首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hypertension, a risk factor for atherosclerosis, increases the uptake of low density lipoproteins (LDL) by the arterial wall. Our objective in this work was to use computational modeling to identify physical factors that could be partially responsible for this effect. Fluid flow and mass transfer patterns in the lumen and wall of an arterial model were computed in a coupled manner, replicating as closely as possible previous experimental studies in which LDL uptake into the artery wall was measured in straight, excised arterial segments. Under conditions of both flow and no-flow, simulations predicted an increase in concentration polarization of LDL at the artery wall when arterial pressure was increased from 120 to 160 mmHg. However, this led to only a slight increase in mean LDL concentration within the arterial wall. However, if the permeability of the endothelium to LDL was allowed to vary with intra-arterial pressure, then the simulations predicted that the uptake of LDL would be enhanced 1.9-2.6 fold at higher pressure. The magnitude of this increase was consistent with experimental data. We conclude that the concentration polarization effects, enhanced by elevated intra-arterial pressure, cannot explain the increase in LDL uptake seen under hypertensive conditions. Instead, the data are most consistent with a pressure-linked increase in endothelial permeability to LDL.  相似文献   

2.
Mechanical stimulation, in the form of fluid perfusion or mechanical strain, enhances osteogenic differentiation and overall bone tissue formation by mesenchymal stems cells cultured in biomaterial scaffolds for tissue engineering applications. In silico techniques can be used to predict the mechanical environment within biomaterial scaffolds, and also the relationship between bone tissue regeneration and mechanical stimulation, and thereby inform conditions for bone tissue engineering experiments. In this study, we investigated bone tissue regeneration in an idealised hydrogel scaffold using a mechano-regulation model capable of predicting tissue differentiation, and specifically compared five loading cases, based on known experimental bioreactor regimes. These models predicted that low levels of mechanical loading, i.e. compression (0.5% strain), pore pressure of 10 kPa and a combination of compression (0.5%) and pore pressure (10 kPa), could induce more osteogenic differentiation and lead to the formation of a higher bone tissue fraction. In contrast greater volumes of cartilage and fibrous tissue fractions were predicted under higher levels of mechanical loading (i.e. compression strain of 5.0% and pore pressure of 100 kPa). The findings in this study may provide important information regarding the appropriate mechanical stimulation for in vitro bone tissue engineering experiments.  相似文献   

3.
To quantitatively investigate the role of the endothelial glycocalyx layer (EGL) in protecting the artery from excessive infiltration of atherogenic lipids such as low density lipoproteins (LDLs), a multilayer model with the EGL of an arterial segment was developed to numerically simulate the flow and the transport of LDLs under normal and high pressure. The transport parameters of the layers of the model were obtained from the hydrodynamic theory, the stochastic theory, and from the literature. The results showed that the increase in the thickness of the EGL could lead to a sharp drop in LDL accumulation in the intima. A partial damage to the EGL could compromise its barrier function, hence leading to enhanced infiltration/accumulation of LDLs within the wall of the arterial model. Without the EGL, hypertension could lead to a significantly enhanced LDL transport into the wall of the model. However, the intact EGL could protect the arterial wall from hypertension so that the LDL concentration in the intima layer was almost the same as that under normal pressure conditions. The results also showed that LDL concentration within the arterial wall increased with Φ (the fraction of leaky junctions) on the intima layer. The increase in LDL concentration with Φ was much more dramatic for the model without the EGL. For instance, without the EGL, a Φ of 0.0005 could lead LDL concentration within the arterial wall to be even higher than that predicted for the EGL intact model with a Φ of 0.002. In conclusion, an intact EGL with a sufficient thickness may act as a barrier to LDL infiltration into the arterial wall and has the potential to suppress the hypertension-driven hike of LDL infiltration/accumulation in the arterial wall.  相似文献   

