首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
High performance liquid chromatographic (HPLC) methods were validated for the determination of aripiprazole (OPC-14597, Abilify) in rat plasma and brain. Separation was by Nova-pak phenyl column; flow rate, 1.0 ml/min; mobile phase, acetonitrile-methanol-20 mM sodium sulfate-acetic acid (27:25:48:1, v/v/v/v); UV detection at 254 nm. Reproducibility in plasma and brain showed excellent precision (within 7.8 and 10.6%) and accuracy (96.0-102.4% and 99.0-108.7%) with calibration curve ranges 10.0-2000 ng/ml and 30.0-6000 ng/g, respectively. Validated HPLC methods were successfully applied to pharmacokinetic study of aripiprazole in rats, demonstrating brain concentrations after oral administration five times higher than plasma concentrations.  相似文献   

2.
Aripiprazole is a novel antipsychotic drug for the treatment of schizophrenia and schizoaffective disorders. In this study, a new method using gas chromatography-mass spectrometry (GC-MS) was developed and validated for the detection of aripiprazole and its main metabolite, dehydroaripiprazole, in plasma. Blood samples from seven psychiatric patients treated with aripiprazole (10-20 mg/day) underwent a solid-phase extraction (SPE) and N-methyl-N-trimethylsilytrifluoroacetamide (MSTFA) derivatization. The characteristic ions of mass spectra for aripiprazole and dehydroaripiprazole were m/z 306, 292, 218 and 304, 290, 218, respectively. Extraction recoveries from this method were 75.4% (n=5) for aripiprazole and 102.3% (n=5) for dehydroaripiprazole. The calibration curves of aripiprazole and dehydroaripiprazole were linear from 16 to 500 ng/ml (r(2)=0.999) and 8 to 250 ng/ml (r(2)=0.999), respectively. The respective limits of quantification (LOQs) for aripiprazole and dehydroaripiprazole evaluated in 0.5 ml of serum were 14.4 ng/ml and 6.9 ng/ml. Intra-assay and interassay precision and accuracy were within acceptable ranges. In this study, we also found that the mean trough concentrations in plasma at steady-state were 128.9 microg/l for aripiprazole and 30.1 microg/l for dehydroaripiprazole.  相似文献   

3.
A selective, sensitive, and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of aripiprazole and its active metabolite dehydroaripiprazole in human plasma has been developed using papaverine as internal standard (IS). LC-MS/MS analysis was carried out on a Finnigan LC-TSQ Quantum mass spectrometer using positive ion electrospray ionization (ESI+) and selected reaction monitoring (SRM). The assays for aripiprazole and dehydroaripiprazole were linear over the ranges of 0.1 to 600 ng/ml and 0.01 to 60 ng/ml, respectively. The average recoveries in plasma samples both were better than 85%. The intra- and interrun precision and accuracy values were found to be within the assay variability criteria limits according to the US Food and Drug Administration guidelines. The developed method was proved to be suitable for use in a clinical pharmacokinetic study after a single oral administration of a 5-mg aripiprazole tablet in healthy Chinese volunteers.  相似文献   

4.
A high-performance liquid chromatography method with diode array detection (HPLC-DAD) was developed for quantification of aripiprazole and dehydro-aripiprazole, in human plasma. After a simple liquid-liquid extraction, chromatographic separation was carried out on a C18 reversed-phase column, using an ammonium buffer-acetonitrile mobile phase (40:60, v/v). The total run time was only 7 min at a flow-rate of 1.0 ml/min. The precision values were less than 12% and the accuracy values were ranging from 98 to 113% and the lower limit of quantification was 2 ng/ml for both compounds. Calibration curves were linear over a range of 2-1000 ng/ml. The mean trough plasma concentrations in patients treated with aripiprazole were 157 and 29 ng/ml for aripiprazole and dehydro-aripiprazole, respectively.  相似文献   

