首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Galantamine is an acetylcholinesterase inhibitor, recently approved for the treatment of mild-to-moderate Alzheimer's disease. To allow a higher throughput of samples, a new bioanalytical method for the determination of galantamine in human plasma was developed and validated. A stable isotope labelled internal standard was used. Sample preparation consisted of a simple one-step liquid-liquid extraction with toluene. The extracts were analysed with positive ion TurboIonspray tandem mass spectrometry (LC-MS-MS). The method was validated in the 1-500-ng/ml range. The accuracy, precision, selectivity, lower limit of quantification, upper limit of quantification, linearity and extraction recovery were evaluated, as well as the stability of the compound in plasma, blood, methanol and 2% BSA solutions under different conditions. The method proved very rugged during the analysis of large numbers of samples from clinical trials.  相似文献   

2.
Cromolyn sodium is a safe compound with potent anti-allergic properties when used locally or topically. Clinical data from systemic exposure is not available because of the poor GI absorption when given orally. In order to evaluate a new approach to enhance the absorption and bioavailability of cromolyn sodium, a sensitive assay was needed to support an oral-dose study in humans. This paper describes a liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method for the analysis of cromolyn sodium in human plasma. The method consists of a two-step extraction with subsequent analysis using a high-performance liquid chromatography electrospray tandem mass spectrometer system. The compounds were eluted isocratically on a C(18) column followed by a backflush. The total run time is 6 min. The standard curve of cromolyn sodium was over the range of 0.313 to 750 ng/mL with a lower limit of quantitation (LLOQ) of 0.313 ng/mL when 0.5 mL of plasma was used for analysis. The percent coefficient of variation (C.V.) for accuracy and precision (inter-assay and intra-assay) was less than 15% over the validated concentration range and the coefficients of determination, r(2), were >0.991577. The method is simple, sensitive, and selective, and has been successfully utilized for oral cromolyn sodium clinical studies.  相似文献   

3.
A method for the simultaneous determination of a cyclooxygenase-2 inhibitor, 4-(4-methanesulfonylphenyl)-3-phenyl-5H-furan-2-one (rofecoxib, I) and [13C7]rofecoxib, (II), in human plasma has been developed to support the clinical oral bioavailability (BA) study of I. The method is based on high-performance liquid chromatography (HPLC) with atmospheric pressure chemical ionization tandem mass spectrometric (APCI-MS-MS) detection in the negative ionization mode using a heated nebulizer interface. Two different stable isotope labeled analogs of I were initially evaluated for their use as intravenous (i.v.) markers in the BA study. [13CD3]Rofecoxib was shown to be isotopically unstable in plasma and water containing solvent and an efficient deuterium exchange prevented its use in the study. On the other hand, the isotopic integrity of the subsequently synthesized [13C7]rofecoxib (II) was maintained, as expected, in plasma and other solvent systems. The results of these experiments clearly demonstrated the need for the careful evaluation of the isotopic integrity of the stable isotope labeled compound for the successful utilization of these compounds in BA studies and also as internal standards in the quantitative analysis of drugs in biological fluids. After liquid-liquid extraction of I, II, and internal standard (III) from plasma, the analytes were chromatographed on a narrow bore (100 mm x 3.0 mm) C18 analytical column, with mobile phase consisting of acetonitrile-water (1:1, v/v) at a flow-rate of 0.5 ml/min. The MS-MS detection was performed on a PE Sciex API III Plus tandem mass spectrometer operated in the selected reaction monitoring mode. The precursor-->product ion combinations of m/z 313-->257, 320-->292, and 327-->271 were used to quantify I, II, and III, respectively. The assay was validated in the concentration range of 0.1 to 100 ng/ml of plasma for both I and II. The precision of the assay (expressed as relative standard deviation) was less than 10% at all concentrations within the standard curve range, with adequate assay accuracy. The assay was utilized to support the clinical BA study in which oral doses of I were administered together with an i.v. dose of II to determine the oral BA of rofecoxib at 12.5- and 25-mg doses.  相似文献   

