首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 24 毫秒
1.
Isolation of the pulmonary veins may be an effective treatment modality for eliminating atrial fibrillation (AF) episodes but unfortunately not for all patients. When ablative therapy fails, it is assumed that AF has progressed from a trigger-driven to a substrate-mediated arrhythmia. The effect of radiofrequency ablation on persistent AF can be attributed to various mechanisms, including elimination of the trigger, modification of the arrhythmogenic substrate, interruption of crucial pathways of conduction, atrial debulking, or atrial denervation. This review discusses the possible effects of pulmonary vein isolation on the fibrillatory process and the necessity of cardiac mapping in order to comprehend the mechanisms of AF in the individual patient and to select the optimal treatment modality.  相似文献   

2.
The development of pulmonary vein stenosis has recently been described after radiofrequency ablation (RF) to treat atrial fibrillation (AF). The purpose of this study was to examine expression of TGFβ1 in pulmonary vein stenosis after radiofrequency ablation in chronic atrial fibrillation of dogs. About 28 mongrel dogs were randomly assigned to the sham-operated group (n = 7), the AF group (n = 7), AF + RF group (n = 7), and RF group (n = 7). In AF or AF + RF groups, dogs underwent chronic pulmonary vein (PV) pacing to induce sustained AF. RF application was applied around the PVs until electrical activity was eliminated. Histological assessment of pulmonary veins was performed using hematoxylin and eosin staining; TGFβ1 gene expression in pulmonary veins was examined by RT-PCR analysis; expression of TGFβ1 protein in pulmonary veins was assessed by Western blot analysis. Rapid pacing from the left superior pulmonary vein (LSPV) induced sustained AF in AF group and AF + RF group. Pulmonary vein ablation terminated the chronic atrial fibrillation in dogs. Histological examination revealed necrotic tissues in various stages of collagen replacement, intimal thickening, and cartilaginous metaplasia with chondroblasts and chondroclasts. Compared with sham-operated and AF group, TGFβ1 gene and protein expressions was increased in AF + RF or RF groups. It was concluded that TGFβ1 might be associated with pulmonary vein stenosis after radiofrequency ablation in chronic atrial fibrillation of dogs. Shufeng Li and Hongli Li contributed equally to the work.  相似文献   

3.
Isolation of the pulmonary veins has been used as surgical treatment for atrial fibrillation (AF) from the early 90s, as it was incorporated in the Maze procedure. With the evidence that triggers form this area can induce AF, the Maze III procedure has been adapted and modified towards a single lesion around the pulmonary veins for the treatment of paroxysmal and chronic AF in some centers. New ablation techniques with a diversity of energy sources further paved the way for less invasive procedures. Minimal invasive techniques to prevent major surgery may potentially make the treatment available for a patient population that do not have to undergo cardiac surgery for other reasons. Besides these technical developments, high density mapping can be used to identify the AF substrate in the individual patient and optimization of the treatment by local substrate guided ablation. This review aims to summarize the robotic and thoracoscopic techniques to isolate the pulmonary veins. Furthermore, it is discussed why pulmonary veins isolation may be effective in patients with chronic AF, and whether there is a role for mapping guided minimal invasive surgical treatment of AF in the near future.  相似文献   

4.

Background

The relationship between focal pulmonary vein potential and atrial fibrillation (AF) has been confirmed. Pulmonary vein (PV) isolation and circumferential pulmonary vein ablation have been the most commonly used procedures of radiofrequency ablation. However, few studies have investigated the relationship between anatomical characteristics of PV and AF recurrences after radiofrequency ablation.

Methodology

For 267 AF patients treated by radiofrequency catheter ablation, the anatomic structure characteristics of pulmonary veins were assessed by multi-slice spiral computed tomography while the values of left atrial diameter (LAD) were measured with transesophageal ultrasonic cardiogram. After radiofrequency catheter ablation, postoperative recurrence was evaluated during a 10-month term follow-up.

