首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
High-performance liquid chromatographic methods for the determination of dolichols in tissues and plasma have been developed. The tissue concentration of dolichols was measured by high-performance liquid chromatography with uv detection and plasma levels of dolichols were determined fluorometrically after derivatization with anthracene-9-carboxylic acid. In both methods, 2,2-didecaprenylethanol was used as an internal standard. The method with fluorescence detection was sufficiently sensitive to measure the concentration of dolichols in human plasma.  相似文献   

5.
6.
An HPLC method was developed and validated for the determination of mifepristone in human plasma. C(18) solid-phase extraction cartridges were used to extract plasma samples. Separation was by C(18) column; mobile phase, methanol-acetonitrile-water (50:25:25, v/v/v); flow rate, 0.8 ml/min; UV detection at 302 nm. The calibration curve was linear in the concentration range of 10 ng/ml to 20 microg/ml (r=0.9991). Within- and between-day variability were acceptable. The limit of detection for the assay was 6 ng/ml. Plasma samples were stable for at least 7 days in the state of plasma or residue treated at -20 degrees C. The method was simple, sensitive and accurate, and allowed to determine ng mifepristone in human plasma. It could be applied to assess the plasma level of mifepristone in women receiving low oral doses of mifepristone.  相似文献   

7.
A direct injection column-switching high-performance liquid chromatography (HPLC) method was developed and validated for quantification of zaltoprofen in rat plasma. Following dilution with mobile phase A, i.e. acetonitrile-10mM potassium phosphate buffer (pH 6.8) (12:88, v/v) samples were directly injected to the pre-column without sample pre-purification step. After endogenous plasma components were eluted to waste, the system was switched and the analyte was eluted to the trap column. Zaltoprofen was then back-flushed to the analytical column for separation with mobile phase B, i.e. acetonitrile-10mM potassium phosphate buffer (pH 6.8) (35:65, v/v) and quantification with an ultraviolet detector at 230 nm. The calibration curve was linear in the concentration range of 40-5000 ngmL(-1). This method has been fully validated and shown to be specific, accurate and precise. The method is simple, rapid and the sample preparation is minimal and appears to be useful for the pharmacokinetic study of zaltoprofen.  相似文献   

8.
Acetylation of the hydroxyl group in 20α-hydroxy-4--pregnen-3-one decreases the binding capacity of the molecule to transcortin to only 1% of that of progesterone. By this simple procedure it is possible to eliminate the influence of 20α-hydroxy-4-pregnen-3-one in determinations of progesterone concentrations by the competitive protein--binding method, which is highly desirable when a great number of samples are analyzed.  相似文献   

9.
10.
11.
12.
A previously published method was used for the determination of piroxicam in plasma samples obtained from rat. The sample preparation involved liquid extraction, centrifugation and evaporation. Separation of piroxicam from internal standard occurred on a reversed-phase C18 column with a mobile phase consisting of methanol-phosphate buffer pH 2 (45:55). The detection limit of the assay was 0.02–20 μg/ml. The assay linearity was good (typically r = 0.9992). The method was applied for determination of piroxicam in rats after administration of an oral dose of 2 mg/kg piroxicam.  相似文献   

13.
A high-performance liquid chromatographic method with ultraviolet (UV) detection was developed for measuring cefotaxime in rat and human plasma. The method used direct injection of the plasma supernatant after deproteinization with 70% perchloric acid. Degradation of cefotaxime in acidic medium was retarded by adding phosphate buffer before centrifuging the sample. The mobile phase was 0.05 M aqueous ammonium acetate-acetonitrile-tetrahydrofuran (87:11:2, v/v) adjusted to pH 5.5. Analysis was run at a flow-rate of 1.0 ml/min, and a detection wavelength of 254 nm was used. The method has a quantification limit of 0.20 microgram/ml. The within- and between-day coefficients of variation and accuracy values were less than 8% and +/-3%, respectively, while the recovery values were greater than 87% over the concentration range tested (0.20-50 microgram/ml). The speed, sensitivity, specificity and reproducibility of this method make it particularly suitable for the routine determination of cefotaxime in human plasma. Moreover, only a relatively small sample plasma volume (100 microliter) is required, allowing this method to be applied to samples taken from neonates.  相似文献   

14.
A highly sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of forsythiaside in rat plasma using epicatechin as internal standard. The analytes were extracted by solid-phase extraction and chromatographied on a C18 column eluted with a gradient mobile phase of acetonitrile and water both containing 0.2% formic acid. The detection was performed by negative ion electrospray ionization in multiple reaction monitoring mode, monitoring the transitions m/z 623 → 161 and m/z 289 → 109 for forsythiaside and epicatechin, respectively. The assay was linear over the concentration ranges of 2.0–50.0 and 50.0–5000.0 ng/mL with limits of detection and quantification of 0.2 and 1.0 ng/mL, respectively. The precision was <10.8% and the accuracy was >91.9%, and extraction recovery ranged from 81.3% to 85.0%. This method was successfully applied to a pharmacokinetic study of forsythiaside in rats after intravenous (20 mg/kg) and oral (100 mg/kg) administration, and the result showed that the compound was poorly absorbed with an absolute bioavailability being approximately 0.5%.  相似文献   

15.
16.
17.
Over recent years there has been a resurgence in the use of doxycycline in clinical practice, which does not depend on its antibacterial properties. This paper describes a method of determination of doxycycline in human plasma and atheromatous tissue using high-performance liquid chromatography (HPLC), and a cheap commercially available extraction system. Doxycycline is extracted in the mobile phase and injected directly into the HPLC system, avoiding time consuming drying up steps. A limit of detection of 0.125 μg/ml of plasma, and a relative standard deviation of 3% was achieved, making the method very reliable and useful for assays within the usual therapeutic range. The method has also been applied to the extraction of a mixture of tetracyclines from plasma and atherma with equal efficacy, making it useful for assays of this class of drugs in veterinary practice and assays of food contaminants.  相似文献   

18.
Felbamate (2-phenyl-1,3-propanediol dicarbamate) is a second generation antiepileptic drug used to treat seizures refractory to other antiepileptic drugs. With approximately 3500 new patients exposed annually, several important pharmacologic interaction questions remain unanswered necessitating the need for rapid and accurate methods of felbamate analysis in biological matrices. To this end, a rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the measurement of felbamate in mouse plasma and tissues and human plasma. Plasma (100 μL) and tissues homogenates (100 μL of 100 mg/mL) were spiked with internal standard (carisoprodol) prior to protein precipitation with acetonitrile. Samples were chromatographed on a XBridge Phenyl, 2.5 μm, 4.6 mm×50 mm column with quantitation by internal standard reference monitoring of the ion transitions m/z 239→117 for felbamate and m/z 261→176 for carisoprodol. Calibration curves were linear from 2.5 to 500 ng/mL in mouse or human plasma and 25-5000 pg/mg in tissue homogenates. Recoveries were greater than 97% for plasma and homogenates with accuracies >92% in any of the mouse matrices and >88% in human plasma. Comparable accuracies and precision were found with and without the use of the internal standard in preparation of the calibration curves and suggest that the internal standard may not be required.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号