首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Surface wettability and microtopography can either enhance or deter larval settlement of many sessile marine organisms. This study quantifies the effect of these surface properties on the settlement of pediveligers of Mytilus galloprovincialis, using polymers spanning a range of wettability and microtextured polydimethylsiloxane (PDMS). Furthermore, the adhesion strength of settled pediveligers on microtextured PDMS surfaces was quantified using a flow chamber. Settlement was enhanced at the hydrophilic end of the wettability spectrum, where mean settlement on nylon reached 33.5 ± 13.1%. In contrast, mean settlement on the most hydrophobic polymer (PDMS) was 4.2 ± 3.2%. Microtopography had a much stronger effect compared to wettability, where 400 μm textured PDMS enhanced settlement above 90%. Settlement preferences were also positively correlated to adhesion strength at flow rates of 4 knots, with all initially settled pediveligers on smooth PDMS detaching, while 79.9 ± 5.7% of pediveligers remained on the 400 μm texture.  相似文献   

2.
聚合物微流控芯片成本低、易加工,目前在医药、生物检测和化学合成等领域得到了普遍应用。以热塑性聚合物聚甲基丙烯酸甲酯(polymethylmethacrylate,PMMA)和热固型聚合物聚二甲基硅氧烷(polydimethy lsiloxane,PDMS)为基材的高分子聚合物材料因具有较好的生物相容性和光学透明性,已逐渐成为聚合物微流控芯片加工的主导材料,被广泛应用于生物医药类微流控芯片的制备。鉴于该类芯片应用场景的特殊性,需在使用前进行消毒灭菌处理以避免微生物干扰。目前,针对PMMA和PDMS的消毒灭菌方法包括高压蒸汽灭菌、紫外线灭菌、电子束、60Co γ射线辐射灭菌、超临界二氧化碳灭菌、乙醇消毒、环氧乙烷灭菌、过氧化氢低温等离子体灭菌、绿原酸消毒、清洗剂消毒。本文从基本原理、消毒灭菌方法、应用场景等方面,回顾和总结了相关技术在PMMA和PDMS基体微流控芯片中的实现方法,并在芯片材质、适用范围等方面分析了所适用的消毒灭菌方法,为以聚合物为基材的生物医药类微流控芯片的消毒灭菌提供有益参考。  相似文献   

3.
Surface wettability and microtopography can either enhance or deter larval settlement of many sessile marine organisms. This study quantifies the effect of these surface properties on the settlement of pediveligers of Mytilus galloprovincialis, using polymers spanning a range of wettability and microtextured polydimethylsiloxane (PDMS). Furthermore, the adhesion strength of settled pediveligers on microtextured PDMS surfaces was quantified using a flow chamber. Settlement was enhanced at the hydrophilic end of the wettability spectrum, where mean settlement on nylon reached 33.5 ± 13.1%. In contrast, mean settlement on the most hydrophobic polymer (PDMS) was 4.2 ± 3.2%. Microtopography had a much stronger effect compared to wettability, where 400 μm textured PDMS enhanced settlement above 90%. Settlement preferences were also positively correlated to adhesion strength at flow rates of 4 knots, with all initially settled pediveligers on smooth PDMS detaching, while 79.9 ± 5.7% of pediveligers remained on the 400 μm texture.  相似文献   

4.
The control of protein adsorption on microchannel surfaces is important for biosensors. In this study, we demonstrated protein adsorption method that is controlled through temperature change, i.e., thermoresponsive protein adsorption, on polydimethylsiloxane (PDMS) microchannel surfaces using a thermoresponsive polymer, poly(N-isopropylacrylamide) (PNIPAAm). To provide general protein adsorption control method, we adopted biotin-streptavidin chemistry and synthesized streptavidin covalently modified with PNIPAAm (PNIPAAm-StAv). Modification of streptavidin, a hydrophilic protein, with PNIPAAm induced successful thermoresponsive adsorption on a PDMS microchannel surfaces: PNIPAAm-StAv adsorbed at 37 degrees C and desorbed at 10 degrees C on the surfaces. We also demonstrated the thermoresponsive adsorption of biotinylated immunoglobulin G (IgG-b) using PNIPAAm-StAv. Conjugation of IgG-b with PNIPAAm-StAv induced successful thermoresponsive IgG-b adsorption on PDMS. Modification of PDMS surfaces with PNIPAAm reduced physical adsorption of the partially hydrophobic IgG-b on the surface and contributed to the high-contrast thermoresponsive adsorption of IgG-b: less than 1% of the IgG-b adsorbed at 37 degrees C was detected after the PNIPAAm-PDMS surface was washed at 10 degrees C. The controllable adsorption of this system is expected to be applied to the regeneration of biosensor chips and to on-chip protein manipulation.  相似文献   

