首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The established radiation quality parameters in mixed neutron-gamma radiation fields may be measured by applying the initial (columnar) recombination of ions in tissue-equivalent (TE) high-pressure ionization chambers (recombination chambers). The mean quality factor can be determined to within 10-15% for mixed fields with neutrons ranging from thermal to 10 MeV, and the dose mean LET of the proton component can be determined to within 10-15% if the gamma-ray absorbed dose fraction is known. These average parameters are derived by measuring the ratio of the ionization currents collected at two high-field strengths and constant gas pressure applied to the ionization chamber. By utilizing approximate correlations between physical parameters in the neutron energy region from thermal to 10 MeV, the dose mean LET of the heavy ion component, the overall dose mean LET, and the microdosimetric parameter y0,D of the mixed field can also be derived. Experimental verification of the method is presented for various neutron-gamma radiation spectra in air and in water by comparison to theoretical calculations and results from low-pressure proportional counter measurements. Good agreement is shown. The TE high-pressure ionization chamber appears to have wide potential for use as a dose-equivalent meter in radiation protection or as a beam characterization device in radiobiology.  相似文献   

2.
Fast neutrons (FN) have a higher radio-biological effectiveness (RBE) compared with photons, however the mechanism of this increase remains a controversial issue. RBE variations are seen among various FN facilities and at the same facility when different tissue depths or thicknesses of hardening filters are used. These variations lead to uncertainties in dose reporting as well as in the comparisons of clinical results. Besides radiobiology and microdosimetry, another powerful method for the characterization of FN beams is the calculation of total proton and heavy ion kerma spectra. FLUKA and MCNP Monte Carlo code were used to simulate these kerma spectra following a set of microdosimetry measurements performed at the National Accelerator Centre. The calculated spectra confirmed major classical statements: RBE increase is linked to both slow energy protons and alpha particles yielded by (n,alpha) reactions on carbon and oxygen nuclei. The slow energy protons are produced by neutrons having an energy between 10 keV and 10 MeV, while the alpha particles are produced by neutrons having an energy between 10 keV and 15 MeV. Looking at the heavy ion kerma from <15 MeV and the proton kerma from neutrons <10 MeV, it is possible to anticipate y* and RBE trends.  相似文献   

3.
A spherical graphite calorimeter was used to determine the ratio of kerma to influence (kerma factor) for neutrons whose mean energy was approximately 14.6 MeV. The calorimeter was used to measure carbon kerma, while activation foils of Al and Au were used to determine the neutron fluence. The calorimeter was constructed specifically to measure kerma in neutron fields. The amount of graphite and other materials was kept to a minimum to reduce absorption and scattering of the neutrons. Ionization chambers were used to measure A-150 plastic kerma and to monitor the intensity of the exposures. The value for the carbon kerma factor was determined to be 1.80 +/- 0.16 X 10(-11) Gy X cm2. The relationship of this value to other recent measurements and calculations at similar neutron energies is discussed.  相似文献   

4.
On the basis of recent recommendations on soft biotissue composition and data concerning value of specific neutron kerma for a number of element atoms within the energy from thermal one to 29 MeV obtained were the values of electron density, effective atomic number and specific kerma of neutrons for soft biotissue and ferrosulphate dosimeter sensitized by benzoic acid. The data are proposed for practical use in radiobiological experiments.  相似文献   

5.
AimThe aim of the investigation was to determine the undesirable dose coming from neutrons produced in reactions (p,n) in irradiated tissues represented by water.BackgroundProduction of neutrons in the system of beam collimators and in irradiated tissues is the undesirable phenomenon related to the application of protons in radiotherapy. It makes that proton beams are contaminated by neutrons and patients receive the undesirable neutron dose.Materials and methodsThe investigation was based on the Monte Carlo simulations (GEANT4 code). The calculations were performed for five energies of protons: 50 MeV, 55 MeV, 60 MeV, 65 MeV and 75 MeV. The neutron doses were calculated on the basis of the neutron fluence and neutron energy spectra derived from simulations and by means of the neutron fluence–dose conversion coefficients taken from the ICRP dosimetry protocol no. 74 for the antero-posterior irradiation geometry.ResultsThe obtained neutron doses are much less than the proton ones. They do not exceed 0.1%, 0.4%, 0.5%, 0.6% and 0.7% of the total dose at a given depth for the primary protons with energy of 50 MeV, 55 MeV, 60 MeV, 65 MeV and 70 MeV, respectively.ConclusionsThe neutron production takes place mainly along the central axis of the beam. The maximum neutron dose appears at about a half of the depth of the maximum proton dose (Bragg peak), i.e. in the volume of a healthy tissue. The doses of neutrons produced in the irradiated medium (water) are about two orders of magnitude less than the proton doses for the considered range of energy of protons.  相似文献   

