首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Fibula free flap: a new method of mandible reconstruction   总被引:65,自引:0,他引:65  
The fibula was investigated as a donor site for free-flap mandible reconstruction. It has the advantages of consistent shape, ample length, distant location to allow a two-team approach, and low donor-site morbidity. It can be raised with a skin island for composite-tissue reconstruction. Twelve segmental mandibular defects (average 13.5 cm) were reconstructed following resection for tumor, most commonly epidermoid carcinoma. Five defects consisted of bone alone, and four others had only a small amount of associated intraoral soft-tissue loss. Eleven patients underwent primary reconstructions. At least two osteotomies were performed on each graft, and miniplates were used for fixation in 11 patients. Six patients received postoperative radiation, and two patients received postoperative chemotherapy. The flaps survived in all patients. All osteotomies healed primarily. The septocutaneous blood supply was generally not adequate to support a skin island for intraoral soft-tissue replacement. The aesthetic result of the reconstruction was excellent in most patients, particularly in "bone only" defects. There was no long-term donor-site morbidity.  相似文献   

2.
The type of fixation (rigid skeletal vs. wire) was assessed against embryologic origin (membranous vs. endochondral) and recipient site (depository vs. resorptive) as variables affecting inlay and onlay bone-graft survival in 20 mature dogs. Wet weight and volume measurements were made at operation and at sacrifice (16 weeks). The results were as follows: (1) Rigid skeletal fixation increased bone-graft volume survival over wire fixation (p less than 0.05). (2) Fixation (i.e., rigid skeletal) and embryologic origin (i.e., membranous) were equal determinants of bone-graft volume survival (p less than 0.001); the recipient site was not significant for onlay bone graft survival. (3) Embryologic origin was the only significant determinant of weight survival (p less than 0.001). (4) Inlay bone grafts demonstrated greater weight and volume survival than onlay bone grafts (p less than 0.05). (5) Histologic and microradiographic studies demonstrated bony union of bone grafts fixed with rigid skeletal fixation, while fibrous union predominated in bone grafts fixed with wire technique.  相似文献   

3.
The musculus masseter, ensuring movements of the mandible, displace the osseous pieces at its fracture up/down in the lateral and medial sides. Morphometrical investigation of the musculi depressores++ mandibulae has been performed. As a whole 33 corpses (29-78 years of age) of normosthenic++ complexion have been studied. The measurements have been performed by means of a special compasses and a ruler with an approximation to 1 mm and 1 degree. The length of the digastric muscle belly is 55.3 +/- 1.1 mm. The length of the geniohyoid muscle is 44.5 +/- 0.9 mm. The distance between the centers, where the digastric muscle are fixed on the hypoglossal bone is 46.1 +/- 1.1 mm, and on the mandible--25 +/- 9 mm. The width of fixation of the musculus mylohyoideus on the mandible is 52.6 +/- 1.2 mm. The angles between the masseter muscles, the mandibular body and the occlusive plane have also been determined.  相似文献   

4.
Rigid fixation of internal orbital fractures   总被引:5,自引:0,他引:5  
When large portions of the internal orbit are destroyed (two to four walls), standard bone-grafting techniques for immediate and late orbital reconstruction may not yield predictable eye position. Critical bone support is most often deficient inferomedially. CT analysis of orbital volume in cases where eye position was unsatisfactory reveals that displacement of bone grafts is one mechanism of the unsatisfactory result. Other mechanisms include undercorrection and bone-graft resorption. In order to minimize postoperative bone-graft displacement, titanium implants were used to span large defects in the internal orbit to provide a platform for bone-graft support. Twenty-six implants were placed in immediate and 12 were placed in late orbital reconstructions. More reliable bone-graft position resulted. Two late infections have occurred resulting in implant removal in a 3-year period.  相似文献   