4.
A sensitive and selective method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the quantitative determination of loperamide in human plasma. Automated solid-phase extraction (SPE) on disposable extraction cartridges (DEC) is used to isolate the compounds from the biological matrix and to prepare a cleaner sample before injection and analysis in the LC-MS/MS system. After conditioning, the plasma sample is loaded on the DEC filled with endcapped ethyl silica (C2(EC)) and washed twice with water. The analytes are therefore eluted by dispensing methanol. The eluate is then collected and added with ammonium acetate solution in order to inject an aliquot of this final extract in the LC-MS/MS system. On-line LC-MS/MS system using atmospheric pressure chemical ionization (APCI) has been developed for the determination of loperamide. The separation is obtained on a octadecylsilica based stationary phase using a mobile phase consisting in a mixture of methanol and 5mM ammonium acetate solution (25:75, v/v). Clonazepam is used as internal standard (IS). The MS/MS ion transitions monitored are m/z 477--> 266 and 316--> 270 for loperamide and clonazepam, respectively. The most appropriate regression model of the response function as well as the limit of quantitation were first selected during the pre-validation step. These latter criteria were then assessed during the formal validation step. The limit of quantitation (LOQ) was around 50 pg/ml for loperamide. The method was also validated with respect to recovery, precision, trueness, accuracy and linearity.  相似文献   

5.
A highly sensitive high-performance liquid chromatographic-tandem mass spectrometric method (HPLC-MS-MS) has been developed to quantitate clemastine in human plasma for the purpose of pharmacokinetic studies. Sample preparation was carried out by liquid-liquid extraction using deuterated clemastine as an internal standard. Chromatographic separation used a C18 reversed phase polymer column giving an extremely fast total run time of 2 min. The method was validated and used for the bioequivalence study of clemastine tablets in healthy male volunteers (n=28). The lower limit of detection proved to be 0.01 ng/ml for clemastine.  相似文献   

6.
Caffeic acid phenethyl ester (CAPE) is one of the most bioactive compounds of propolis, a resinous substance collected and elaborated by honeybees. A new liquid chromatography-electrospray ionisation tandem mass spectrometric method was developed and validated for its determination in rat plasma and urine, using taxifolin as internal standard. After sample preparation by liquid/liquid extraction with ethyl acetate, chromatographic separations were carried out with an ODS-RP column using a binary mobile phase gradient of acetonitrile in water. Detection was performed using a turboionspray source operated in negative ion mode and by multiple reaction monitoring. The method was validated, showing good selectivity, sensitivity (LOD = 1 ng/ml), linearity (5-1000 ng/ml; r > or = 0.9968), intra- and inter-batch precision and accuracy (< or =14.5%), and recoveries (94-106%) in both plasma and urine. Stability assays have shown that CAPE is rapidly hydrolysed by plasmatic esterases, which are however inhibited by sodium fluoride. The method was applied to the determination of CAPE levels in rat plasma and urine after oral administration, showing that CAPE is rapidly absorbed and excreted in urine both as unmodified molecule and as glucuronide conjugate.  相似文献   

7.
A bioanalytical method for the analysis of oseltamivir (OP) and its metabolite oseltamivir carboxylate (OC) in human plasma, saliva and urine using off-line solid-phase extraction and liquid chromatography coupled to positive tandem mass spectroscopy has been developed and validated. OP and OC were analysed on a ZIC-HILIC column (50 mm x 2.1 mm) using a mobile phase gradient containing acetonitrile-ammonium acetate buffer (pH 3.5; 10mM) at a flow rate of 500 microL/min. The method was validated according to published FDA guidelines and showed excellent performance. The lower limit of quantification for OP was determined to be 1, 1 and 5 ng/mL for plasma, saliva and urine, respectively and for OC was 10, 10 and 30 ng/mL for plasma, saliva and urine, respectively. The upper limit of quantification for OP was determined to be 600, 300 and 1500 ng/mL for plasma, saliva and urine, respectively and for OC was 10,000, 10,000 and 30,000 ng/mL for plasma, saliva and urine, respectively. The within-day and between-day precisions expressed as R.S.D., were lower than 5% at all tested concentrations for all matrices and below 12% at the lower limit of quantification. Validation of over-curve samples ensured that it would be possible with dilution if samples went outside the calibration range. Matrix effects were thoroughly evaluated both graphically and quantitatively. No matrix effects were detected for OP or OC in plasma or saliva. Residues from the urine matrix (most likely salts) caused some ion suppression for both OP and its deuterated internal standard but had no effect on OC or its deuterated internal standard. The suppression did not affect the quantification of OP.  相似文献   

