首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The adoption of disposable bioreactor technology as an alternate to traditional nondisposable technology is gaining momentum in the biotechnology industry. Evaluation of current disposable bioreactors systems to sustain high intensity fed-batch mammalian cell culture processes needs to be explored. In this study, an assessment was performed comparing single-use bioreactors (SUBs) systems of 50-, 250-, and 1,000-L operating scales with traditional stainless steel (SS) and glass vessels using four distinct mammalian cell culture processes. This comparison focuses on expansion and production stage performance. The SUB performance was evaluated based on three main areas: operability, process scalability, and process performance. The process performance and operability aspects were assessed over time and product quality performance was compared at the day of harvest. Expansion stage results showed disposable bioreactors mirror traditional bioreactors in terms of cellular growth and metabolism. Set-up and disposal times were dramatically reduced using the SUB systems when compared with traditional systems. Production stage runs for both Chinese hamster ovary and NS0 cell lines in the SUB system were able to model SS bioreactors runs at 100-, 200-, 2,000-, and 15,000-L scales. A single 1,000-L SUB run applying a high intensity fed-batch process was able to generate 7.5 kg of antibody with comparable product quality.  相似文献   

2.
Dissolved carbon dioxide (dCO2) is a well-known critical parameter in bioprocesses due to its significant impact on cell metabolism and on product quality attributes. Processes run at small-scale faces many challenges due to limited options for modular sensors for online monitoring and control. Traditional sensors are bulky, costly, and invasive in nature and do not fit in small-scale systems. In this study, we present the implementation of a novel, rate-based technique for real-time monitoring of dCO2 in bioprocesses. A silicone sampling probe that allows the diffusion of CO2 through its wall was inserted inside a shake flask/bioreactor and then flushed with air to remove the CO2 that had diffused into the probe from the culture broth (sensor was calibrated using air as zero-point calibration). The gas inside the probe was then allowed to recirculate through gas-impermeable tubing to a CO2 monitor. We have shown that by measuring the initial diffusion rate of CO2 into the sampling probe we were able to determine the partial pressure of the dCO2 in the culture. This technique can be readily automated, and measurements can be made in minutes. Demonstration experiments conducted with baker's yeast and Yarrowia lipolytica yeast cells in both shake flasks and mini bioreactors showed that it can monitor dCO2 in real-time. Using the proposed sensor, we successfully implemented a dCO2-based control scheme, which resulted in significant improvement in process performance.  相似文献   

3.
Single use bioreactors provide an attractive alternative to traditional deep-tank stainless steel bioreactors in process development and more recently manufacturing process. Wave bag bioreactors, in particular, have shown potential applications for cultivation of shear sensitive human and animal cells. However, the lack of knowledge about the complex fluid flow environment prevailing in wave bag bioreactors has so far hampered the development of a scientific rationale for their scale up. In this study, we use computational fluid dynamics (CFD) to investigate the details of the flow field in a 20-L wave bag bioreactor as a function of rocking angle and rocking speed. The results are presented in terms of local and mean velocities, mixing, and energy dissipation rates, which are used to create a process engineering framework for the scale-up of wave bag bioreactors. Proof-of-concept analysis of mixing and fluid flow in the 20-L wave bag bioreactor demonstrates the applicability of the CFD methodology and the temporal and spatial energy dissipation rates integrated and averaged over the liquid volume in the bag provide the means to correlate experimental volumetric oxygen transfer rates (kLa) data with power per unit volume. This correlation could be used as a rule of thumb for scaling up and down the wave bag bioreactors.  相似文献   

4.

Background

Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation.

Results

A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham’s π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures.

Conclusion

The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/? 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale.
  相似文献   

5.
This case study focuses on the scale-up of a Sp2/0 mouse myeloma cell line based fed-batch bioreactor process, from the initial 3-L bench scale to the 2,500-L scale. A stepwise scale-up strategy that involved several intermediate steps in increasing the bioreactor volume was adopted to minimize the risks associated with scale-up processes. Careful selection of several available mixing models from literature, and appropriately applying the calculated results to our settings, resulted in successful scale-up of agitation speed for the large bioreactors. Consideration was also given to scale-up of the nutrient feeding, inoculation, and the set-points of operational parameters such as temperature, pH, dissolved oxygen, dissolved carbon dioxide, and aeration in an integrated manner. It has been demonstrated through the qualitative and the quantitative side-by-side comparison of bioreactor performance as well as through a panel of biochemical characterization tests that the comparability of the process and the product was well controlled and maintained during the process scale-up. The 2,500-L process is currently in use for the routine clinical production of Epratuzumab in support of two global Phase III clinical trials in patients with lupus. Today, the 2,500 L, fed-batch production process for Epratuzumab has met all scheduled batch releases, and the quality of the antibody is consistent and reproducible, meeting all specifications, thus confirming the robustness of the process.  相似文献   

