首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Chick embroys were exposed during their 52 first hours of development to 100-Hz magnetic fields. Sinusoidal, square and pulsed waveforms were used at average field strengths from 0.1 A/m to 80 A/m. After exposure, the embryos were examined for abnormalities and classified by the developmental stages. When bipolar oscillations (oscillating at both sides of the zero-level) were used, the percentage of abnormal embryos was significantly increased above 1 A/m. In exposure to unipolar square waves, no significant effect on the percentage of abnormalities could be demonstrated. The developmental stage was possibly affected by unipolar square waves at 0.1 A/m, all other field strengths and wave-forms being apparently ineffective.  相似文献   

2.
This study demonstrates that exposure to 60 Hz magnetic fields (3.4–8.8 mT) and magnetic fields over the range DC-600 kHz (2.5–6.5 mT) can alter the early embryonic development of sea urchin embryos by inducing alterations in the timing of the cell cycle. Batches of fertilized eggs were exposed to the fields produced by a coil system. Samples of the continuous cultures were taken and scored for cell division. The times of both the first and second cell divisions were advanced by ELF AC fields and by static fields. The magnitude of the 60 Hz effect appears proportional to the field strength over the range tested. The relationship to field frequency was nonlinear and complex. For certain frequencies above the ELF range, the exposure resulted in a delay of the onset of mitosis. The advance of mitosis was also dependent on the duration of exposure and on the timing of exposure relative to fertilization. © 1995 Wiley-Liss, Inc.  相似文献   

3.
Numerous experiments have yielded contradictory results on the harmful action of magnetic fields on embryonic development. Pulsed magnetic fields appear to be able to delay normal development of embryos. In the present study, fertilized Gallus domesticus eggs were exposed during incubation to pulsed magnetic fields (harmonic signals of 10 μT for 1 second with silences of 0.5 seconds) of 50 or 100 Hz frequency. Embryos extracted at 45 h of exposure to fields of 50 Hz or 100 Hz frequency had significantly (p<0.05) fewer somite pairs compared with controls of the same age. At 15 days of incubation, only embryos exposed to a 10 μT- 50 Hz field had a significantly (p<0.05) higher somatic weight. At 21 days of incubation, a significantly lower somatic weight (p<0.01) and development stage (p<0.05) was found in embryos exposed to a 10 μT-100 Hz field than in controls, while a lower development stage (p<0.05) alone was observed in those exposed to a 10 μT-50 Hz field. In addition, animals showed higher expression of the neural marker NSE (neural specific enolase) after 21 days of development as determined by immunohistochemistry, with very low expression of glycosaminoglycans identified by alcyan blue staining. These results suggest that pulsed magnetic fields may be able to hinder normal embryonic development in vivo and to alter normal neural function, at least at the intensities and frequencies analyzed in the present study.  相似文献   

4.
This investigation was undertaken because biological studies to evaluate the effects of intermediate frequency magnetic fields are insufficient. White Leghorn fertile eggs (60/group) were either exposed to a 20 kHz, 1.1 mT(rms) sinusoidal magnetic field or sham‐exposed during the first 2, 7, or 11 days of embryogenesis. Lower dose exposures at 0.011 and 0.11 mT(rms) for 2 days were also conducted to elucidate possible dose–response relationships. Additional eggs given all‐trans‐retinoic acid, a teratogen, were exposed to the 1.1 mT(rms) magnetic field for the same periods to investigate the modification of embryotoxicity. After exposure, embryos were examined for mortality and developmental abnormalities. Developmental stage, number of somite pairs, and other developmental endpoints were also evaluated. Experiments were triplicated and conducted in a blind fashion. No exposure‐related changes were found in any of the endpoints in intact embryos exposed to1.1 mT(rms) or to the lower doses of 0.11 and 0.011 mT(rms) magnetic fields. Retinoic acid administration produced embryotoxic responses, which were embryonic death and developmental abnormalities, in 40–60% of embryos in the sham‐exposed groups. The magnitude of these responses was not changed significantly by the magnetic field exposures. Under the present experimental conditions, exposure to 20 kHz magnetic field up to 1.1 mT(rms) was not embryotoxic in the chick and did not potentiate the embryotoxic action of retinoic acid. Bioelectromagnetics 30:573–582, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

