首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Dynamin is a 96‐kDa protein that has multiple oligomerization states that influence its GTPase activity. A number of different dynamin effectors, including lipids, actin filaments, and SH3‐domain‐containing proteins, have been implicated in the regulation of dynamin oligomerization, though their roles in influencing dynamin oligomerization have been studied predominantly in vitro using recombinant proteins. Here, we identify higher order dynamin oligomers such as rings and helices in vitro and in live cells using fluorescence lifetime imaging microscopy (FLIM). FLIM detected GTP‐ and actin‐dependent dynamin oligomerization at distinct cellular sites, including the cell membrane and transition zones where cortical actin transitions into stress fibers. Our study identifies a major role for direct dynamin–actin interactions and dynamin's GTPase activity in the regulation of dynamin oligomerization in cells.   相似文献   

2.
Super‐resolution microscopy (SRM) has had a substantial impact on the biological sciences due to its ability to observe tiny objects less than 200 nm in size. Stimulated emission depletion (STED) microscopy represents a major category of these SRM techniques that can achieve diffraction‐unlimited resolution based on a purely optical modulation of fluorescence behaviors. Here, we investigated how the laser beams affect fluorescence lifetime in both confocal and STED imaging modes. The results showed that with increasing illumination time, the fluorescence lifetime in two kinds of fluorescent microspheres had an obvious change in STED imaging mode, compared with that in confocal imaging mode. As a result, the reduction of saturation intensity induced by the increase of fluorescence lifetime can improve the STED imaging resolution at the same depletion power. The phenomenon was also observed in Star635P‐labeled human Nup153 in fixed HeLa cells, which can be treated as a reference for the synthesis of fluorescent labels with the sensitivity to the surrounding environment for resolution improvement in STED nanoscopy.   相似文献   

3.
Multiphoton microscopy (MPM) has become increasingly popular and widely used in both basic and clinical liver studies over the past few years. This technology provides insights into deep live tissues with less photobleaching and phototoxicity, which helps us to better understand the cellular morphology, microenvironment, immune responses and spatiotemporal dynamics of drugs and therapeutic cells in the healthy and diseased liver. This review summarizes the principles, opportunities, applications and limitations of MPM in hepatology. A key emphasis is on the use of fluorescence lifetime imaging (FLIM) to add additional quantification and specificity to the detection of endogenous fluorescent species in the liver as well as exogenous molecules and nanoparticles that are applied to the liver in vivo. We anticipate that in the near future MPM‐FLIM will advance our understanding of the cellular and molecular mechanisms of liver diseases, and will be evaluated from bench to bedside, leading to real‐time histology of human liver diseases.

  相似文献   


4.
Summary FLIM (Fluorescence Lifetime Imaging Microscopy) is a new tool to detect interaction between proteins. The proteins under investigation are fused with fluorescent donor and acceptor molecules. Interaction between the two proteins is accompanied by direct energy transfer from donor to acceptor (FRET), resulting in a shorter lifetime of the fluorescence emitted by the donor molecule. This change in lifetime is detected by FLIM. Fluorescence lifetime imaging can now be done on a widefield fluorescence microscope by using an attachment that is easy to install and simple to operate. The new LIFA attachment is equipped to use different excitation sources. High brightness modulated LEDs as well as lasers modulated by an Accousto Optical Modulator can be used as excitation light source. A modulated image intensifier with digital camera is used as a detector. Power supplies and signal generator are integrated in one control unit that is connected to the light source, detector and computer. All parameters for image acquisition, processing and viewing are easy accessible in the user interface of the software package that uses a modular structure. Lifetime images showing FRET in MCF7 cells with ErbB1-GFP as donor and Py72/Cy3 as acceptor that were taken at EMBL, Heidelberg are shown.  相似文献   

5.
Impaired skin wound healing is a significant comorbid condition of diabetes that is caused by poor microcirculation, among other factors. Studies have shown that angiogenesis, a critical step in the wound healing process in diabetic wounds, can be promoted under hypoxia. In this study, an angiogenesis‐promoting topical treatment for diabetic wounds, which promotes angiogenesis by mimicking a hypoxic environment via inhibition of prolyl hydroxylase resulting in elevation or maintenance of hypoxia‐inducible factor, was investigated utilizing a custom‐built multimodal microscopy system equipped with phase‐variance optical coherence tomography (PV‐OCT) and fluorescence lifetime imaging microscopy (FLIM). PV‐OCT was used to track the regeneration of the microvasculature network, and FLIM was used to assess the in vivo metabolic response of mouse epidermal keratinocytes to the treatment during healing. Results show a significant decrease in the fluorescence lifetime of intracellular reduced nicotinamide adenine dinucleotide, suggesting a hypoxic‐like environment in the wounded skin, followed by a quantitative increase in blood vessel density assessed by PV‐OCT. Insights gained in these studies could lead to new endpoints for evaluation of the efficacy and healing mechanisms of wound‐healing drugs in a setting where delayed healing does not permit available methods for evaluation to take place.   相似文献   

