogues of the main compound that are chemically and structurally extremely similar. The large-scale purification of these antibiotics by conventional high-performance liquid chromatography (HPLC) can be prohibitively expensive due to the large volume of both solvent and adsorbent required. This study examines the feasibility of using a novel pilot-scale countercurrent chromatography (CCC) machine as an alternative to HPLC. CCC is a low-pressure (typically <4000 kN m(-2)) liquid-liquid chromatographic technique that allows the separation of solutes on the basis of their partitioning between two immiscible liquid phases. The effects of mobile phase flow rate, column rotational speed, and sample injection volume on the attainable yield and purity of EA were investigated. Our results show that, at a mobile phase flow rate of 40 mL min(-1), a rotational speed of 1200 rpm, and an injection volume of 100 mL (10 g total erythromycin), EA could be satisfactorily fractionated with a purity of approximately 92% (w/w) and a recovery yield of approximately 100% (w/w). The total solute throughput was estimated to be 0.41 kg day(-1). More importantly, we demonstrated simple and predictive linear scale-up of the CCC separation based on data obtained from a single laboratory-scale CCC chromatogram, and verified this experimentally. The retention time and peak width of the target compound at the pilot scale could be predicted to within 4% for operation at a range of mobile-phase flow rates and injection volumes. This predictable nature of CCC separations, unlike HPLC methods, can greatly reduce process development times and enable a complete process-scale operating scenario to be planned.  相似文献   

4.
The first straightforward lipase-catalyzed enantioselective access to enantiomerically enriched tiaprofenic acid as a versatile method in chiral separation of racemates is demonstrated. The latter was directly monitored by enantioselective HPLC using a 3,5-dimethylphenylcarbamate derivative of cellulose-based chiral stationary phase namely Chiralpak IB (the immobilized version of Chiralcel OD). Non-standard HPLC organic solvents were used as diluent to dissolve the "difficult to dissolve" enzyme substrate (the acid) and as eluent for the simultaneous enantioselective HPLC baseline separation of both substrate and product in one run without any further derivatization. The existence of a non-standard HPLC organic solvent (e.g., methyl tert-butyl ether) in the mobile phase composition is mandatory to accomplish the simultaneous enantioselective HPLC baseline separation of both substrate and product.  相似文献   

5.
Biomolecules are often purified via solvent gradient batch chromatography. Typically suitable smooth linear solvent gradients are applied to obtain the separation between the desired component and hundreds of impurities. The desired product is usually intermediate between weakly and strongly adsorbing impurities, and therefore a central cut is required to get the desired pure product. The stationary phases used for preparative and industrial separations have a low efficiency due to strong axial dispersion and strong mass transfer resistances. Therefore a satisfactory purification often cannot be achieved in a single chromatographic step. For large scale productions and for very valuable molecules, countercurrent operation such as the well known SMB process, is needed in order to increase separation efficiency, yield and productivity. In this work a novel multicolumn solvent gradient purification process (MCSGP-process) is introduced, which combines two chromatographic separation techniques, which are solvent gradient batch and continuous countercurrent SMB. The process consists of several chromatographic columns, which are switched in position opposite to the flow direction. Most of the columns are equipped with a gradient pump to adjust the modifier concentration at the column inlet. Some columns are interconnected, so that non pure product streams are internally, countercurrently recycled. Other columns are short circuited and operate in batch mode. As a working example the purification of an industrial stream containing 46% of the hormone Calcitonin is considered. It is found that for the required purity the MCSGP unit achieves a yield close to 100% compared to a maximum value of a single column batch chromatography of 66%.  相似文献   

6.
The production of plant terpenoids through biotransformation has undoubtedly become one of the research hotspots, and the continuous upgrading of the corresponding downstream technology is also particularly important. Downstream technology is the indispensable technical channel for the industrialization of plant terpenoids. How to efficiently separate high‐purity products from complex microbial fermentation broths or enzyme‐catalyzed reactions to achieve high separation rates, high returns and environmental friendliness has become the focus of research in recent years. This review mainly introduces the common separation methods of plant terpenoids based on biotransformation from the perspectives of engineering strain construction, unit separation technology, product properties and added value. Then, further attention was paid to the application prospects of intelligent cell factories and control in the separation of plant terpenoids. Finally, some current challenges and prospects are proposed, which provide possible directions and guidance for the separation and purification of terpenoids and even industrialization.  相似文献   