5.
In order to study the possible association between epileptic seizures and natural electromagnetic fields, 32 female audiogenic seizure (AGS)-susceptible rats were exposed to simulated 10 kHz and 28 kHz atmospherics and to a sinusoidally oscillating magnetic field with a frequency of 100 Hz and field strength of 1 A/m. After the electromagnetic exposure, seizures were induced in the rats with a sound stimulus. The severity of the seizure was determined on an ordinal scale, the audiogenic response score (ARS). The time from the beginning of the sound stimulus to the onset of the seizure (seizure latency) and the duration of the convulsion was measured. No differences from the control experiments were found in the experiments with simulated atmospherics, but the 100 Hz magnetic field increased the seizure latency by about 13% (P<0.02). The results do not support the hypothesis that natural atmospheric electromagnetic signals could affect the onset of epileptic seizures, but they suggest that AGS-susceptible rats may be a useful model for studying the biological effects of electromagnetic fields.  相似文献   

6.
7.
Recent laboratory and epidemiological results have stimulated interest in the hypothesis that human beings may exhibit biological responses to magnetic and/or electric field transients with frequencies in the range between 100 Hz and 100 kHz. Much can be learned about the response of a system to a transient stimulation by understanding its response to sinusoidal disturbances over the entire frequency range of interest. Thus, the main effort of this paper was to compare the strengths of the electric fields induced in homogeneous ellipsoidal models by uniform 100 Hz through 100 kHz electric and magnetic fields. Over this frequency range, external electric fields of about 25–2000 V/m (depending primarily on the orientation of the body relative to the field) are required to induce electric fields inside models of adults and children that are similar in strength to those induced by an external 1 μT magnetic field. Additional analysis indicates that electric fields induced by uniform external electric and magnetic fields and by the nonuniform electric and magnetic fields produced by idealized point sources will not differ by more than a factor of two until the sources are brought close to the body. Published data on electric and magnetic field transients in residential environments indicate that, for most field orientations, the magnetic component will induce stronger electric fields inside adults and children than the electric component. This conclusion is also true for the currents induced in humans by typical levels of 60 Hz electric and magnetic fields in U.S. residences. Bioelectromagnetics 18:67–76, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

8.
The erythrocyte sedimentation rate (ESR) of human blood samples exposed to electric fields at frequencies ranging from 1 Hz to 100 kHz was measured. Statistically significant differences in ESR were found between the exposed and the control samples at most of the frequencies used. The results suggest a possible nonlinear dependence of the effect on frequency, the threshold field strength varying from about 25 V/m to about 5 kV/m.  相似文献   

9.
We have previously demonstrated that a weak, extremely-low-frequency magnetic field must be coherent for some minimum length of time (≈? 10 s) in order to affect the specific activity of ornithine decarboxylase (ODC) in L929 mouse cells. In this study we explore whether or not the superposition of an incoherent (noise) magnetic field can block the bioeffect of a coherent 60 Hz magnetic field, since the sum of the two fields is incoherent. An experimental test of this idea was conducted using as a biological marker the twofold enhancement of ODC activity found in L929 murine cells after exposure to a 60 Hz, 10 μTrms magnetic field. We superimposed an incoherent magnetic noise field, containing frequencies from 30 to 90 Hz, whose rms amplitude was comparable to that of the 60 Hz field. Under these conditions the ODC activity observed after exposure was equal to control levels. It is concluded that the superposition of incoherent magnetic fields can block the enhancement of ODC activity by a coherent magnetic field if the strength of the incoherent field is equal to or greater than that of the coherent field. When the superimposed, incoherent noise field was reduced in strength, the enhancement of ODC activity by the coherent field increased. Full ODC enhancement was obtained when the rms value of the applied EM noise was less than one-tenth that of the coherent field. These results are discussed in relation to the question of cellular detection of weak EM fields in the presence of endogenous thermal noise fields. © 1994 Wiley-Liss, Inc.  相似文献   