6.
Recent developments in the field of fluorescence lifetime imaging microscopy (FLIM) techniques allow the use of high repetition rate light sources in live cell experiments. For light sources with a repetition rate of 20–100 MHz, the time‐correlated single photon counting (TCSPC) FLIM systems suffer serious dead time related distortions, known as “inter‐pulse pile‐up”. The objective of this paper is to present a new method to quantify the level of signal distortion in TCSPC FLIM experiments, in order to determine the most efficient laser repetition rate for different FLT ranges. Optimization of the F ‐value, which is the relation between the relative standard deviation (RSD) in the measured FLT to the RSD in the measured fluorescence intensity (FI), allows quantification of the level of FI signal distortion, as well as determination of the correct FLT of the measurement. It is shown that by using a very high repetition rate (80 MHz) for samples characterized by high real FLT's (4–5 ns), virtual short FLT components are added to the FLT histogram while a F ‐value that is higher than 1 is obtained. For samples characterized with short real FLT's, virtual long FLT components are added to the FLT histogram with the lower repetition rate (20–50 MHz), while by using a higher repetition rate (80 MHz) the “inter‐pulse pile‐up” is eliminated as the F ‐value is close to 1. (© 2014 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

7.
A frequency‐domain (FD) analysis of fluorescence lifetime (FLT) is a unique and rapid method for cellular and intracellular classifications that can serve for medical diagnostics purposes. Nevertheless, its data analysis process demands nonlinear fitting algorithms that may distort the resolution of the FLT data and hence diminish the classification ability of the method. This research suggests a sample classification technique that is unaffected by the analysis process as it is based on the squared distance (D2) between the raw frequency response data (FRD). In addition, it presents the theory behind this technique and its validation in two simulated data sets of six groups with similar widely and closely spaced FLT data as well as in experimental data of 43 samples from bacterial and viral infected and non‐infected patients. In the two simulated tests, the classification accuracy was above 95% for all six groups. In the experimental data, the classification of 41 out of 43 samples matched earlier report and 29 out of 31 agreed with preliminary physician diagnosis. The D2 approach has the potential to promote FD‐time resolved fluorescence measurements as a medical diagnostic technique with high specifity and high sensitivity for many of today's conventional diagnostic procedures.   相似文献   

8.
Fluorescence lifetime imaging microscopy (FLIM) is an essential tool in many scientific fields such as biology and medicine thanks to the known advantages of the fluorescence lifetime (FLT) over the classical fluorescence intensity (FI). However, the frequency domain (FD) FLIM technique suffers from its strong dependence on the reference and its compliance to the sample. In this paper, we suggest a new way to calculate the FLT by using the crossing point (CRPO) between the modulation and phase FLTs measured over several light emitting diode (LED) DC currents values instead of either method alone. This new technique was validated by measuring homogeneous substances with known FLT, where the CRPO appears to be the optimal measuring point. Furthermore, the CRPO method was applied in heterogeneous samples. It was found that the CRPO in known mixed solutions is the weighted average of the used solutions. While measuring B16 and lymphocyte cells, the CRPO of the DAPI compound in single FLT regions was measured at 3.5 ± 0.06 ns and at 2.83 ± 0.07 ns, respectively, both of which match previous reports and multi‐frequency analyses. This paper suggests the CRPO as a new method to extract the FLT in problematic cases such as high MCP gains and heterogeneous environments.

In traditional FD FLIM measurements, the variation in phase angle and modulation are measured. By measuring over varying DC currents, another variation is detected in the FLT determined through the phase and modulation methods, with the CRPO indicating the true FLT.  相似文献   


9.
Nanocomposites as multifunctional agents are capable of combing imaging and cell biology technologies. The conventional methods used for validation of the conjugation process of nanoparticles (NPs) to fluorescent molecules such as spectroscopy analysis and surface potential measurements, are not sufficient. In this paper we present a new and highly sensitive procedure that uses the combination of (1) fluorescence spectrum, (2) fluorescence lifetime, and (3) steady state fluorescence polarization measurements. We characterize and analyze gold NPs with Lucifer yellow (LY) surface coating as a model. We demonstrate the ability to differentiate between LY‐GNP (the conjugated complex) and a mixture of coated NP and free dyes. We suggest the approach for neuroscience applications where LY is used for detecting and labeling cells, studying morphology and intracellular communications.