4.
The transport of macromolecules, such as low density lipoproteins (LDLs), across the artery wall and their accumulation in the wall is a key step in atherogenesis. Our objective was to model fluid flow within both the lumen and wall of a constricted, axisymmetric tube simulating a stenosed artery, and to then use this flow pattern to study LDL mass transport from the blood to the artery wall. Coupled analysis of lumenal blood flow and transmural fluid flow was achieved through the solution of Brinkman's model, which is an extension of the Navier-Stokes equations for porous media. This coupled approach offers advantages over traditional analyses of this problem, which have used possibly unrealistic boundary conditions at the blood-wall interface; instead, we prescribe a more natural pressure boundary condition at the adventitial vasa vasorum, and allow variations in wall permeability due to the occurrence of plaque. Numerical complications due to the convection dominated mass transport process (low LDL diffusivity) are handled by the streamline upwind/Petrov-Galerkin (SUPG) finite element method. This new fluid-plus-porous-wall method was implemented for conditions typical of LDL transport in a stenosed artery with a 75 percent area reduction (Peclet number=2 x 10(8)). The results show an elevated LDL concentration at the downstream side of the stenosis. For the higher Darcian wall permeability thought to occur in regions containing atheromatous lesions, this leads to an increased transendothelial LDL flux downstream of the stenosis. Increased transmural filtration in such regions, when coupled with a concentration-dependent endothelial permeability to LDL, could be an important contributor to LDL infiltration into the arterial wall. Experimental work is needed to confirm these results.  相似文献   

5.
The propagation of harmonic pressure waves through a Newtonian fluid contained within a thick-walled, viscoelastic tube is considered as a model of arterial blood flow. The fluid is assumed to be homogeneous and Newtonian, and its motion to be laminar and axisymmetric. The wall is assumed to be isotropic, incompressible, linear, and viscoelastic. It is also assumed that the motion is such that the convective acceleration is negligible. The motion of the fluid is described by the linearized form of the Navier-Stokes equations and the motion of the wall by classical elasticity theory. The frequency dependence of the wall mechanical properties are represented by a three parameter, relaxation-type model. Using boundary conditions describing the continuity of stress and velocity components in the fluid and the wall, explicit solutions for the system of equations of the model have been obtained. The longitudinal fluid impedance has been expressed in terms of frequency and the system parameters. The frequency equation has been solved and the propagation constant also expressed in terms of frequency and system parameters. The results indicate that the fluid impedance is smaller than predicted by the rigid tube model or by Womersley''s constrained elastic tube model. Also, the velocity of propagation is generally slower and the transmission per wavelength less than predicted by Womersley''s elastic tube model. The propagation constant is very sensitive to changes in the degree of wall viscoelasticity.  相似文献   

6.
In this study, we develop structured tree outflow boundary conditions for modelling the human carotid haemodynamics. The model geometry was reconstructed through computerised tomography scan. Unsteady-state computational fluid dynamic analyses were performed under different conditions using a commercial software package ADINA R&D, Inc., (Watertown, MA, USA) in order to assess the impact of the boundary conditions on the flow variables. In particular, the results showed that the peripheral vessels massively impact the pressure while the flow is relatively unaffected. As an example of application of these outflow conditions, an unsteady fluid-structure interaction (FSI) simulation was carried out and the dependence of the wall shear stress (WSS) on the arterial wall compliance in the carotid bifurcation was studied. In particular, a comparison between FSI and rigid-wall models was conducted. Results showed that the WSS distributions were substantially affected by the diameter variation of the arterial wall. In particular, even similar WSS distributions were found for both cases, and differences in the computed WSS values were also found.  相似文献   

