首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A label-free carp vitellogenin sensor has a strong potential for on-site monitoring on the possible contamination of edible fish with endocrine disruptors as a sum parameter in an inland carp farm. In this study, we performed a sensitive detection for carp vitellogenin with a direct-binding optical waveguide lightmode spectroscopy-based immunosensor. Carp vitellogenin bound over the sensor surface quite specifically, judging from the sensor responses according to stepwise antibody immobilization. This was also supported by a negligible sensor response found at bovine serum albumin immobilization. When plotted in double-logarithmic scale for carp vitellogenin concentrations of 0.00675-67.5nM, a linear relationship was found between analyte concentration and sensor response, together with the limit of detection of 0.00675nM. The reusability of the immunosensor after the regeneration with 10mM HCl was reasonably good, as presumed from the coefficient of variability of 6.02% for nine repetitive measurements. The model sample prepared by spiking a purified carp vitellogenin into a 10-fold diluted vitellogenin-free carp serum in 9.45nM showed the response ratio of 96.70% against 9.45nM of the purified carp vitellogenin. When a female and male carp sera induced with 17beta-estradiol injection were analyzed, biomarker induction was even identifiable at 2000-fold serum dilution.  相似文献   

2.
A simple and direct immunosensor for the determination of carp (Carassius auratus) vitellogenin (Vtg), a female-specific protein, has been proposed based on an antibody-captured conducting polymer-coated electrode. The monoclonal antibody specific to carp (C. auratus) Vtg was immobilized by covalent coupling to the carboxylic acid group on the polymer. The antibody immobilization and antibody-antigen interaction have been demonstrated by means of quartz crystal microbalance and impedance spectroscopic techniques. The impedance change occurred at the sensor surface due to the specific immuno-interaction was utilized to determine Vtg. The sensor showed high selectivity and sensitive response to Vtg in a buffered medium without redox probe. Vtg was determined in the linear range from 1.0 to 8.0 microg/l with the standard deviation of +/-0.13 (n =3) and the detection limit was determined to be 0.42 microg/l. This method was applied to the determination of Vtg in real male and female carp (C. auratus) serum samples.  相似文献   

3.
Label-free detection of bisphenol A based on the impedance measurement was achieved with an impedimetric immunosensor. The immunosensor was fabricated by the covalent bond formation between a polyclonal antibody and a carboxylic acid group functionalized onto a nano-particle comprised conducting polymer. By using a commercial reagent 4,4-bis(4-hydroxyphenyl) valeric acid (BHPVA), which has an analogous structure of BPA, we have prepared the antigen through the conjugation of BHPVA with bovine serum albumin (BSA) and then produced a specific polyclonal antibody. The immobilization of antibody and the interaction between antibody and antigen were studied using quartz crystal microbalance (QCM) and electrochemical impedance spectroscopic (EIS) techniques. The impedance and mass changes due to the specific immuno-interaction at the sensor surface were utilized to detect antigen and bisphenol A (BPA). The immunosensor showed specific recognition of BPA with less interference than 4.5% from other common phenolic compounds. Under an optimized condition, the linear dynamic range of BPA detection was between 1 and 100 ng/ml. The detection limit of bisphenol A was determined to be 0.3+/-0.07 ng/ml. The proposed immunosensor was applied to a human serum sample and the BPA concentration was determined by the standard addition method.  相似文献   

4.
Osteoprotegerin (OPG, osteoclastogenesis inhibitory factor) is a secretory glycoprotein involved as a soluble factor in the regulation of bone mass. OPG and its ligand (RANKL) levels in serum indicate the osteoclast formation activity. Alterations of the RANKL/OPG concentration ratio may be the cause of bone loss in many imbalances including osteoporosis, hypercalcaemia, metastatic osteolytic lesions and rheumatic bone degradation. The interactions of OPG with several antibodies were studied using the piezoelectric quartz crystal sensor. Monoclonal anti-OPG antibodies (5H3, 4E6H9 and OPG1.3) were immobilised on the sensing surface modified with covalently attached monolayer of protein A. Binding of both OPG standard and recombinant OPGFc chimeric protein was followed in real time. All antibodies were able to bind OPG and OPGFc, though in the case of MAb 4E6H9 the immunocomplexes dissociated quickly in the absence of OPG. Alternatively, biorecognition layers with RANKL were used. Two versions of the piezoelectric sensor for OPG were developed. The direct immunosensor was based on the antibody 5H3 and the affinity sensor employed the immobilised RANKL. The RANKL sensor exhibited poor reproducibility of results. For the immunosensor, the measuring range was 1.2-35 U/L of OPG. One analysis was completed within 15 min; the sensors were used repeatedly using regeneration with glycine buffer (pH 2.0). The developed immunosensor seems promising for rapid determination of osteoprotegerin in serum.  相似文献   