Histograms of Fluorescence lifetime imaging (FLIM) of free LY dye (Left) in comparison to the conjugated dye to gold nanoparticles, LY‐GNP (Middle) enable the differentiation between LY‐GNP (the conjugated complex) and a mixture of coated NP and free dyes (Right).  相似文献   


10.
We report on wide‐field time‐correlated single photon counting (TCSPC)‐based fluorescence lifetime imaging microscopy (FLIM) with lightsheet illumination. A pulsed diode laser is used for excitation, and a crossed delay line anode image intensifier, effectively a single‐photon sensitive camera, is used to record the position and arrival time of the photons with picosecond time resolution, combining low illumination intensity of microwatts with wide‐field data collection. We pair this detector with the lightsheet illumination technique, and apply it to 3D FLIM imaging of dye gradients in human cancer cell spheroids, and C. elegans.  相似文献   

11.
Flow cytometry is a powerful means for in vitro cellular analyses where multi‐fluorescence and multi‐angle light scattering can indicate unique biochemical or morphological features of single cells. Yet, to date, flow cytometry systems have lacked the ability to capture complex fluorescence dynamics due to the transient nature of flowing cells. In this contribution we introduce a simple approach for measuring multiple fluorescence lifetimes from a single cytometric event. We leverage square wave modulation, Fourier analysis, and high frequency digitization and show the ability to resolve more than one fluorescence lifetime from fluorescently‐labelled cells and microspheres.

Illustration of a flow cytometer capable of capturing multiple fluorescence lifetime measurements; creating potential for multi‐parametric, time‐resolved signals to be captured for every color channel.  相似文献   


12.
To complement a project toward label‐free optical biopsy and enhanced resection which the overall goal is to develop a multimodal nonlinear endomicroscope, this multimodal approach aims to enhance the accuracy in classifying brain tissue into solid tumor, infiltration and normal tissue intraoperatively. Multiple optical measurements based on one‐ and two‐photon spectral and lifetime autofluorescence, including second harmonic generation imaging, were acquired. As a prerequisite, studying the effect of the time of measurement postexcision on tissue's spectral/lifetime fluorescence properties was warranted, so spectral and lifetime fluorescences of fresh brain tissues were measured using a point‐based linear endoscope. Additionally, a comparative study on tissue's optical properties obtained by multimodal nonlinear optical imaging microscope from fresh and fixed tissue was necessary to test whether clinical validation of the nonlinear endomicroscope is feasible by extracting optical signatures from fixed tissue rather than from freshly excised samples. The former is generally chosen for convenience. Results of this study suggest that an hour is necessary postexcision to have consistent fluorescence intensities\lifetimes. The fresh (a,b,c) vs fixed (d,e,f) tissue study indicates that while all optical signals differ after fixation. The characteristic features extracted from one‐ and two‐photon excitation still discriminate normal brain (a,d) cortical tissue, glioblastoma (GBM) (b,e) and metastases (c,f).   相似文献   

13.
Achieving a maximal safe extent of resection during brain tumor surgery is the goal for improved patient prognosis. Fluorescence‐guided neurosurgery using 5‐aminolevulinic acid (5‐ALA) induced protoporphyrin IX has thereby become a valuable tool enabling a high frequency of complete resections and a prolonged progression‐free survival in glioblastoma patients. We present a widefield fluorescence lifetime imaging device with 250 mm working distance, working under similar conditions such as surgical microscopes based on a time‐of‐flight dual tap CMOS camera. In contrast to intensity‐based fluorescence imaging, our method is invariant to light scattering and absorption while being sensitive to the molecular composition of the tissue. We evaluate the feasibility of lifetime imaging of protoporphyrin IX using our system to analyze brain tumor phantoms and fresh 5‐ALA‐labeled human tissue samples. The results demonstrate the potential of our lifetime sensing device to go beyond the limitation of current intensity‐based fluorescence‐guided neurosurgery.   相似文献   

14.
In vivo imaging of cerebral vasculature is highly vital for clinicians and medical researchers alike. For a number of years non‐invasive optical‐based imaging of brain vascular network by using standard fluorescence probes has been considered as impossible. In the current paper controverting this paradigm, we present a robust non‐invasive optical‐based imaging approach that allows visualize major cerebral vessels at the high temporal and spatial resolution. The developed technique is simple to use, utilizes standard fluorescent dyes, inexpensive micro‐imaging and computation procedures. The ability to clearly visualize middle cerebral artery and other major vessels of brain vascular network, as well as the measurements of dynamics of blood flow are presented. The developed imaging approach has a great potential in neuroimaging and can significantly expand the capabilities of preclinical functional studies of brain and notably contribute for analysis of cerebral blood circulation in disorder models.