5.
We show a proof-of-concept in which we combine our previously published concepts of micromosaic immunoassays (microMIAs) with self-regulating microfluidic networks (microFNs) to detect C-reactive protein (CRP) and other cardiac markers such as myoglobin (Mb) and cardiac Troponin I (cTnI). The microFNs are microfabricated in Si, have a well-defined surface chemistry, and are affixed to a bibulous material so as to self-regulate the displacement of an aliquot of liquid through the microFNs using capillary forces. An open section of the channels of the microFNs is covered with a hydrophobic poly(dimethylsiloxane) (PDMS) slab that acts as the substrate for a solid-phase immunoassay. Here, individual assays are conducted using independent channels. These assays are "sequential": series of samples, reagents, and buffers are displaced one after the other over the PDMS surface, and, as these assays are conducted under "microfluidic" conditions, they are fast to perform, very economical in their use of reagents, extremely integrated, and yield high-quality signals. The combinatorial character of microMIAs is exploited to optimize the assay parameters for detecting CRP. In particular, we found it optimal to deposit the capture antibody for CRP on PDMS at a concentration between 20 and 500 microg ml(-1) in PBS in 1 min and to detect captured CRP in 2 min using a detection antibody having a concentration in PBS of 120 microg ml(-1). With this method, CRP is quantitatively detected within 10 min in one microliter of human plasma down to concentrations of 30 ng ml(-1), which suggests the possibility to detect CRP at clinically relevant concentrations for the management of coronary heart disease (CHD) and systemic inflammation.  相似文献   

6.
Body-on-a-chip and organ-on-a-chip systems utilize polydimethylsiloxane (PDMS) because of the relative suitability of the material for fabrication of microfluidic channels and chambers used in these devices. However, hydrophobic molecules, especially therapeutic compounds, tend to adsorb to PDMS, which may distort the dose–response curves that feed into the pharmacokinetic/pharmacodynamic models used to translate preclinical data into predictions of clinical outcomes. Surface modification by organosilanes is one method being explored to modify PDMS, but the effect of organosilanes on drug adsorption isotherms is not well characterized. We utilized Inverse Liquid-Solid Chromatography to characterize the adsorption parameters of the drugs acetaminophen, diclofenac, and verapamil with native PDMS and organosilane-modified (fluoropolymer (13F) and polyethylene glycol) PDMS surfaces, to correlate the modifications with changes in drug adsorption. It was determined that the organosilane modifications significantly changed the energy of adsorption of the test drug utilizing our methodology.  相似文献   

7.
This paper reports the pre-concentration of C-reactive protein (CRP) antigen with packed beads in a microfluidic chamber to enhance the sensitivity of the miniaturized fluorescence detection system for portable point-of-care testing devices. Although integrated optical systems in microfluidic chips have been demonstrated by many groups to replace bulky optical systems, the problem of low sensitivity is a hurdle for on-site clinical applications. Hence we integrated the pre-concentration module with miniaturized detection in microfluidic chips (MDMC) to improve analytical sensitivity. Cheap silicon-based photodiodes with optical filter were packaged in PDMS microfluidic chips and beads were packed by a frit structure for pre-concentration. The beads were coated with CRP antibodies to capture antigens and the concentrated antigens were eluted by an acid buffer. The pre-concentration amplified the fluorescence intensity by about 20-fold and the fluorescence signal was linearly proportional to the concentration of antigens. Then the CRP antigen was analyzed by competitive immunoassay with an MDMC. The experimental result demonstrated that the analytical sensitivity was enhanced up to 1.4 nM owing to the higher signal-to-noise ratio. The amplification of fluorescence by pre-concentration of bead-based immunoassay is expected to be one of the methods for portable fluorescence detection system.  相似文献   

8.
In vitro recording of neuronal electrical activity is a widely used technique to understand brain functions and to study the effect of drugs on the central nervous system. The integration of microfluidic devices with microelectrode arrays (MEAs) enables the recording of networks activity in a controlled microenvironment. In this work, an integrated microfluidic system for neuronal cultures was developed, reversibly coupling a PDMS microfluidic device with a commercial flat MEA through magnetic forces. Neurons from mouse embryos were cultured in a 100 μm channel and their activity was followed up to 18 days in vitro. The maturation of the networks and their morphological and functional characteristics were comparable with those of networks cultured in macro-environments and described in literature. In this work, we successfully demonstrated the ability of long-term culturing of primary neuronal cells in a reversible bonded microfluidic device (based on magnetism) that will be fundamental for neuropharmacological studies.  相似文献   