5.
A novel multi-channel 2 x 5 model of piezoelectric quartz micro-array immunosensor has been developed for quantitative detection of human chorionic gonadotropin (hCG) in serum or urine samples. Every crystal unit of the fabricated piezoelectric hCG micro-array immunosensor can oscillate independently without interfering each other. A 2 x 5 model of micro-array immunosensor as compared with a one-channel immunosensor can provide eight times higher detection speeds for hCG assay. The anti-hCG antibody is deposited on the gold electrode's surface of 10 MHz quartz AT-cut crystal by self-assembled technique using sulfosuccinimidyl 6-[3'-(2-pyridyldithio) propionamido] hexanoate (Sulfo-LC-SPDP), and serves as an antibody recognizing layer. The highly ordered self-assembled monolayers (SAM) ensure well-controlled surface structure and offer many advantages to the performance of the sensor. Compared with conventional antibody immobilization methods, the amount and the reaction activity of antibody monolayer coated by the SAM binding are bigger than those by the SPA method, and less non-specific binding caused by other analytes in sample is found. Under the optimized experimental conditions, the results showed that micro-array immunosensor quantitatively detected serum or urine hCG in the range of 2.5-500 mIU/ml with high precision (CV<5%); other hormones in human serum and urine did not interfere with the determination markedly. Serum and urine samples of 60 patients were detected by the micro-array immunosensor, and the results agreed well with those given by the commercial radioimmunoassay test kit, with correlation coefficient of 0.92. After regeneration with urea solution the coated immunosensor can be reused five times without appreciable loss of activity.  相似文献   

6.
Sensitive electrochemical immunosensor for the detection of protein biomarker tumor necrosis factor α (TNF-α) was reported that uses ferrocene carboxylic acid (Fc) functionalized self-assembled peptide nanowire (Fc-PNW) as sensor platform and glucose oxidase (GOx) modified gold nanorod (GNR) as label. Greatly enhanced sensitivity is achieved based on a dual signal amplification strategy: first, the synthesized Fc-PNW used as the sensor platform increased the loading of primary anti-TNF-α antibody (Ab(1)) onto electrode surface due to its large surface area. At the same time, the Fc moiety on the nanowire is used as a mediator for GOx to catalyze the glucose reaction. Second, multiple GOx and secondary anti-TNF-α antibody (Ab(2)) molecules are bounded onto each GNR to increase the sensitivity of the immunosensor. After the preparation of the immunosensor based on the traditional sandwich protocol, the response of the immunosensor towards glucose was used as a signal to differentiate various concentrations of TNF-α. The resulting immunosensor has high sensitivity, wide linear range (0.005-10ng/mL) and good selectivity. This immunosensor preparation strategy is a promising platform for clinical screening of protein biomarkers.  相似文献   

7.
A model optical immunosensor was developed to quantify an antibody present in a sample by measuring the fluorescence of Cyanine-5 conjugated with the antibody, using a competitive and a sandwich immunoreaction configuration, with the antigen immobilised in controlled pore glass beads. At pH 2, 94% of the antigen-antibody complex was dissociated, allowing reutilisation. Photobleaching had no effect on the fluorescence. This model system was used to detect Brucella sp. infection and could quantify anti-Brucella sp. antibodies in ovine serum samples in the range from 0.005 to 0.11 mg ml(-1).  相似文献   

8.
We report herein the development of an optical fiber based chemiluminescent immunosensor for detection of the native autoimmune response to GIPC-1, a PDZ containing protein involved in regulation of G-protein signaling. The recombinant protein GIPC-1 was expressed in bacteria, purified, refolded and conjugated to the tip of an optical fiber. A human monoclonal 27.B1 IgM isolated from a breast cancer patient, which targets the GIPC-1 protein, was used for calibration of the immunosensor and was detected down to a concentration of 30 pg/ml. We determined that the fiber-optic immunosensor had a detection limit 50 times lower than chemiluminescent ELISA, and approximately 500 times lower than colorimetric ELISA. In addition, sera from 11 ovarian cancer patients, 22 breast cancer patients and asymptomatic controls were tested for the presence of IgM anti-GIPC-1 autoantibodies in their serum using the two methods. The immunosensor assay detected 54% and 77% GIPC-1 positive sera within ovarian and breast cancer patients, respectively, as compared to chemiluminescent ELISA, which only detected 18% and 27%, respectively. We envision that this immunosensor may serve as a diagnostic tool for screening women for ovarian and breast cancer at an early stage, thus increasing their chance of survival.  相似文献   