Principal Findings

During follow-up, postoperative recurrence occurred in 44 patients. The mean diameters of LAD, left superior PV, right superior PV, all left PV, and all superior PV were significantly larger in patients with postoperative recurrence (Recurrence vs. Non-recurrence group; 43.9 ± 6.4 mm vs. 40.7 ± 5.6 mm; 18.4 ± 2.1 mm vs. 17.1 ± 3.1 mm; 18.2 ± 2.8 mm vs. 17.2 mm ± 3.9 mm; 16.4 ± 1.5 mm vs. 15.6 ± 2.5 mm; 18.3 ± 2.1 mm vs. 17.1 ± 3.0 mm; respectively; all P < 0.05). Multivariable survival analysis showed that the type and the course of AF, LAD, and the diameters of all superior PV were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.

Conclusions

The enlargements of all superior PV and LAD, long course of diseases, and persistent AF were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.  相似文献   

5.
Identification of the critical isthmus of the reentrant tachycardia is essential to maximize the effect of catheter ablation (CA) and to minimize the myocardial injury of CA. An 81-year-old woman presented recurrent palpitations after CA of atrial fibrillation (AF) and atrial tachycardia (AT). She had moderate aortic valve stenosis and coronary artery disease. She had received a pulmonary vein isolation, left atrial (LA) posterior wall isolation, and LA anterior linear ablation for atrial fibrillation 1 year prior. At the start of the procedure, she was in sinus rhythm. Atrial burst pacing induced an AT (230msec). High-density mapping revealed a figure-of-eight activation pattern within the LA appendage (LAA), accounting for 99% of the tachycardia cycle length. The critical isthmus was identified at the mid LAA and the local electrogram of the critical isthmus was not fractionated. A single radiofrequency application at the critical isthmus of the AT, terminated the AT. She was free from any ATs for 28 months.Radiofrequency ablation of the localized reentrant AT was usually performed targeting long fractionated electrograms. In our case, the local electrogram at the critical isthmus was not fragmented compared with the LAA distal part. Long fractionated electrograms were recorded at a more distal part of the LAA than the common isthmus and we could avoid the potential risk of a perforation. A recent developed 3-dimensional electro-anatomical mapping system can identify the critical isthmus and allow us to select a new therapeutic strategy for a critical isthmus ablation of an AT within the LAA.  相似文献   

6.
目的:探讨房颤射频消融术后肺静脉狭窄的相关因素,为其预防提供依据。方法:收集113例射频消融房颤患者的临床资料,记录射频术中消融时间、阻抗和温度;术后6个月64层CT左房-肺静脉重建随访,统计肺静脉狭窄的发生率;多元Logistic回归分析肺静脉狭窄的相关因素。结果:依据肺静脉数量计算的肺静脉狭窄率为3.4%,按照患者数量计算的肺静脉狭窄率为7.7%。多元Logistic回归分析,初始50例手术较其后病例的OR为2.167,95%CI=I.038-9.857,P=0.046,消融时间在总消融时间均数之上的患者比在均数之下者OR为2.856,95%CI=1.352-6.043,P=0.021。结论:初始50例手术和消融时间长是房颤射频消融术后肺静脉狭窄的相关因素。  相似文献   

7.
The thoracic vein hypothesis of chronic atrial fibrillation (AF) posits that rapid, repetitive activations from muscle sleeves within thoracic veins underlie the mechanism of sustained AF. If this is so, thoracic vein ablation should terminate sustained AF and prevent its reinduction. Six female mongrel dogs underwent chronic pulmonary vein (PV) pacing at 20 Hz to induce sustained (>48 h) AF. Bipolar electrodes were used to record from the atria and thoracic veins, including the vein of Marshall, four PVs, and the superior vena cava. Radio frequency (RF) application was applied around the PVs and superior vena cava and along the vein of Marshall until electrical activity was eliminated. Computerized mapping (1,792 electrodes, 1 mm resolution) was also performed. Sustained AF was induced in 30.6 +/- 6.5 days, and ablation was done 17.3 +/- 8.5 days afterward. Before ablation, the PVs had shorter activation cycle lengths than the atria, and rapid, repetitive activations were observed in the PVs. All dogs converted to sinus rhythm during (n = 4 dogs) or within 90 min of completion of RF ablation. Rapid atrial pacing afterward induced only nonsustained (<60 s) AF in all dogs. Average AF cycle lengths after reinduction were significantly (P = 0.01) longer (183 +/- 31.5 ms) than baseline (106 +/- 16.2 ms). There were no activation cycle length gradients after RF application. We conclude that thoracic vein ablation converts canine sustained AF into sinus rhythm and prevents the reinduction of sustained AF. These findings suggest that thoracic veins are important in the maintenance of AF in dogs.  相似文献   

