首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 928 毫秒
1.
Cardiac morphology and function assessment by magnetic resonance imaging is of increasing interest for a variety of mouse models in pre-clinical cardiac research, such as myocardial infarction models or myocardial injury/remodeling in genetically or pharmacologically induced hypertension. Signal-to-noise ratio (SNR) constraints, however, limit image quality and blood myocardium delineation, which crucially depend on high spatial resolution. Significant gains in SNR with a cryogenically cooled RF probe have been shown for mouse brain MRI, yet the potential of applying cryogenic RF coils for cardiac MR (CMR) in mice is, as of yet, untapped. This study examines the feasibility and potential benefits of CMR in mice employing a 400 MHz cryogenic RF surface coil, compared with a conventional mouse heart coil array operating at room temperature. The cryogenic RF coil affords SNR gains of 3.0 to 5.0 versus the conventional approach and hence enables an enhanced spatial resolution. This markedly improved image quality - by better deliniation of myocardial borders and enhanced depiction of papillary muscles and trabeculae - and facilitated a more accurate cardiac chamber quantification, due to reduced intraobserver variability. In summary the use of a cryogenically cooled RF probe represents a valuable means of enhancing the capabilities of CMR of mice.  相似文献   

2.
Darrasse L  Ginefri JC 《Biochimie》2003,85(9):915-937
Since discovery of high-temperature superconductive (HTS) ceramics by Bednorz and Muller in 1986, there has been an accelerated development of cold technologies in industry, including the domain of NMR detection. The purpose of this paper is to fix ideas about the stage that cryogenic radio frequency (RF) probe techniques have reached in biomedical magnetic resonance imaging (MRI). Readers confronted to the literature about this emerging topic have to understand a large range of motivations with somewhat unclearly defined technical limitations and actual outlets. An overview of sensitivity issues in the general context of biomedical MRI is provided here and the contribution of RF coil techniques to recent advances is identified. The domains where cooled coil materials such as copper, low- or high-temperature superconductors, could actually increase the RF coil sensitivity are delimited by a quantitative analysis of noise mechanisms. Technical keys, cryogenic means and cold RF coil technologies are considered, and first achievements in different fields of biomedical MRI are reviewed. This survey provides a basis for discussing about the future impact of cryogenic probes for MRI investigations.  相似文献   

3.
Proteins belonging to a family of compounds known as “antifreeze proteins” interact with occytes and protect the oolemma from damage at cryogenic temperatures. Experiments were performed with pig oocytes rapidly cooled to cryogenic temperatures in vitrifying solutions with and without antifreeze proteins. Four different types of antifreeze polypeptides and glycoproteins were tested. The integrity of the oolemma was examined with Fluoroscein Diacetate (FDA) staining and morphological examinations. Results show that the pig oocyte oolemma is a primary site of injury during exposure to low temperatures and that all the different proteins have a similar ability to interact with and protect the oolemma. Our results may be important in developing solutions for long-term preservation of oocytes at cryogenic temperatures (cryopreservation). © 1993 Wiley-Liss, Inc.  相似文献   

4.
The structural investigation of noncrystalline, soft biological matter using x-rays is of rapidly increasing interest. Large-scale x-ray sources, such as synchrotrons and x-ray free electron lasers, are becoming ever brighter and make the study of such weakly scattering materials more feasible. Variants of coherent diffractive imaging (CDI) are particularly attractive, as the absence of an objective lens between sample and detector ensures that no x-ray photons scattered by a sample are lost in a limited-efficiency imaging system. Furthermore, the reconstructed complex image contains quantitative density information, most directly accessible through its phase, which is proportional to the projected electron density of the sample. If applied in three dimensions, CDI can thus recover the sample''s electron density distribution. As the extension to three dimensions is accompanied by a considerable dose applied to the sample, cryogenic cooling is necessary to optimize the structural preservation of a unique sample in the beam. This, however, imposes considerable technical challenges on the experimental realization. Here, we show a route toward the solution of these challenges using ptychographic CDI (PCDI), a scanning variant of coherent imaging. We present an experimental demonstration of the combination of three-dimensional structure determination through PCDI with a cryogenically cooled biological sample—a budding yeast cell (Saccharomyces cerevisiae)—using hard (7.9 keV) synchrotron x-rays. This proof-of-principle demonstration in particular illustrates the potential of PCDI for highly sensitive, quantitative three-dimensional density determination of cryogenically cooled, hydrated, and unstained biological matter and paves the way to future studies of unique, nonreproducible biological cells at higher resolution.  相似文献   