9.
Qu F  Lu H  Yang M  Deng C 《Biosensors & bioelectronics》2011,26(12):4810-4814
A new electrochemical immunosensor for the detection of protein biomarker platelet-derived growth factor BB (PDGF-BB) was developed based on graphene oxide (GO) initiated silver enhancement. The immunosensor was fabricated based on the traditional sandwich protocol using secondary anti-PDGF-BB antibody (Ab(2)) modified GO as label. Gold electrode was first modified with self-assembled monolayer (SAM) to block the electron transfer between the electrode and K(3)Fe(CN)(6) solution. After the immobilization of primary anti-PDGF-BB antibody (Ab(1)) onto electrode via aminidation to the carboxylic group of SAM and the formation of the sandwich immuno-structure onto electrode surface, the electrode was immersed into silver enhancement solution for silver deposition. The deposited metal silver onto GO then mediated electron transfer across the SAM, producing redox current. The resulting immunosensor displays a wide range of linear response, low detection limit, good reproducibility and stability. The immunosensor was used to the detection of PDGF-BB contents in serum samples with satisfactory results.  相似文献   

10.
A simple and rapid continuous-flow immunosensor based on surface plasmon resonance (SPR) has been developed for detection of insulin as low as 1 ng ml-1 (ppb) with a response time of less than 5 min. At first, a heterobifunctional oligo(ethyleneglycol)-dithiocarboxylic acid derivative (OEG-DCA) containing dithiol and carboxyl end groups was used to functionalize the thin Au-film of SPR chip. Insulin was covalently bound to the Au-thiolate monolayer of OEG-DCA for activating the sensor surface to immunoaffinity interactions. An on-line competitive immunosensing principle is examined for detection of insulin, in which the direct affinity binding of anti-insulin antibody to the insulin on sensor surface is examined in the presence and absence of various concentrations of insulin. Immunoreaction of anti-insulin antibody with the sensor surface was optimized with reference to antibody concentration, sample analysis time and flow-rate to provide the desired detection limit and determination range. With the immunosensor developed, the lowest detectable concentration of insulin is 1 ng ml-1 and the determination range covers a wide concentration of 1-300 ng ml-1. The developed OEG-monolayer based sensor chip exhibited high resistance to non-specific adsorption of proteins, and an uninterrupted highly sensitive detection of insulin from insulin-impregnated serum samples has been demonstrated. After an immunoreaction cycle, active sensor surface was regenerated simply by a brief flow of an acidic buffer (glycine.HCl; pH 2.0) for less than 1 min. A same sensor chip was found reusable for more than 25 cycles without an appreciable change in the original sensor activity.  相似文献   

11.
Wei J  Mu Y  Song D  Fang X  Liu X  Bu L  Zhang H  Zhang G  Ding J  Wang W  Jin Q  Luo G 《Analytical biochemistry》2003,321(2):209-216
Common methods for monitoring human cardiac troponin I (cTn I) are based on using antibodies against cTn I labeled with horseradish peroxidase, radioactive isotopes, or other labels. In this study, a novel label-free sandwich immunosensing method for measuring cTn I was developed. Three monoclonal antibodies (mAbs 9F5, 2F11, and 8C12) against human cTn I were generated by the commonly used hybridoma technique and characterized by a surface plasmon resonance (SPR) biosensor. An optimal pair of mAbs for measuring human cTn I was selected, as both mAbs have high affinities for cTn I and do not compete against each other for cTn I binding. An optical immunosensor for measuring cTn I in sera based on SPR was developed by using avidin as an intermediate layer and biotinylated-2F11 as the capturing antibody. Two detection methods for cTn I with the immunosensor were performed: (1) the direct detection of cTn I with a detection range of 2.5 to 40 microg/L and (2) the sandwich immunosensing method. In the sandwich assay mode, the second antibody 9F5 biologically amplified the sensor response. As a result, the sandwich assay showed a sensitivity of 0.25 microg/L and a detection range of 0.5 to 20 microg/L with within-run variation of 4.9 to 6.7% and between-run variation of 5.2 to 8.4%. This method has greatly enhanced the sensitivity for detection compared to that previously reported in the literatures.  相似文献   