10.
Experimental data on calcium-ion release in chicken brain tissue suggest that biological effects of electric and magnetic fields (EMFs) are concentrated near certain “active combinations” of DC magnetic field strength and “effective” AC magnetic field frequencies. We hypothesize that active AC/DC combinations may exist and suggest that epidemiologic data, coupled with DC magnetic field measurements, may be used to identify critical exposure conditions. An empirical model is used to calculate these multiple active combinations at any given DC magnetic field strength and to define a rating system that incorporates the proximity of AC magnetic field frequencies generated by electric power lines to the new, computed effective frequencies. Such an exposure score may be useful in investigating correlations of EMF exposure with disease incidence. For 60 Hz and 50 Hz, the highest EMF exposure scores occurred at DC field strengths of 506 mG and 422 mG, respectively. The exposure score contains a factor which may be adjusted to reflect the importance of harmonics of the AC magnetic field as well as of the fundamental frequency. Using this factor, we consider two important special cases consistent with chick brain data: 1) we consider active pairs associated with all detectable harmonics (up to 660 Hz) without regard to relative intensity of the harmonics, and 2) we use the relative intensities of the AC field frequencies to adjust their contribution to the exposure score. © 1993 Wiley-Liss. Inc.  相似文献   

11.
Fertilized Medaka fish eggs were used to determine if electromagnetic fields, designed to simulate those beneath a high voltage power line, have biological effects on vertebrate embryo development. The newly fertilized eggs were exposed to a 60 Hz electrical field of 300 mA/m2 current density, a 60 Hz magnetic field of 1.0 gauss RMS, or to the combined electric plus magnetic fields for 48 hours. No gross abnormalities were observed in any of the embryos as they developed, but significant development delays were seen in those embryos exposed to either the magnetic or to the combined electromagnetic fields; delays were not seen in the embryos exposed to the electrical field. Thus, a 60 Hz magnetic field like that encountered in a man made powerline environment was shown to retard development of fish embryos.  相似文献   

12.
An exposure chamber was designed to study the effects of electric and magnetic fields (EMF) on oestrous cycles, hormonal profile during gestation, pineal function, quantity and quality of milk production, feed intake, and central nervous system of dairy cattle. The chamber was 15 x 10 x 3 m; and the control system was fully computerized so that the field intensities can be varied and monitored continuously, on site or remotely. During exposure to EMF, milk production, feed consumption, and health were monitored closely and blood and cerebral spinal fluid were continuously sampled. The chamber characteristics allow use of a wide range of exposure such as electric fields (0-30 kV/m) and magnetic fields (0-100 microT) at frequencies ranging from 45 to 3000 Hz.  相似文献   

13.
This study sought to estimate the relative contribution of exposure to 50 Hz magnetic fields experienced at home, at work/school, or elsewhere to the total exposure over 24 hr. Personal exposure meters were carried by 97 adults and children in the Stockholm area. About half of the subjects lived close (<50 m) to a transmission line and half far (>100 m) away. Spot measurements and calculations for the residential exposure were also made. For subjects living<50 m from the line, the exposure at home contributed about 80% of the total magnetic field exposure, measured in mT-hours. Adults living far away experienced only 38% of the total exposure at home, but children still received 55%. Subjects with low time-weighted average (TWA) exposure both at home and at work spent 84% of their time in fields <0.1 microT, and those with high TWA at both locations spent 69% of their time in fields > or = 0.2 microT. This contrast was diluted if only exposure at one location was considered. For spot measurements and calculations of the residential exposure, both sensitivity and specificity was good. However, the intermediate field exposure category (0.1-0.19 microT) showed poor correlation to the 24 hr personal measurements.  相似文献   

