首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A new HPLC assay using UV detection (200 nm) was developed to determine ethambutol (EMB) concentrations in plasma. Following extraction (0.1 ml plasma) with chloroform, EMB and octylamine (used as internal standard) were derivatized with phenylethylisocyanate. Quantitation in plasma was achieved at 200 nm. There were no interferences from endogenous compounds. Intra- and inter-day variabilities were lower than 5.2 and 7.6%, respectively. The limit of quantitation of the method was 0.2 μg/ml. In plasma, ethambutol was found to be stable for at least one month when samples were stored at −20°C. This assay was applied to the therapeutic monitoring of EMB concentrations in 19 patients suffering from tuberculosis.  相似文献   

2.
A rapid, sensitive and reproducible high-performance liquid chromatographic assay for busulfan in human plasma was developed. After extraction of plasma samples with acetonitrile and methylene chloride, busulfan and the internal standard [1,5-bis(methanesulfonyloxy)pentane] were derivatized with 8-mercaptoquinoline to yield fluorescent compounds which were detected with a fluorescence detector equipped with filters of 360 nm (excitation) and 425 nm (emission). Calibration graphs showed a linear correlation (r>0.9990) over the concentration range of 20–2000 ng/ml. The recovery of busulfan from plasma standards was 70±5%. The detection and quantification limits for busulfan in plasma samples were established at 9 ng/ml and 20 ng/ml, respectively. The intra- and inter-assay variations were lower than 8% and 10%, respectively. The applicability of the method was verified by analyzing the plasma concentrations of busulfan in a patient to whom it was administered orally on two different days.  相似文献   

3.
A method is described for the determination of cortisol in human plasma and urine by high-performance liquid chromatography using fluorophotometric detection. After extraction with methylene chloride, cortisol is labelled with dansyl hydrazine, and then separated by high-performance chromatography. The eluate is monitored by a fluorophotometer at 350 nm (excitation) and 505 nm (emission). The optimum conditions for the determination, such as HCl and dansyl hydrazine concentrations, reaction time and reaction temperature, and for the eluent of high-performance liquid chromatography, are discussed. Linearity of the fluorescence intensity (peak height) with the amount of cortisol was obtained between 0.5 and 60 ng. The recoveries for 50 and 100 ng of added cortisol were 98.7 and 95.4% for plasma, and 96.4 and 90.6% for urine, respectively. Comparison with a radioimmunoassay gave a correlation coefficient of 0.978. The proposed method is suitable for the routine analysis of cortisol in plasma and urine.  相似文献   

4.
A simple, selective, and sensitive liquid chromatographic method with ultraviolet detection was developed for the analysis of penicillin G in bovine plasma. The assay utilizes a simple extraction of penicillin G from plasma (with a known amount of penicillin V added as internal standard) with water, dilute sulphuric acid and sodium tungstate solutions, followed by concentration on a conditioned C18 solid-phase extraction column. After elution with 500 μl of elution solution, the penicillins are derivatized with 500 μl of 1,2,4-triazole—mercuric chloride solution at 65°C for 30 min. The penicillin—mercury mercaptide complexes are separated by reversed-phase liquid chromatography on a C18 column. The method, which has a detection limit of 5 ng/ml (ppb) in bovine plasma, was used to quantitatively measure the concentrations of penicillin G in plasma of steers at a series of intervals after the intramuscular administration of a commercial formulation of procaine penicillin G.  相似文献   

5.
Analysis of plasma catecholamines (norepinephrine, epinephrine and dopamine) by high-performance liquid chromatography using 1,2-diphenylethylenediamine as a fluorescent reagent is described. We have developed an automatic catecholamine analyser, based on pre-column fluorescence derivatization and column switching. The analysis time for one assay was 15 min. The correlation coefficients of the linear regression equations were greater than 0.9996 in the range 10–10 000 pg/ml. The detection limit, at a signal-to-noise ratio of 3, was 2 pg/ml for dopamine. A new method of sample preparation for the pre-column fluorescence derivatization of plasma catecholamines was used. In order to protect the catecholamines from decomposition, an ion-pair complex between boric acid and the diol group in the catecholamine was formed at a weakly alkaline pH. The stabilities of plasma catecholamines were evaluated at several temperatures. After complex formation, the catecholamines were very stable at 17°C for 8 h, and the coefficients of variation for norepinephrine, epinephrine and dopamine were 1.2, 4.2 and 9.3%, respectively.  相似文献   