7.
The accumulation of low-density lipoprotein (LDL) is recognized as one of the main contributors in atherogenesis. Mathematical models have been constructed to simulate mass transport in large arteries and the consequent lipid accumulation in the arterial wall. The objective of this study was to investigate the influences of wall shear stress and transmural pressure on LDL accumulation in the arterial wall by a multilayered, coupled lumen-wall model. The model employs the Navier-Stokes equations and Darcy's Law for fluid dynamics, convection-diffusion-reaction equations for mass balance, and Kedem-Katchalsky equations for interfacial coupling. To determine physiologically realistic model parameters, an optimization approach that searches optimal parameters based on experimental data was developed. Two sets of model parameters corresponding to different transmural pressures were found by the optimization approach using experimental data in the literature. Furthermore, a shear-dependent hydraulic conductivity relation reported previously was adopted. The integrated multilayered model was applied to an axisymmetric stenosis simulating an idealized, mildly stenosed coronary artery. The results show that low wall shear stress leads to focal LDL accumulation by weakening the convective clearance effect of transmural flow, whereas high transmural pressure, associated with hypertension, leads to global elevation of LDL concentration in the arterial wall by facilitating the passage of LDL through wall layers.  相似文献   

8.
A significant amount of evidence linking wall shear stress to neointimal hyperplasia has been reported in the literature. As a result, numerical and experimental models have been created to study the influence of stent design on wall shear stress. Traditionally, blood has been assumed to behave as a Newtonian fluid, but recently that assumption has been challenged. The use of a linear model; however, can reduce computational cost, and allow the use of Newtonian fluids (e.g., glycerine and water) instead of a blood analog fluid in an experimental setup. Therefore, it is of interest whether a linear model can be used to accurately predict the wall shear stress caused by a non-Newtonian fluid such as blood within a stented arterial segment. The present work compares the resulting wall shear stress obtained using two linear and one nonlinear model under the same flow waveform. All numerical models are fully three-dimensional, transient, and incorporate a realistic stent geometry. It is shown that traditional linear models (based on blood's lowest viscosity limit, 3.5 Pa s) underestimate the wall shear stress within a stented arterial segment, which can lead to an overestimation of the risk of restenosis. The second linear model, which uses a characteristic viscosity (based on an average strain rate, 4.7 Pa s), results in higher wall shear stress levels, but which are still substantially below those of the nonlinear model. It is therefore shown that nonlinear models result in more accurate predictions of wall shear stress within a stented arterial segment.  相似文献   

9.
The effects of hypobaric conditions on stable isotope and mineral element concentrations during the germination of mungbean [Vigna radiata (Linn.) Wilczek] were evaluated. Mungbean seeds were cultured in lower atmospheric pressure (60 kPa) and normal air pressure (101 kPa) conditions, respectively. Oxygen and carbon dioxide partial pressures were maintained at 21 and 0.04 kPa, respectively. At 60 kPa, the fresh weight (FW) and dry weight (DW) of plants significantly increased by 5.41 and 9.62%, respectively, compared to those at 101 kPa after culturing for 7 d. Twelve mineral elements were compared among three organs (leaf, stem, and root) from seedlings grown under hypobaric and normal atmospheric conditions. This showed that lower air pressure generally improved element accumulation in the plant. A significantly lower value of δ 13C was observed at 60 kPa compared to that at 101 kPa. In addition, a significant increase in δ 15N value was detected in three different organs of plants grown under 60 kPa. Our survey provides a foundation for future field and laboratory studies on the influence of air pressure on plants, particularly in terms of stable isotope and mineral elements.  相似文献   

10.
Abdominal aortic aneurysm (AAA) rupture is the clinical manifestation of an induced force exceeding the resistance provided by the strength of the arterial wall. This force is most frequently assumed to be the product of a uniform luminal pressure acting along the diseased wall. However fluid dynamics is a known contributor to the pathogenesis of AAAs, and the dynamic interaction of blood flow and the arterial wall represents the in vivo environment at the macro-scale. The primary objective of this investigation is to assess the significance of assuming an arbitrary estimated peak fluid pressure inside the aneurysm sac for the evaluation of AAA wall mechanics, as compared with the non-uniform pressure resulting from a coupled fluid–structure interaction (FSI) analysis. In addition, a finite element approach is utilised to estimate the effects of asymmetry and wall thickness on the wall stress and fluid dynamics of ten idealised AAA models and one non-aneurysmal control. Five degrees of asymmetry with uniform and variable wall thickness are used. Each was modelled under a static pressure-deformation analysis, as well as a transient FSI. The results show that the inclusion of fluid flow yields a maximum AAA wall stress up to 20% higher compared to that obtained with a static wall stress analysis with an assumed peak luminal pressure of 117 mmHg. The variable wall models have a maximum wall stress nearly four times that of a uniform wall thickness, and also increasing with asymmetry in both instances. The inclusion of an axial stretch and external pressure to the computational domain decreases the wall stress by 17%.  相似文献   