8.
A bioanalytical method for the analysis of artesunate and its metabolite dihydroartemisinin in human plasma using high throughput solid-phase extraction in the 96-wellplate format and liquid chromatography coupled to positive tandem mass spectroscopy has been developed and validated. The method was validated according to published FDA guidelines and showed excellent performance. The within-day and between-day precisions expressed as RSD, were lower than 7% at all tested concentrations including the lower limit of quantification. Using 50 microl plasma the calibration range was 1.19-728 ng/ml with a limit of detection at 0.5 ng/ml for artesunate and 1.96-2500 ng/ml with a limit of detection at 0.6 ng/ml for dihydroartemisinin. Using 250 microl of plasma sample the lower limit of quantification was decreased to 0.119 ng/ml for artesunate and 0.196 ng/ml dihydroartemisinin. Validation of over-curve samples in plasma ensured that accurate estimation would be possible with dilution if samples went outside the calibration range. The method was free from matrix effects as demonstrated both graphically and quantitatively.  相似文献   

9.
A sensitive and selective LC-MS-MS method for the isolation and quantification of alpha-methyltyrosine (AMT) from human plasma is described. The method employs a simple protein precipitation using zinc sulfate and sodium hydroxide. This precipitation procedure produced samples with high aqueous content that could be directly injected into a LC-MS-MS system without compromising reverse-phase chromatographic performance. Chromatographic separation was performed on a MetaChem MonoChrom C(18) column (2.0 mm x 50 mm; 5 microm) at a flow rate of 1 mL/min. Compounds were eluted using a gradient mixture of water-acetic acid (100:0.1, v/v) and acetonitrile-acetic acid (100:0.1, v/v). The structural analog alpha-hydroxymethyltyrosine was used as the internal standard. Mass spectrometric detection was carried out with a triple quadrupole mass spectrometer. The method was validated and used to determine human plasma AMT concentrations, and has been implemented to derive pharmacokinetic parameters.  相似文献   

10.
A sensitive and specific liquid chromatographic-tandem mass spectrometric method is described for the determination of cefaclor in human plasma. The plasma samples were treated by two sample preparation procedures, i.e. protein precipitation (PPT) and solid-phase extraction (SPE). The pretreated samples were analyzed on a C(18) HPLC column interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization (ESI) was employed as the ionization source. The analyte and internal standard ampicillin (for PPT) or cefetamet (for SPE) were detected by use of selected reaction monitoring (SRM) mode. The lower limit of quantitation obtained as a result of the PPT procedure was 100 ng/ml. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 12% for cefaclor. The accuracy as determined from QC samples was within +/-3% for the analyte. The SPE procedure could provide the lower limit of quantitation of 2 ng/ml. The precision and accuracy were measured to be below 7.1% and between -3.6% and 1.1%, respectively, for all QC samples. The method was applied for the evaluation of the pharmacokinetic profiles of cefaclor sustained-release formulation.  相似文献   

11.
A stable-isotope-dilution HPLC-tandem mass spectrometry-based method was developed for the determination of dextromethorphan in human plasma. Plasma samples were prepared for analysis by solid-phase extraction on octadecylsilane extraction cartridges. Dextromethorphan and the deuterium-labeled dextromethorphan internal standard were chromatographed on a short reversed-phase column and detected by a selected-reaction-monitoring scheme. Linear standard curves were obtained over three orders of magnitude and the limit of quantitation for dextromethorphan was 50 pg/ml, using a 1-ml plasma sample. The combination of HPLC and electrospray tandem mass spectrometry resulted in a rapid, selective and sensitive method for the analysis of dextromethorphan in plasma. The method was applied for the evaluation of the pharmacokinetic profile of dextromethorphan in human volunteers following peroral administration.  相似文献   