6.
Demands for development of biological therapies is rapidly increasing, as is the drive to reduce time to patient. In order to speed up development, the disposable Automated Microscale Bioreactor (Ambr 250) system is increasingly gaining interest due to its advantages, including highly automated control, high throughput capacity, and short turnaround time. Traditional early stage upstream process development conducted in 2 ‐ 5 L bench‐top bioreactors requires high foot‐print, and running cost. The establishment of the Ambr 250 as a scale‐down model leads to many benefits in process development. In this study, a comprehensive characterization of mass transfer coefficient (kLa) in the Ambr 250 was conducted to define optimal operational conditions. Scale‐down approaches, including dimensionless volumetric flow rate (vvm), power per unit volume (P/V) and kLa have been evaluated using different cell lines. This study demonstrates that the Ambr 250 generated comparable profiles of cell growth and protein production, as seen at 5‐L and 1000‐L bioreactor scales, when using kLa as a scale‐down parameter. In addition to mimicking processes at large scales, the suitability of the Ambr 250 as a tool for clone selection, which is traditionally conducted in bench‐top bioreactors, was investigated. Data show that cell growth, productivity, metabolite profiles, and product qualities of material generated using the Ambr 250 were comparable to those from 5‐L bioreactors. Therefore, Ambr 250 can be used for clone selection and process development as a replacement for traditional bench‐top bioreactors minimizing resource utilization during the early stages of development in the biopharmaceutical industry. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:478–489, 2017  相似文献   

7.
Naringinase bioprocess based on Bacillus methylotrophicus was successfully scaled up based on constant oxygen transfer rate (OTR) as the scale-up criterion from 5-L bioreactor to 20-L bioreactor. OTR was measured in 5 and 20-L bioreactor under various operating conditions using dynamic method. The operating conditions, where complete dispersion was observed were identified. The highest OTR of 0.035 and 0.04?mMol/L/s was observed in 5 and 20-L bioreactor, respectively. Critical dissolved oxygen concentration of novel isolated strain B. methylotrophicus was found to be 20% of oxygen saturation in optimized medium. The B. methylotrophicus cells grown on sucrose had maximum oxygen uptake rate of 0.14?mMol/L/s in optimized growth medium. The cells produced the maximum naringinase activity of 751 and 778?U/L at 34?hr in 5 and 20-L bioreactors, respectively. The maximum specific growth rate of about 0.178/hr was observed at both the scales of operations. The maximum naringinase yield of 160 and 164?U/g biomass was observed in 5 and 20-L bioreactors, respectively. The growth and production profiles at both scales were similar indicating successful scale-up strategy for B. methylotrophicus culture.  相似文献   

8.
pH control is critical in bioreactor operations, typically realized through a two-sided control loop, where CO2 sparging and base addition are used in bicarbonate-buffered media. Though a common approach, base addition could compromise culture performance due to the potential impact from pH excursions and osmolality increase in large-scale bioreactors. In this study, the feasibility of utilizing control of sparge gas composition as part of the pH control loop was assessed in Chinese hamster ovary (CHO) fed-batch cultures. Fine pH control was evaluated in multiple processes at different setpoints in small-scale ambr®250 bioreactors. Desired culture pH setpoints were successfully maintained via air sparge feedback control. As part of the pH control loop, air sparging was increased to improve CO2 removal automatically, hence increase culture pH, and vice versa. The effectiveness of this pH control strategy was seamlessly transferred from ambr®250 to 200 L scale, demonstrating scalability of the proposed methodology. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 35: e2743, 2019  相似文献   

9.
In this study, we perform mass transfer characterization (kLa) on a novel mechanically driven/stirred Process Scouting Device, PSD, (SuperSpinner D 1000®, SSD) and demonstrate that this novel device can be viewed as disposable bioreactor. Using patch‐based optical sensors, we were able to monitor critical cell culture environmental conditions such as dissolved oxygen (DO) and pH in SSD for comparison to a 1 L standard spinner (SS) flask. We also coupled these mass transfer studies with mixing time studies where we observed relative high mixing times (5.2 min) that are typically observed in production scale bioreactors. Decreasing the mixing time 3.5‐fold resulted in 30% increase in kLa (from 2.3 to 3.0 h?1) and minimum DO level increased from 0% to 20% for our model hybridoma cell line. Finally, maximum viable cell density and protein titer stayed within ±20% of historical data, from our standard 5 L stirred bioreactor (Biostat®) operated under active DO control. Biotechnol. Bioeng. 2012; 109: 2790–2797. © 2012 Wiley Periodicals, Inc.  相似文献   