8.
Catheter ablation provides an important treatment option for patients with both paroxysmal and persistent atrial fibrillation. It mainly involves pulmonary vein isolation and additional ablations in the left atrium in persistent cases. There have been significant advancements in this procedure to enhance the safety and effectiveness. One of them is the evolution of various imaging modalities to facilitate better visualization of the complex left atrial anatomy and the pulmonary veins in order to deliver the lesions accurately. In this article, we review the electroanatomic mapping systems including the magnetic-based and impedence-based systems. Each of these mapping systems has its own advantages and disadvantages. In addition, we also discuss the role of intracardiac echocardiography and three dimensional rotational angiography in atrial fibrillation ablation.  相似文献   

9.
A 69-year-old woman with palpitations was referred to our hospital for a second session of atrial fibrillation (AF) catheter ablation. She had a history of AF ablation including pulmonary vein (PV) isolation and persistent left superior vena cava (PLSVC) isolation. Electrophysiologic studies showed the veno-atrial connections that had recovered. After PV isolation was performed, AF was induced by atrial premature contraction (APC) from the PLSVC, and AF storm occurred. During PLSVC isolation, AF was not induced by APC from the PLSVC. PLSVC isolation continued during sinus rhythm. The elimination of the PLSVC potential was difficult to confirm because of the far-field potential of the left ventricle. Then, we performed right ventricular pacing. The remaining PLSVC potential was identified. After that, the PLSVC isolation was successful during right ventricular pacing. Complications were not observed. The patient had no recurrence of AF thereafter.  相似文献   

10.
Phrenic Nerve Injury (PNI) has been well studied by cardiac surgeons. More recently it has been recognized as a potential complication of catheter ablation with a prevalence of 0.11 to 0.48 % after atrial fibrillation (AF) ablation. This review will focus on PNI after AF ablation. Anatomical studies have shown a close relationship between the right phrenic nerve and it's proximity to the superior vena cava (SVC), and the antero-inferior part of the right superior pulmonary vein (RSPV). In addition, the proximity of the left phrenic nerve to the left atrial appendage has been well established. Independent of the type of ablation catheter (4 mm, 8 mm, irrigated tip, balloon) or energy source used (radiofrequency (RF), ultrasound, cryothermia, and laser); the risk of PNI exists during ablation at the critical areas listed above. Although up to thirty-one percent of patients with PNI after AF ablation remain asymptomatic, dyspnea remain the cardinal symptom and is present in all symptomatic patients. Despite the theoretical risk for significant adverse effect on functional status and quality of life, short-term outcomes from published studies appear favorable with 81% of patients with PNI having a complete recovery after 7 +/- 7 months. CONCLUSION: Existing studies have described PNI as an uncommon but avoidable complication in patients undergoing pulmonary vein isolation for AF. Prior to ablation at the SVC, antero-inferior RSPV ostium or the left atrial appendage, pacing should be performed before energy delivery. If phrenic nerve capture is documented, energy delivery should be avoided at this site. Electrophysiologist's vigilance as well as pacing prior to ablation at high risk sites in close proximity to the phrenic nerve are the currently available tools to avoid the complication of PNI.  相似文献   

11.
We report on a 22-month-old boy with drug-resistant atrioventricular reentrant tachycardia and complex structural heart disease consisting of right atrial isomerism, mirror image orientation of the intrathoracic veins, hemi-azygos continuation to the left superior vena cava, separate drainage of the hepatic veins into the left-sided atrium, congenitally corrected transposition, pulmonary atresia, and atrial and ventricular septal defects.Access to the heart for radiofrequency (RF) ablation was obtained by percutaneous puncture of a hepatic vein, the left internal jugular vein, and femoral artery. The accessory pathway was localised to the free wall of the left-sided AV groove and successfully ablated. There were no procedure-related complications.RF ablation of an accessory pathway is feasible in young children with complex structural heart disease and abnormal systemic venous return. In such patients access to the heart must be planned with knowledge of the anatomy and judicious use of the hepatic venous approach.  相似文献   