12.
A sensitive bioanalytical method for the measurement of two major circulating metabolites of duloxetine [4-hydroxy duloxetine glucuronide (LY550408) and 5-hydroxy-6-methoxy duloxetine sulfate (LY581920)] in plasma is reported. This method produced acceptable precision and accuracy over the validation range of 1-1000 ng/mL. Several issues had to be addressed in order to develop an LC/MS/MS assay for these metabolites. First, 4-hydroxy duloxetine glucuronide required chromatographic resolution from the 5-, and 6-hydroxy duloxetine glucuronide isomers. Second, the glucuronide conjugate is readily ionized under positive ESI conditions, while the sulfate conjugate required negative ESI conditions to obtain adequate sensitivity. Finally, the chromatographic conditions needed to separate the glucuronide isomers were not suitable for the analysis of the sulfate conjugate. The present method addressed these challenges, and was successfully applied to multiple human pharmacokinetic studies in which subjects received oral doses of duloxetine hydrochloride.  相似文献   

13.
A method to determine sildenafil in human plasma involving liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed. Sildenafil and the internal standard (I.S.), diazepam, are extracted from human plasma with ether-dichloromethane (3:2, v/v) at basic pH and analyzed by reversed-phase high-performance liquid chromatography (HPLC) using methanol-10mM ammonium acetate pH 7.0 (85:15, v/v) as the mobile phase. Detection by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring mode was linear over the concentration range 0.125-40.0 ng/ml. Intra- and inter-day precision of the assay at four concentrations within this range were 2.5-8.0%. The method was used to evaluate plasma concentration-time profiles in healthy volunteers given an oral dose of 20mg sildenafil as a combination tablet also containing apomorphine.  相似文献   

14.
The balance between nitric oxide (NO) and vasoconstrictors like endothelin is essential for vascular tone and endothelial function. L-Arginine is converted to NO and L-citrulline by NO synthase (NOS). Asymmetric dimethylarginine (ADMA) and symmetric dimethylarginine (SDMA) are endogenous inhibitors of NO formation. ADMA is degraded by dimethylamino dimethylhydrolases (DDAHs), while SDMA is exclusively eliminated by the kidney. In the present article we report a LC-tandem MS method for the simultaneous determination of arginine, ADMA, and SDMA in plasma. This method is designed for high sample throughput of only 20-mul aliquots of human or mouse plasma. The analysis time is reduced to 1.6 min by LC-tandem MS electrospray ionisation (ESI) in the positive mode. The mean plasma levels of l-arginine, ADMA, and SDMA were 74+/-19 (SD), 0.46+/-0.09, and 0.37+/-0.07 microM in healthy humans (n=85), respectively, and 44+/-14, 0.72+/-0.23, and 0.19+/-0.06 microM in C57BL/6 mice. Also, the molar ratios of arginine to ADMA were different in man and mice, i.e. 166+/-50 and 85+/-22, respectively.  相似文献   

15.
Nitric oxide (NO), the endogenous modulator of vascular tone and structure, originates from oxidation of L-arginine catalysed by NO synthase (NOS). The L-arginine derivative L-homoarginine serves as an alternative NOS substrate releasing NO, competing with L-arginine for NOS, arginase, and arginine transport. In the present article we report a liquid chromatography-tandem mass spectrometric (LC-tandem MS) method for the determination of L-homoarginine in human plasma by stable-isotope dilution. L-[(13)C(6)]-Homoarginine was used as internal standard. This method provides high sample throughput of 25-μl aliquots of plasma with an analysis time of 4 min using LC-tandem MS electrospray ionisation in the positive mode (ESI+). Specific transitions for L-homoarginine and L-[(13)C(6)]-homoarginine were m/z 245 → m/z 211 and m/z 251 → m/z 217, respectively. The mean intra- and interassay CVs were 7.4 ± 4.5% (±SD) for 0.1-50 μmol/L and 7.5 ± 2.0% for 2 and 5 μmol/L, respectively. Applying this method, a mean plasma concentration of L-homoarginine of 2.5 ± 1.0 μmol/L was determined in 136 healthy humans.  相似文献   