9.
This paper describes the fabrication, the characterization and the applications of a capillary electrophoresis microchip. This hybrid device (glass/PDMS) features channels and optical waveguides integrated in one common substrate. It can be used for electrophoretic separation and fluorimetric detection of molecules. The microfluidic performance of the device is demonstrated by capillary zone and gel electrophoresis of proteins.  相似文献   

10.
Poly(dimethyl siloxane) (PDMS) is extensively used for biomedical applications due to its low cost, ease of fabrication, high durability and flexibility, oxygen permeability, and self-healing properties. PDMS, however, has some significant drawbacks. PDMS endures unacceptably high levels of nonspecific protein fouling when used with biological samples due to its superhydrophobic characteristics. Unfortunately, conventional surface modification methods do not work for PDMS due to its low glass transition temperature. This phenomenon has been well-known for years as "hydrophobic regeneration". For the same reason, it is also very difficult to bring functionalities onto PDMS surfaces. Herein, we demonstrate how a superhydrophilic zwitterionic material, poly(carboxybetaine methacrylate) (pCBMA), can provide a highly stable coating with long-term stabilty due to the sharp contrast in hydrophobicity between pCBMA and PDMS. This material is able to suppress nonspecific protein adsorption in complex media and functionalize desired biomolecules needed in applications, such as diagnostics, without sacrificing its nonfouling characteristics.  相似文献   

11.
In this study, antibody-based protein microarrays for high-throughput immunoassay were fabricated on an aldehydemodified indium-tin oxide glass plate using the electrospray deposition (ESD) method and their characteristics were evaluated immunochemically. The microarrays were also integrated into microfluidic chips with a polydimethylsiloxane (PDMS) micro-channel to detect human cytokines, which were quantitatively analyzed with a high resolution chargecoupled device. Simultaneous detection of various antigens was performed using the microarrays with considerable sensitivity (ca. 100 pg/mL). The results of this study indicate that microfluidic chip comprising a protein microarray formed by the ESD method and a PDMS micro-channel could be easy to handle, and offers high-throughput detection of molecular biomarkers.  相似文献   

12.
An integrated microfluidic device with injecting, flushing, and sensing functions was realized using valves that operate based on direct electrowetting. The device consisted of two substrates: a glass substrate with driving and sensing electrodes and a poly(dimethylsiloxane) (PDMS) substrate. Microfluidic transport was achieved using the spontaneous movement of solutions in hydrophilic flow channels formed with a dry-film photoresist layer. The injection and flushing of solutions were controlled by gold working electrodes, which functioned as valves. The valves were formed either in the channels or in a through-hole in the glass substrate. To demonstrate the system's applicability to an immunoassay, the detection of immobilized antigens was performed as a partial simulation of a sandwich immunoassay. Human -fetoprotein (AFP) or an anti-human AFP antibody was immobilized on a platinum working electrode in the chamber using a plasma-polymerized film (PPF). By applying a potential to the injection valves, necessary solutions were injected one by one through the channels into a reaction chamber at the center of the chip and incubated for reasonable periods of time. The solutions were then flushed through the flushing valve and absorbed in a filter paper placed under the device. After incubation with the corresponding antibodies labeled with glucose oxidase (GOD), electrochemical detection was conducted. In both cases, the obtained current depended on the amount of immobilized antigen. The calibration curves were sigmoidal, and the detection limit was 0.1 ng. The developed microfluidic system could potentially be a fundamental component for a micro immunoassay of the next generation.  相似文献   