5.
The use of vascularized bone grafts to reconstruct extremity and mandibular defects is now commonplace in reconstructive surgery. Fibula, scapula, iliac crest, rib, and metatarsal as well as the radial forearm osseocutaneous flaps have all been utilized for this purpose. Troublesome spiral fractures of the distal radius are the most common fractures associated with the use of the distal radius as a vascularized bone-graft donor site. This study was proposed to investigate the effect of donor-site bone loss on the strength of the radius under torsional (rotational) loading. Previous clinical series and experimental studies have not examined this aspect of distal radius loading after harvesting the bone graft. Fifty pairs of sheep tibiae were utilized in the experiment. Five pairs were used in a pilot study and 45 pairs were used in the main experiment. Five pairs of human radii were used for the control in the pilot study. The pilot study attempted to make a comparison between the human radius and the sheep tibia for experimental purposes. For the biomechanical study of donor-site defects, four study groups were examined with random assignment and matched pairs. The control group (group 1) had no alteration to the bone. Each test condition included five matched pairs of sheep tibiae. Experiment 1 compared the difference in the depth of the osteotomy defect. In doing this, one-third of the total length of the bone was removed in each of the following specimens to include (1a) 30 percent of the cross-sectional area of the total bone, (1b) 37 percent of the cross-sectional area of the total bone, and (1c) 50 percent of the cross-sectional area of the total bone. In experiment 2, the osteotomy shape was varied. Instead of the ends of the cuts being squared, the ends were beveled or rounded. Experiment 3 compared different lengths of bone removed in the osteotomy defect and included the following: In experiment 3a the diameter of the sheep tibia was measured at the incisura fibularis. This dimension was one diameter of bone, and a one-diameter length of bone was removed. In experiment 3b, a two-diameter length of bone was removed. In experiment 3c, a three-diameter length of bone was removed. In experiment 3d, a four-diameter length of bone was removed.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

6.
Champy miniplates have been used in the treatment of craniofacial fractures and in osteotomies for correction of posttraumatic deformities, congenital craniofacial deformities, and secondary bony deformities due to pathologies such as hemangioma and neurofibroma. An additional use has been to stabilize free and vascularized bone grafts. The total number of cases reviewed were 50 (25 acute trauma, 4 vascularized mandible reconstruction, and 21 osteotomies of varied types). There were three infections, two in mandibular fractures that were comminuted and compound into the mouth and one in a compound comminuted fracture of the frontal and maxillary area that was judged to be infected when the plate was placed in position. Two plates have been obvious under the skin. No patient has requested plate removal. The advantages of plating in selected cases are decreased operating time, rigid fixation at surgery, good fixation of bone grafts, and the ability to remove intermaxillary fixation in children at the end of the procedure or within the first few postoperative days.  相似文献   

7.
Osseous free flaps have become the preferred method of mandibular reconstruction after oncologic surgical ablation. To elucidate the long-term effects of free flap mandibular reconstruction on bone mass, maintenance or reduction in bone height over time was used as an indirect measure of preservation or loss in bone mass. Factors potentially influencing bone mass preservation were evaluated; these included site of reconstruction (central, body, ramus), patient age, length of follow-up, adjuvant radiotherapy, and the delayed placement of osseointegrated dental implants. A retrospective analysis of patients undergoing osseous free flap mandible reconstruction for oncologic surgical defects between 1987 and 1995 was performed. Postoperative Panorex examinations were used to evaluate bone height and bony union after osteotomy. Fixation hardware was used as a reference to eliminate magnification as a possible source of error in measurement. There were 48 patients who qualified for this study by having at least 24 months of follow-up. There were 27 male and 21 female patients, with a mean age of 45 years (range, 5 to 75 years). Mandibular defects were anterior (24) and lateral (24). Osseous donor sites included the fibula (35), radius (6), scapula (4), and ilium (3). There were between zero and four segmental osteotomies per patient (excluding the ends of the graft). Nineteen percent of all patients had delayed placement of osseointegrated dental implants. Initial Panorex examinations were taken between 1 and 9 months postoperatively (mean, 2 months). Follow-up Panorex examinations were taken 24 to 104 months postoperatively (mean, 47 months). The bony union rate after osteotomy was 97 percent. Bone height measurements were compared by site and type of reconstruction. The mean loss in fibula height by site of reconstruction was 2 percent in central segments, 7 percent in body segments, and 5 percent in ramus segments. The mean loss in bone height after radial free flap mandible reconstruction was 33 percent in central segments and 37 percent in body segments; ramus segments did not lose height. The central and body segments reconstructed with scapular free flaps did not lose height, but one ramus segment lost 20 percent of height. There was no loss in bone height in mandibular body reconstruction with the ilium free flap. Fibula free flaps did not significantly lose bone height when evaluated with respect to age, follow-up, radiation therapy, or dental implant placement. The retention in bone height demonstrated in this study suggests that bone mass is preserved after osseous free flap mandible reconstruction. The greatest amount of bone loss was seen after multiply osteotomized radial free flaps were used for central mandibular reconstruction. The ability of the fibula free flap to maintain mass over time, coupled with its known advantages, further supports its use as the "work horse" donor site for mandible reconstruction.  相似文献   