An example of 1 × 1.5 cm color‐coded image of brain blood vessels of mouse obtained in vivo by transcranial optical vascular imaging (TOVI) approach through the intact cranium.  相似文献   


15.
Cell death plays a critical role in health and homeostasis as well as in the pathogenesis and treatment of a broad spectrum of diseases and can be broadly divided into two main categories: apoptosis, or programmed cell death, and necrosis, or acute cell death. While these processes have been characterized extensively in vitro, label‐free detection of apoptosis and necrosis at the cellular level in vivo has yet to be shown. In this study, for the first time, fluorescence lifetime imaging microscopy (FLIM) of intracellular reduced nicotinamide adenine dinucleotide (NADH) was utilized to assess the metabolic response of in vivo mouse epidermal keratinocytes following induction of apoptosis and necrosis. Results show significantly elevated levels of both the mean lifetime of NADH and the intracellular ratio of protein bound‐to‐free NADH in the apoptotic compared to the necrotic tissue. In addition, the longitudinal profiles of these two cell death processes show remarkable differences. By identifying and extracting these temporal metabolic signatures, apoptosis in single cells can be studied in native tissue environments within the living organism.

  相似文献   


16.
The rate of complete resection of glioma has improved with the introduction of 5‐aminolevulinic acid‐induced protoporphyrin IX (PpIX) fluorescence image guidance. Surgical outcomes are further enhanced when the fluorescence signal is decoupled from the intrinsic tissue optical absorption and scattering obtained from diffuse reflectance measurements, yielding the absolute PpIX concentration, [PpIX]. Spatial frequency domain imaging was used previously to measure [PpIX] in near‐surface tumors under blue fluorescence excitation. Here, we extend this to subsurface [PpIX] fluorescence under red‐light excitation. The decay rate of the modulation amplitude of the fluorescence signal was used to calculate the PpIX depth, which was then applied in a forward diffusion model to estimate [PpIX] at depth. For brain‐like optical properties in phantoms with PpIX fluorescent inclusions, the depth can be recovered up to depths of 9.5 mm ± 0.4 mm, with [PpIX] ranging from 5 to 15 μg/mL within an average deviation of 15% from the true [PpIX] value.   相似文献   

17.
A novel Widefield frequency‐domain fluorescence lifetime imaging system based on a ultrafast sCMOS sensor is reported. It can do parallel multi‐frequency FLIM up to 620MHz in one measurement with 64 phase images. With this system, measurement of FRET efficiency at multi‐frequencies is demonstrated in living cells. Meanwhile, the temperature change of living cells can be measured at each pixel based on FLIM of Rhodamine B at different frequencies. Further details can be found in the article by Hongtao Chen, Ning Ma, Keiichiro Kagawa, et al. ( e201800223 ).

  相似文献   


18.
Deep tissue imaging in the multiple scattering regime remains at the frontier of fluorescence microscopy. Speckle correlation imaging (SCI) can computationally uncover objects hidden behind a scattering layer, but has only been demonstrated with scattered laser illumination and in geometries where the scatterer is in the far field of the target object. Here, SCI is extended to imaging a planar fluorescent signal at the back surface of a 500‐μm‐thick slice of mouse brain. The object is reconstructed from a single snapshot through phase retrieval using a proximal algorithm that easily incorporates image priors. Simulations and experiments demonstrate improved image recovery with this approach compared to the conventional SCI algorithm.   相似文献   

19.
A STED‐FLIM system is developed to observe the changes of fluorescence lifetime. The pictures show increased lifetime of fluorescent microspheres samples with laser illumination time in both confocal and STED imaging modes. Due to the saturation power of fluorophores is correlated with fluorescence lifetime, the lifetime increase is beneficial for the reduction of the saturation power, indicating the same imaging resolution can be achieved in a lower depletion power. Further details can be found in the article by Lu‐Wei Wang, Yue Chen, Wei Yan, et al. ( e201800315 ).

  相似文献   


20.
We introduce a simple new approach for time‐resolved multiplexed analysis of complex systems using near‐infrared (NIR) dyes, applicable to in vitro and in vivo studies. We show that fast and precise in vitro quantification of NIR fluorophores' short (subnanosecond) lifetime and stoichiometry can be done using phasor analysis, a computationally efficient and user‐friendly representation of complex fluorescence intensity decays obtained with pulsed laser excitation and time‐gated camera imaging. We apply this approach to the study of binding equilibria by Förster resonant energy transfer using two different model systems: primary/secondary antibody binding in vitro and ligand/receptor binding in cell cultures. We then extend it to dynamic imaging of the pharmacokinetics of transferrin engagement with the transferrin receptor in live mice, elucidating the kinetics of differential transferrin accumulation in specific organs, straightforwardly differentiating specific from nonspecific binding. Our method, implemented in a freely‐available software, has the advantage of time‐resolved NIR imaging, including better tissue penetration and background‐free imaging, but simplifies and considerably speeds up data processing and interpretation, while remaining quantitative. These advances make this method attractive and of broad applicability for in vitro and in vivo molecular imaging and could be extended to applications as diverse as image‐guided surgery or optical tomography.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号