首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
目的建立SYBR GreenⅠ荧光染料实时定量RT-PCR方法,测定实验动物等来源的EV71病毒RNA。方法运用EV71VP1保守区引物,优化real time RT-PCR条件,运用NASBA方法扩增EV71病毒RNA,计算拷贝数,经10倍系列稀释做出标准曲线,作为EV71病毒RNA定量检测的外标准品。结果应用Qiagen公司QuantiTect SYBR Green RT-PCR Kit,该标准品可精确定量到100copies/μL,PCR扩增效率达到99.5%。结论 SYBRGreenⅠ荧光染料实时定量PCR法测定EV71病毒RNA拷贝数的方法敏感性高、稳定性好,可用于EV71病毒RNA载量的定量测定。  相似文献   

3.
4.
5.
mRNA quantification has become a research hotspot. Quantitative real-time RT-PCR is a popular method but is known to lack precision. To rapidly monitor the kinetics of mRNA levels for the control of microbial fermentation processes, we developed an SYBR Green I-based universal method to directly quantify mRNA from fermentation samples. After total RNA was extracted, the mRNA was hybridized and protected by a longer DNA oligonucleotide. The probe length determined the strength of signal amplification. S1 nuclease and RNase A were used to remove excess probe, single-stranded RNA, and mis-matched RNA/DNA hybrids. Finally, the perfect-matched RNA/DNA hybrid was quantified by SYBR Green I dye. The conditions of liquid hybridization and enzyme digestion were systemically optimized. The kinetic tendency of phzC mRNA levels during phenazine-1-carboxylic acid fermentation was consistent with the results from MB hybridization in our previous report. The detection of mRNA levels of ten genes in Pseudomonas sp. M18G proved that this method is universal and feasible for mRNA quantification, and has great potential for application in mRNA quantification in various organisms.  相似文献   

6.
7.
8.
9.
10.
11.
12.
13.
14.
A431 cells have an amplification of the epidermal growth factor (EGF) receptor gene, the cellular homolog of the v-erb B oncogene, and overproduce an aberrant 2.9-kilobase RNA that encodes a portion of the EGF receptor. A cDNA (pE15) for the aberrant RNA was cloned, sequenced, and used to analyze genomic DNA blots from A431 and normal cells. These data indicate that the aberrant RNA is created by a gene rearrangement within chromosome 7, resulting in a fusion of the 5' portion of the EGF receptor gene to an unidentified region of genomic DNA. The unidentified sequences are amplified to about the same degree (20- to 30-fold) as the EGF receptor sequences. In situ hybridization to chromosomes from normal cells and A431 cells show that both the EGF receptor gene and the unidentified DNA are localized to the p14-p12 region of chromosome 7. By using cDNA fragments to probe DNA blots from mouse-A431 somatic cell hybrids, the rearranged receptor gene was shown to be associated with translocation chromosome M4.  相似文献   

15.
Diagnostic tests based on detection of dengue virus (DENV) genome are available with varying sensitivities and specificities. The Simplexa Dengue assay (Focus Diagnostics) is a newly developed real-time RT-PCR method designed to detect and serotype DENV simultaneously. To assess the performance of the Simplexa Dengue assay, we performed comparison with conventional RT-PCR and SYBR Green real-time RT-PCR on patients sera isolated from eight cities across Indonesia, a dengue endemic country. A total of 184 sera that were confirmed using NS1 and/or IgM and IgG ELISA were examined. Using conventional and SYBR Green real-time RT-PCR, we detected DENV in 53 (28.8%) and 81 (44.0%) out of 184 sera, respectively. When the Simplexa Dengue assay was employed, the detection rate was increased to 76.6% (141 out of 184 samples). When tested in 40 sera that were confirmed by virus isolation as the gold standard, the conventional RT-PCR yielded 95% sensitivity while the sensitivity of SYBR Green real-time RT-PCR and Simplexa Dengue assay reached 97.5% and 100%, respectively. The specificities of all methods were 100% when tested in 43 non-dengue illness and 20 healthy human samples. Altogether, our data showed the higher detection rate of Simplexa Dengue compared to conventional and SYBR Green real-time RT-PCR in field/surveillance setting. In conclusion, Simplexa Dengue offers rapid and accurate detection and typing of dengue infection and is suitable for both routine diagnostic and surveillance.  相似文献   