8.
A recurring issue in studies of quantitative trait loci (QTLs) is whether QTLs that appear to have pleiotropic effects are indeed caused by pleiotropy at single loci or by linked QTLs. Previous work identified a QTL that affected tail length in mice and the lengths of various bones, including the humerus, ulna, femur, tibia, and mandible. The effect of this QTL on tail length has since been found to be due to multiple linked QTLs and so its apparently pleiotropic effects may have been due to linked QTLs with distinct effects. In the present study we examined a line of mice segregating only for a 0.94-Mb chromosomal region known to contain a subset of the QTLs influencing tail length. We measured a number of skeletal dimensions, including the lengths of the skull, mandible, humerus, ulna, femur, tibia, calcaneus, metatarsus, and a tail bone. The QTL region was found to have effects on the size of the mandible and length of the tail bone, with little or no effect on the other traits. Using a randomization approach, we rejected the null hypothesis that the QTL affected all traits equally, thereby demonstrating that the pleiotropic effects reported earlier were due to linked loci with distinct effects. This result underlines the possibility that seemingly pleiotropic effects of QTLs may frequently be due to linked loci and that high-resolution mapping will often be required to distinguish between pleiotropy and linkage.  相似文献   

9.
Finite element analysis is a useful analytical tool for the design of biomedical implants. The aim of this study was to investigate the behavior of temporomandibular joint implants with multiple design variables of the screws used for fixation of the implant. A commercially available implant with full mandible was analyzed using a finite element software package. The effects of different design variables such as orientation, diameter and stem length of the screws on the stress distribution in bone for two different surgical procedures were investigated. Considering the microstrain in bone as a principal factor, the acceptable ranges for screw diameter and length were determined. Parallel orientation of the screws performed better from a stress point of view when compared to the zig-zag orientation. Sufficient contact between the implant collar and mandibular condyle was shown to reduce the peak stresses which may lead to long term success. The distance between screw holes in the parallel orientation was much closer when compared to the zig-zag orientation. However, the stresses in bone near the screw hole area for the parallel orientation were within acceptable limits.  相似文献   

10.

Background

The purpose of this study was to design a customized fixation plate for mandibular angle fracture using topological optimization based on the biomechanical properties of the two conventional fixation systems, and compare the results of stress, strain and displacement distributions calculated by finite element analysis (FEA).

Methods

A three-dimensional (3D) virtual mandible was reconstructed from CT images with a mimic angle fracture and a 1 mm gap between two bone segments, and then a FEA model, including volume mesh with inhomogeneous bone material properties, three loading conditions and constraints (muscles and condyles), was created to design a customized plate using topological optimization method, then the shape of the plate was referenced from the stress concentrated area on an initial part created from thickened bone surface for optimal calculation, and then the plate was formulated as “V” pattern according to dimensions of standard mini-plate finally. To compare the biomechanical behavior of the “V” plate and other conventional mini-plates for angle fracture fixation, two conventional fixation systems were used: type A, one standard mini-plate, and type B, two standard mini-plates, and the stress, strain and displacement distributions within the three fixation systems were compared and discussed.

Results

The stress, strain and displacement distributions to the angle fractured mandible with three different fixation modalities were collected, respectively, and the maximum stress for each model emerged at the mandibular ramus or screw holes. Under the same loading conditions, the maximum stress on the customized fixation system decreased 74.3, 75.6 and 70.6% compared to type A, and 34.9, 34.1, and 39.6% compared to type B. All maximum von Mises stresses of mandible were well below the allowable stress of human bone, as well as maximum principal strain. And the displacement diagram of bony segments indicated the effect of treatment with different fixation systems.