12.
A disposable amperometric immunosensor was studied for the rapid detection of carp (Carassius auratus) Vitellogenin (Vtg). The sensor was fabricated based on screen-printed carbon arrays (SPCAs) containing eight carbon working and an integrated carbon counter electrodes. To construct the sensor, a conducting polymer (poly-terthiophene carboxylic acid) was electropolymerized on the surface of working electrodes and the polymer-coated SPCAs was characterized by SEM. Horseradish peroxidase (HRP) and a monoclonal antibody (anti-Vtg) specific to carp Vtg were covalently attached onto the polymer modified SPCAs. The immobilization of HRP and anti-Vtg onto the polymer-coated SPCAs was examined using cyclic voltammetry and quartz crystal microbalance studies. In order to detect the amount of Vtg, glucose oxidase (GOx)-labelled Vtg bound to the sensor surface under competition with the Vtg analyte was quantified amperometrically using glucose as a substrate. The performance of the eight sensors in arrays was evaluated by obtaining the calibration plots for Vtg. The sensor arrays exhibit a linear range of the Vtg concentration from 0.25 to 7.8 ng/ml and the detection limit was determined to be 0.09 ng/ml. Furthermore, the performance of the immunosensor for the determination of Vtg was evaluated by a standard addition method performed in fish serum samples.  相似文献   

13.
The determination of antigliadin antibodies from human serum samples is of vital importance for the diagnosis of an autoimmune disease such as celiac disease. An electrochemical immunosensor that mimics traditional ELISA type architecture has been constructed for the detection of antigliadin antibodies with control over the orientation and packing of gliadin antigen molecules on the surface of gold electrodes. The orientation of the antigen on the surface has been achieved using a carboxylic-ended bipodal alkanethiol that is covalently linked with amino groups of the antigen protein. The bipodal thiol presents a long poly(ethyleneglycol)-modified chain that acts as an excellent non-specific adsorption barrier. The bipodal nature of the thiol ensured a good spacing and hence good diffusion properties of electroactive species through the self-assembled monolayer, which is vital for the efficiency of the constructed electrochemical immunosensor. The electrochemical immunosensor was characterized using surface plasmon resonance as well as electrochemical impedance spectroscopy. Amperometric evaluation of the sensor with polyclonal antigliadin antibodies showed stable and reproducible low limits of detection (46 ng/mL; % RSD = 8.2, n = 5). The behaviour and performance of the electrochemical immunosensor with more complex matrixes such as reference serum solutions and real patient samples was evaluated and compared with commercial ELISA kits demonstrating an excellent degree of correlation in thirty minutes total assay time; the electrochemical immunosensor not only delivers a positive or negative result, it allows the estimation of semi-quantitative antibody contents based on the comparison against clinical reference solutions.  相似文献   

14.
A surface plasmon resonance (SPR)-immunosensor for detection of benzo[a]pyrene (BaP) is developed by using a model BaP-hapten compound, BaP-bovine serum albumin conjugate (BaP-BSA), and an anti-BaP-BSA monoclonal antibody. BaP-BSA conjugate is immobilized on a gold thin-film sensor chip by means of simple physical adsorption. The number of BaP-hapten units in BaP-BSA conjugate is estimated to be 28 from the difference in molecular weight (MW) between BaP-BSA conjugate and BSA based on the results of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) measurement. Anti-BaP-BSA antibody on contact with the BaP-BSA conjugate immobilized sensor chip causes an increase in the incident angle of the sensor chip. Binding of anti-BaP-BSA antibody with surface-immobilized BaP-BSA conjugate is inhibited by the presence of BaP in analyte solution, because of the inhibition effect of BaP. The SPR immunosensor for BaP functioning with the indirect competitive immunoreaction of anti-BaP-BSA antibody between the analyte (BaP) in testing solution and the BaP-BSA conjugate immobilized on the sensor chip provides a rapid determination (response time: ca. 15 min) of BaP in the concentration range of 0.01-1000 ppb. The antibody anchored to the sensor chip by antigen-antibody binding is removed on treatment with a pepsin solution (pH 2.0) for few minutes. The SPR sensor chip is found to be reusable for more than 20 times with a little decrease (<7%) in the sensor response. Detection of BaP by direct competitive immunoreactions is also carried out by enzyme-linked immunosorbent assay (ELISA). The concentration of BaP could be determined as low as 0.01 ppb and 2 ppb using the SPR sensor and the ELISA method, respectively. The SPR sensor is found to detect BaP selectively in the presence of 2-hydroxybiphenyl (HBP); the incident angle shift of the SPR sensor for BaP is found to be same irrespective to the presence or the absence of a same concentration (as much as 30 ppb) of HBP together.  相似文献   