6.
Dose conversion coefficients for teeth of children were computed for external photon sources by means of Monte Carlo methods using a modified MIRD-type mathematical phantom of a 5-year-old child. The tooth region is separated into eight smaller regions that represent incisors, canines, first and second molars. Each of these sub-regions is separated into enamel and dentin parts. Dose conversion coefficients were computed as ratio of absorbed dose in the enamel and air kerma. They are given for unidirectional (AP, PA, RLAT, LLAT), rotational (ROT) and isotropic (ISO) photon sources in the energy range from 10 keV to 10 MeV. All computations were performed with the MCNP4 code including coupled electron-photon transport. The computed coefficients demonstrate a significant non-linearity versus photon energy, which is more pronounced than that observed for adult phantoms. Due to this non-linearity, use of the EPR-measured doses in human teeth requires information on the incident photon fluence spectra. The data presented can be used for assessment of public exposure.  相似文献   

7.
Measurements in nearly monoenergetic beams of 144, 24.5, and 2 keV neutrons and of thermal neutrons have been performed with low-pressure proportional counters. The suitability of a tissue-equivalent proportional counter (TEPC) for dosimetry of low-energy neutrons has been investigated. In contrast to higher neutron energies, the modification of the primary radiation field by the detector wall and the contribution of secondaries produced in the gas are significant. These effects have been investigated by additional measurements with a carbon-walled proportional counter. The various physical processes of neutron interaction with wall and gas of the TEPC have been analyzed, and absorbed dose, kerma, and kerma contributions from the various processes are presented. In addition, dose contributions from contaminating neutrons and photons have been obtained for the calibration fields used. The results have been related to neutron fluence. The comparison with tabulated kerma factors shows excellent agreement, indicating the suitability of the TEPC method for dosimetry of low-energy neutrons.  相似文献   

8.
PurposeTo determine out-of-field doses produced in proton pencil beam scanning (PBS) therapy using Monte Carlo simulations and to estimate the associated risk of radiation-induced second cancer from a brain tumor treatment.MethodsSimulations of out-of-field absorbed doses were performed with MCNP6 and benchmarked against measurements with tissue-equivalent proportional counters (TEPC) for three irradiation setups: two irradiations of a water phantom using proton energies of 78–147 MeV and 177–223 MeV, and one brain tumor irradiation of a whole-body phantom. Out-of-field absorbed and equivalent doses to organs in a whole-body phantom following a brain tumor treatment were subsequently simulated and used to estimate the risk of radiation-induced cancer. Additionally, the contribution of absorbed dose originating from radiation produced in the nozzle was calculated from simulations.ResultsOut-of-field absorbed doses to the TEPC ranged from 0.4 to 135 µGy/Gy. The average deviation between simulations and measurements of the water phantom irradiations was about 17%. The absorbed dose contribution from radiation produced in the nozzle ranged between 0 and 70% of the total dose; the contribution was however small in absolute terms. The absorbed and equivalent doses to the organs ranged between 0.2 and 60 µGy/Gy and 0.5–151 µSv/Gy. The estimated lifetime risk of radiation-induced second cancer was approximately 0.01%.ConclusionsThe agreement of out-of-field absorbed doses between measurements and simulations was good given the sources of uncertainties. Calculations of out-of-field organ doses following a brain tumor treatment indicated that proton PBS therapy of brain tumors is associated with a low risk of radiation-induced cancer.  相似文献   

9.
Resolving the LET spectrum of environmental radiation in space for assessing dose equivalents creates special problems due to superposition effects. Three components of the radiation field in space, trapped protons, tissue disintegration stars, and neutrons, contribute the bulk of the total dose equivalent. While lack of discrimination of neutron recoil and trapped primary protons does not interfere with correct determination of the combined dose equivalent as such, the simultaneous bursts of several low-energy protons and alpha particles from tissue disintegration stars completely defy LET-resolution with conventional instrumentation. So far, the tissue star dose has been determined only semiquantitatively from nuclear emulsion data. The neutron spectrum in space shows a markedly higher relative fluence in the region beyond 5 MeV than the fission neutron spectrum. Therefore, its LET spectrum centers less heavily on LET values near the proton Bragg Peak. This would call for assigning a QF value of less than 10 to the neutron dose in space. Still more serious shortcomings exist with regard to LET interpretation of heavy primaries.  相似文献   