14.
Exposure to man-made electromagnetic fields has increased over the past century. As a result of exposure to these fields, concerns have been raised regarding the relationship between electromagnetic fields and human health. Interest in the biological and health effects of intermediate frequency (IF) magnetic fields has grown recently because of the increase in public concern. In order to investigate whether IF magnetic fields have biological effects, we have developed a 20 kHz (IF) magnetic field exposure system for in vivo studies. The exposure facility was designed to study the biological effects of IF magnetic field on laboratory animals. The facility consists of a 9 m x 9 m x 5 m high room containing seven separate rooms including a 5.3 m x 4.5 m x 3 m high specific-pathogen free exposure room. The dimensions of the exposure system are 1.6 m x 1.6 m x 1.616 m high located inside this exposure room. The system is designed to provide magnetic fields up to 200 microT at 20 kHz with the uniformity within +/-5% over the space occupied by animals. After constructing the facility, performance tests were carried out. As a result, it was confirmed that our facility met requirements for evaluation of the biological effects of IF magnetic field on small animal experiments. In this paper, the design, construction, and results of evaluation of an animal exposure facility for the in vivo biological effects of an IF magnetic field are described.  相似文献   

15.
A magnetic field exposure laboratory has been constructed to support National Toxicology Program studies for the evaluation of the toxicity and carcinogenicity of pure, linearly polarized, 60 Hz magnetic fields in rodents. This dual corridor, controlled access facility can support the simultaneous exposure of 1200 rats and 1200 mice. The facility contains fully redundant electrical and environmental control systems and was constructed using non‐metallic materials to maintain low levels of background (ambient), stray, and cross‐talk magnetic fields. The exposure module design provides for large uniform exposure volumes with good control of stray and cross‐talk fields, while allowing the use of roll‐around cage racks for simplified animal husbandry. Stray fields and cross‐talk have been further reduced by the inclusion of “steering coils” in each exposure module. Ambient 60 Hz fields (less cross‐talk) in all exposure rooms are <0.1 μT (1 mG), and static magnetic fields have been mapped extensively. Magnetic field strength, waveform, temperature, relative humidity, light intensity, noise level, vibration, and air flow in all animal holding areas are tightly regulated, and are monitored continuously during all studies. Field uniformity in the animal exposure volumes is better than ±10%; a systematic program of cage, rack, and room rotation controls for possible positional effects within the exposure system. Magnetic fields are turned on and off over multiple cycles to prevent the induction of transients associated with abrupt field level changes. Total harmonic distortion is <3% at all field strengths. The facility has been used to study magnetic field bioeffects in rodent model systems in experiments ranging in duration from 8 weeks to 2 years. Bioelectromagnetics 20:13–23, 1999. © 1999 Wiley‐Liss, Inc.  相似文献   

16.
Tests were made to determine whether the development of chicken embryos was altered by exposure to time-varying magnetic fields. Unipolar square waves with periods of 100μs, 1, 10, 20, and 30ms, and 20ms bipolar square and sinusoidal waves were tested. The nominal peak strength for each experiment was 1μT. Neither the morphogenesis of the embryo nor the temporal aspects of development was altered by any tested field. Fertile eggs of several different strains of chickens were also tested to determine whether strain sensitivity to certain magnetic fields can account for the reports of positive effects of magnetic fields upon development. No significant alterations were noted in the embryos of any of the tested strains. Published reports of alterations in development following exposure to similar low level magnetic fields have not been confirmed in this laboratory.  相似文献   

17.
We have developed an intermediate frequency (IF) magnetic field exposure system for in vitro studies. Since there are no previous studies on exposure to heating-frequency magnetic fields generated from an induction heating (IH) cook top, there is a strong need for such an exposure system and for biological studies of IF magnetic fields. This system mainly consists of a magnetic-field-generating coil housed inside an incubator, inside which cultured cells can be exposed to magnetic field. Two systems were prepared to allow the experiment to be conducted in a double-blind manner. The level of the generated magnetic field was set to 532 microT rms in the exposure space, 23 kHz, 80 times the value in the International Commission on Non-ionizing Radiation Protection (ICNIRP) guidelines, with a spatial field uniformity better than 3.8%. The waveforms were nearly sinusoidal. It was also confirmed that the parasitic electric field was 157 V/m rms and the induced electric field was 1.9 V/m rms. The temperature was maintained at 36.5 +/- 0.5 degrees C for 2 h. Furthermore, leaked magnetic flux density was 0.7 microT rms or lower at extremely low frequency (ELF) and IF in the stopped system when the other system was being operated, and the environmental magnetic flux density was 0.1 microT rms or lower at the center of the coils. As a result, it was confirmed that this system could be successfully used to evaluate the biological effects of exposure to IF magnetic fields.  相似文献   