6.
A method is reported for determination of allantoin in urine and plasma based on high-performance liquid chromatography (HPLC) and pre-column derivatization. In the derivatization procedure, allantoin is converted to glyoxylic acid which forms a hydrazone with 2,4-dinitrophenylhydrazine. The hydrazone appears as syn and anti isomers at a constant ratio. These derivatives are separated by HPLC using a reversed-phase C18 column from hydrazones of other keto acids possibly present in urine and plasma and then monitored at 360 nm. All components were completely resolved in 15 min. Both the reagents and derivatization products are stable. Recovery of allantoin added to urine and plasma was 95 ± 3.7% (n = 45) and 100 ± 7.5% (n = 64), respectively. The lowest allantoin concentration that gave a reproducible integration was 5 μmol/l. The between-assay and within-day coefficients of variation were 2.8 and 0.6%, respectively.  相似文献   

7.
Simultaneous determination method of N-acetyl-l-aspartyl-l-glutamate (NAAG), an endogenous agonist at type 3 metabotropic glutamate receptor, and its degradation product, N-acetyl-l-aspartate (NAA) was developed by using reversed-phase high-performance liquid chromatography (HPLC) with pre-column fluorescence derivatization using 4-N,N-dimethylaminosulfonyl-7-N-(2-aminoethyl)amino-2,1,3-benzoxadiazole. The detection limits of NAAG and NAA were approximately 12 and 34 fmol on the column, respectively (signal to noise ratio 3). The proposed HPLC method was applied to determine NAAG and NAA simultaneously in the rat brain homogenate. Both concentrations of NAAG and NAA in the male rat cerebrum (13 weeks old) were 5.7+/-0.30 and 2.1 x 10(2)+/-9.2 nmol/mg protein, respectively (n=6), while those in the hippocampus were 6.8+/-0.48 and 1.9 x 10(2)+/-8.5 nmol/mg protein, respectively (n=5). Hippocampal NAA concentration was significantly increased in the ketamine-treated rats as compared to the control rats (p<0.01).  相似文献   

8.
9.
A simple procedure for the determination of amphetamine in urine with minimal sample preparation is described. This method involves direct addition of human urine to an acetone-dansyl chloride solution for simultaneous deproteinization and fluorescence derivatization. The derivatized amphetamine is then measured by HPLC with fluorescence detection. It eliminates the extraction procedures often required by other HPLC or GC methods. The effects of pH, temperature and reaction time on the derivatization reaction were investigated. The stability of amphetamine-dansyl chloride in different storage conditions was examined. The detection limit and linearity associated with this assay are discussed.  相似文献   

10.
A reliable and semi-automated high-performance liquid chromatographic (HPLC) method is described for the determination of total vitamin C in whole blood. After deproteinization of whole blood and enzymatic oxidation of l-ascorbic acid to dehydro-l-ascorbic acid, the latter is condensed with o-phenylenediamine to its quinoxaline derivative. This derivative is separated on a reversed-phase HPLC column and detected fluorometrically. Total vitamin C in whole blood can be determined in concentrations as low as 0.2 μmol/l.Special attention was paid to the stability of vitamin C in whole blood and of its quinoxaline derivative in the extract. Results of our investigations showed that total vitamin C in whole blood is stable for eight days at −20°C, provided ethyleneglycol-bis-(β-amino-ethyl ether)-N,N,N′,N′-tetraacetic acid and glutathione are immediately added to the blood sample. The quinoxaline derivative of vitamin C in the blood extract is stable for at least 24 h if stored in the dark at 4°C.Routine vitamin C determinations can be carried out in a series of 100 samples within 48 h. The within-assay and between-assay coefficients of variation were 3.7% and 4.6%, respectively. The between-assay analytical recovery of l-ascorbic acid added to whole blood samples was 97.0 ± 7.0% (mean ± S.D.). Reference values of vitamin C in whole blood of normal healthy Dutch adults were found in the range 20–80 μmol/l.  相似文献   

11.
Eighteen samples of commercially available Chinese beer were analyzed in order to determine the content of biogenic amines. The method involves pre-column derivatization of the amines with 4-chloro-3,5-dinitrobenzotrifluoride (CNBF) and subsequent analysis by RP-HPLC (reversed phase-high performance liquid chromatography) with diode array detection. The labeled biogenic amines were separated on a Kromasil C18 column (250 mm × 4.6 mm, 5 μm) at room temperature and UV detection was applied at 254 nm. The separation of seven labeled biogenic amines was achieved within 22 min by elution acetonitrile and HAc–NaAc buffers. The method linearity, calculated for each biogenic amine, has a correlation coefficient higher than 0.9925, in concentrations ranging from 2.9 μmol L?1 to 565 μmol L?1. Detection limits of biogenic amines were 0.056–0.87 μmol L?1, at a signal-to-noise ratio of 3. The proposed method has been applied to the quantitative determination of spermine, phenethylamine, spermidine, histamine, tyramine, tryptamine and putrescine in beer with recoveries of 91.9–103.1% and R.S.D. of 2.86–5.63%. Quantitation is relative to external standards. The results showed that each kind of beer examined contained at least three biogenic amines. Putrescine, histamine and tyramine were detected in all samples. Spermidine was detected in 89% of the beers. Spermine, tryptamine and phenylethylamine occurred in 78%, 61% and 44% of the beers examined, respectively. These levels were below the level that may elicit direct adverse reactions for most consumers.  相似文献   