10.
Doses due to external exposure of terrestrial biota are assessed using differential air kerma from radioactive sources in soil and energy-dependent ‘absorbed dose-per-air kerma’ conversion factors computed for spherical tissue-equivalent bodies. The presented approach allows computing average whole body absorbed dose for terrestrial organisms with body masses from 1 mg to 1,000 kg located at heights from 10 cm to 500 m above ground. Radioactive sources in soil emitting photons with energies from 10 keV to 10 MeV have been considered. Interpolation of the computed quantities over source energy, body mass, and height above ground results in plausible estimates of whole body average absorbed doses for non-human terrestrial biota from gamma-radiation emitted by any radionuclides in contaminated terrain.  相似文献   

11.
Cancer mortality risk coefficients for neutrons have recently been assessed by a procedure that postulates for the neutrons a linear dose dependence, invokes the excess risk of the A-bomb survivors at a gamma-ray dose D(1) of 1 Gy, and assumes a neutron RBE as a function of D(1) between 20 and 50. The excess relative risk (ERR) of 0.008/mGy has been obtained for R(1) = 20 and 0.016/mGy for R(1) = 50. To compare these results to the current ICRP nominal risk coefficient for solid cancer mortality (0.045/Sv for a population of all ages; 0.036/Sv for a working population), the ERR is translated into lifetime attributable risk and is then related to effective dose. The conversion is not trivial, because the neutron effective dose has been defined by ICRP not as a weighted genuine neutron dose (neutron kerma), but as a weighted dose that includes the dose from gamma rays that are induced by neutrons in the body. If this is accounted for, the solid cancer mortality risk for a working population is found to agree with the ICRP nominal risk coefficient for neutrons in their most effective energy range, 0.2 MeV to 0.5 MeV. In radiation protection practice, there is an added level of safety, because the effective dose, E, is-for monitoring purposes-assessed in terms of the operational quantity H*, which overestimates E substantially for neutrons between 0.01 MeV and 2 MeV.  相似文献   

12.
The development of a computational model for the treatment head of a medical electron accelerator (Elekta/Philips SL-18) by the Monte Carlo code mcnp-4C2 is discussed. The model includes the major components of the accelerator head and a pmma phantom representing the patient body. Calculations were performed for a 14 MeV electron beam impinging on the accelerator target and a 10 cm×10 cm beam area at the isocentre. The model was used in order to predict the neutron ambient dose equivalent at the isocentre level and moreover the neutron absorbed dose distribution within the phantom. Calculations were validated against experimental measurements performed by gold foil activation detectors. The results of this study indicated that the equivalent dose at tissues or organs adjacent to the treatment field due to photoneutrons could be up to 10% of the total peripheral dose, for the specific accelerator characteristics examined. Therefore, photoneutrons should be taken into account when accurate dose calculations are required to sensitive tissues that are adjacent to the therapeutic X-ray beam. The method described can be extended to other accelerators and collimation configurations as well, upon specification of treatment head component dimensions, composition and nominal accelerating potential.  相似文献   

13.
AimThe feasibility of using 230 MeV proton cyclotrons in proton therapy centers as a spallation neutron source for Boron Neutron Capture Therapy (BNCT) was investigated.BackgroundBNCT is based on the neutron irradiation of a 10B-containing compound located selectively in tumor cells. Among various types of neutron generators, the spallation neutron source is a unique way to generate high-energy and high-flux neutrons.Materials and MethodsNeutron beam was generated by a proton accelerator via spallation reactions and then the produced neutron beam was shaped to be appropriate for BNCT. The proposed Beam Shaping Assembly (BSA) consists of different moderators, a reflector, a collimator, as well as thermal and gamma filters. In addition, the simulated Snyder head phantom was utilized to evaluate the dose distribution in tumor and normal tissue due to the irradiation by the designed beam. MCNPX2.6 Monte Carlo code was used to optimize BSA as well as evaluate dose evaluation.ResultsA BSA was designed. With the BSA configuration and a beam current of 104 nA, epithermal neutron flux of 3.94 × 106 [n/cm2] can be achieved, which is very low. Provided that we use the beam current of 5.75 μA, epithermal neutron flux of 2.18 × 108 [n/cm2] can be obtained and the maximum dose of 38.2 Gy-eq can be delivered to tumor tissue at 1.4 cm from the phantom surface.ConclusionsResults for 230 MeV protons show that with proposed BSA, proton beam current about 5.75 μA is required for this purpose.  相似文献   