5.
A high-performance liquid chromatographic (HPLC) method for the simultaneous determination of cilostazol, a quinolinone derivative, and its known metabolites OPC-13015, OPC-13213, OPC-13217, OPC-13366, OPC-13269, OPC-13326 and OPC-13388 in human plasma was developed and validated. Cilostazol, its metabolites and two internal standards, OPC-3930 and OPC-13112, were extracted from human plasma by a combination of liquid–liquid and liquid–solid phase extractions, with combined organic solvents of n-butanol, methanol, chloroform, methyl-tert.-butyl ether, and a Sep-Pak silica column. The combined extract was then evaporated and the residue was reconstituted in ammonium acetate buffer (pH 6.5). The reconstituted solution was injected onto a HPLC system and was subjected to reversed-phase HPLC on a 5 μm ODS-80TM column to obtain quality chromatograph and good peak resolution. A gradient mobile phase with different percentages of acetonitrile in acetate buffer (pH 6.5) was used for the resolution of analytes. Cilostazol, its metabolites and the two internal standards were well separated at baseline from each other with resolution factor being 74 and 138. This HPLC method was demonstrated to be specific for all analytes of interest with no significant interference from the endogenous substances of human plasma. The lower limit of quantitation was 20 ng/ml for cilostazol and all metabolites. The method was validated initially for an extended linear range of 20–600 ng/ml for all metabolites and cilostazol, and has been revised later for a linear range of 20–1200 ng/ml for cilostazol and two major and active metabolites OPC-13015 and OPC-13213. The overall accuracy (relative recovery) of this method was established to be 98.5% to 104.9% for analytes with overall precision (CV) being 1.5% to 9.0%. The long-term stability of clinical plasma samples was established for at least one year at −20°C. Two internal standards of OPC-3930 and OPC-13112 were evaluated and validated. However, the data indicated that there was no significant difference for all accuracy and precision obtained by using either OPC-3930 or OPC-13112. OPC-3930 was chosen as the internal standard for the analysis of plasma samples from clinical studies due to its shorter retention time. During the validation standard curves had correlation coefficients greater than or equal to 0.998 for cilostazol and the seven metabolites. These data clearly demonstrate the reliability and reproducibility of the method.  相似文献   

6.
Sensitive methods based on capillary gas chromatography (GC) with mass spectrometric (MS) detection in a selected-ion monitoring mode (SIM) for the determination of a cyclooxygenase II (COX-II) inhibitor (3-isopropoxy-4-(4-methanesulfonylphenyl)-5,5'-dimethyl-5H-furan-2-one, I) in human plasma, in two concentration ranges of 0.1-20 and 5-1000 ng/ml, are described. Following liquid-liquid extraction, the residue, after evaporation of the organic phase to dryness, was reconstituted in acetonitrile (20 l) and part of the extract (1 l) was analyzed by GC/MS/SIM. The drug (I) and internal standard (II) were separated on a 25 mx0.2 mm capillary column with HP Ultra 1 (100% dimethylpolysiloxane, 0.33 m) phase and analyzed by MS/SIM monitoring ions at m/z 237 and 282 for I and II, respectively. The standard curve was linear within the lower concentration range of 0.1-20 ng/ml and the lower limit of quantification (LLOQ) in plasma was 0.1 ng/ml. Intraday coefficients of variation (CV, n=5) were 8.9, 4.2, 5.7, 3.1, 1.9, 1.9, and 4.4% at 0.1, 0.2, 0.5, 1.0, 5.0, 10, and 20 ng/ml, respectively. The standard curve was also linear within the higher concentration range of 5-1000 ng/ml and the LLOQ in plasma was 5 ng/ml. Intraday coefficients of variation (CV, n=5) were all below 9% at all concentrations within the standard curve range. The accuracy for I in human plasma was 91-112% and the recovery of I and II was greater than 70% at all concentrations within both standard curve ranges. The details of the assay methodology are presented.  相似文献   