12.
A high-performance liquid chromatographic method was developed for the determination of methylguanidine in biological fluids. Methylguanidine and the internal standard were isolated from plasma by cation-exchange solid-phase extraction prior to chromatographic analysis. Urine samples were diluted and injected directly onto the analytical column. Chromatographic separation was carried out on an Ultrasil cation-exchange column using a mixture of methanol and monochloroacetate (15/85, v/v) as the mobile phase. Postcolumn derivatization of methylguanidine was carried out using alkaline ninhydrin reagent and the resulting fluorescent product was detected on-line. The method was specific, sensitive, reproducible, and linear over a wide a range of concentrations. The lower limit of detection for methylguanidine in plasma and urine was 1 and 100 ng/ml, respectively. The method was successfully employed for quantification of the levels of methylguanidine in normal and uremic human subjects, normal dogs, and dogs with ischemic-induced acute or spontaneous chronic renal failure.  相似文献   

13.
A rapid and sensitive method for extracting temazepam from human serum and urine is presented. Free temazepam is extracted from plasma and urine samples using n-butyl chloride with nitrazepam as the internal standard. Temazepam glucuronide is analyzed as free temazepam after incubating extracts with β-glucuronidase. Separation is achieved using a C8 reversed-phase column with a methanol—water—phosphate buffer mobile phase. An ultraviolet detector operated at 230 nm is used and a linear response is observed from 20 ng/ml to 10 μg/ml. The limit of detection is 15.5 ng/ml and the limit of quantitation is 46.5 ng/ml. Coefficients of variation are less than 10% for concentrations greater than 50 ng/ml. Application of the methodology is demonstrated in a pharmacokinetic study using eight healthy male subjects.  相似文献   

14.
A new method for determining cycloserine in plasma samples is described. This method is based on the derivatization of cycloserine with p-benzoquinone, a reaction that takes place at the same time as the process of plasma deproteinization due to the presence of ethanol as solvent in the solution of the derivatization reagent. Four derivatives are obtained from this reaction. The main derivative is well correlated with the cycloserine concentration. The ratio between the volumes of the plasma sample and the reagent solution is 1:2 for a p-benzoquinone concentration of 1000 μg/mL. Elution from a C18 column was isocratic, using a mobile phase containing (v/v) 85% aqueous 0.1% formic acid solution, and 15% (v/v) of a mixture of methanol and acetonitrile (1:1), with a flow-rate of 1 mL/min, at 25°C. Determinations by fluorescence detection were achieved with excitation at 381 nm and emission at 450 nm, with a detection limit of 10 ng/mL for an injection volume of 5 μL. This method was validated and applied to the determination of cycloserine in blood plasma samples of several healthy volunteers.  相似文献   

15.
A new sensitive high-performance liquid chromatographic procedure for the determination of l-carnitine (LC), acetyl-l-carnitine (ALC) and propionyl-l-carnitine (PLC) in human plasma has been developed. Precolumn derivatization with 1-aminoanthracene (1AA), performed in phosphate buffer in the presence of 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) as catalyst, is involved. The fluorescent derivatives were isocratically separated on a reversed-phase column (C18). The eluate was monitored with a fluorimetric detector set at 248 nm (excitation wavelength) and 418 nm (emission wavelength). Because of the presence of endogenous carnitines, the validation was performed using dialyzed plasma. The identity of the derivatized compounds was assessed by mass spectrometry and the purity of the chromatographic peaks was confirmed by HPLC-tandem mass spectrometry. The limits of quantitation were 5 nmol/ml for LC, 1 nmol/ml for ALC and 0.25 nmol/ml for PLC. The recovery of the extraction procedure was in the range 82.6%–95.4% for all 3 compounds. Good linearity (R≈0.99) was observed within the calibration ranges studied: 5–160 nmol/ml for LC, 1–32 nmol/ml for ALC and 0.25–8 nmol/ml for PLC. Precision was in the range 0.3–16.8% and accuracy was always lower than 10.6%.  相似文献   