16.
17.
18.
A one-step SYBR Green I real-time RT-PCR assay was developed for the detection and quantification of a broad range of murine noroviruses (MNVs). The primer design was based on the multiple sequence alignments of 101 sequences of the open reading frame (ORF)1−ORF2 junction of MNV. The broad reactivity and quantitative capacity of the assay were validated using 7 MNV plasmids. The assay was completed within 1 h, and the reliable detection limit was 10 copies of MNV plasmid or 0.063 median tissue culture infective doses per milliliter of RAW264 cell culture-propagated viruses. The diagnostic performance of the assay was evaluated using 158 mouse fecal samples, 91 of which were confirmed to be positive. The melting curve analysis demonstrated the diversity of MNV in the samples. This is the first report of a broadly reactive one-step SYBR Green I real-time RT-PCR assay for detecting of MNVs. The rapid and sensitive performance of this assay makes it a powerful tool for diagnostic applications.  相似文献   

19.
Polymerase chain reaction (PCR) is a sensitive and rapid method for the diagnosis of canine Leishmania infection and can be performed on a variety of biological samples, including peripheral blood, lymph node, bone marrow and skin. Standard PCR requires electrophoretic analysis of the amplification products and is usually not suitable for quantification of the template DNA (unless competitor-based or other methods are developed), being of reduced usefulness when accurate monitoring of target DNA is required. Quantitative real-time PCR allows the continuous monitoring of the accumulation of PCR products during the amplification reaction. This allows the identification of the cycle of near-logarithmic PCR product generation (threshold cycle) and, by inference, the relative quantification of the template DNA present at the start of the reaction. Since the amplification product are monitored in "real-time" as they form cycle-by-cycle, no post-amplification handling is required. The absolute quantification is performed according either to an internal standard co-amplified with the sample DNA, or to an external standard curve obtained by parallel amplification of serial known concentrations of a reference DNA sequence. From the quantification of the template DNA, an estimation of the relative load of parasites in the different samples can be obtained. The advantages compared to standard and semi-quantitative PCR techniques are reduction of the assay's time and contamination risks, and improved sensitivity. As for standard PCR, the minimal components of the quantitative PCR reaction mixture are the DNA target of the amplification, an oligonucleotide primer pair flanking the target sequence, a suitable DNA polymerase, deoxynucleotides, buffer and salts. Different technologies have been set up for the monitoring of amplification products, generally based on the use of fluorescent probes. For instance, SYBR Green technology is a non-specific detection system based on a fluorescent dsDNA intercalator and it is applicable to all potential targets. TaqMan technology is more specific since performs the direct assessment of the amount of amplified DNA using a fluorescent probe specific for the target sequence flanked by the primer pair. This probe is an oligonucleotide labelled with a reporter dye (fluorescent) and a quencher (which absorbs the fluorescent signal generated by the reporter). The thermic protocol of amplification allows the binding of the fluorescent probe to the target sequence before the binding of the primers and the starting of the polymerization by Taq polymerase. During polymerization, 5'-3' exonuclease activity of Taq polymerase digests the probe and in this way the reporter dye is released from the probe and a fluorescent signal is detected. The intensity of the signal accumulates at the end of each cycle and is related to the amount of the amplification product. In recent years, quantitative PCR methods based either on SYBR Green or TaqMan technology have been set up for the quantification of Leishmania in mouse liver, mouse skin and human peripheral blood, targeting either single-copy chromosomal or multi-copy minicircle sequences with high sensitivity and reproducibility. In particular, real-time PCR seems to be a reliable, rapid and noninvasive method for the diagnosis and follow up of visceral leishmaniasis in humans. At present, the application of real-time PCR for research and clinical diagnosis of Leishmania infection in dogs is still foreseable. As for standard PCR, the high sensitivity of real-time PCR could allow the use of blood sampling that is less invasive and easily performed for monitoring the status of the dogs. The development of a real-time PCR assay for Leishmania infantum infection in dogs could support the standard and optimized serological and PCR methods currenly in use for the diagnosis and follow-up of canine leishmaniasis, and perhaps prediction of recurrences associated with tissue loads of residual pathogens after treatment. At this regard, a TaqMan Real Time PCR method developed for the quantification of Leishmania infantum minicircle DNA in peripheral blood of naturally infected dogs sampled before and at different time points after the beginning of a standard antileishmanial therapy will be illustrated.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号