Conclusions

The customized fixation system with topological optimized structure has good biomechanical behavior for mandibular angle fracture because the stress, strain and displacement within the plate could be reduced significantly comparing to conventional “one mini-plate” or “two mini-plates” systems. The design methodology for customized fixation system could be used for other fractures in mandible or other bones to acquire better mechanical behavior of the system and improve stable environment for bone healing. And together with SLM, the customized plate with optimal structure could be designed and fabricated rapidly to satisfy the urgent time requirements for treatment.
  相似文献   

11.
Temporal fossa bone grafts: a new technique in craniofacial surgery   总被引:1,自引:0,他引:1  
The calvarium has become an increasingly popular bone-graft donor site. Previously described harvesting techniques are often difficult to perform and may produce unsatisfactory bone fragments. However, full-thickness bone grafts taken from the region of the temporal fossa, beneath the temporaiis muscle, have proven to be of high quality and technically easy to obtain. In our experience with eight patients, temporal fossa bone grafts were used primarily around the orbit, including reconstruction of the orbital floor, frontal bone, and zygoma. The procedure begins with a hemicoronal or bicoronal incision; the temporalis muscle is reflected, and an underlying bone plate up to 4 X 6 cm is removed. The resulting bone graft is consistently 3 to 4 mm in thickness. The cranial defect is packed with bone debris, and the muscle is replaced. This technique has proven to be safe, technically simple, consistently productive of high-quality bone grafts, and within discernible donor-site deformity.  相似文献   

12.
摘要 目的:分析椎旁肌退变与短节段腰椎融合内固定术后螺钉松动的相关性。方法:回顾性分析2018年6月至2020年6月广州市番禺区中医院行短节段腰椎融合内固定术治疗的251例腰椎退行性疾病患者的临床资料,根据术后螺钉松动情况分为松动组(n=47)和对照组(n=204)。收集患者的临床资料,对比两组椎间植骨融合情况、螺钉直径、螺钉长度、螺钉椎内长度、椎旁肌的肌肉相对总横截面积(rtCSA)和脂肪浸润程度(FI)。应用多因素logistic回归分析短节段腰椎融合内固定术后螺钉松动发生的危险因素,并描绘受试者工作特征(ROC)曲线检验危险因素预测短节段腰椎融合内固定术后螺钉松动的效能。结果:251例患者平均随访时间(24.16±7.28)个月,其中47例患者在最终随访时发生螺钉松动,总体松动率18.73%。两组性别、骨密度比较差异有统计学意义(P<0.05)。与对照组相比,松动组的多裂肌FI增高(P<0.05)。与对照组相比,松动组的竖脊肌rtCSA减少,竖脊肌FI增高(P<0.05)。多因素logistic回归分析显示竖脊肌FI较高是短节段腰椎融合内固定术后螺钉松动发生的独立危险因素,而竖脊肌rtCSA较高、骨密度较高则是保护因素(P<0.05)。ROC曲线分析显示:骨密度、竖脊肌rtCSA、竖脊肌FI等3指标单独及联合应用时:ROC-AUC(0.95CI)分别为0.708(0.446~0.971)、0.736(0.495~0.951)、0.648(0.335~0.965)、0.842(0.719~0.957)。联合应用预测效能较高。结论:竖脊肌的退变是短节段腰椎融合内固定术后螺钉松动的危险因素。当骨密度<-3.00 g/cm2、竖脊肌rtCSA<1.45%及FI>35.00%时,提示术后发生螺钉松动的可能性大,可作为短节段腰椎融合内固定术后评价螺钉松动风险的参考指标。  相似文献   

13.
In summary, distraction osteogenesis is a safe and effective means of achieving bone lengthening. These techniques were originally applied to the long bones of the extremities; over the past 10 years they have been effectively applied to the bones of the craniofacial skeleton. The new bone regenerate that is observed after distraction osteogenesis is stable, and relapse rates after skeletal advancement are believed to be lower than with conventional osteotomy and bone graft techniques. There is considerable variability in distraction protocols employed in clinical practice, including differences in the types of devices used and in the rate, rhythm, latency, and period of consolidation for distraction osteogenesis. The greatest application for distraction osteogenesis in the craniofacial skeleton has been with mandible lengthening, for which there is presently a 10-year clinical experience. Midfacial advancement is a newer application of distraction osteogenesis, for which clinical experience has been accrued over the past 5 years. This latter experience indicates that distraction osteogenesis is a viable treatment option for lengthening of the hypoplastic mandible and midface. These techniques have advantages over conventional means of bone graft and rigid fixation because of the quality of the bone regenerate, the decrease in the long-term relapse rate of the advanced bone segments in both the mandible and the midface, and the simultaneous soft-tissue elongation that accompanies the distraction process. Distraction osteogenesis is particularly applicable to the correction of severe deformities of the mandible and midface in children with developmental hypoplasia and syndromic craniosynostosis. However, growth is an added variable in this patient population. The amount of overcorrection in lengthening of the hypoplastic bone required to compensate for continued growth discrepancy of the adjacent facial bones is difficult to predict. Therefore, the families of these patients should be informed that many children will require repeated operations at a later age as they reach skeletal maturity.  相似文献   