11.
This study was conducted to determine whether local arterial pulsations are sufficient to cause cerebrospinal fluid (CSF) flow along perivascular spaces (PVS) within the spinal cord. A theoretical model of the perivascular space surrounding a "typical" small artery was analysed using computational fluid dynamics. Systolic pulsations were modelled as travelling waves on the arterial wall. The effects of wave geometry and variable pressure conditions on fluid flow were investigated. Arterial pulsations induce fluid movement in the PVS in the direction of arterial wave travel. Perivascular flow continues even in the presence of adverse pressure gradients of a few kilopascals. Flow rates are greater with increasing pulse wave velocities and arterial deformation, as both an absolute amplitude and as a proportion of the PVS. The model suggests that arterial pulsations are sufficient to cause fluid flow in the perivascular space even against modest adverse pressure gradients. Local increases in flow in this perivascular pumping mechanism or reduction in outflow may be important in the etiology of syringomyelia.  相似文献   

12.
Two different stent configurations (i.e. the well known Palmaz–Schatz (PS) and a new stent configuration) are mechanically investigated. A finite element model was used to study the two geometries under combining loads and a computational fluid dynamic model based on fluid structure interaction was developed investigating the plaque and the artery wall reactions in a stented arterial segment. These models determine the stress and displacement fields of the two stents under internal pressure conditions. Results suggested that stent designs cause alterations in vascular anatomy that adversely affect arterial stress distributions within the wall, which have impact in the vessel responses such as the restenosis. The hemodynamic analysis shows the use of new stent geometry suggests better biofluid mechanical response such as the deformation and the progressive amount of plaque growth.  相似文献   

13.
Micromotion-induced interstitial fluid flow at the bone-implant interface has been proposed to play an important role in aseptic loosening of cementless implants. High fluid velocities are thought to promote aseptic loosening through activation of osteoclasts, shear stress induced control of mesenchymal stem cells differentiation, or transport of molecules. In this study, our objectives were to characterize and quantify micromotion-induced fluid flow around a cementless femoral stem using finite element modeling. With a 2D model of the bone-implant interface and full-factorial design, we first evaluated the relative influence of material properties, and bone-implant micromotion and gap on fluid velocity. Transverse sections around a femoral stem were built from computed tomography images, while boundary conditions were obtained from experimental measurements on the same femur. In a second step, a 3D model was built from the same data-set to estimate the shear stress experienced by cells hosted in the peri-implant tissues. The full-factorial design analysis showed that local micromotion had the most influence on peak fluid velocity at the interface. Remarkable variations in fluid velocity were observed in the macrostructures at the surface of the implant in the 2D transverse sections of the stem. The 3D model predicted peak fluid velocities extending up to 2.2 mm/s in the granulation tissue and to 3.9 mm/s in the trabecular bone. Peak shear stresses on the cells hosted in these tissues ranged from 0.1 to 12.5 Pa. These results offer insight into mechanical stimuli encountered at the bone-implant interface.  相似文献   