7.
应用高速逆流色谱分离桑枝酚类成分   总被引:1,自引:0,他引:1  
建立了高速逆流色谱(HsCCC)分离制备高纯度的桑枝酚类成分的新方法.分离条件如下:溶剂系统为正己烷-乙酸乙酯-甲醇冰(1∶1∶1∶2,v/v),上相为固定相,下相为流动相;流速2.0 mL/min;转速900rpm;进样量75 mg.收集得到三个高纯度化合物,经HPLC、MS、1H和13C NMR等分别鉴定为反式氧化白藜芦醇(25.2mg),反式白藜芦醇(7.4 mg)和桑辛素M(29.1 mg).高速逆流色谱可以高效分离桑枝成分,方法简便,技术可行,优于传统的柱色谱法.  相似文献   

8.
A normal phase HPLC system has been developed which is applicable to all of the steroid separations involved in the assay of steroid 17 alpha-hydroxylase (EC 1.14.99.9) and C17-20 lyase activities, in both the delta 4 (progesterone) and delta 5 (pregnenolone) pathways. A hexane-tetrahydrofuran (THF) gradient system is used with silica stationary phase and a flow cell radioactivity detector having a high efficiency for tritium. Folch extraction produces uniform extraction of substrates and products from the microsomal incubates, and this uniformity is maintained through HPLC separation and measurement. The hexane-THF mobile phase is convenient for product isolation and substrate purification and should be adaptable to other steroid separations. The system is especially useful for steroid enzyme assays utilizing radiolabeled substrates, since internal standards are not required for measuring recoveries of substrates and products.  相似文献   

9.
Counter-current chromatography (CCC) is a low pressure, liquid–liquid chromatographic technique which has proven to be a powerful purification tool for the high-resolution fractionation of a variety of active pharmaceutical compounds. The successful integration of CCC into either existing or new manufacturing processes requires the predictable purification of target compounds from crude, fermentation-derived, feed streams. This work examines the feasibility of CCC for the purification of fermentation-derived erythromycin A (EA) from its structurally and chemically similar analogues. At the laboratory scale, the effect of feed pre-treatment using either clarified, forward extracted (butyl acetate) or back extracted broth on EA separation was investigated. This defined the degree of impurity removal required, i.e. back extracted broth, to ensure a reproducible elution profile of EA during CCC. Optimisation and scale-up of the separation studied the effects of mobile phase flow (2–40 mlmin–1) and solute loading (0.1–10 g) on the attainable EA purity and yield. The results in all cases demonstrated a high attainable EA purity (>97% w/w) with throughputs up to 0.33 kgday–1. Secondly, a predictive scale-up model was applied demonstrating, that from knowledge of the solute distribution ratio of EA (KEA) at the laboratory scale, the EA elution time at the pilot scale could be predicted to within 3–10%, depending upon the solute injection volume. In addition, this study has evaluated a fractionation diagram approach to visually determine the effects of key operational variables on separation performance. This resulted in accurate fraction cut-point determination for a required degree of product purity and yield. Overall, the results show CCC to be a predictable and scaleable separation technique capable of handling real feed streams.  相似文献   

10.
The method uses a coiled column which slowly rotates about its axis under a gravitational field. When the column filled with the stationary phase is eluted with the mobile phase in the proper direction, nearly half of the stationary phase is retained although constantly mixed with the mobile phase. Consequently, those solutes introduced are subjected to an efficient partition process and are separated according to their relative partition coefficients. Optimum operational conditions are investigated with respect to column angle, rotational speed, and flow rate for the separation of peptides using a low interfacial tension n-BuOH phase system. The horizontal column position produces a segmental flow pattern of the aqueous phase, resulting in the highest resolution, whereas the rotation sharply increases the effciency from 0 to 10 rpm. Although the highest resolution is obtained by a slow flow rate, the time required for yielding one theoretical plate is minimized by a faster flow to less than 1 min per theoretical plate.  相似文献   

11.
The chromatographic separation of an unstable protein is often a challenge to the scientist working in the field of life sciences. Especially for the purification of sensitive enzymes, making use of conventional chromatographic techniques is difficult and frequently results in a complete loss of biological activity of the target protein. This report summarizes some general strategies that may help to keep unstable proteins in their native conformation during the rather harsh conditions of a purification procedure. In this context, a recently developed hollow fiber membrane module, suitable for performing on-line dialysis, is introduced and examples of its application to liquid column chromatography are given. Many innovative separation techniques, characterized by dramatic improvements in both performance and separation time, have recently been developed. Since the chromatographic separation of unstable proteins requires the use of modern state-of-the-art equipment and technology, emphasis is given to newly developed separation techniques such as expanded bed adsorption, perfusion chromatography, protein free flow electrophoresis and the use of tentacle gels. In addition, examples of recently published purifications of unstable proteins are discussed with respect to strategies ensuring the preservation of the native protein structure during chromatographic separation.  相似文献   