5.
We describe a general protocol for preparing protein-containing biofluids for 1H nuclear magnetic resonance (NMR) metabolomic studies. In this protocol, untreated samples are diluted in deuterated solvents to precipitate proteins and recover metabolites quantitated relative to standard reference compounds such as 3-trimethylsilylpropionic acid (TSP) and 2,2-dimethyl-2-silapentane-5-sulfonic acid (DSS). The efficacy of this protocol was tested using a bovine serum albumin/metabolite mix and human serum samples. This sample preparation method can be readily applied to any protein-containing biofluid for 1H NMR studies.  相似文献   

6.
Atomic force microscopy (AFM) has been applied in many biological investigations in the past 15 years. This review focuses on the application of AFM for quantitatively characterizing the structural and thermodynamic properties of protein-protein and protein-nucleic acid complexes. AFM can be used to determine the stoichiometries and association constants of multiprotein assemblies and to quantify changes in conformations of proteins and protein-nucleic acid complexes. In addition, AFM in solution permits the observation of the dynamic properties of biomolecular complexes and the measurement of intermolecular forces between biomolecules. Recent advances in cryogenic AFM, AFM on two-dimensional crystals, carbon nanotube probes, solution imaging, high-speed AFM, and manipulation capabilities enhance these applications by improving AFM resolution and the dynamic and operative capabilities of the AFM. These developments make AFM a powerful tool for investigating the biomolecular assemblies and interactions that govern gene regulation.  相似文献   

7.
Mixed microbial communities are complex, dynamic and heterogeneous. It is therefore essential that biomolecular fractions obtained for high-throughput omic analyses are representative of single samples to facilitate meaningful data integration, analysis and modeling. We have developed a new methodological framework for the reproducible isolation of high-quality genomic DNA, large and small RNA, proteins, and polar and non-polar metabolites from single unique mixed microbial community samples. The methodology is based around reproducible cryogenic sample preservation and cell lysis. Metabolites are extracted first using organic solvents, followed by the sequential isolation of nucleic acids and proteins using chromatographic spin columns. The methodology was validated by comparison to traditional dedicated and simultaneous biomolecular isolation methods. To prove the broad applicability of the methodology, we applied it to microbial consortia of biotechnological, environmental and biomedical research interest. The developed methodological framework lays the foundation for standardized molecular eco-systematic studies on a range of different microbial communities in the future.  相似文献   

8.
Large-scale manufacturing of therapeutic cells requires bioreactor technologies with online feedback control enabled by monitoring of secreted biomolecular critical quality attributes (CQAs). Electrospray ionization mass spectrometry (ESI-MS) is a highly sensitive label-free method to detect and identify biomolecules, but requires extensive sample preparation before analysis, making online application of ESI-MS challenging. We present a microfabricated, monolithically integrated device capable of continuous sample collection, treatment, and direct infusion for ESI-MS detection of biomolecules in high-salt solutions. The dynamic mass spectrometry probe (DMSP) uses a microfluidic mass exchanger to rapidly condition samples for online MS analysis by removing interfering salts, while concurrently introducing MS signal enhancers to the sample for sensitive biomolecular detection. Exploiting this active conditioning capability increases MS signal intensity and signal-to-noise ratio. As a result, sensitivity for low-concentration biomolecules is significantly improved, and multiple proteins can be detected from chemically complex samples. Thus, the DMSP has significant potential to serve as an enabling portion of a novel analytical tool for discovery and monitoring of CQAs relevant to therapeutic cell manufacturing.  相似文献   