10.
Recombinant Cupriavidus necator H 16 with a novel metabolic pathway using a cobalamin-dependent mutase was exploited to produce 2-hydroxyisobutyric acid (2-HIBA) from renewable resources through microbial fermentation. 2-HIBA production capacities of different strains of C. necator H 16 deficient in the PHB synthase gene and genetically engineered to enable the production of 2-HIBA from the intracellular PHB precursor (R)-3-hydroxybutyryl-CoA were evaluated in 48 parallel milliliter-scale stirred tank bioreactors (V = 11 mL). The effects of media composition, limitations, pH, and feed rate were studied with respect to the overall process performances of the different recombinant strains. 2-HIBA production was at a maximum at nitrogen limiting conditions and if the pH was controlled between 6.8 and 7.2 under fed-batch operating conditions (intermittent fructose addition). The final concentration of 2-HIBA was 7.4 g L−1 on a milliliter scale. Best reaction conditions identified on the milliliter scale were transferred to a laboratory-scale fed-batch process in a stirred tank bioreactor (V = 2 L). Two different process modes for the production of 2-HIBA, a single-phase and a dual-phase fermentation procedure, were evaluated and compared on a liter scale. The final concentration of 2-HIBA was 6.4 g L−1 on a liter scale after 2 days of cultivation.  相似文献   

11.
High cell density cultivation of Haematococcus pluvialis for astaxanthin production was carried out in batch and fed-batch modes in 3.7-L bioreactors with stepwise increased light intensity control mode. A high cell density of 2.65 g L−1 (batch culture) or 2.74 g L−1 (fed-batch culture) was obtained, and total astaxanthin production in the fed-batch culture (64.36 mg L−1) was about 20.5% higher than in the batch culture (53.43 mg L−1). An unstructured kinetic model to describe the microalga culture system including cell growth, astaxanthin formation, as well as sodium acetate consumption was proposed. Good agreement was found between the model predictions and experimental data. The models demonstrated that the optimal light intensity for mixotrophic growth of H. pluvialis in batch or fed-batch cultures in a 3.7-L bioreactor was 90–360 μmol m−2 s−1, and that the stepwise increased light intensity mode could be replaced by a constant light intensity mode. Received 24 December 1998/ Accepted in revised form 23 April 1999  相似文献   

12.
Optimization of a bioreactor design can be an especially challenging process. For instance, testing different bioreactor vessel geometries and different impeller and sparger types, locations, and dimensions can lead to an exceedingly large number of configurations and necessary experiments. Computational fluid dynamics (CFD), therefore, has been widely used to model multiphase flow in stirred-tank bioreactors to minimize the number of optimization experiments. In this study, a multiphase CFD model with population balance equations are used to model gas–liquid mixing, as well as gas bubble distribution, in a 50 L single-use bioreactor vessel. The vessel is the larger chamber in an early prototype of a multichamber bioreactor for mammalian cell culture. The model results are validated with oxygen mass transfer coefficient (kLa) measurements within the prototype. The validated model is projected to predict the effect of using ring or pipe spargers of different sizes and the effect of varying the impeller diameter on kLa. The simulations show that ring spargers result in a superior kLa compared to pipe spargers, with an optimum sparger-to-impeller diameter ratio of 0.8. In addition, larger impellers are shown to improve kLa. A correlation of kLa is presented as a function of both the reactor geometry (i.e., sparger-to-impeller diameter ratio and impeller-to-vessel diameter ratio) and operating conditions (i.e., Reynolds number and gas flow rate). The resulting correlation can be used to predict kLa in a bioreactor and to optimize its design, geometry, and operating conditions.  相似文献   