14.
A finite element model of the human dentate mandible has been developed to provide a comparison of fixation systems used currently for fracture reduction. Volume domains for cortical bone, cancellous bone, and teeth were created and meshed in ANSYS 8.0 based on IGES curves created from computerized tomography data. A unilateral molar clench was loaded on the model with a fracture gap simulated along the symphysis. Results based on Von Mises stress in cortical and cancellous bone surrounding the screws, and on fracture surface spatial fixation, show some relative differences between different screw-plate systems, yet all were judged to be appropriate in their reduction potential.  相似文献   

15.
The ability to assess the effects of an implant on bone remodeling is of particular importance to prosthesis placement planning and associated treatment assurance. Prediction of on-going bone responses will enable us to improve the performance of a restoration. Although the bone remodeling for long bones had been extensively studied, there have been relatively few reports for dental scenarios despite its increasing significance with more and more dental implant placements. This paper aimed to develop a systematic protocol to assess mandibular bone remodeling induced by dental implantation, which extends the remodeling algorithms established for the long bones into dental settings. In this study, a 3D model for a segment of a human mandible was generated from in vivo CT scan images, together with a titanium implant embedded to the mandible. The results examined the changes in bone density and stiffness as a result of bone remodeling over a period of 48 months. Resonance frequency analysis was also performed to relate natural frequencies to bone remodeling. The density contours are qualitatively compared with clinical follow-up X-ray images, thereby providing validity for the bone remodeling algorithm presented in dental bone analysis.  相似文献   

16.
Definitive surgical correction of vertical maxillary deficiency   总被引:2,自引:0,他引:2  
H M Rosen 《Plastic and reconstructive surgery》1990,85(2):215-21; discussion 222-3
Inferior repositioning of the maxilla to correct vertical maxillary deficiency has been associated with variable degrees of instability and subsequent relapse. Resorption of bone-graft material has been incriminated as the primary cause of postoperative instability. This paper reports on nine patients who have undergone inferior maxillary repositioning resulting in no residual bone contact between the down-fractured maxilla and superior midface. Mean inferior maxillary repositioning was 6.2 mm. Osteotomy gaps were implanted with porous block hydroxyapatite (Interpore 200), and maxillae were rigidly fixed in position with miniplates. No postoperative intermaxillary fixation was utilized in any patient. Follow-up ranged from 11 to 28 months, with a mean of 19.6 months. Cephalometric analyses at follow-up revealed excellent stability of the repositioned maxillae, with a mean vertical relapse of 4.3 percent. No complications were associated with this procedure. The biomechanical rationale contributing to the success of this operative technique is discussed.  相似文献   

17.
Osseous free flaps have become the preferred method for reconstructing segmental mandibular defects. Of 457 head and neck free flaps, 150 osseous mandible reconstructions were performed over a 10-year period. This experience was retrospectively reviewed to establish an approach to osseous free flap mandible reconstruction. There were 94 male and 56 female patients (mean age, 50 years; range 3 to 79 years); 43 percent had hemimandibular defects, and the rest had central, lateral, or a combination defect. Donor sites included the fibula (90 percent), radius (4 percent), scapula (4 percent), and ilium (2 percent). Rigid fixation (up to five osteotomy sites) was used in 98 percent of patients. Aesthetic and functional results were evaluated a minimum of 6 months postoperatively. The free flap success rate was 100 percent, and bony union was achieved in 97 percent of the osteotomy sites. Osseointegrated dental implants were placed in 20 patients. A return to an unrestricted diet was achieved in 45 percent of patients; 45 percent returned to a soft diet, and 5 percent were on a liquid diet. Five percent of patients required enteral feeding to maintain weight. Speech was assessed as normal (36 percent), near normal (27 percent), intelligible (28 percent), or unintelligible (9 percent). Aesthetic outcome was judged as excellent (32 percent), good (27 percent), fair (27 percent), or poor (14 percent). This study demonstrates a very high success rate, with good-to-excellent functional and aesthetic results using osseous free flaps for primary mandible reconstruction. The fibula donor site should be the first choice for most cases, particularly those with anterior or large bony defects requiring multiple osteotomies. Use of alternative donor sites (i.e., radius and scapula) is best reserved for cases with large soft-tissue and minimal bone requirements. The ilium is recommended only when other options are unavailable. Thoughtful flap selection and design should supplant the need for multiple, simultaneous free flaps and vein grafting in most cases.  相似文献   