9.
We have proposed solid state NMR (SSNMR) of sedimented solutes as a novel approach to sample preparation for biomolecular SSNMR without crystallization or other sample manipulations. The biomolecules are confined by high gravity—obtained by centrifugal forces either directly in a SSNMR rotor or in a ultracentrifugal device—into a hydrated non-crystalline solid suitable for SSNMR investigations. When gravity is removed, the sample reverts to solution and can be treated as any solution NMR sample. We here describe a simple web tool to calculate the relevant parameters for the success of the experiment.  相似文献   

10.
Sediment in urine may contain low-molecular-weight compounds that should be included in the analysis. To date, no systematic investigation has addressed this issue. We investigated three primary factors that influence the extraction efficiency of metabolites during preparation of urine samples for metabolomic research: centrifugation, pH, and extraction solvents. Obtained with the use of gas chromatography/time-of-flight mass spectrometry (GC/TOFMS) technique and principal component analysis (PCA), our results indicate that (1) conventional centrifugation causes an apparent loss of some metabolites, indicating that urine samples for metabolomic research should not be centrifuged before procedures are undertaken to recover the metabolites; (2) pH adjustment has a large impact on the recovery of metabolites and is therefore not encouraged; (3) with design of experiment analysis, methanol and water yield the optimal extraction efficiency. Differences between rat and human urine were observed and are discussed. Ninety-nine metabolites identified in rat and human urine are presented. An efficient protocol is proposed for the pretreatment of urine samples.  相似文献   

11.
The minimization of preanalytical variables in sample preparation is imperative for successful discovery-driven and translational research involving large-scale biomolecular profiling. Here, we demonstrate a novel technique using high hydrostatic pressure in addition to several chaotropes and solvents to maximize efficiency of both cell lysis and enzymatic digestion while minimizing the time, manual involvement in sample processing, and preanalytical variability introduced prior to mass spectrometry-based proteomic analysis. The digestion techniques were evaluated and optimized for in-solution, in-gel, and on-membrane applications using protein standards and cell lysates. The lysis techniques were evaluated using human HepG2 cells. Our results demonstrate that the use of elevated pressure and organic solvents can achieve superior protein recovery of organelle-, complex-, and especially membrane-associated proteins, meanwhile obtaining more than a 20-fold increase in throughput with improved reproducibility. This study introduces the concept of ultrahigh-performance sample preparation platforms for targeted characterization of proteome subsets in biological systems.  相似文献   

12.
Structural and functional imaging with carbon nanotube AFM probes   总被引:11,自引:0,他引:11  
Atomic force microscopy (AFM) has great potential as a tool for structural biology, a field in which there is increasing demand to characterize larger and more complex biomolecular systems. However, the poorly characterized silicon and silicon nitride probe tips currently employed in AFM limit its biological applications. Carbon nanotubes represent ideal AFM tip materials due to their small diameter, high aspect ratio, large Young's modulus, mechanical robustness, well-defined structure, and unique chemical properties. Nanotube probes were first fabricated by manual assembly, but more recent methods based on chemical vapor deposition provide higher resolution probes and are geared towards mass production, including recent developments that enable quantitative preparation of individual single-walled carbon nanotube tips [J. Phys. Chem. B 105 (2001) 743]. The high-resolution imaging capabilities of these nanotube AFM probes have been demonstrated on gold nanoparticles and well-characterized biomolecules such as IgG and GroES. Using the nanotube probes, new biological structures have been investigated in the areas of amyloid-beta protein aggregation and chromatin remodeling, and new biotechnologies have been developed such as AFM-based haplotyping. In addition to measuring topography, chemically functionalized AFM probes can measure the spatial arrangement of chemical functional groups in a sample. However, standard silicon and silicon nitride tips, once functionalized, do not yield sufficient resolution to allow combined structural and functional imaging of biomolecules. The unique end-group chemistry of carbon nanotubes, which can be arbitrarily modified by established chemical methods, has been exploited for chemical force microscopy, allowing single-molecule measurements with well-defined functionalized tips.  相似文献   