14.
Mechanical properties of a single cell and its mechanical response under stimulation play an important role in regulating interactions between cell and extracellular matrix and affecting mechanotransduction. Osteocytes exhibit solid-like viscoelastic behavior in response to the interstitial fluid shear resulting from tissue matrix deformation. This study intends to quantitatively describe the mechanical behavior of osteocytes combining in vitro experiment and fluid–structure interaction (FSI) finite element (FE) model. The cell is configured in the FSI FE model using the observed data from quasi-3D images. Instead of simply assigning the cellular viscoelastic parameters by statistical data, the mechanical parameters are determined by an iterative algorithm comparing the experimental and the computational results from the FE model. The viscoelastic parameters of osteocytes are obtained as: the equilibrium elasticity modulus \(k_{1}=0.15\pm 0.038\,\hbox {kPa}\), instantaneous elasticity modulus \((k_{1}+k_{2})=0.77\pm 0.23\,\hbox {kPa}\), viscosity coefficient \(\eta =1.38\pm 0.33\,\hbox {kPa}\,\hbox {s}\). A novel index to quantify the cell adhesion is also put forward. In addition, an interesting competition phenomenon is revealed on the cell surface concerning stress and strain, i.e., the place with high stress has low strain and that with low stress has high strain. The proposed method provides a novel technique to study the mechanical behavior of individual adherent cell in vitro. It is believed that this quantitative technique not only determines cell mechanical behavior but also helps elucidate the mechanism of mechanotransduction in various types of cells.  相似文献   

15.
Symmetrical 30-60% stenosis in carotid artery with a semi-permeable wall under steady/unsteady flows for Newtonian/non-Newtonian fluids is investigated numerically. The results show that the unsteadiness of blood flow, blood pressure rise and LDL component size increase the luminal concentration, LC, of the surface. The maximum LC occurring immediately after the separation point and the non-Newtonian fluid predicts higher LDL accumulation. LC decreased as the recirculation length is increased and reaches maximum at 40% stenosis. This process is used to estimate the time-dependent growth of the arterial wall.  相似文献   

16.
The insertion of an endovascular prosthesis is known to have a thrombogenic effect that is also a consequence of the interaction between the flowing blood and the stented arterial segment; in fact the prosthesis induces a compliance mismatch and a possible small expansion along the vessel that eventually gives rise to an anomalous distribution of wall shear stresses. The fluid dynamics inside a rectilinear elastic vessel with compliance and section variation is studied here numerically. A recently introduced perturbative approach is employed to model the interaction between the fluid and the elastic tissue; this approximate technique is first validated by comparison with a complete solution within a simple one-dimensional model of the same system. Then it is applied to an axisymmetric model in order to evaluate the flow dynamics and the distribution of wall shear stress in the stented vessel. Compliance mismatch is shown to produce more intense negative wall shear stresses in the stented segment while rapid variations of wall shear stress are found at the stent ends. These effects are enhanced when the prosthesis is accompanied by a small increase of the vessel lumen.  相似文献   

17.
The development of atherosclerosis is correlated to the accumulation of lipids in the arterial wall, which, in turn, may be caused by the build-up of low-density lipoproteins (LDL) on the arterial surface. The goal of this study was to model blood flow within a subject specific human aorta, and to study how the LDL surface concentration changed during a cardiac cycle. With measured velocity profiles as boundary conditions, a scale-resolving technique (large eddy simulation, LES) was used to compute the pulsatile blood flow that was in the transitional regime. The relationship between wall shear stress (WSS) and LDL surface concentration was investigated, and it was found that the accumulation of LDL correlated well with WSS. In general, regions of low WSS corresponded to regions of increased LDL concentration and vice versa. The instantaneous LDL values changed significantly during a cardiac cycle; during systole the surface concentration was low due to increased convective fluid transport, while in diastole there was an increased accumulation of LDL on the surface. Therefore, the near-wall velocity was investigated at four representative locations, and it was concluded that in regions with disturbed flow the LDL concentration had significant temporal changes, indicating that LDL accumulation is sensitive to not only the WSS but also near-wall flow.  相似文献   

18.