18.
Four-day-old chicken embryos were exposed to extremely low frequency (ELF) magnetic fields (MF) prior to UV exposure (75 min, predominantly UV-C, 0.4 mW/cm2) to investigate possible MF-mediated protection against lethal effects of UV. The UV exposure typically resulted in a 20% survival rate (as judged by beating hearts) in sham-exposed embryos 3 h postexposure. In contrast, exposure to a 50 (10, 50, or 100 µT) or 60 Hz (10 µT) vertical MF caused a significant increase in survival rate, observed only 30 min after UV exposure. No difference in protection levels was seen between these exposure intensities. A horizontal 50 Hz MF (10, 50, or 100 µT) did not result in the general protection against UV-induced death observed for vertical fields, suggesting that the size of the induced electric field (which differs between horizontal and vertical exposure) is important for the MF-induced protection. To explore the molecular mechanisms involved in this effect, immunoblotting experiments with an antibody against the inducible form of hsp70 were performed. These showed that application of MF (50 Hz, 200 µT, 1 h) induced hsp70 expression in human K562 cells.  相似文献   

19.
To maximize the availability and usefulness of a small magnetic field exposure laboratory, we designed a magnetic field exposure system that has been used to test human subjects, caged or confined animals, and cell cultures. The magnetic field exposure system consists of three orthogonal pairs of coils 2 m square x 1 m separation, 1.751 m x 0.875 m separation, and 1.5 m x 0.75 m separation. Each coil consisted of ten turns of insulated 8 gauge stranded copper conductor. Each of the pairs were driven by a constant-current amplifier via digital to analog (D/A) converter. A 9 pole zero-gain active Bessel low-pass filter (1 kHz corner frequency) before the amplifier input attenuated the expected high frequencies generated by the D/A conversion. The magnetic field was monitored with a 3D fluxgate magnetometer (0-3 kHz, +/- 1 mT) through an analog to digital converter. Behavioral monitoring utilized two monochrome video cameras (viewing the coil center vertically and horizontally), both of which could be video recorded and real-time digitally Moving Picture Experts Group (MPEG) encoded to CD-ROM. Human postural sway (standing balance) was monitored with a 3D forceplate mounted on the floor, connected to an analog to digital converter. Lighting was provided by 12 offset overhead dimmable fluorescent track lights and monitored using a digitally connected spectroradiometer. The dc resistance, inductance of each coil pair connected in series were 1.5 m coil (0.27 Omega, 1.2 mH), 1.75 m coil (0.32 Omega, 1.4 mH), and 2 m coil (0.38 Omega, 1.6 mH). The frequency response of the 1.5 m coil set was 500 Hz at +/- 463 microT, 1 kHz at +/- 232 microT, 150 micros rise time from -200 microT(pk) to + 200 microT(pk) (square wave) and is limited by the maximum voltage ( +/- 146 V) of the amplifier (Bessel filter bypassed).  相似文献   

20.
Recent epidemiological studies suggest a link between transport magnetic fields (MF) and certain adverse health effects. We performed measurements in workplaces of engineers on Russian DC and Swiss AC powered (16.67 Hz) electric trains using a computer based waveform capture system with a 200 Hz sampling rate. MF in DC and AC trains show complex combinations of static and varying components. The most probable levels of quasistatic MF (0.001-0.03 Hz) were in the range 40 microT. Maximum levels of 120 microT were found in DC powered locomotives. These levels are much higher than the geomagnetic field at the site of measurements. MF encountered both in DC and AC powered rail systems showed irregular temporal variability in frequency composition and amplitude characteristics across the whole frequency range studied (0-50 Hz); however, more than 90% of the magnetic field power was concentrated in frequencies 相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号