14.
In the first years of its operation, the Mayak Production Association, a facility part of the Soviet nuclear weapons program in the Southern Urals, Russia, discharged large amounts of radioactively contaminated effluent into the nearby Techa River, thus exposing the people living at this river to external and internal radiations. The Techa River Cohort is a cohort intensely studied in epidemiology to investigate the correlation between low-dose radiation and health effects on humans. For the individuals in the cohort, the Techa River Dosimetry System describes the accumulated dose in human organs and tissues. In particular, organ doses from external exposure are derived from estimates of dose rate in air on the Techa River banks which were estimated from measurements and Monte Carlo modelling. Individual doses are calculated in accordance with historical records of individuals’ residence histories, observational data of typical lifestyles for different age groups, and age-dependent conversion factors from air kerma to organ dose. The work here describes an experimentally independent assessment of the key input parameter of the dosimetry system, the integral air kerma, for the former village of Metlino, upper Techa River region. The aim of this work was thus to validate the Techa River Dosimetry System for the location of Metlino in an independent approach. Dose reconstruction based on dose measurements in bricks from a church tower and Monte Carlo calculations was used to model the historic air kerma accumulated in the time from 1949 to 1956 at the shoreline of the Techa River in Metlino. Main issues are caused by a change in the landscape after the evacuation of the village in 1956. Based on measurements and published information and data, two separate models for the historic pre-evacuation geometry and for the current geometry of Metlino were created. Using both models, a value for the air kerma was reconstructed, which agrees with that obtained in the Techa River Dosimetry System within a factor of two.  相似文献   

15.
AimThe aim of this study is simulation of the proton depth-dose distribution and dose evaluation of secondary particles in proton therapy of brain tumor using the GEANT4 and FLUKA Monte Carlo codes.BackgroundProton therapy is a treatment method for variety of tumors such as brain tumor. The most important feature of high energy proton beams is the energy deposition as a Bragg curve and the possibility of creating the spread out Bragg peak (SOBP) for full coverage of the tumor.Materials and methodsA spherical tumor with the radius of 1 cm in the brain is considered. A SNYDER head phantom has been irradiated with 30−130 MeV proton beam energy. A PMMA modulator wheel is used for covering the tumor. The simulations are performed using the GEANT4 and FLUKA codes.ResultsUsing a modulator wheel, the Spread Out Bragg Peak longitudinally and laterally covers the tumor. Flux and absorbed dose of secondary particles produced by nuclear interactions of protons with elements in the head are considerably small compared to protons.ConclusionsUsing 76.85 MeV proton beam and a modulator wheel, the tumor can be treated accurately in the 3-D, so that the distribution of proton dose in the surrounding tissues is very low. The results show that more than 99% of the total dose of secondary particles and protons is absorbed in the tumor.  相似文献   

16.
PurposeScanning proton therapy has dosimetric advantage over passive treatment, but has a large penumbra in low-energy region. This study investigates the penumbra reduction when multi-leaf collimators (MLCs) are used for line scanning proton beams and secondary neutron production from MLCs.MethodsScanning beam plans with and without MLC shaping were devised. Line scanning proton plan of 36 energy layers between 71.2 and 155.2 MeV was generated. The MLCs were shaped according to the cross-sectional target shape for each energy layer. The two-dimensional doses were measured through an ion-chamber array, depending on the presence of MLC field, and Monte Carlo (MC) simulations were performed. The plan, measurement, and MC data, with and without MLC, were compared at each depth. The secondary neutron dose was simulated with MC. Ambient neutron dose equivalents were computed for the line scanning with 10 × 10 × 5 cm3 volume and maximum proton energy of 150 MeV, with and without MLCs, at lateral distances of 25–200 cm from the isocenter. The neutron dose for a wobbling plan with 10 × 10 × 5 cm3 volume was also evaluated.ResultsThe lateral penumbra width using MLC was reduced by 23.2% on average, up to a maximum of 32.2%, over the four depths evaluated. The ambient neutron dose equivalent was 18.52% of that of the wobbling beam but was 353.1% larger than the scanning open field.ConclusionsMLC field shaping with line scanning reduced the lateral penumbra and should be effective in sparing normal tissue. However, it is important to investigate the increase in neutron dose.  相似文献   