7.
The analysis of arildone in plasma, urine and feces by gas—liquid chromatography with electron-capture detection is described. O-(2,3,4,5,6-Pentafluorohenzyl)hydroxylamine is the derivatizing agent for the plasma and urine analysis; 3-nitrophenylhydrazine is utilized for fecal analysis. The mean (± S.E.) minimum quantifiable level of arildone was 1.4 (± 0.2) ng/ml in urine, 6.4 (± 0.1) ng/ml in plasma, and 12.6 (± 1.0) ng/g in feces. The chromatographic response was linear in the range of 0 and 10–120 ng/ml for plasma, 0 and 2.5–20 ng/ml for urine and 0 and 25–250 ng/g for feces. The estimated overall precision of the assay was 5.5%, 6.4% and 8.9% in urine, plasma and feces, respectively.  相似文献   

8.
BAPTA free acid was identified as the main metabolic product of 1,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid tetra(actoxymethyl ester) (BAPTA-AM), a neuroprotective agent in cerebral ischemia, in rats. In this paper, liquid chromatography-ultraviolet (LC-UV) and mass spectrometry/mass spectrometry (LC-MS/MS) methods were employed for the determination of BAPTA free acid in rat urine and feces and rat plasma, respectively. By liquid-liquid extraction and LC-UV analysis, a limit of quantitation of 1000 ng/ml using 0.2 ml rat urine for extraction and 250 ng/ml using 1 ml rat fecal homogenate supernatant for extraction could be reached. The assay was linear in the range of 1000-50,000 ng/ml for rat urine and 250-10,000 ng/ml for rat fecal homogenate supernatant. Because the sensitivity of the LC-UV method was apparently insufficient for evaluating the pharmacokinetic profile of BAPTA in rat plasma, a LC-MS/MS method was subsequently developed for the analysis of BAPTA free acid. By protein precipitation and LC-MS/MS analysis, the limit of quantitation was 5 ng/ml using 0.1 ml rat plasma and the linear range was 5.0-500 ng/ml. Both methods were validated and can be used to support a thorough preclinical pharmacokinetic evaluation of BAPTA-AM liposome injection.  相似文献   

9.
We have developed and validated a sensitive and selective assay for the quantification of paclitaxel and its metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in plasma, tissue, urine and faeces specimens of mice. Tissue and faeces were homogenized (approximately 0.1–0.2 g/ml) in bovine serum albumin (40 g/I) in water, and urine was diluted (1:5, v/v) in blank human plasma. Sample pretreatment involved liquid-liquid extraction of 200–1000 μl of sample with diethyl ether followed by automated solid-phase extraction using cyano Bond Elut column. 2′-Methylpaclitaxel was used as internal standard. The overall recovery of the sample pretreatment procedure ranged from 76 ot 85%. In plasma, the lower limit of detection (LOD) and the lower limit of quantitation (LLQ) are 15 and 25 ng/ml, respectively, using 200 μl of sample. In tissues, faeces and urine the LLQs are 25–100 ng/g, 125 ng/g and 25 ng/ml, respectively, using 1000 μl (faeces: 200 μl) of homogenized or diluted sample. The concentrations in the various biological matrices, for validation procedures spiked with known amounts of the test compounds, are read from calibration curves constructed in blank human plasma in the range 25–100 000 ng/ml for paclitaxel and 25–500 ng/ml for the metabolites. The accuracy and precision of the assay fall within the generally accepted criteria for bio-analytical assays.  相似文献   