13.
In this work, we develop low-cost microfluidic systems based on polydimethylsiloxane (PDMS) for lab-on-a-chip applications. PDMS microfluidic structures have been fabricated by micromolding, PDMS casting, and plasma bonding processes. The micromolding technique is used to fabricate PDMS slabs with micro-sized grooves, and the complete microchannel is formed by bonding PDMS slab with glass or PDMS substrate. The molding procedure using SU-8 photoresist patterning on silicon wafer, PDMS microchannel fabrication, and PDMS surface treatment using oxygen plasma and TiO2 coating, are discussed. The various parameters for oxygen plasma treatment including RF power and treatment time are studied in order to obtain conditions for good bonding with the glass substrate. The best condition for plasma treatment is found to be the low RF power (8 W) with 5 min treatment time. In addition, TiO2 coating with oxygen plasma treatment has been applied to make PDMS surface more hydrophilic to improve aqueous solution compatilbility. The microfluidic channels for various applications, including sample injection cross channel, micropump channel, T and Y sample mixers, PCR thermocyling chamber and channel, capillary electrophoresis flow channel, and conductimetric systems have been fabricated. Finally, a typical application of the PDMS chip in a flow injection conductimetric system for sodium chloride detection has been demonstrated.  相似文献   

14.
Miniaturized microfluidic systems provide simple and effective solutions for low-cost point-of-care diagnostics and high-throughput biomedical assays. Robust flow control and precise fluidic volumes are two critical requirements for these applications. We have developed microfluidic chips featuring elastomeric polydimethylsiloxane (PDMS) microvalve arrays that: 1) need no extra energy source to close the fluidic path, hence the loaded device is highly portable; and 2) allow for microfabricating deep (up to 1 mm) channels with vertical sidewalls and resulting in very precise features.The PDMS microvalves-based devices consist of three layers: a fluidic layer containing fluidic paths and microchambers of various sizes, a control layer containing the microchannels necessary to actuate the fluidic path with microvalves, and a middle thin PDMS membrane that is bound to the control layer. Fluidic layer and control layers are made by replica molding of PDMS from SU-8 photoresist masters, and the thin PDMS membrane is made by spinning PDMS at specified heights. The control layer is bonded to the thin PDMS membrane after oxygen activation of both, and then assembled with the fluidic layer. The microvalves are closed at rest and can be opened by applying negative pressure (e.g., house vacuum). Microvalve closure and opening are automated via solenoid valves controlled by computer software.Here, we demonstrate two microvalve-based microfluidic chips for two different applications. The first chip allows for storing and mixing precise sub-nanoliter volumes of aqueous solutions at various mixing ratios. The second chip allows for computer-controlled perfusion of microfluidic cell cultures.The devices are easy to fabricate and simple to control. Due to the biocompatibility of PDMS, these microchips could have broad applications in miniaturized diagnostic assays as well as basic cell biology studies.  相似文献   

15.
Microfluidic channel systems were fabricated out of polydimethylsiloxane (PDMS) and used as culture vessels for primary culture of neurons from locust thoracic ganglia. In a biocompatibility study it was shown that cell adhesion and neuronal cell growth of locust neurons on uncoated PDMS was restricted. Coating with concanavalin A improved cell adhesion. In closed-channel microfluidic devices neurons were grown in static-bath culture conditions for more than 15 days. Cell densities of up to 20 cells/channel were not exceeded in low-density cultures but we also found optimal cell growth of single neurons inside individual channels. The first successful cultivation of insect neurons in closed-channel microfluidic devices provides a prerequisite for the development of low density neuronal networks on multi electrode arrays combined with microfluidic devices.  相似文献   

16.
Several studies have shown that the initial surface wettability, is of importance in the settlement of macrofouling larvae such as barnacles, bryozoans and hydroids in the field as well as in laboratory assays. In this study we present results from laboratory assays using hydrophilic and hydrophobic polystyrene (PS) and cyprid larvae of Balanus improvisus (Darwin). The results obtained differ markedly from those reported for the barnacle Balanus amphitrite (Darwin), where a high surface wettability seemed to be preferred for settlement. Our results show that a surface with intermediary wettability (hydrophilic PS) reduced settlement by 38% as compared to surfaces of low wettability (hydrophobic PS) during an 8-day period. During the experiment, the wettability in the hydrophilic PS dishes was not significantly changed as measured by advancing contact angle with mQ water. Over an 8-day period wettability of the hydrophobic PS dishes approached that of the hydrophilic PS surfaces. We further conducted experiments with highly hydrophilic and highly hydrophobic methylsilane-treated glass surfaces with known chemistry. In this experiment, the settlement of cyprid larvae was completely inhibited by the high wettability surfaces. Contact angle measurements revealed that the wettability during the length of the experiment of the hydrophilic glass surfaces was not significantly altered. We conclude by these experiments that even an intermediate wettability can significantly affect the overall settlement success of the barnacle B. improvisus. The mechanism by which the settlement is impeded might be biologically mediated through the recognition by cyprid larvae of the molecular composition of the surface when the cyprid reverts to the settlement phase, i.e. when swimming behaviour is abandoned in favour of surface exploration, or it is mediated by physicochemical forces acting between the surface and the larval body or the larval antennules.  相似文献   