17.
The damaging effect of gamma-neutron radiation over a wide neutron-energy range, with average values of 0.37 and 1.2 MeV, and that of electrons with an average electron energy of 25 MeV have been compared in dogs and two monkey species exposed to a broad range of supralethal doses. An analysis of absorbed dose distribution in critical organs and systems has shown the highest effect of gamma-neutron radiation with an average neutron energy of 1.2 MeV. With severity of early clinical manifestations of damage as a criterion, electrons have appeared the most effective. The radiosensitivity of animals grew in the order as follows: dog-->M. fascicularis-->P. hamadryas.  相似文献   

18.
Two very different techniques for measuring the energy of neutrons in the energy range 0.1-10 MeV are presented and compared. A recoil-proton spectrometer is used to determine the energy spectra of neutrons produced by the d(4)-Be and p(4)-Be reactions down to the low-energy threshold of 0.7 MeV. The same radiation fields are also measured with a recently developed method using a high-pressure ionization chamber that can be used to determine the mean energy of the neutrons in a mixed neutron-gamma radiation field provided the gamma-ray absorbed dose fraction is determined independently. An intercomparison of the two methods shows that the high-pressure ionization chamber compares well and supplements the established recoil-proton spectrometer technique. The almost isotropic response of the chamber has enabled measurements to be made of the variation of mean neutron energy with depth in water for the two radiation fields.  相似文献   

19.
PurposeThis study focuses on the configuration and validation of an analytical model predicting leakage neutron doses in proton therapy.MethodsUsing Monte Carlo (MC) calculations, a facility-specific analytical model was built to reproduce out-of-field neutron doses while separately accounting for the contribution of intra-nuclear cascade, evaporation, epithermal and thermal neutrons. This model was first trained to reproduce in-water neutron absorbed doses and in-air neutron ambient dose equivalents, H*(10), calculated using MCNPX. Its capacity in predicting out-of-field doses at any position not involved in the training phase was also checked. The model was next expanded to enable a full 3D mapping of H*(10) inside the treatment room, tested in a clinically relevant configuration and finally consolidated with experimental measurements.ResultsFollowing the literature approach, the work first proved that it is possible to build a facility-specific analytical model that efficiently reproduces in-water neutron doses and in-air H*(10) values with a maximum difference less than 25%. In addition, the analytical model succeeded in predicting out-of-field neutron doses in the lateral and vertical direction. Testing the analytical model in clinical configurations proved the need to separate the contribution of internal and external neutrons. The impact of modulation width on stray neutrons was found to be easily adjustable while beam collimation remains a challenging issue. Finally, the model performance agreed with experimental measurements with satisfactory results considering measurement and simulation uncertainties.ConclusionAnalytical models represent a promising solution that substitutes for time-consuming MC calculations when assessing doses to healthy organs.  相似文献   

20.
Monte Carlo calculations are highly spread and settled practice to calculate brachytherapy sources dosimetric parameters. In this study, recommendations of the AAPM TG-43U1 report have been followed to characterize the Varisource VS2000 192Ir high dose rate source, provided by Varian Oncology Systems.In order to obtain dosimetric parameters for this source, Monte Carlo calculations with PENELOPE code have been carried out. TG-43 formalism parameters have been presented, i.e., air kerma strength, dose rate constant, radial dose function and anisotropy function. Besides, a 2D Cartesian coordinates dose rate in water table has been calculated. These quantities are compared to this source reference data, finding results in good agreement with them.The data in the present study complement published data in the next aspects: (i) TG-43U1 recommendations are followed regarding to phantom ambient conditions and to uncertainty analysis, including statistical (type A) and systematic (type B) contributions; (ii) PENELOPE code is benchmarked for this source; (iii) Monte Carlo calculation methodology differs from that usually published in the way to estimate absorbed dose, leaving out the track-length estimator; (iv) the results of the present work comply with the most recent AAPM and ESTRO physics committee recommendations about Monte Carlo techniques, in regards to dose rate uncertainty values and established differences between our results and reference data.The results stated in this paper provide a complete parameter collection, which can be used for dosimetric calculations as well as a means of comparison with other datasets from this source.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号