18.
Reducing morbidity in the radial forearm flap donor site   总被引:5,自引:0,他引:5  
The radial forearm flap, although widely used, has been criticized for the poor quality of its donor site. To investigate the causes of morbidity, 100 radial artery free-flap donor sites have been reviewed. Sixty-seven patients required skin grafting (group 1), and the remaining 33 patients were closed directly (group 2). Seventeen patients in the series had compound osteocutaneous flaps (group 3). Wound healing proved to be a significant problem in groups 1 and 3, and fracture of the radius occurred in 4 of the 17 patients in group 3 and was the most significant cause of morbidity. The radial artery was reconstructed in 12 patients, but only 6 of the arteries (50 percent) were patent at the time of review. Subjective assessment on a scale of 0 to 10 demonstrated a relatively pain-free donor site with low pain scores (2.5 of 10). The cosmetic result was acceptable in men (1.5 of 10) but was less so in women (4 of 10). Angulated fracture of the radius produced an unacceptable cosmetic result (7 of 10). In light of this experience, we no longer reconstruct the radial artery as a matter of routine. The donor defect is closed directly wherever possible using an ulnar artery-based transposition flap when required. A "boat shaped" osteotomy is used in preference to right-angled bone cuts when harvesting a segment of radius to avoid the complications and sequelae of fracture. These changes in surgical technique have improved the acceptability and minimized the problems associated with this donor site.  相似文献   

19.
目的:对比一期后路半椎体切除短节段植骨融合内固定术与一期前路半椎体切除短节段植骨融合内固定术治疗先天性半椎体畸形的疗效。方法:抽取兰州军区兰州总医院骨科中心脊柱外科46例住院手术治疗先天性半椎体畸形的患者,随机化分为2组,每组23例,分别行一期后路半椎体切除短节段植骨融合内固定术和一期前路半椎体切除短节段植骨融合内固定术,观察比较两纽的手术时间、出血量、术后住院时间、术前和术后6个月侧凸cobb角、后凸cobb角及矫正率。结果:两组间的手术时间、出血量、术后住院时间、术后6个月后凸cobb角及后凸矫正率对比差异有统计学意义。结论:一期后路半椎体切除短节段植骨融合内固定术在后凸畸形矫正方面优于一期前路半椎体切除短节段植骨融合内固定术,且其手术创伤较小、术后恢复较快。  相似文献   

20.
Fibular and scapular osteocutaneous free-tissue transfer represents the workhorse procedure in the reconstruction of large oromandibular defects. However, transplanted bone segments for mandibular reconstruction may be too short for a correct interarch alignment, which is a prerequisite for further functional rehabilitation. Extraoral distraction osteogenesis was performed in the neomandible of five patients after tumor resection following neoadjuvant radiotherapy-chemotherapy. The neomandible was distracted bilaterally in two patients and unilaterally in three patients. Gradual distraction was applied at a rate of 0.5 mm twice a day after osteotomy in the region of vascularized fibular and scapular reconstruction. An average sagittal bone gain of 11 mm was achieved following active distraction. In three patients, the distraction procedure rendered good results with full compensation of the deficit; in one patient, the sagittal bone gain did not compensate for a lateral deviation of the mandible; and in another patient, the fixation pins loosened and had to be reaffixed. Osteodistraction is a treatment option in patients in whom vascularized bone grafts have been used for mandibular reconstruction, but due to contractures or lack of hard and soft tissues, no satisfactory interarch alignment could be achieved. Distraction procedures in irradiated and reconstructed neomandibles bear a higher risk of failure and complications than those in nonirradiated tissues. A correct and stable intermaxillary relation always has to be attempted in the first surgical approach, as osteodistraction cannot be suggested as a routine procedure in this special group of patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号