This study was conducted to determine whether local arterial pulsations are sufficient to cause cerebrospinal fluid (CSF) flow along perivascular spaces (PVS) within the spinal cord. A theoretical model of the perivascular space surrounding a "typical" small artery was analysed using computational fluid dynamics. Systolic pulsations were modelled as travelling waves on the arterial wall. The effects of wave geometry and variable pressure conditions on fluid flow were investigated. Arterial pulsations induce fluid movement in the PVS in the direction of arterial wave travel. Perivascular flow continues even in the presence of adverse pressure gradients of a few kilopascals. Flow rates are greater with increasing pulse wave velocities and arterial deformation, as both an absolute amplitude and as a proportion of the PVS. The model suggests that arterial pulsations are sufficient to cause fluid flow in the perivascular space even against modest adverse pressure gradients. Local increases in flow in this perivascular pumping mechanism or reduction in outflow may be important in the etiology of syringomyelia.  相似文献   

19.
Naiki T  Karino T 《Biorheology》1999,36(3):243-256
The effect of steady shear flow on concentration polarization of plasma proteins and lipoproteins at the luminal surface of a semipermeable vessel wall was studied experimentally using suspensions of these molecules in a cell culture medium and a semipermeable membrane dialysis tube which served as a model of an implanted vascular graft or an artery. The study was carried out by flowing a cell culture medium containing fetal calf serum or bovine plasma lipoproteins or bovine albumin through a 7.5 mm diameter, 60 mm-long dialysis tube in steady flow under a physiologic mean arterial perfusion pressure of 100 mmHg, and measuring the filtration velocity of water (cell culture medium) at the vessel wall which varied as a consequence of the change in concentration of plasma protein particles at the luminal surface of the semipermeable membrane dialysis tube. It was found that for perfusates containing plasma proteins and/or lipoproteins, filtration velocity of water was the lowest in the absence of flow, and it increased or decreased as the flow rate (hence wall shear rate) increased or decreased from a certain non-zero value, indicating that surface concentration of protein particles varied reversibly as a direct function of flow rate. It was also found that at particle concentrations equivalent to those found in a culture medium containing serum at 5% by volume, plasma lipoproteins which were much smaller in number and lower in concentration but larger in size than albumin, had a much larger effect on the filtration velocity of water than albumin. These findings were very much the same as those previously obtained with a cultured endothelial cell monolayer, strongly suggesting that the flow-dependent variation in filtration velocity of water at a vessel wall results from a physical phenomenon, that is, flow-dependent concentration polarization of low density lipoproteins at the luminal surface of the endothelial cell monolayer.  相似文献   

20.
Wada S  Karino T 《Biorheology》1999,36(3):207-223
It is suspected that physical and fluid mechanical factors play important roles in the localization of atherosclerotic lesions and intimal hyperplasia in man by affecting the transport of cholesterol in flowing blood to arterial walls. Hence, we have studied theoretically the effects of various physical and fluid mechanical factors such as wall shear rate, diffusivity of low density lipoproteins (LDL), and filtration velocity of water at the vessel wall on surface concentration of LDL at an arterial wall by means of a computer simulation of convective and diffusive transport of LDL in flowing blood to the wall of a straight artery under conditions of a steady flow. It was found that under normal physiologic conditions prevailing in the human arterial system, due to the presence of a filtration flow of water at the vessel wall, flow-dependent concentration polarization (accumulation or depletion) of LDL occurs at a blood/endothelium boundary. The surface concentration of LDL at an arterial wall takes higher values than that in the bulk flow in that vessel, and it is affected by three major factors, that is, wall shear rate, gamma w, filtration velocity of water at the vessel wall, Vw, and the distance from the entrance of the artery, L. It increases with increasing Vw and L, and decreasing gamma w hence the flow rate. Thus, under certain circumstances, the surface concentration of LDL could rise locally to a value which is several times higher than that in the bulk flow, or drop locally to a value even lower than a critical concentration for the maintenance of normal functions and survival of cells forming the vessel wall. These results suggest the possibility that all the vascular phenomena such as the localization of atherosclerotic lesions and intimal hyperplasia, formation of cerebral aneurysms, and adaptive changes of lumen diameter and wall structure of arteries and veins to certain changes in hemodynamic conditions in the circulation are governed by this flow-dependent concentration polarization of LDL which carry cholesterol.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号