17.
Double emulsions are useful in a number of biological and industrial applications in which it is important to have an aqueous carrier fluid. This paper presents a polydimethylsiloxane (PDMS) microfluidic device capable of generating water/oil/water double emulsions using a coaxial flow focusing geometry that can be fabricated entirely using soft lithography. Similar to emulsion devices using glass capillaries, double emulsions can be formed in channels with uniform wettability and with dimensions much smaller than the channel sizes. Three dimensional flow focusing geometry is achieved by casting a pair of PDMS slabs using two layer soft lithography, then mating the slabs together in a clamshell configuration. Complementary locking features molded into the PDMS slabs enable the accurate registration of features on each of the slab surfaces. Device testing demonstrates formation of double emulsions from 14 µm to 50 µm in diameter while using large channels that are robust against fouling and clogging.  相似文献   

18.
Protein microarrays for allergen-specific antibodies detection were integrated in microfluidic chips, with imaging chemiluminescence as the analytical technique. This paper demonstrates the feasibility of miniaturized chemiluminescent ELISA by presenting rapid, reproducible and sensitive detection of protein antibodies using microfluidics. Three different proteins, beta-lactoglobulin, peanut lectin and human IgG were immobilized via a "macromolecules to polydimethylsiloxane elastomer (PDMS) transfer" protocol and used as capturing agent for the detection of specific antibodies. A convenient and reversible procedure was used to bond the PDMS microarray substrate to complimentary SU-8/glass microfluidic reaction chambers. The hydrodynamic behaviours of the three proteins interactions within the micro-chambers were investigated to select the most efficient flowing parameters (come to terms with the assay time and performances). The use of optimized conditions led to the concomitant detection of three specific antibodies at pM level in 300 microL and using 6 min sample incubation time. Finally, sera from allergic patients were assayed using the microfluidic device modified with apple hazelnut and pollen allergen. The results obtained compared favourably with those obtained with the classical Pharmacia CAP system.  相似文献   

19.
The natural separation maintained by microfluidic flows is employed as the basis of a particle/cell sorting device. This method of separating particulate suspensions exploits the inherent laminar nature of microscale fluid dynamics and incorporates applied fields and image cytometry to enable sorting based upon any visually identifiable difference between colloid-sized cells or particles. This technique may be used to easily isolate, separate, sort, or enrich virtually any suspension of microscale biological or colloidal particles within a microfluidic system. The entire footprint of the device described here is less than 0.01 mm(2), allowing it to be readily incorporated within highly integrated micro total analysis systems (microTAS).  相似文献   

20.
This study reports a microfluidic chip integrated with an arrayed immunoassay for surface plasmon resonance (SPR) phase imaging of specific bio-samples. The SPR phase imaging system uses a surface-sensitive optical technique to detect two-dimensional (2D) spatial phase variation caused by rabbit immunoglobulin G (IgG) adsorbed on an anti-rabbit IgG film. The microfluidic chip was fabricated by using micro-electro-mechanical-systems (MEMS) technology on glass and polydimethylsiloxane (PDMS) substrates to facilitate well-controlled and reproducible sample delivery and detection. Since SPR detection is very sensitive to temperature variation, a micromachine-based temperature control module comprising micro-heaters and temperature sensors was used to maintain a uniform temperature distribution inside the arrayed detection area with a variation of less than 0.3 degrees C. A self-assembled monolayer (SAM) technique was used to pattern the surface chemistry on a gold layer to immobilize anti-rabbit IgG on the modified substrates. The microfluidic chip is capable of transporting a precise amount of IgG solution by using micropumps/valves to the arrayed detection area such that highly sensitive, highly specific bio-sensing can be achieved. The developed microfluidic chips, which employed SPR phase imaging for immunoassay analysis, could successfully detect the interaction of anti-rabbit IgG and IgG. The interactions between immobilized anti-rabbit IgG and IgG with various concentrations have been measured. The detection limit is experimentally found to be 1 x 10(-4)mg/ml (0.67 nM). The specificity of the arrayed immunoassay was also explored. Experimental data show that only the rabbit IgG can be detected and the porcine IgG cannot be adsorbed. The developed microfluidic system is promising for various applications including medical diagnostics, microarray detection and observing protein-protein interactions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号