16.
A sensitive fluorimetric method for the determination of octopine, a member of opine family, is presented. The method is based on the formation of a fluorescent derivative of octopine with benzoin and the separation by high performance liquid chromatography using a reversed-phase column (Kaseisorb LC ODS-300) within 20 min. The octopine derivative is completely separated from other guanidino compounds including arginine which is generally very high in marine invertebrates. This method gives higher sensitivity, 5 pmol minimum detection, and better reproducibility than the electrophoresis method and colorimetric method.  相似文献   

17.
A selective and sensitive high-performance liquid chromatography (HPLC) method with fluorescence derivatization for the assay of guanylate cyclase (GC) activity is described. GTP and cGMP, which are the substrate and the product of GC, respectively, and other guanine-containing compounds are selectively converted by the reaction with (3,4-dimethoxyphenyl)glyoxal to the fluorescent derivatives. The derivatives were separated by reversed-phase HPLC. The limit of detection at a signal-to-noise ratio of 3 for cGMP was 10 fmol on the column. The sensitivity of this method was less than that of the conventional radioisotopic method, but this method is simple and convenient. Human platelet GC activity was measured, and the effects of some compounds were investigated.  相似文献   

18.
A sensitive and selective reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of polyoxyethyleneglycerol triricinoleate 35 (Cremophor EL; CrEL), which requires only microvolumes (20 μl) of plasma, has been developed and validated. The procedure is based on saponification of CrEL in alcoholic KOH, followed by extraction of the released fatty acid ricinoleic acid with chloroform and derivatization with 1-naphthylamine. Margaric acid was used as the internal standard. The products are separated using an HPLC system consisting of an analytical column packed with Spherisorb ODS-1 material and a mobile phase of methanol-acetonitrile-10 mM potassium phosphate buffer pH 7.0 (72:13:15, v/v). Detection was executed by UV absorption at 280 nm. The lower limit of quantitation and the lower limit of detection in plasma are 0.01 and 0.005% (v/v) of CrEL, respectively. The percentage deviation and precision of the procedure, over the validated concentration range of 0.01 to 1.0% (v/v) of CrEL in plasma, are ≤8.0% and ≤ 6.6%, respectively. Compared to the previously described bioassay, the presented HPLC method possesses superior sensitivity and reliability. Preliminary pharmacokinetic studies of CrEL in mice and patients receiving paclitaxel formulated in CrEL have demonstrated the applicability of the presented assay.  相似文献   

19.
A method for the determination of urinary

(M1) and

(M2) in man was developed. Clean-up of urine samples was obtained by a chromatographic technique using a short reversed-phase precolumn; purified samples were then deacetylated with porcine acylase I for 16 h at 37°C and deproteinized by centrifugal ultrafiltration. Derivatization was performed with o-phthaldialdehyde and 2-mercaptoethanol and the fluorescent derivatives were separated on a reversed-phase analytical column with a gradient mobile phase consisting of 50 mM acetate buffer (pH 6.5) and methanol. The retention times of the diastereoisomers of M1 (M1-“S” and M1-“R”) were 52.8 and 73.7 min, respectively; M2 diastereoisomers eluted as a single peak at 70.5 min. The fluorescence detector was set at 330 nm (excitation) and 440 nm (emission). The detection limit (at a signal-to-noise ratio of three) was about 7 μg/l. The method was applied to 25 urine samples from workers exposed to styrene. A relationship was found between urinary mandelic and phenylglyoxylic acids and mercapturic acids specific for styrene. Urine samples from ten non-exposed subjects showed no detectable amounts of analytes.  相似文献   

20.
Severe homocystinemia is frequently associated with vascular disease while the pathological consequences of moderate or slightly elevated plasma homocysteine are unknown. Cobalamin and folate deficiencies may result in an elevation of plasma homocysteine. A sensitive and reproducible assay for total plasma homocysteine has been developed. The essential steps in the assay include (i) conversion of homocysteine disulfides to free homocysteine with borohydride reduction; (ii) conjugation of homocysteine with monobromobimane; (iii) separation of homocysteine-bimane from other plasma thiol-bimane adducts by reverse-phase high-performance liquid chromatography; and (iv) detection and quantitation of homocysteine-bimane by fluorometry. The method has a sensitivity of 4.4 pmol of homocysteine and is highly reproducible (intra- and interassay coefficients of variation = 4.97 and 4.53%, respectively). The mean concentration of total plasma homocysteine in nonfasting adult males (n = 12) and females (n = 12) was 15.8 (range, 7.0-23.7) and 16.5 nmol/ml (range, 8.6-20.7), respectively. Markedly elevated levels of homocysteine were found in patients with cobalamin and folate deficiency. Total plasma homocysteine represents approximately 4% of borohydride-generated thiol reactivity in the plasma of normal individuals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号