10.
This work presents a high-throughput selected reaction monitoring (SRM) LC-MS method for the determination of methylphenidate (MPH), a central nervous stimulant, and its de-esterified metabolite, ritalinic acid (RA) in rat plasma samples. A separation of these two compounds was achieved in 15 s by employing a 3.5-ml/min flow-rate, a porous monolithic column and a TurboIonSpray source compatible with relatively high flow-rates. In addition, a relatively fast autosampler and a new data acquisition system resulted in a time lag of less than 17 s between consecutive injections. Overall, 768 protein-precipitated rat plasma samples (eight 96-well plates) containing both MPH and RA were analyzed within 3 h and 45 min. The partial method validation described in this report included an assessment of linearity, intra and inter-assay precision and accuracy, and method robustness. Deuterated internal standards for the target compounds, d(3)-MPH and d(5)-RA, were employed. The calibration curves ranged from 0.1 to 50 ng/ml for MPH and from 0.5 to 50 ng/ml for RA. The limit of quantification (LOQ) for MPH and RA was 0.1 and 0.5 ng/ml, respectively. For both analytes, the intra- and inter-assay precision (relative standard deviation, % C.V.) and accuracy (relative error) did not exceed 15% for the quality control samples (QCs) QC1, QC2 or QC3 (0.3, 1.5 and 40 ng/ml for MPH and 0.15, 15 and 40 ng/ml for RA) for either analyte and did not exceed 20% at the lower limit of quantitation (LOQ) level. No carry-over from the autosampler was detected. The retention times remained constant throughout the experiment. Baseline resolution of MPH and RA was consistently observed throughout the plates analyzed. The described method demonstrates the feasibility for employing monolithic HPLC columns to effect rapid bioanalytical SRM LC-MS analysis of representative biological samples.  相似文献   

11.
A selective and sensitive high-performance liquid chromatographic assay for a novel cognitive enhancer, X9121 (I), and its mono N-oxide metabolite, XG696 (II), in dog plasma has been developed. Compounds I, II and internal standard (I.S.) were first extracted from dog plasma using a solid-phase Bond Elut Certify I 10-ml LRC reservoir extraction cartridge. Chromatographic separation of I, II and I.S. was conducted on a reversed-phase Zorbax Stable Bond cyano column. Ammonium acetate buffer (0.05 M, pH 6)-acetonitrile-triethylamine (75:25:0.1, v/v) was used as the mobile phase. Detection of all three compounds was by UV light absorbance at 313 nm. Using 0.5 ml of dog plasma for extraction, the minimum quantifiable limit was 10 ng/ml and the assay was linear from 10 to 5400 ng/ml. The coefficients of variation for intra-day precision ranged from 2.2 to 8.5% for I and from 2.5 to 9.8% for II. The coefficients of variation for the inter-day precision for these two compounds ranged from 2.6 to 9.0% and from 3.6 to 16.2%, respectively. The absolute percent differences for the accuracy results were within 11.0% of the spiked concentrations. Compounds I and II were stable in frozen plasma at −20°C for at least 67 days.  相似文献   