13.
Two fully automated HPLC-NMR methods are reported and compared for the structure elucidation of four isomeric tropane alkaloids from the stem-bark of an endemic Chilean plant, Schizanthus grahamii Gill. (Solanaceae). The first approach interfaced a conventional HPLC column to NMR by means of a loop storage unit. After elution with a mobile phase consisting of deuterated water and standard protonated organic solvents, the separated analytes were momentarily stored in a loop cassette and then transferred one-at-a-time to the NMR flow probe for measurements. The second strategy combined HPLC with parallel ion-trap MS detection and NMR spectroscopy using an integrated solid-phase extraction (SPE) unit for post-column analyte trapping. The SPE cartridges were dried under a gentle stream of nitrogen and analytes were sequentially eluted and directed to a cryogenically cooled flow-probe with an NMR-friendly solvent. The structures of the four isomeric alkaloids, 3alpha-senecioyloxy-7beta-hydroxytropane, 3alpha-hydroxy-7beta-angeloyloxytropane, 3alpha-hydroxy-7beta-tigloyloxytropane and 3alpha-hydroxy-7beta-senecioyloxytropane, were unambiguously determined by combining NMR assignments with MS data.  相似文献   

14.
The use of nucleic acid probes directly labeled with horseradish peroxidase for detection of single copy sequences on Southern blots of human genomic DNA by enhanced chemiluminescence is described. Of the target sequences, 6 x 10(5) molecules (1 amol) have been detected on blue sensitive film using exposures of up to 60 min and probes of 0.3-5.1 kb. The chemiluminescent signal quantified using a cooled charge coupled device (CCD) camera is proportional to probe length for DNA probes in the range 50-3571 bases. The enzyme has no significant effect on the stability of a DNA/DNA hybrid formed with a 3571-base probe and target as determined by increasing the stringency of posthybridization washes by decreasing the concentration of a monovalent cation (NaCl) and by a Tm analysis. The kinetics of DNA hybridization have been analyzed by a cooled CCD camera to provide quantitative data. Ten nanograms per milliliter of probe may be used for an overnight hybridization. Southern blots can be reprobed using a DNA probe for the same or a different sequence without the necessity of stripping off the previously bound probe.  相似文献   

15.
We have assessed the potential of an alternative probe tuning strategy based on the spin-noise response for application in common high-resolution multi-dimensional biomolecular NMR experiments with water signal suppression on aqueous and salty samples. The method requires the adjustment of the optimal tuning condition, which may be offset by several 100 kHz from the conventional tuning settings using the noise response of the water protons as an indicator. Although the radio frequency-pulse durations are typically longer under such conditions, signal-to-noise gains of up to 22% were achieved. At salt concentrations up to 100 mM a substantial sensitivity gain was observed.  相似文献   

16.
Hybridization solutions containing chaotropes may be used to modulate the thermal stability (Tm or Td) of oligodeoxynucleotide (ODN) duplexes or hybrids over a 90 degrees C range. Modulation of Td allows formulation of hybridization solutions that permit ambient temperature hybridization using most combinations of probe length, probe composition, target type, and facilitates development of convenient and rapid assay formats. The conditions required to achieve ODN duplex fidelity, and optimal yields of hybridized product, are described for trichloroacetate, thiocyanate, guanidinium salts and other chaotropic salts. The effects of different solid supports on Td are described. Also, a method is presented that uses chaotropic compounds to reduce background arising from signal ODN probes in a sandwich assay hybridization format.  相似文献   