15.
A direct, rapid, and label-free electrochemical immunoassay method for testosterone has been described based on encapsulating testosterone antibody into polyvinyl butyral sol–gel film doped with gold nanowires. Gold nanowires prepared by using nanopore polycarbonate membrane were used to conjugate testosterone antibody onto the probe surface. The presence of gold nanowires provided a biocompatible microenvironment for biomolecules, greatly amplified the immobilized amount of biomolecules on the electrode surface, and improved the sensitivity of the immunosensor. In comparison with gold nanoparticle-conjugating probe, the gold nanowire-functionalized probe could avoid the leakage of biomolecules from the composite film, and enhanced the stability of the sensor. The performance and factors influencing the performance of the resulting immunosensor were investigated in detail. Under optimal conditions, the developed immunosensor exhibited a good linear relationship with testosterone ranging from 1.2 to 83.5 ng mL− 1 with a detection limit of 0.1 ng mL− 1 (at 3δ). Moreover, the proposed immunosensor exhibited high sensitivity, good reproducibility and long-term stability. The as-prepared immunosensors were used to analyze testosterone in human serum specimens. Analytical results suggest that the developed immunoassay has a promising alternative approach for detecting testosterone in the clinical diagnosis. Compared with the conventional ELISAs, the proposed immunoassay method was simple and rapid without multiple labeling and separation steps. Importantly, the route provides an alternative approach to incorporate gold nanowires into the solid matrix for biosensing application.  相似文献   

16.
An immunosensor based on surface plasmon resonance (SPR) with enhanced performance was developed through a mixed self-assembled monolayer. A mixture of 16- mercaptohexadecanic acid (16-MHA) and 1-undecanethiol with various molar ratios was self-assembled on gold (Au) surface and the carboxylic acid groups of 16-MHA were then coordinated to Zn ions by exposing the substrate to an ethanolic solution of Zn(NO(3))(2)d6H2O. The antibody was immobilized on the SPR surface by exposing the functionalized substrate to the desired solution of antibody in phosphatebuffered saline (PBS) molecules. The film formation in series was confirmed by SPR and atomic force microscopy (AFM). The functionalized surface was applied to develop an SPR immunosensor for detecting human serum albumin (HSA) and the estimated detection limit (DL) was 4.27 nM. The limit value concentration can be well measured between ill and healthy conditions.  相似文献   

17.
In this work we present the development of a multi-analyte immunosensor for the determination of follitropin, human chorionic gonadotropin and prolactin in human serum. The immunosensor is based on plastic capillaries. According to the methodology, discrete areas of the internal capillary surface are coated with different antibodies, which are highly specific for each one of the analytes to be determined. The sample that will be analyzed along with a mixture of analyte-specific biotinylated antibodies is introduced into the capillary. The coated and the detection antibodies react with different epitopes of the analytes in the sample to form a 'sandwich'. The detection is based on reaction of the immobilized biotinylated antibody with streptavidin labeled with R-phycoerythrin. The fluorescent areas formed were quantified by scanning the capillary with a light beam of appropriate wavelength. A light sensor placed at the end of the capillary detects the emitted photons, that are trapped and waveguided into the capillary walls. The multi-analyte immunosensor assays were characterized by high specificity and short analysis time. In addition, the results obtained by the multi-analyte optical capillary immunosensor were comparable to those obtained by immunofluorimetric assays performed in microtitration wells. Potential applications of the proposed immunosensor include determination of several analyte panels in a broad spectrum of disciplines such as endocrinology, hematology, and oncology.  相似文献   