12.
The objectives of this study were to investigate the plasma E(1)S and E(2)beta profiles during pregnancy and their relationship with the relaxation of sacrosciatic ligament in Holstein-Friesian cattle (n=37) and then to predict the calving time on the basis of E(1)S and E(2)beta profiles and relaxation of the ligament. Blood samples were collected at 4 weeks intervals from days 100 to 190, at 2 weeks intervals from days 190 to 250, every week from days 250 to 270 and thereafter every day from day 270 of gestation until the day after calving. The relaxation in the ligament was measured by using two scales as a distance at a schedule similar to blood sampling plus 5 days postpartum. One scale was kept firm exactly parallel to the ligament between the sacrum and the tuber ischii and other scale was erected perpendicularly to the first scale with the bottom just touching the ligament and the depth was measured in the second scale from the point where it touched the ligament to the point where it touched the first scale. Plasma samples were analyzed for E(1)S and E(2)beta by enzyme immunoassay. E(1)S concentration was low at day 100 (0.8+/-0.3 ng/ml), then increased progressively and drastically to reach the level of 28.4+/-3.6 ng/ml on the day before calving and declined significantly (p<0.05) at 9.5+/-3.1 ng/ml within 1 day postpartum. There was a gradual increase in concentration of E(2)beta from day 100 of gestation (0.1+/-0 ng/ml) until day 4 prepartum (0.6+/-0 ng/ml). Thereafter, it increased drastically and reached the peak level of 1.0+/-0.1 ng/ml (p<0.05) on the day before calving and declined markedly at 0.4+/-0.1 ng/ml within 1 day postpartum (p<0.05). Corresponding to E(1)S and E(2)beta concentrations, a gradual increase in the relaxation of the ligament was observed from day 100 of gestation (8+/-1mm) until day 2 prepartum (24+/-2mm). Thereafter, it showed a significant increase (p<0.05) within 1 day before calving (31+/-2mm) and almost no difference between day 1 prepartum and day 1 postpartum. A marked decrease (p<0.05) was observed thereafter until day 3 postpartum (10+/-2mm) and no significant change between days 3 and 4 as well as 4 and 5 postpartum. The increment of E(2)beta by >or=0.20 ng/ml from the preceding day concentration was 85.2% accurate for predicting calving within 24h in many of the cows (23 of 37) in the herd. The increment in ligament relaxation measurement by >or=5mm from the preceding day measurement was the most efficacious to predict calving within 24h with the highest accuracy (93.9%) in high proportions of cows (31 of 37) in the herd. In conclusion, plasma E(1)S and E(2)beta concentrations and relaxation of sacrosciatic ligament increased gradually as gestation advanced and reached the peak level on the day before calving. The relaxation in the ligament corresponded well to plasma E(2)beta concentrations. Prediction of calving was possible by E(2)beta profile and relaxation in the ligament but not by E(1)S profile. The increment in ligament measurement by >or=5mm from the preceding day measurement was the most useful and accurate in predicting calving within 24h. It is economical and easily applicable in the field condition.  相似文献   

13.
A simple extraction procedure and a sensitive high-performance liquid chromatographic (HPLC) method are described for the determination of the photodynamic therapeutic agent 5, 10, 15, 20-tetra(m-hydroxyphenyl)chlorin (mTHPC) in plasma and tumour tissue. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70×4.6 mm I.D.) with a mobile phase of 0.01 M potassium dihydrogenphosphate buffer, pH 2.5-acetonitrile (55:45, v/v) and a coulometric detection (+0.80 V). The mean recoveries of mTHPC in the concentration ranges (5–2000 and 10–1000 ng/ml) were 90 and 89% for plasma and tumour samples, respectively. The procedure for plasma and tissue preparation involved solvent precipitation using methanol combined with ammonia solution and dimethyl sulphoxide (4, 0.2, 0.1, v/v/v) and (2, 0.1, 0.1, v/v/v) for plasma and tissue, respectively. For mTHPC at concentrations ranging from 5 to 2000 ng/ml, the within-day relative standard deviations, based on triplicate determinations were less than 8% and the between-day relative standard deviations calculated by performing extraction procedure of plasma samples on three different days ranged from 3 to 18%. This highly sensitive method, 5 and 10 ng/ml for plasma and tissue respectively, was applied successfully to the determination of mTHPC in mouse tumours for pharmacokinetic studies.  相似文献   