12.
采用高速逆流色谱(HSCCC)技术从蛹虫草子实体粗提物中分离制备高纯度虫草素和N6-(2-羟乙基)-腺苷。利用高效液相色谱(HPLC)测定目标产物在溶剂体系中的分配系数,优化HSCCC分离虫草素和N6-(2-羟乙基)-腺苷的溶剂体系,确定了以乙酸乙酯-正丁醇-1.5%氨水(1:4:5,V/V/V)为HSCCC的两相溶剂体系,并运用此溶剂体系,上相为固定相,下相为流动相,主机转速850r/min,流动相流速为1.5mL/min,检测波长为254nm条件下进行分离制备,在250min内从200mg蛹虫草子实体粗提物中一步分离得到10.8mg纯度99%的虫草素和6.1mg 纯度98%的N6-(2-羟乙基)-腺苷。该方法简便、快速,为虫草素和N6-(2-羟乙基)-腺苷的大量制备建立了基础。  相似文献   

13.
Peptide stereoisomer analysis is of importance for quality control of therapeutic peptides, the analysis of stereochemical integrity of bioactive peptides in food, and the elucidation of the stereochemistry of peptides from a natural chiral pool which often contains one or more D‐amino acid residues. In this work, a series of model peptide stereoisomers (enantiomers and diastereomers) were analyzed on a zwitterionic ion‐exchanger chiral stationary phase (Chiralpak ZWIX(+) 5 µm), in order to investigate the retention and separation performance for such compounds on this chiral stationary phase and elucidate its utility for this purpose. The goal of the study focused on 1) investigations of the effects of the sample matrix used to dissolve the peptide samples; 2) optimization of the mobile phase (enabling deriving information on factors of relevance for retention and separation); and 3) derivation of structure–selectivity relationships. It turned out that small di‐ and tripeptides can be well resolved under optimized conditions, typically with resolutions larger than 1.5. The optimized mobile phase often consisted of methanol–tetrahydrofuran–water (49:49:2; v/v/v) with 25 mM formic acid and 12.5 mM diethylamine. This work proposes some guidance on which mobile phases can be most efficiently used for peptide stereoisomer separations on Chiralpak ZWIX. Chirality 28:5–16, 2016. © 2015 Wiley Periodicals, Inc.  相似文献   

14.
The purification of molecules from recombinant cells may be strongly influenced by the molecular biology of gene isolation and expression. At the beginning of the process there may be a demand for information on the minute amounts of proteins and thus for ever increasingly sensitive techniques. Purification of recombinant proteins can differ from conventional purifications in several ways, depending on the solubility of the protein, occurrence in inclusion bodies, creation of fusion proteins with tags that enable simpler purification. Sometimes a (re)naturation step is required to get a bioactive protein. On the other hand, the techniques used in separation are essentially the same as for purification from the natural source and environment.  相似文献   

15.
Hydrophobic interaction chromatography (HIC) is commonly used as a polishing step in monoclonal antibody purification processes. HIC offers an orthogonal selectivity to ion exchange chromatography and can be an effective step for aggregate clearance and host cell protein reduction. HIC, however, suffers from the limitation of use of high concentrations of kosmotropic salts to achieve the desired separation. These salts often pose a disposal concern in manufacturing facilities and at times can cause precipitation of the product. Here, we report an unconventional way of operating HIC in the flowthrough (FT) mode with no kosmotropic salt in the mobile phase. A very hydrophobic resin is selected as the stationary phase and the pH of the mobile phase is modulated to achieve the required selectivity. Under the pH conditions tested (pH 6.0 and below), antibodies typically become positively charged, which has an effect on its polarity and overall surface hydrophobicity. Optimum pH conditions were chosen under which the antibody product of interest flowed through while impurities such as aggregates and host cell proteins bound to the column. This strategy was tested with a panel of antibodies with varying pI and surface hydrophobicity. Performance was comparable to that observed using conventional HIC conditions with high salt.  相似文献   