18.
We have examined the sensing characteristics of a surface plasmon resonance (SPR) immunoassay for the detection of 2,4,6-trinitrotoluene (TNT) using an immunoreaction between 2,4,6-trinitrophenol-ovalbumin (TNP-OVA) conjugate and anti-2,4,6-trinitrophenol antibody (anti-TNP antibody). TNP-OVA conjugate was attached to a SPR-gold sensing surface by means of physical immobilization, which undergoes binding interaction with anti-TNP antibody. Both the immobilization and binding processes were studied from a change in the SPR-resonance angle. The quantification of TNT is based on the principle of indirect competitive immunoassay, in which the immunoreaction between the TNP-OVA conjugate and anti-TNP antibody was inhibited in the presence of free TNT in solution. The decrease in the resonance angle shift is proportional to an increase in concentration of TNT used for incubation. The immunoassay exhibited excellent sensitivity for the detection of TNT in the concentration range from 0.09 to 1000 ng/ml with good stability and reproducibility. The immunosensor developed could detect TNT as low as 0.09 ng/ml, within a response time of approximately 22 min. The sensor surface was regenerated by a brief flow of pepsin solution, which disrupts the antigen-antibody complex without destroying the conjugate biofilm. Cross-reactivity of the SPR sensor to some structurally related nitroaromatic derivative and the detection of TNT in the presence of these nitroaromatic compounds were investigated. The cross-reactivity of the SPR sensor to 2,4-dinitrotoluene (2,4-DNT), 1,3-dinitrobenzene (1,3-DNB), 2-amino-4,6-dinitrotoluene (2A-4,6-DNT) and 4-amino-2,6-dinitrotoluene (4A-2,6-DNT) were very low (< or =1.1%). The analytical characteristics of the proposed immunosensor are highly promising for the development of new field-portable sensors for on-site detection of landmines.  相似文献   

19.
Fiber-optic immunosensor for mycotoxins   总被引:1,自引:0,他引:1  
Evanescent wave-based fiber-optic immunosensors were studied for the detection of fumonisins and aflatoxins in maize. Two formats, competitive and non-competitive, were used. A competitive format was used to measure fumonisin B1 (FB1) in both spiked and naturally contaminated maize samples. Fumonisin monoclonal antibodies were covalently coupled to an optical fiber and the competition between FB1 and FB1 labeled with fluorescein (FB1-FITC) for the limited number of binding sites on the fiber was assessed. The signal generated in the assay was inversely proportional to the FB1 concentration. For samples, the concentration causing an inhibition of binding by 50% (IC50) was dependent upon the clean-up procedure used. Simple dilution of methanolic maize extracts yielded an assay with an IC50 equivalent to 25 microg FB1 g(-1) maize with a limit of detection of 3.2 microg g(-1) maize. Affinity column clean-up yielded an assay with an IC50 equivalent to 5 microg FB1 g(-1) maize (limit of detection 0.4 microg FB1 g(-1)). An HPLC method and the immunosensor method agreed well for naturally contaminated maize samples except when large amounts of other fumonisins that cross-react with the immunosensor were present. The second sensor format, for the mycotoxin aflatoxin B1 (AFB1), was a non-competitive assay using the native fluorescence of this mycotoxin. Because the fluorescence of AFB1 itself was detected, the response of the sensor was directly proportional to the toxin concentration. The sensor, while capable of detecting as little as 2 ng ml(-1) of AFB1 in solution was technically not an immunosensor, since the attachment of aflatoxin specific antibodies was not required. Sensors of the formats described have the potential to rapidly screen individual maize samples but require coupling with a clean-up technique to be truly effective.  相似文献   

20.
In this study, a CdSe/ZnS quantum dot (QD)-based immunosensor using a simple optical system for human serum albumin (HSA) detection is developed. Monoclonal anti-HSA (AHSA) immobilized on 3-aminopropyltriethoxysilane (APTES)-modified glass was used to capture HSA specifically. Bovine serum albumin (BSA) was used to block non-specific sites. The solution, containing AHSA-QD complex prepared by mixing biotinylated polyclonal anti-HSA and streptavidin coated QD, was used to conjugate with the HSA molecules captured on AHSA/BSA/APTES-modified glass for the modification of HSA with QD. A simple optical system, comprising a diode laser (405 nm), an optical lens, a 515-nm-long pass filter, and an Si-photodiode, was used to detect fluorescence and convert it to photocurrent. The current intensity was determined by the amount of QD specifically conjugated with HSA, and was therefore HSA-concentration-dependent and could be used to quantify HSA concentration. The detection limit of the pure QD solution was ~3.5×10(-12) M, and the detection limit for the CdSe/ZnS QD-based immunosensor developed in this study was approximately 3.2×10(-5) mg/ml. This small optical biosensing system shows considerable potential for future applications of on-chip liver-function detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号