14.
The aim of this study was to determine, for goats, the effects of daily doses of GnRH antagonist on ovarian endocrine and follicular function. Ten does were given 45 mg FGA intravaginal sponges and then five were treated with daily injections of 0.5mg of the GnRH antagonist Teverelix for 11 days from 2 days after the day of sponge insertion, while five does acted as controls. Pituitary activity was monitored by measuring plasma FSH and LH daily from 2 days before the first GnRH injection to Day 12. Follicular activity was determined by ultrasonographic monitoring and by assessing plasma inhibin A levels during the same period. In treated does, the FSH levels decreased linearly (0.8 +/- 0.1 ng/ml to 0.5 +/- 0.1 ng/ml, P < 0.01) and remained lower than the mean concentration in control goats (0.8 +/- 0.1 ng/ml, P < 0.005). LH levels were also lower during the period of antagonist treatment (0.6 +/- 0.2 ng/ml versus 0.4 +/- 0.1 ng/ml, P < 0.0005). During GnRH antagonist treatment, there was a significant decrease in the number of large follicles (> or = 6 mm) from Day 3 of treatment (1.2 +/- 0.6, P < 0.0001), with no large follicles from Day 9. The number of medium follicles (4-5 mm in size) also decrease during the period of treatment (4.2 +/- 0.7 to 1.0 +/- 0.6, P < 0.0001), leading to a significant decrease in inhibin A levels when compared to the control (143.7 +/- 31.3 pg/ml versus 65.2 +/- 19.1 pg/ml, P < 0.00005). In contrast, the number of small follicles (2-3 mm) increased in treated goats from Day 4 of treatment (9.6 +/- 2.9 to 20.2 +/- 6.3, P < 0.005). Such data indicate that GnRH antagonist reduced plasma levels of FSH and LH with suppression of the growth of large dominant ovarian follicles and a two-fold increase in number of smaller follicles. The results confirm that GnRH antagonist treatment can be used in goats to control gonadotrophin secretion and ovarian follicle growth in superovulatory regimes.  相似文献   

15.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the determination of baicalein, baicalin, oroxylin A and wogonin, Scutellaria baicalensis active components in rat plasma was developed. After liquid-liquid extraction with 2-(3,4-dimethoxy-phenyl)-5,7-dihydroxy-chromen-4-one as internal standard, baicalein, baicalin, oroxylin A and wogonin were eluted from an Atlantis C(18) column within 7 min with isocratic mobile phase consisting of methanol and 0.1% formic acid (60:40, v/v). The analytes were detected using an electrospray ionization tandem mass spectrometry in the multiple reaction monitoring (MRM) mode. The standard curves were linear (r=1.000) over the concentration ranges of 5-500 ng/ml for baicalein, wogonin and oroxylin A and 5-5000 ng/ml for baicalin. The coefficients of variation and relative errors of baicalein, wogonin, oroxylin A and baicalin for intra- and inter-assay at three or four quality control (QC) levels were 0.8-6.1% and -4.0 to 5.8%, respectively. The lower limits of quantification for baicalein, wogonin, oroxylin A and baicalin were 5ng/ml using 50 microl of plasma sample. This method was successfully applied to the pharmacokinetic study of baicalein, baicalin, wogonin and oroxylin A after an intravenous administration of Scutellariae radix extract to male Sprague-Dawley rats.  相似文献   

16.
The seasonal changes in testicular weight in the blue fox were associated with considerable variations in plasma concentrations of LH, prolactin, androstenedione and testosterone and in FSH-binding capacity of the testis. An increase in LH secretion and a 5-fold increase in FSH-binding capacity were observed during December and January, as testis weight increased rapidly. LH levels fell during March when testicular weight was maximal. Plasma androgen concentrations reached their peak values in the second half of March (androstenedione: 0.9 +/- 0.1 ng/ml: testosterone: 3.6 +/- 0.6 ng/ml). A small temporary increase in LH was seen in May and June after the breeding season as testicular weight declined rapidly before levels returned to the basal state (0.5-7 ng/ml) that lasted until December. There were clear seasonal variations in the androgenic response of the testis to LH challenge. Plasma prolactin concentrations (2-3 ng/ml) were basal from August until the end of March when levels rose steadily to reach peak values (up to 13 ng/ml) in May and June just before maximum daylength and temperature. The circannual variations in plasma prolactin after castration were indistinguishable from those in intact animals, but LH concentrations were higher than normal for at least 1 year after castration.  相似文献   