16.
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of the prodrug fosinopril and its major active metabolite fosinoprilat for pharmacokinetic studies in healthy subjects. In order to get the lower limit of quantification (LLOQ), especially for analysis of fosinopril, key points of the method have been investigated including chromatographic conditions and selection of LC-MS/MS conditions. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a reversed-phase C(8) column using gradient procedure, and detected by tandem mass spectrometry with a triple quadrupole ionization interface. The analytes and internal standard zaleplon were detected using positive electrospray ionization (ESI) in the SRM mode. The LLOQ of the method down to 0.1 ng mL(-1) for fosinopril and 1.0 ng mL(-1) for fosinoprilat were identifiable and reproducible. The standard calibration curves for both fosinopril and fosinoprilat were linear over the ranges of 0.1-15.0 and 1.0-700 ng mL(-1) in human plasma, respectively. The within- and between-batch precisions (relative standard deviation (RSD)%) and the accuracy were acceptable. The validated method was successfully applied to reveal the pharmacokinetic properties of fosinopril and fosinoprilat after oral administration.  相似文献   

17.
A rapid and sensitive LC-MS-MS method for the determination of huperzine A in dog plasma using huperzine B as internal standard has been developed and validated. The analyte and internal standard were extracted from plasma using n-hexane-dichloromethane-2-propanol (300:150:15, v/v/v), chromatographed on a C(18) column (5 microm, 50 mm x 4.6 mm i.d.) with a mobile phase consisting of acetonitrile-methanol-10mM ammonium acetate (35:40:25, v/v/v), and detected using a tandem mass spectrometer with a TurboIonSpray ionization interface. The run time was only 2 min. The assay was linear over the concentration range 0.05-20 ng/ml and intra- and inter-day precision over this range were <5.3% with good accuracy. The limit of detection in plasma was 0.01 ng/ml. The method was successfully applied to define plasma concentration-time curves of huperzine A in dogs after the last dose of an intramuscular injection (10 microg/kg per day for 15 days) of a sustained-release formulation of huperzine A.  相似文献   

18.
A new on-line, rapid and sensitive column-switch LC/MS/MS method to measure nelfinavir (NFV), an HIV-1 protease inhibitor, and its major metabolite (M1) in rat plasma was developed. Rat plasma containing the analytes and the internal standard was treated with acetonitrile and the supernatant was processed through an on-line extraction and an analytical columns, with a column-switch device. ESI-LC/MS with multiple reaction monitors for appropriate analytes was performed. This assay gave a limit of quantitation (LOQ) of <1 ng/mL for the analytes with 5 min run time. The within-run and between-run precisions were <12 and <10%, respectively. This analytical method was successfully applied to a study to correlate changes in maternal and placental NFV plasma concentrations in rats following NFV exposure in utero.  相似文献   

19.
A liquid chromatographic–tandem mass spectrometric method for the rapid quantitative determination of pibutidine, an H2-receptor antagonist, in human urine has been developed and validated over the concentration range 0.1–25.6 μg ml−1. Urine samples were prepared based on a simple dilution with 0.05% acetic acid, followed by reversed-phase liquid chromatographic separation. Pibutidine and its internal standard (2H10-pibutidine) were ionized using an electrospray ionization interface and detected by tandem mass spectrometry in the selected reaction-monitoring mode. Completed validation demonstrated the method to be robust, accurate, precise and specific for the direct quantification of pibutidine in human urine. This method has enabled investigation of the urinary excretion of pibutidine following oral administration of pibutidine hydrochloride to healthy subjects.  相似文献   

20.
Ribavirin is a purine nucleoside analog with broad spectrum activity against a spectrum of DNA and RNA viruses. To facilitate pharmacokinetics studies, a LC-MS-MS method for the analysis of ribavirin in rat and monkey plasma was developed and validated. The method involved the addition of acyclovir as an internal standard and protein precipitation with acetonitrile followed by separation by an Intertsil Silica column and quantification by a MS-MS equipped with a positive electrospray ionization in the multiple reaction monitoring mode. The MS-MS reaction was selected to monitor the 245-->113 and 226-->152 transitions for ribavirin and internal standard, respectively. The calibration curve was linear over a concentration range of 10-5000 ng/ml. The lower limit of quantitation was 10 ng/ml, the coefficient of variation (CV) was 8-11%, and the bias was 1-3%. Intra-day and inter-day analysis of QC samples at 30, 1500 and 3500 ng/ml indicate that the method was precise (CV<18%) and accurate (bias<13%). Ribavirin in rat and monkey plasma was stable at 5 degrees C for at least 24 h, 0 degrees C for at least 4 h, and after three freeze-thaw cycles. This specific, accurate and precise assay is useful in the study of the pharmacokinetics of this compound.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号