12.
In patients with atrial fibrillation (AF) having congenital anatomical abnormalities, such as complete situs inversus and dextrocardia, pulmonary vein isolation (PVI) ablation can be performed safety using a three-dimensional electroanatomical mapping system. However, it is not clear whether a three-dimensional electroanatomical mapping system can be used to detect non-PV ectopic beats initiating AF in patients with complete situs inversus and dextrocardia. Here, we report a 21-year-old man with complete situs inversus and dextrocardia, who showed AF caused by non-PV ectopic beats. We successfully detected the origin of the triggered activity from the non-PV foci using three-dimensional electroanatomical mapping.  相似文献   

13.
Persistent left superior vena cava is a rarely seen anomaly but it may be an arrhythmogenic source for paroxysmal atrial fibrillation. Furthermore, the complex anatomicregion between the left superior vena cava and the pulmonary veins may leads to misinterpretation of the pulmonary vein recordings during atrial fibrillation ablation. Approaches that might be helpful to overcome these problems are discussed in this case report.  相似文献   

14.

Atrial fibrillation (AF) is part of a vicious cycle that includes multiple cardiovascular risk factors and comorbidity which can promote atrial remodelling and AF progression. Most AF-related risk factors—hypertension, diabetes, sleep apnoea, obesity and sedentary lifestyle—are in essence modifiable which may prevent AF development. Treatment of associated cardiovascular conditions may prevent both symptoms and future cardiovascular events. For advanced forms of symptomatic AF refractory to lifestyle management and optimal medication, invasive ablation therapies have become a cornerstone. Although electrical trigger isolation from the pulmonary veins is reasonably effective and safe, more potent energy sources including high output-short duration radiofrequency, ultra-low cryo-energy, and electroporation, as well as more sophisticated arrays, balloons, and lattice-tipped catheter tools, are on their way to eliminate existing pitfalls and simplify the procedure. Electroanatomical navigation and mapping systems are becoming available to provide real-time information on ablation lesion quality and the critical pathways of AF in the individual patient to guide more extensive ablation strategies that may enhance long-term outcome for freedom of advanced AF. Surgical techniques, either stand-alone or concomitant to structural cardiac repair, hybrid, or convergent, with novel less invasive access options are developing and can be helpful in situations unsuitable for catheter ablation.

  相似文献   

15.

Background  

Catheter ablation of the pulmonary veins has become accepted as a standard therapeutic approach for symptomatic paroxysmal atrial fibrillation (AF). However, there is some evidence for an ablation associated (silent) stroke risk, lowering the hope to limit the stroke risk by restoration of rhythm over rate control in AF. The purpose of the prospective randomized single-center study "Mesh Ablator versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation" (MACPAF) is to compare the efficacy and safety of two balloon based pulmonary vein ablation systems in patients with symptomatic paroxysmal AF.  相似文献   

16.
BackgroundThe Arctic Front Cryoballoon System is a technology in which substrate alterations in patients with atrial fibrillation (AF) recurrence have not been well characterized. In this study, we evaluated sites of pulmonary vein (PV) reconnections and the accuracy of the Achieve? circular mapping catheter in detecting these reconnections after cryoablation.MethodsThis study included 15 patients undergoing redo AF ablation after a prior single cryoablation procedure. PV reconnection sites were determined by measuring PV signals and high output pacing from 4 vectors of the Achieve catheter. The results were compared with a roving mapping catheter guided by rotational intracardiac echocardiography (ICE) in the left atrium.ResultsAll patients had PV reconnections (2.1 ± 0.8 veins/patient). The left superior PV was most commonly reconnected (n = 11), whereas the right inferior PV was least likely (n = 3). Both carinas (left: n = 11; right: n = 7) and left atrial appendage ridge (n = 11) were also frequently reconnected. Mapping with the Achieve catheter showed a positive predictive value (PPV) 100% and negative predictive value (NPV) 96% when compared with ICE guided mapping. In 2 patients, right superior PV reconnection was not identified by the Achieve.ConclusionDuring redo AF ablation after index cryoablation, multiple PVs are usually reconnected, with both carinas and left atrial appendage ridge being common sites of reconnection. The Achieve mapping catheter was able to identify reconnection with high positive and negative predictive values.  相似文献   

17.