13.
14.
During the past decade, novel disposable cell culture vessels (generally referred to as Process Scouting Devices or PSDs) have become increasingly popular for laboratory scale studies and seed culture generation. However, the lack of engineering characterization and online monitoring tools for PSDs makes it difficult to elucidate their oxygen transfer capabilities. In this study, a mass transfer characterization (kLa) of sensor enabled static and rocking T‐flasks is presented and compared with other non‐instrumented PSDs such as CultiFlask 50®, spinner flasks, and SuperSpinner D 1000®. We have also developed a mass transfer empirical correlation that accounts for the contribution of convection and diffusion to the volumetric mass transfer coefficient (kLa) in rocking T‐flasks. We also carried out a scale‐down study at matched kLa between a rocking T75‐flask and a 10 L (2 L filling volume) wave bioreactor (Cultibag®) and we observed similar DO and pH profiles as well as maximum cell density and protein titer. However, in this scale‐down study, we also observed a negative correlation between cell growth and protein productivity between the rocking T‐flask and the wave bioreactor. We hypothesize that this negative correlation can be due to hydrodynamic stress difference between the rocking T‐flask and the Cultibag. As both cell culture devices share key similarities such as type of agitation (i.e., rocking), oxygen transfer capabilities (i.e., kLa) and disposability, we argue that rocking T‐flasks can be readily integrated with wave bioreactors, making the transition from research‐scale to manufacturing‐scale a seamless process. Biotechnol. Bioeng. 2012;109: 2295–2305. © 2012 Wiley Periodicals, Inc.  相似文献   

15.
Process intensification has been widely used for many years in the mammalian biomanufacturing industry to increase productivity, agility and flexibility while reducing production costs. The most commonly used intensified processes are operated using a perfusion or fed-batch seed bioreactor enabling a higher than usual seeding density in the fed-batch production bioreactor. Hence, as part of the growth phase is shifted to the seed bioreactor, there is a lower split ratio, which increases the criticality of the seed bioreactor and could impact production performance. Therefore, such intensified processes should be designed and characterized for robust process scale-up. This research work is focused on intensified processes with high seeding density inoculated from seed bioreactor in fed-batch mode. The impact of the feeding strategy and specific power input (P/V) in the seed bioreactor and on the production step with two different cell lines (CL1 and CL2) producing two different monoclonal antibodies was investigated. Cell culture performance in the production bioreactor has been improved due to more stressful conditions for the cells in the seed bioreactor and the impact of the production bioreactor P/V on the production performance was limited. This is the first reported study highlighting a positive impact of cellular stress in seed bioreactors on intensified production bioreactor with the introduction of the “organized stress” concept.  相似文献   

16.
Phycocyanin production by high cell density cultivation of Spirulina platensis in batch and fed-batch modes in 3.7-L bioreactors with a programmed stepwise increase in light intensity program was investigated. The results showed that the cell density in fed-batch culture (10.2 g L−1) was 4.29-fold that in batch culture (2.38 g L−1), and the total phycocyanin production in the fed-batch culture (0.795 g L−1) was 3.05-fold that in the batch culture (0.261 g L−1). An unstructured kinetic model to describe the microalga culture system including cell growth, phycocyanin formation, as well as glucose consumption was proposed. The data fitted the models well (r 2 > 0.99). Furthermore, based on the kinetic models, the potential effects of light limitation and photoinhibition on cell growth and phycocyanin formation can be examined in depth. The models demonstrated that the optimal light intensity for mixotrophic growth of Spirulina platensis in batch or fed-batch cultures using a 3.7-L bioreactor was 80160 μE m−2 s−1, and the stepwise increase in light intensity can be replaced by a constant light intensity mode. Received 28 July 1998/ Accepted in revised form 8 October 1998  相似文献   

17.
Oxygen mass transfer was studied in conventional, bead mill and baffled roller bioreactors. Using central composite rotational design, impacts of size, rotation speed and working volume on the oxygen mass transfer were evaluated. Baffled roller bioreactor outperformed its conventional and bead mill counterparts, with the highest k L a obtained in these configurations being 0.58, 0.19, 0.41 min?1, respectively. Performances of the bead mill and baffled roller bioreactor were only comparable when a high bead loading (40 %) was applied. Regardless of configuration increase in rotation speed and decrease in working volume improved the oxygen mass transfer rate. Increase in size led to enhanced mass transfer and higher k L a in baffled roller bioreactor (0.49 min?1 for 2.2 L and 1.31 min?1 for 55 L bioreactors). Finally, the experimentally determined k L a in the baffled roller bioreactors of different sizes fit reasonably well to an empirical correlation describing the k L a in terms of dimensionless numbers.  相似文献   