17.
Peripheral plasma concentrations of LH, oestradiol-17 beta and progesterone were measured in 13 mature swamp buffalo cows at 4-h intervals from 36-40 h before until 36-40 h after the onset of oestrus. Mean LH concentrations increased sharply to a peak of 35 ng/ml and returned to basal levels of 5 ng/ml within a 12-h period beginning soon after the onset of oestrus. Mean oestradiol-17 beta concentrations were within the range 9-13 pg/ml from 36-40 h before until 12-16 h after the onset of oestrus, and within the range 7-9 pg/ml thereafter. Progesterone concentrations remained around 0.1 ng/ml throughout the sampling period. There were no significant differences in hormone concentrations or changes between cows that conceived and those that did not conceive to artificial insemination 12-24 h after onset of oestrus.  相似文献   

18.
Persistence of luteal function and accumulation of fluid within the uterus (hydrometra) are characteristics of pseudopregnancy in goats. To study the luteotrophic role of prolactin in this condition, seven seudopregnant goats were treated with bromocryptine (1 mg subcutaneously, twice daily) for 6 to 10 d. Plasma progesterone (P4) and prolactin (PRL) were measured by radioimmunoassay (RIA) in samples taken twice daily by venipuncture. Ultrasound scanning took place at regular intervals to visualize the presence of fluid within the uterus. Bromocryptine treatment effectively reduced the plasma PRL concentration in six goats. In all seven goats, a gradual decrease of the plasma P4 concentration to levels < 1.8 ng/ml occured during treatment. After bromocryptine treatment, P4 concentrations reached basal levels (<0.1 ng/ml) in two animals. In four goats, P4 concentrations remained close to 1.0 ng/ml, or even temporarily rose above the 2.0 ng/ml level. Spontaneous discharge of uterine fluid took place during (two goats) or within 4 d after bromocryptine treatment (three goats). These results indicate that prolactin plays an important luteotrophic role during pseudopregnancy in goats.  相似文献   

19.
This paper describes a method of determining clioquinol levels in hamster plasma and tissue by means of HPLC and electrochemical detection. Clioquinol was separated on a Nucleosil C18 300 mm x 3.9 mm i.d. 7 microm column at 1 ml/min using a phosphate/citrate buffer 0.1M (400 ml) with 600 ml of a methanol:acetonitrile (1:1, v/v) mobile phase. The retention times of clioquinol and the IS were, respectively, 11.6 and 8.1 min; the quantitation limit (CV>8%) was 5 ng/ml in plasma and 10 ng/ml in tissues. The intra- and inter-assay accuracies of the method were more than 95%, with coefficients of variation between 3.0 and 7.7%, and plasma and tissue recovery rates of 72-77%. There was a linear response to clioquinol 5-2000 ng/ml in plasma, and 10-1000 ng/g in tissues. The method is highly sensitive and selective, makes it possible to study the pharmacokinetics of plasma clioquinol after oral administration and the distribution of clioquinol in tissues, and could be used to monitor plasma clioquinol levels in humans.  相似文献   

20.
This paper describes a sensitive HPLC-electrochemical detection analytical method for determining the concentration of the intravenous anesthetic, propofol, in human or rat plasma or serum and a variety of rat tissues. Internal standard and drug are extracted from serum or plasma and other tissues with pentane. 2,6-tert.-Butylmethylphenol is used as internal standard. It includes a novel steam distillation procedure for separating the highly lipophilic propofol from skin and fat. The plasma/serum assay has a precision of 1–4% (C.V.) in the range 10 ng/ml to 1 μg/ml and permits the assay of 5 ng/ml from 0.1 ml of plasma/serum. The tissue procedure allows the estimation of 50 ng/g in 0.1 g of tissue for most of the major organs with less than 2% (C.V.) precision. This assay was used to measure propofol concentrations in plasma/serum and tissue samples in support of a project to develop a physiological pharmacokinetic model for propofol in the rat.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号