16.
Ghanem A  Al-Humaidi E 《Chirality》2007,19(6):477-484
The chiral recognition ability and solvent versatility of a new chiral stationary phase containing amylose 3,5-dimethylphenylcarabamate immobilized onto silica gel (CHIRALPAK IA) is investigated. Thus, the direct enantioselective separation of a set of racemic N-alkylated barbiturates and 3-alkylated analogs of thalidomide was conducted using different nonstandard solvents as eluent and diluent, respectively in high-performance liquid chromatography (HPLC). The separation, resolution, and elution order of the investigated compounds were compared on both immobilized and coated amylose tris(3,5-dimethylphenylcarbamate) chiral stationary phases (Chiralpak IA and Chiralpak AD, respectively) using a mixture of n-hexane/2-propanol (90:10 v/v) as mobile phase with different flow-rates and fixed UV detection at 254 nm. The effect of the immobilization of the amylose tris(3,5-dimethylphenylcarbamate) chiral stationary phase on silica (Chiralpak IA) on the chiral recognition ability was noted as the bonded phase (Chiralpak IA) was superior in chiral recognition and possesses a higher resolving power in most of the reported cases than the coated one (Chiralpak AD). A few racemates were not or poorly resolved on the immobilized Chiralpak IA or the coated Chiralpak AD when using standard solvents were most efficiently resolved on the immobilized Chiralpak IA upon using nonstandard solvents. Furthermore, the immobilized phase withstands the nonstandard (prohibited) HPLC solvents such as dichloromethane, ethyl acetate, tetrahydrofuran, methyl-tert-butyl ether, and others when used as eluents or as a dissolving agent for the analyte itself. The direct analysis of a real sample extracted from plasma using DCM on Chiralpak IA is also shown.  相似文献   

17.
There is a demand of novel high resolution separation media for separation of complex mixtures, particularly biological samples. One of the most flexible techniques for development of new separation media currently is synthesis of the continuous bed (monolithic) stationary phases. In this study the capillary format gradient stationary phases were formed using continuous bed (monolith) polymerization in situ. Different reversed-phase stationary phase gradients were tailored and their resolution using capillary liquid chromatography and capillary electrochromatography at isocratic mobile phase conditions was evaluated. It is demonstrated, that efficiency and resolution of the gradient stationary phases can be substantially increased comparing to the common (isotropic) stationary phases. The proposed formation approach of the gradient stationary phase is reproducible and compatible with the capillary format or microchip format separations. It can be easily automated for the separation optimizations or mass production of the capillary columns or chips.  相似文献   

18.
There is a demand of novel high resolution separation media for separation of complex mixtures, particularly biological samples. One of the most flexible techniques for development of new separation media currently is synthesis of the continuous bed (monolithic) stationary phases. In this study the capillary format gradient stationary phases were formed using continuous bed (monolith) polymerization in situ. Different reversed-phase stationary phase gradients were tailored and their resolution using capillary liquid chromatography and capillary electrochromatography at isocratic mobile phase conditions was evaluated. It is demonstrated, that efficiency and resolution of the gradient stationary phases can be substantially increased comparing to the common (isotropic) stationary phases. The proposed formation approach of the gradient stationary phase is reproducible and compatible with the capillary format or microchip format separations. It can be easily automated for the separation optimizations or mass production of the capillary columns or chips.  相似文献   

19.
A high yield of betulinic acid (up to 17% from the ethanolic extract) was found in the leaves of Eugenia florida collected in south-eastern Brazil, making this species a potential commercial source of the title compound. Extracts of E. florida were subjected to solvent partition, and rapid high-speed counter-current chromatography (HSCCC) was applied to the semi-crude extracts to afford betulinic acid in high purity. The mobile and stationary phases were derived from the two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (10:5:2.5:1). The developing solvent system (stationary and mobile phases) for optimum HSCCC separation was chosen by dissolving the fraction to be chromatographed in the proposed solvent mixture and determining the amount of betulinic acid in each phase by densitometric TLC. Purified betulinic acid was characterized by 13C-NMR, GC-MS and co-injection of its methyl ester with standards in GC-FID. The HSCCC technique is commonly employed to isolate triterpene glycosides, but is applied in this study to an aglycone.  相似文献   

20.
Enantiomeric separations of six amino‐acid derivatives have been studied using packed‐column supercritical fluid chromatography with two polysaccharide‐based enantioselective stationary phases: cellulose tris(3,5‐dimethylphenylcarbamate) and cellulose tris(3‐chloro‐4‐methylphenylcarbamate) (Lux Cellulose‐1 and ‐2). The effect of analyte structure on retention and separation was studied. Varied mobile phase compositions were investigated: alcohol modifier percentage was increased from 3 to 40% but smaller amounts were most effective in separating these compounds. Besides, ethanol was preferred to methanol or isopropanol as it proved to be a good compromise to achieve sufficient resolution in a reasonable analysis time. Moreover, a carbon dioxide‐ethanol mixture allows performing analyses in safe and green conditions. The effect of temperature at constant mobile phase composition was explored between 10 and 40°C. In most cases, increasing the temperature improved the chiral separation, up to an optimum temperature. The results are discussed in line with the structure variation of the racemic derivatives analyzed and the two columns are compared. The two columns were shown to provide complementary selectivities for the investigated solutes: whereas Lux 1 provided separation for five of the six racemates, Lux 2 could resolve the last racemic mixture. Finally, optimized conditions of separation are defined. Chirality, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号