18.
Bioreactors are the operative backbone, for example, for the production of biopharmaceuticals, biomaterials in tissue engineering, and sustainable substitutes for chemicals. Still, the Achilles' heel of bioreactors nowadays is the aeration which is based on intense stirring and gas sparging, yielding inherent drawbacks such as shear stress, foaming, and sterility concerns. We present the synergistic combination of simulations and experiments toward a membrane stirrer for the efficient bubble-free aeration of bioreactors. A digital twin of the bioreactor with an integrated membrane-module stirrer (MemStir) was developed with computational fluid dynamics (CFD) studies addressing the determination of fluid mixing, shear rates, and local oxygen concentration. Usability of the MemStir is shown in a foam-free recombinant production process of biosurfactants (rhamnolipids) from glucose with different strains of Pseudomonas putida KT2440 in a 3-L vessel and benchmarked against a regular aerated process. The MemStir delivered a maximal oxygen transfer rate (OTRmax) of 175 mmol L−1 h−1 in completely foam-free cultivations. With a high space-time yield (STY) of 118 mgRL L−1 h−1 during a fed-batch fermentation, the effectiveness of the novel MemStir is demonstrated. Simulations show the generic value of the MemStir beyond biosurfactant production, for example, for animal cell cultivation.  相似文献   

19.
《MABS-AUSTIN》2013,5(8):1502-1514
ABSTRACT

Although process intensification by continuous operation has been successfully applied in the chemical industry, the biopharmaceutical industry primarily uses fed-batch, rather than continuous or perfusion methods, to produce stable monoclonal antibodies (mAbs) from Chinese hamster ovary (CHO) cells. Conventional fed-batch bioreactors may start with an inoculation viable cell density (VCD) of ~0.5 × 106 cells/mL. Increasing the inoculation VCD in the fed-batch production bioreactor (referred to as N stage bioreactor) to 2–10 × 106 cells/mL by introducing perfusion operation or process intensification at the seed step (N-1 step) prior to the production bioreactor has recently been used because it increases manufacturing output by shortening cell culture production duration. In this study, we report that increasing the inoculation VCD significantly improved the final titer in fed-batch production within the same 14-day duration for 3 mAbs produced by 3 CHO GS cell lines. We also report that other non-perfusion methods at the N-1 step using either fed batch or batch mode with enriched culture medium can similarly achieve high N-1 final VCD of 22–34 × 106 cells/mL. These non-perfusion N-1 seeds supported inoculation of subsequent production fed-batch production bioreactors at increased inoculation VCD of 3–6 × 106 cells/mL, where these achieved titer and product quality attributes comparable to those inoculated using the perfusion N-1 seeds demonstrated in both 5-L bioreactors, as well as scaled up to 500-L and 1000-L N-stage bioreactors. To operate the N-1 step using batch mode, enrichment of the basal medium was critical at both the N-1 and subsequent intensified fed-batch production steps. The non-perfusion N-1 methodologies reported here are much simpler alternatives in operation for process development, process characterization, and large-scale commercial manufacturing compared to perfusion N-1 seeds that require perfusion equipment, as well as preparation and storage vessels to accommodate large volumes of perfusion media. Although only 3 stable mAbs produced by CHO cell cultures are used in this study, the basic principles of the non-perfusion N-1 seed strategies for shortening seed train and production culture duration or improving titer should be applicable to other protein production by different mammalian cells and other hosts at any scale biologics facilities.  相似文献   

20.
For multiple-use bench scale and larger bioreactors, sintered stainless steel frit spargers are commonly used as microspargers. For bench-scale single-use bioreactors (SUBs), existing microspargers are sintered plastics, such as polyethylene. However, though plastics are readily sterilized by irradiation making them convenient for single use, these designs overlook surface energy properties of the materials of construction. For these sintered plastic spargers, forces at the water-air-surface interface cause bubble coalescence, leading to lower effective mass transfer, higher gas flow rates, and differing pCO2 profiles in cell culture. Alternative materials of construction were evaluated based on contact angle information and bubble formation observations. Sintered glass was chosen over thermoplastic polymers for higher surface wettability as described in the glass/water contact angle, its history as a commonly sintered material, and availability at costs suitable for single use applications. Glass sintered spargers and traditional stainless steel frit spargers were compared by porosity, bubble size, and kLa studies. Mass transfer (kLa) and cell culture performance equal or greater than a standard 20 μm stainless steel microsparger mass transfer efficiency was achieved by a glass frit sparger, of international porosity standard “P40” according to ISO 4793-80, which corresponds to a range of 16–40 μm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号