17.
Here we present a protocol used to prepare cryo-TEM samples of Aspergillus niger spores, but which can easily be adapted for any number of microorganisms or solutions. We make use of a custom built cryo-transfer station and a modified cryo-SEM preparation chamber2. The spores are taken from a culture, plunge-frozen in a liquid nitrogen slush and observed in the cryo-SEM to select a region of interest. A thin lamella is then extracted using the FIB, attached to a TEM grid and subsequently thinned to electron transparency. The grid is transferred to a cryo-TEM holder and into a TEM for high resolution studies. Thanks to the introduction of a cooled nanomanipulator tip and a cryo-transfer station, this protocol is a straightforward adaptation to cryogenic temperature of the routinely used FIB preparation of TEM samples. As such it has the advantages of requiring a small amount of modifications to existing instruments, setups and procedures; it is easy to implement; it has a broad range of applications, in principle the same as for cryo-TEM sample preparation. One limitation is that it requires skillful handling of the specimens at critical steps to avoid or minimize contaminations.  相似文献   

18.
The field of metabolomics is getting more and more popular and a wide range of different sample preparation procedures are in use by different laboratories. Chemical extraction methods using one or more organic solvents as the extraction agent are the most commonly used approach to extract intracellular metabolites and generate metabolite profiles. Metabolite profiles are the scaffold supporting the biological interpretation in metabolomics. Therefore, we aimed to address the following fundamental question: can we obtain similar metabolomic results and, consequently, reach the same biological interpretation by using different protocols for extraction of intracellular metabolites? We have used four different methods for extraction of intracellular metabolites using four different microbial cell types (Gram negative bacterium, Gram positive bacterium, yeast, and a filamentous fungus). All the quenched samples were pooled together before extraction, and, therefore, they were identical. After extraction and GC?CMS analysis of metabolites, we did not only detect different numbers of compounds depending on the extraction method used and regardless of the cell type tested, but we also obtained distinct metabolite levels for the compounds commonly detected by all methods (P-value?<?0.001). These differences between methods resulted in contradictory biological interpretation regarding the activity of different metabolic pathways. Therefore, our results show that different solvent-based extraction methods can yield significantly different metabolite profiles, which impact substantially in the biological interpretation of metabolomics data. Thus, development of alternative extraction protocols and, most importantly, standardization of sample preparation methods for metabolomics should be seriously pursued by the scientific community.  相似文献   

19.
Magic angle spinning nuclear magnetic resonance (MAS NMR) is well suited for the study of membrane proteins in membrane mimetic and native membrane environments. These experiments often suffer from low sensitivity, due in part to the long recycle delays required for magnetization and probe recovery, as well as detection of low gamma nuclei. In ultrafast MAS experiments sensitivity can be enhanced through the use of low power sequences combined with paramagnetically enhanced relaxation times to reduce recycle delays, as well as proton detected experiments. In this work we investigate the sensitivity of 13C and 1H detected experiments applied to 27 kDa membrane proteins reconstituted in lipids and packed in small 1.3 mm MAS NMR rotors. We demonstrate that spin diffusion is sufficient to uniformly distribute paramagnetic relaxation enhancement provided by either covalently bound or dissolved CuEDTA over 7TM alpha helical membrane proteins. Using paramagnetic enhancement and low power decoupling in carbon detected experiments we can recycle experiments ~13 times faster than under traditional conditions. However, due to the small sample volume the overall sensitivity per unit time is still lower than that seen in the 3.2 mm probe. Proton detected experiments, however, showed increased efficiency and it was found that the 1.3 mm probe could achieve sensitivity comparable to that of the 3.2 mm in a given amount of time. This is an attractive prospect for samples of limited quantity, as this allows for a reduction in the amount of protein that needs to be produced without the necessity for increased experimental time.  相似文献   

20.
A number of new 9-anthracenecarboxamides are synthesized in order to create new fluorescent probes for studying biological systems. The parameters of their fluorescence in organic solvents of various polarities are investigated, and possible mechanisms of internal quenching of fluorescence of these compounds are discussed. One of the compounds, 4-ethoxycarbonylphenylamide of 9-anthracenecarboxylic acid, is shown to be a promising basis for the development of a new fluorescent probe.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号