Introduction

Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block.

Methods and results

Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings.Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs.

Conclusions

Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.  相似文献   

18.
A 67-year-old man underwent a third ablation procedure for a recurrent atrial tachycardia (AT) after an extensive pulmonary vein (PV) isolation, linear ablation along the left atrial (LA) roof and posterolateral mitral isthmus (MI), and defragmentation of persistent atrial fibrillation and an induced perimitral AT. High-resolution mapping during the clinical AT using the Rhythmia system (Boston Scientific) suggested that the AT was a ridge-related reentrant AT and exhibited a reconnection of the left PVs (LPVs). The residual electrograms in the posterior LPVs were surrounded by endocardial scar, which was like an island consisting of residual LPV electrograms. Retrograde venography of the vein of Marshall (VOM) demonstrated that the VOM reached the posterior left superior PV through the ridge between the LA appendage and left inferior PV and then the LPV carina. An ethanol infusion into the VOM resulted in a simultaneous AT termination and complete electrical isolation of the LPVs, that is, the disappearance of the residual LPV electrograms. The insular residual LPV electrograms in the present case did not appear to be endocardially connected to the LA, because the LPV electrograms were surrounded by endocardial scar and there was a large time gap between the earliest activation in the posterior LPVs and activation in the surrounding area. The VOM course on the venography and elimination of the residual LPV electrograms with an ethanol infusion into the VOM suggested that the insular residual LPV electrograms were electrically connected to the posterolateral LA via the VOM and its branches.  相似文献   

19.
Pulmonary vein (PV) isolation (PVI) techniques have evolved as a curative treatment of atrial fibrillation (AF) since PVI guided by circumferential mapping with a circular catheter was initially proposed. A multielectrode basket catheter (MBC) is also useful for PVI because of some advantages; (1) an MBC provides some information about the PV anatomy on the fluoroscopic image, (2) an MBC can utilize the non-fluoroscopic navigation system, (3) an MBC enables the direct three-dimensional mapping around the PV ostium and antrum, (4) the distal electrodes of the MBC can be used to monitor some activation changes within the PV in real time and thereby indicate the effects of ablation at the ostium and antrum as radiofrequency lesions are created. PVI with an MBC is an effective and safe procedure to cure AF by integrating the PV anatomy and electrophysiology in combination with a non-fluoroscopic three-dimensional navigation system for the ablation catheter.  相似文献   

20.
Background: Pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). During PVI an electrical conduction block between pulmonary vein (PV) and left atrium (LA) is created. This conduction block prevents AF, which is triggered by irregular electric activity originating from the PV. However, transmural atrial lesions are required which can be challenging. Re-conduction and AF recurrence occur in 20 - 40% of the cases. Robotic catheter systems aim to improve catheter steerability. Here, a procedure with a new remote catheter system (RCS), is presented. Objective of this article is to show feasibility of robotic AF ablation with a novel system. Materials and Methods: After interatrial trans-septal puncture is performed using a long sheath and needle under fluoroscopic guidance. The needle is removed and a guide wire is placed in the left superior PV. Then an ablation catheter is positioned in the LA, using the sheath and wire as guide to the LA. LA angiography is performed over the sheath. A circular mapping catheter is positioned via the long sheath into the LA and a three-dimensional (3-D) anatomical reconstruction of the LA is performed. The handle of the ablation catheter is positioned in the robotic arm of the Amigo system and the ablation procedure begins. During the ablation procedure, the operator manipulates the ablation catheter via the robotic arm with the use of a remote control. The ablation is performed by creating point-by-point lesions around the left and right PV ostia. Contact force is measured at the catheter tip to provide feedback of catheter-tissue contact. Conduction block is confirmed by recording the PV potentials on the circular mapping catheter and by pacing maneuvers. The operator stays out of the radiationfield during ablation. Conclusion: The novel catheter system allows ablation with high stability on low operator fluoroscopy exposure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号